Manual · Sick
Technical Information: ZoneControl Zero Pressure Accumulation
Manual36 pagesPDF 2.1 MB
SICK technical information on ZoneControl zero pressure accumulation (ZPA) conveyor controls, including the WTR1 and WTR2 sensors.
Covers · 2 models
The models it covers
Summary
What is in it
SICK technical information for the ZoneControl family of zero pressure accumulation (ZPA) conveyor controls. A preface explains accumulation conveyors, pneumatic and electric control, single and slug accumulation and release, power isolation, modules per tap and mounting locations. Product sections give features, dimensional drawings, connection diagrams, technical data and order numbers for the ZLM1 logic module, the WTR1 and WTR2 ZoneControl sensors, WLR2100 sensors, WTR2, ELF and W2000 photoelectric sensors, the ZIM interface module, power supply and accessories.
Its parts
- Zero Pressure Accumulation Preface
- ZLM1 ZoneControl Logic Module with Pneumatic Valve Output
- WTR1 ZoneControl Sensor with Pneumatic Valve Output
- WTR2 ZoneControl Sensor with Electric Motor Control Output
- WLR2100-D DC ZoneControl Sensor with Electric Output for External Valve or Electric Motor Control
- WLR2100-M AC ZoneControl Sensor with Electric Output for External Valve or Electric Motor Control
- WTR2 Photoelectric Diffuse Sensor with M12 Connector
- WTR2 Photoelectric Diffuse Sensor with Integral Cable
- ELF Photoelectric Retro-Reflective Sensor
- W2000 Photoelectric Retro-Reflective Sensor
- ZIM ZoneControl Interface Module
- ZoneControl Power Supply
- ZoneControl Accessories
From the manual
Key facts from this manual
Some pages are scans or cannot be read; this says only what the readable text supports. Each line names its page in the PDF.
A SICK technical information catalog for the ZoneControl zero pressure accumulation (ZPA) conveyor family. Besides the WTR1 and WTR2 sensors it lists the ZLM1, WLR2100-D, WLR2100-M, ELF and W2000 sensors, the ZIM interface module, a power supply and accessories. It explains accumulation and release modes and power tap wiring, and gives technical data, wiring diagrams and order numbers.
- Device
- ZoneControl ZPA conveyor sensors: WTR1 with pneumatic valve output, WTR2 with electric motor control output p. 2
- Sensing range
- 3.9 to 35.4 in (100 to 900 mm); background suppression adjustable 11.8 to 35.4 in (300 to 900 mm) p. 11, 13
- WTR1 power
- WTR1: 24 V DC +20/-10%, up to 67 mA with valve p. 11
- WTR2 power
- WTR2: 10 to 30 V DC p. 13, 19, 21
- Daisy chain
- WTR1 and WTR2-P621: 4-pin M12 female cable to the downstream sensor, 4-pin M12 male connector for the upstream one p. 11, 13
- WTR1 valve
- WTR1: 3/2 way, 24 V DC 1 W coil, quick connects 3/8” supply and 1/4” output, 0 to 4.5 bar (0 to 65 PSI) p. 11
- WTR2 output
- WTR2-P621: output to motor control or external valve, 600 mA max p. 13
- Logic modes
- WTR1: single or slug accumulation; WTR2-P621: single accumulation; both: single and slug release p. 11, 13
- Modules per tap
- WTR1 and WTR2-P621, Center Tap, 95 W source: 46 (3 ft zones) or 36 (6 ft zones) at 24 V; 48 at 28 V p. 11, 13
- WTR1 versions
- 3 ft zones: WTR1-P421A10, WTR1-P721A11, WTR1-P921A10, WTR1-P821A11; 6 ft zones: WTR1-P421B10, WTR1-P721B11, WTR1-P921B10, WTR1-P821B11 p. 11
- Operating temperature
- WTR1: 14 to 131°F (-10 to 55°C); WTR2: -40 to 140°F (-40 to 60°C) p. 11, 13, 19, 21
- Enclosure
- IP 54 p. 11, 13, 19, 21
- WTR2 diffuse outputs
- WTR2 diffuse sensors: PNP or NPN outputs, 200 mA max, M12 4-pin connector, flying leads or Wago 733-103 p. 18, 19, 20, 21
- Mounting brackets
- Mounting bracket, WTR: BEF-WN-WTR (2017417); bracket kit, WTR: MB-WTR-1 KIT (7029344) p. 35
What this manual walks you through
- Choosing single or slug accumulation and release p. 4, 5
- Planning End Tap, Center Tap and Dual Center Tap power wiring p. 5, 6
- Isolating power between chains on separate supplies p. 5
- Selecting a WTR1 model by zone length, accumulation mode and valve action p. 11
- Wiring the WTR1 daisy chain, release control and air supply p. 10
- Wiring the WTR2 output to a valve or motor control p. 13
- Wiring the WTR2 diffuse sensors p. 19, 21
- Choosing reflectors, cables and mounting brackets p. 32, 33, 35
Good to know
- Modules per tap figures assume a 95 W source at 24 or 28 V DC and a 2 m power supply cable for End and Center Tap. p. 6
- With slug release time delay, the release signal must be applied at the discharge zone. p. 5
- The WTR2-P621 output has no circuit protection. p. 13
- In the WTR1 wiring diagram, the slug release line applies to single accumulation models only. p. 10
Questions this manual answers
What voltage does the Sick WTR1 need?
24 V DC +20/-10%, drawing up to 67 mA with its valve. p. 11
What is the sensing range of the WTR1 and WTR2?
3.9 to 35.4 in (100 to 900 mm), with background suppression adjustable from 11.8 to 35.4 in. p. 11, 13
What is the difference between the WTR1 and WTR2 ZPA sensors?
The WTR1 has a pneumatic valve output; the WTR2 ZPA sensor has an electric motor control output. p. 2
How many WTR1 sensors can one power supply feed?
With a 95 W source on a Center Tap, 46 sensors in 3 ft zones or 36 in 6 ft zones at 24 V, and 48 at 28 V. p. 11
What air fittings does the WTR1 valve use?
Quick connects: 3/8” supply and 1/4” output, at 0 to 65 PSI. p. 11
The whole text · 4 parts
Read the manual here as text
Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.
The file