Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 1 of 4

Technical Information: ZoneControl Zero Pressure Accumulation, pages 1 to 9

Pages 1 to 9 of 36

The original document is the PDF (2.1 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Sick WTR1 and Sick WTR2

Page 1 read from a scan by OCR; it may hold reading errors

TECHNICAL INFORMATION

= cen ‘ijejel

_ A if ii

ZoneControl™ Zero Pressure Accumulation

SICK

Page 2

Table of Contents

Zero Pressure Accumulation Preface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 ZLM1 ZoneControl™ Logic Module with Pneumatic Valve Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 WTR1 ZoneControl™ Sensor with Pneumatic Valve Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8 WTR2 ZoneControl™ Sensor with Electric Motor Control Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10 WLR2100-D DC ZoneControl™ Sensor with Electric Output for External Valve or Electric Motor Control . . . . . . . . . . .12 WLR2100-M AC ZoneControl™ Sensor with Electric Output for External Valve or Electric Motor Control . . . . . . . . . . .14 WTR2 Photoelectric Diffuse Sensor with M12 Connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16 WTR2 Photoelectric Diffuse Sensor with Integral Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18 ELF Photoelectric Retro-Reflective Sensor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20 W2000 Photoelectric Retro-Reflective Sensor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22 ZIM ZoneControl™ Interface Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24 ZoneControl™ Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28 ZoneControl™ Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30

Page 3

Zero Pressure Accumulation Preface

What is an accumulation conveyor? An accumulation conveyor is a transportation conveyor designed to efficiently stage product when demand is low and deliver product when demand is high. An accumulation conveyor acts as the shock absorber in any distribution warehouse, logistics center or work-in-process operation. What is ZPA? Zero Pressure Accumulation (ZPA) is a more specific reference to an accumulation conveyor. A ZPA conveyor is designed to accumulate and release product with zero forward pressure on product. This results in a decreased risk of product damage or derailment. What is ZoneControl™? ZoneControl™ is the SICK family of ZPA control solutions. ZoneControl™ consists of integrated ZPA systems designed for accumulation conveyors and all the necessary peripherals and accessories to support the system. The ZoneControl™ family of products offer multiple ZPA solutions, all of which are similar in their function, but accommodate different types of conveyors by utilizing a variety of mounting configurations. What is an integrated solution? A ZPA control system typically consists of four primary components: a ZPA logic circuit, a pneumatic valve or other discrete output for motor control, a sensing device and daisy chain cabling. Integrated ZPA solutions generally integrate three or four of the primary components. Solutions which integrate only three of the components will have connectivity for the fourth component, usually the sensing device or pneumatic valve. How is accumulation control accomplished? Accumulation conveyors are designed with integral zones that are independently controlled. The individually controlled zones are activated or deactivated according the control logic circuit and sensor status at the local and neighboring zones. There are two basic types of ZPA control: pneumatic and electric. Pneumatic Control – AtoB and AtoD Accumulation conveyors that pneumatically actuate the drive system utilize small air bladders, often called pucks, to actuate the conveyor drive and/or brake system. When the logic circuit generates an output, a pneumatic solenoid valve is energized causing the valve to open or close. An open valve will allow air to flow and inflate the air bladder, a closed valve will prevent airflow to the bladder causing the bladder to exhaust and deflate. The air bladder, when inflated, will elevate a drive or brake system against the conveyor transportation medium respectively activating or deactivating the zone. A system that activates or drives the conveyor with airflow to the air bladder is referred to as air-to-drive (AtoD). A pneumatic system that deactivates or brakes the conveyor with airflow to the air bladder is referred to as air-to-brake (AtoB). Electric Control An electrically controlled accumulation conveyor utilizes individual electric motors to drive each zone. The logic circuit generates a discrete output to an electric motor drive circuit that activates the electric motor, in turn activating the zone. What accumulation modes are available with ZoneControl™? The most typical accumulation modes are single and slug accumulation; occasionally an accumulation time delay is used to manipulate product accumulation.

1

Page 4

Single accumulation will not allow a large block or slug of product to travel from the in-feed zone of an accumulation conveyor to the discharge zone without inflicting a gap between packages. Single accumulation will accumulate (deactivate) the upstream zone of any two consecutive zones that are detecting product, or in other words, any zone will accumulate when it is detecting product AND the downstream zone is detecting product. The result is a zone length gap between packages. The discharge zone does not have a downstream zone, which is effectively a full downstream zone; therefore, the discharge zone will accumulate when it receives a package. Single accumulation

Single accumulation 1 2 1

3 4

2

5

3 4

6 5

Full conveyor with product single accumulated

Pulling gaps between product

Slug accumulation will allow a large block or slug of product to travel uninterrupted from the in-feed zone of an accumulation conveyor to the furthest downstream zone, typically the discharge zone. The conveyor will not accumulate (deactivate) any zone until product reaches the furthest downstream zone at which time that zone will accumulate and the immediate upstream zone effectively becomes the furthest downstream zone. Slug accumulation

Slug accumulation 1

1

2

2

3

3

4

4

5

5

6

6

Slug of product traveling downstream uninterrupted

First two zones accumulated

Adjustable accumulation utilizes an adjustable accumulation time delay, that effectively delays package detection, which varies the accumulation function from single to slug. When the accumulation time delay is set to zero seconds, any package detection will be immediately recognized causing the upstream zone to accumulate (deactivate) in the same manner as single accumulation. As the time delay is increased, smaller packages will not be recognized and will advance until stopped by accumulated product downstream. As the stopped packages back-up into the sensing device, the accumulation time delay will time out causing the upstream zone to accumulate in a manner similar to slug accumulation. What release modes are available with ZoneControl™? The most typical release modes are single and slug release; occasionally time delays are used to manipulate product release. In single release mode, a given zone will not release (activate) until the sensing device in the downstream zone has been cleared of packages. Single release can be initiated by applying an electrical release signal at the discharge zone or removing packages in the discharge zone. Applying an electrical single release signal at the discharge zone will act as an empty downstream zone that will cause the discharge zone to release; the immediate upstream zone will not release until the discharge zone has cleared. Removal of packages from the discharge zone will cause that zone and the immediate upstream zone to release. Subsequent upstream zones will not release until the immediate downstream zone has cleared. Single release

Single release 1 1

2 2 3

3

4

4 5

5 6

6f

Downstream zone clears, upstream zone activates

Conveyor single accumulated

2

Page 5

Single release time delay will add an additional gap between zones as they are released. The additional gap is directly proportional to the time delay selected. In slug release mode, all zones will be activated simultaneously, regardless of sensor status, for as long as the slug release signal is applied. Slug release is initiated by applying an electrical signal at any zone using a ZoneControl™ Tee cable or Zone Interface Module (ZIM). Slug release

Slug release 1

1 2

2 3

3

4

4

5

5

6

6

Slug release signal applied, entire conveyor releasing

Conveyor single accumulated

Slug release time delay will inflict a small gap between zones as they are released. The small gap is directly proportional to the time delay selected. When applying a ZoneControl™ solution with slug release time delay, the release signal must be applied at the discharge zone. When are single and slug modes most commonly used? Single accumulation and release is most effective when extremely high throughput is not necessary or the risk of forward pressure is not acceptable. Large or heavy products are frequently accumulated and released in single mode. Slug accumulation and release is most effective when extremely high throughput is desired and instances of low momentary forward pressure can be tolerated. High speed conveying with small to medium package sizes are often accumulated and released in slug mode. What is slug release termination? In some applications it is necessary to terminate a slug release signal after a determined number of zones. Slug release termination interrupts the slug release signal by opening the slug release wire. Slug release termination is accomplished with an inline cable that does not pass the slug signal; all other conductors are passive. Or, slug release termination can be accomplished with a ZPA Interface Module (ZIM). The slug termination cable and ZPA Interface Module (ZIM) are offered in the ZoneControl™ family of products. Power Isolation Power isolation is necessary when more than one power supply is used on a ZPA control system. Power isolation interrupts the positive voltage supply line between two ZPA chains on separate power supplies. Power isolation is accomplished with an in-line cable that does not pass the positive supply voltage; all other conductors are passive. See examples on the following page. Modules per Tap There is a limit to the number of ZoneControl™ devices that can be connected in series (chain) before an additional power supply and power isolation unit are required. This limit is known as the “Modules per Tap” specification. The number of Modules per Tap will vary from one ZPA solution to another and is affected primarily by the power source, pneumatic valve or output load, and daisy chain cabling. There are three common wiring schemes for ZPA systems: End Tap, Center Tap and Dual Center Tap.

3

Page 6

All ZoneControl™ “Modules per Tap” specifications are calculated using a 95 W power source, 24 and 28 V DC and 2 m power supply cable for End Tap and Center Tap. Dual Center Tap is calculated using the appropriate power supply cable length for the chain. The End Tap wiring scheme positions the power source at one end of a ZPA chain, typically the discharge end. A short power cable is used to connect the power source to the first ZPA module. When using End Tap wiring a 28 V DC power source will accommodate the most modules per chain. End Tap wiring is most effective when the ZPA system requires a relatively small number of modules or when a small number of modules remain unpowered on a large ZPA system that uses Center Tap wiring. Total number of modules in a chain per End Tap

Power isolation cable

Module powered by a secondary power source

Power source

The Center Tap wiring scheme positions the power source at the center point of a ZPA chain. A short cable with an attached Tee cable is used to connect the power source to the ZPA chain between two modules. This Center Tap supplies power to the chain in both directions. The Center Tap configuration is the simplest and most common installation for wiring the power source to ZPA systems. Power isolation cable

Module powered by a secondary power source

Total number of modules in a chain, evenly distributed about the Center Tap

Power source

T-cable

Power isolation cable

Module powered by a secondary power source

The Dual Center Tap wiring scheme positions the power source at the center point of a ZPA chain. Two long cables with attached Tee cables are used to apply a Center Tap at the mid point between the power source and the end of the ZPA chain in both directions, hence, Dual Center Tap. When using Dual Center Tap wiring a 24 V DC power source will accommodate the most modules per chain. Power isolation cable

Module powered by a secondary power source

Power isolation cable

Total number of modules in a chain, evenly distributed about each Center Tap

T-cable

T-cable

Module powered by a secondary power source

Power source

Zone Size Zone size is the length of an individual zone within an accumulation conveyor. Typically, an accumulation conveyor has two, three or six foot zones. Mounting Location In general, there are three basic locations where the sensing device of a ZPA system can be located or mounted to the accumulation conveyor: Over-the-Conveyor, Under-the-Conveyor or Side-Frame-Mount. The ZoneControl™ family of products offers multiple solutions and each can be easily mounted in one of the three basic locations. Over-the-Conveyor

Under-the-Conveyor

Side-Frame-Mount Bolt-on

Clip-on

4

Page 7

ZLM1 ZoneControl™ Logic Module with Pneumatic Valve Output

C

US

R

ESPE LISTED 665N

Dimensional Drawings

Features

Bolt-on 2.9 (74) WINGSPAN

■ Side-Frame-Mount ■ Integrated ZPA logic, pneumatic valve, daisy chain cables and sensor cable ■ American style valve with Imperial size quick connect fittings ■ Connection cable for standard sensor, mounted remotely ■ Single or slug accumulation logic ■ Single or slug release logic

1.2 (31)

1.6 (41)

3.3 (83)

0.4 (10)

6

8

1

0.8 (12) 0.6 (15)

6

7

1.5 (39)

0.3 (7)

4.3 (110)

3.2 (80)

5

4.3 (110)

7 5

2

4.3 (110)

2.5 (63)

2

2 3

3

4

4

1.8 (45)

3 0.6 (16)

1

4 1.2 (31)

ø1/4" AIR HOSE

1.8 (45)

■ Industrial grade M12 daisy chain cables

ø3/8" AIR HOSE

Clip-on 2.8 (70)

1.8 (45) WINGSPAN

8

1

8 0.6 (15)

11

1.9 (49)

7

1.0 (25)

7

4.3 (110)

10 5 ø0.4 (10) (2)

2

0.4 (10)

Bolt-on

9

3.2 (80)

5

3.2 (81)

0.4 (10)

0.3 (8)

2.5 (63)

2

2 3

3

4

4

1.8 (45)

4.3 (110) 3

0.6 (16)

1

4

1.2 (30)

ø1/4" AIR HOSE

1.8 (46)

ø3/8" AIR HOSE dimensions in inches (mm) 1 2 3 4 5

Daisy chain connector, male

6

Mounting slots (x2)

7 8 9 10

Exhaust Output port (x2) Supply ports (x2)

Daisy chain cable, female Sensor connection cable, female Clip-on

Mounting stud

Anti-rotation stud 11 Mounting clip

Manual over-ride switch

Connection Diagram

+ V DC 0 V DC Single release* Slug release Air supply

L+ M E Vt

1 3 2 4

Release Logic in out

1 3 2 4

L+ M E Vt valve

NC

M12 Male Downstream

1

1

M12 Female Upstream 2

4

4

3

0 DC Output

Product flow

Downstream

Release control

+ V DC

2

1 2 3 4

3 Release Logic Out in valve Output to conveyor

*Single accumulation models only

5

Page 8

ZLM1

Technical Data

ZLM1-

C

B

Power Supply voltage Vs

24 V DC +20/-10%

Ripple

< 5 Vss within Vs

Current consumption

≤ 47 mA with valve, without sensor

Sensor Photoelectric sensor connection type

Cable: 0.5 m, 4-pin M8 or M12 female, (connects to sensing device - sold separately)

Photoelectric sensor output requirements

PNP, light operate retro-reflective or dark operate diffuse (prox), 20 mA typical

Interconnection Logic output type

PNP

Logic output voltage

Single accumulation mode: beam blocked = 0 V, beam unblocked = Vs - (≤ 2 V) Slug accumulation mode: D.S. zone activated = Vs - (≤ 2 V), D.S. zone deactive = 0 V

Logic output current max.

100 mA

Logic output switching frequency/response time 200 Hz/2.5 ms Daisy chain connection type

Connector: 4-pin M12 male (connects to downstream sensor) Cable: 1.1 m or 2.1 m, 4-pin M12 female (connects to upstream sensor)

Circuit protection

Short circuit protection; interference pulse suppression; Vs reverse polarity protected

Modules per End Tap (95 W source)

24 Vs: 3 ft zones = 26, 6 ft zones = 20

28 Vs: 3 ft zones = 35, 6 ft zones = 27

Modules per Center Tap (95 W source)

24 Vs: 3 ft zones = 52, 6 ft zones = 40

28 Vs: 3 ft zones = 46, 6 ft zones = 46

Modules per Dual Center Tap (95 W source)

24 Vs: 3 ft zones = 60, 6 ft zones = 52

28 Vs: 3 ft zones = N/A, 6 ft zones = N/A

Logic function Accumulation mode1)

Single or slug

Release mode1)

Single (signal applied at discharge zone) and/or slug (signal applied anywhere along chain)

Valve Compressed air

Filtered, lubricated or unlubricated

Operation mode1)

AtoD (Air to Drive) or AtoB (Air to Brake)

Pneumatic circuit function

3/2 way

Port connections

Quick connect: 3/8” supply; 1/4” output (connects to local zone)

Coil ratings

24 V DC, 1 W

Output flow rate

40 NI/min; 1.4 SCFM

Exhaust flow rate

40 NI/min; 1.4 SCFM

Orifice size

0.047 in (1.2 mm)

Operating pressure range

0…4.5 bar (0…65 PSI)

Response time

Partially open: 10 ms; open: 23 ms; close: 21 ms

Physical properties Protection class Enclosure rating

IP 40, NEMA 2

Ambient operating temperature

14…131°F (-10…55°C)

Storage temperature

-40…167°F (-40…75°C)

Shock load

IEC 68

Approximate weight

5.9 oz (168 g) with 1.1 m cable; 7.3 oz (206 g) with 2.1 m cable: 4.1 oz (115 g) no daisy chain cable

Housing material

ABS

Fastening method

Clip-on

Typical mounting location

Side-Frame-Mount

Bolt-on

1) Model selectable, refer to selection table on following page

6

Page 9

ZLM1 ZLM1 Clip-on Mounting Zone Length

Sensor Connection

Single Accumulation - Single and Slug Release AtoD AtoB

Slug Accumulation - Slug Release AtoD AtoB

3 ft cable M8

ZLM1-C1121A10

ZLM1-C1121A11

ZLM1-C2121A10

ZLM1-C2121A11

3 ft cable M12

ZLM1-C1111A10

ZLM1-C1111A11

ZLM1-C2111A10

ZLM1-C2111A11

6 ft cable M8

ZLM1-C1221A10

ZLM1-C1221A11

ZLM1-C2221A10

ZLM1-C2221A11

6 ft cable M12

ZLM1-C1211A10

ZLM1-C1211A11

ZLM1-C2211A10

ZLM1-C2211A11

M12 male connector connector M8

ZLM1-C1021A10

ZLM1-C1021A11

ZLM1-C2021A10

ZLM1-C2021A11

M12 male connector connector M12

ZLM1-C1011A10

ZLM1-C1011A11

ZLM1-C2011A10

ZLM1-C2011A11

ZLM1 Bolt-on Mounting Zone Length

Sensor Connection

Single Accumulation - Single and Slug Release AtoD AtoB

Slug Accumulation - Slug Release AtoD AtoB

3 ft cable M8

ZLM1-B1121A10

ZLM1-B1121A11

ZLM1-B2121A10

ZLM1-B2121A11

3 ft cable M12

ZLM1-B1111A10

ZLM1-B1111A11

ZLM1-B2111A10

ZLM1-B2111A11

6 ft cable M8

ZLM1-B1221A10

ZLM1-B1221A11

ZLM1-B2221A10

ZLM1-B2221A11

6 ft cable M12

ZLM1-B1211A10

ZLM1-B1211A11

ZLM1-B2211A10

ZLM1-B2211A11

M12 male connector connector M8

ZLM1-B1021A10

ZLM1-B1021A11

ZLM1-B2021A10

ZLM1-B2021A11

M12 male connector connector M12

ZLM1-B1011A10

ZLM1-B1011A11

ZLM1-B2011A10

ZLM1-B2011A11

Order Information Model Number ZLM1-C1121A10 ZLM1-C1121A11 ZLM1-C2121A10 ZLM1-C2121A11 ZLM1-B1121A10 ZLM1-B1121A11 ZLM 1-B2121A10 ZLM 1-B2121A11

Part Number 7027756 7027757 7027758 7027759 7027760 7027761 7027762 7027763

Model Number ZLM1-C1111A10 ZLM1-C1111A11 ZLM1-C2111A10 ZLM1-C2111A11 ZLM1-B1111A10 ZLM1-B1111A11 ZLM1-B2111A10 ZLM1-B2111A11

Part Number 7027764 7027765 7027766 7027767 7027768 7027769 7027770 7027771

Model Number ZLM1-C1221A10 ZLM1-C1221A11 ZLM1-C2221A10 ZLM1-C2221A11 ZLM1-B1221A10 ZLM1-B1221A11 ZLM1-B2221A10 ZLM1-B2221A11

Part Number 7027772 7027773 7027774 7027775 7027776 7027777 7027778 7027779

Model Number ZLM1-C1211A10 ZLM1-C1211A11 ZLM1-C2211A10 ZLM1-C2211A11 ZLM1-B1211A10 ZLM1-B1211A11 ZLM1-B2211A10 ZLM1-B2211A11

Part Number 7027780 7027781 7027782 7027783 7027784 7027785 7027786 7027787

Model Number ZLM1-C1021A10 ZLM1-C1021A11 ZLM1-C2021A10 ZLM1-C2021A11 ZLM1-B1021A10 ZLM1-B1021A11 ZLM1-B2021A10 ZLM1-B2021A11

Part Number 7027788 7027789 7027790 7027791 7027792 7027793 7027794 7027795

Model Number ZLM1-C1011A10 ZLM1-C1011A11 ZLM1-C2011A10 ZLM1-C2011A11 ZLM1-B1011A10 ZLM1-B1011A11 ZLM1-B2011A10 ZLM1-B2011A11

Part Number 7027796 7027797 7027798 7027799 7027800 7027801 7027802 7027803

Accessories

Page

Reflectors

30

Cables

31

Mounting brackets

33

Interface module

24

7