The text of a manual · part 1 of 4
Technical Information: ZoneControl Zero Pressure Accumulation, pages 1 to 9
Pages 1 to 9 of 36
The original document is the PDF (2.1 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
Page 1
TECHNICAL INFORMATION
= cen ‘ijejel
_ A if ii
ZoneControl™ Zero Pressure Accumulation
SICK
Page 2
Table of Contents
Zero Pressure Accumulation Preface . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1 ZLM1 ZoneControl™ Logic Module with Pneumatic Valve Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 WTR1 ZoneControl™ Sensor with Pneumatic Valve Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8 WTR2 ZoneControl™ Sensor with Electric Motor Control Output . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10 WLR2100-D DC ZoneControl™ Sensor with Electric Output for External Valve or Electric Motor Control . . . . . . . . . . .12 WLR2100-M AC ZoneControl™ Sensor with Electric Output for External Valve or Electric Motor Control . . . . . . . . . . .14 WTR2 Photoelectric Diffuse Sensor with M12 Connector . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16 WTR2 Photoelectric Diffuse Sensor with Integral Cable . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18 ELF Photoelectric Retro-Reflective Sensor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .20 W2000 Photoelectric Retro-Reflective Sensor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22 ZIM ZoneControl™ Interface Module . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .24 ZoneControl™ Power Supply . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28 ZoneControl™ Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .30
Page 3
Zero Pressure Accumulation Preface
What is an accumulation conveyor? An accumulation conveyor is a transportation conveyor designed to efficiently stage product when demand is low and deliver product when demand is high. An accumulation conveyor acts as the shock absorber in any distribution warehouse, logistics center or work-in-process operation. What is ZPA? Zero Pressure Accumulation (ZPA) is a more specific reference to an accumulation conveyor. A ZPA conveyor is designed to accumulate and release product with zero forward pressure on product. This results in a decreased risk of product damage or derailment. What is ZoneControl™? ZoneControl™ is the SICK family of ZPA control solutions. ZoneControl™ consists of integrated ZPA systems designed for accumulation conveyors and all the necessary peripherals and accessories to support the system. The ZoneControl™ family of products offer multiple ZPA solutions, all of which are similar in their function, but accommodate different types of conveyors by utilizing a variety of mounting configurations. What is an integrated solution? A ZPA control system typically consists of four primary components: a ZPA logic circuit, a pneumatic valve or other discrete output for motor control, a sensing device and daisy chain cabling. Integrated ZPA solutions generally integrate three or four of the primary components. Solutions which integrate only three of the components will have connectivity for the fourth component, usually the sensing device or pneumatic valve. How is accumulation control accomplished? Accumulation conveyors are designed with integral zones that are independently controlled. The individually controlled zones are activated or deactivated according the control logic circuit and sensor status at the local and neighboring zones. There are two basic types of ZPA control: pneumatic and electric. Pneumatic Control – AtoB and AtoD Accumulation conveyors that pneumatically actuate the drive system utilize small air bladders, often called pucks, to actuate the conveyor drive and/or brake system. When the logic circuit generates an output, a pneumatic solenoid valve is energized causing the valve to open or close. An open valve will allow air to flow and inflate the air bladder, a closed valve will prevent airflow to the bladder causing the bladder to exhaust and deflate. The air bladder, when inflated, will elevate a drive or brake system against the conveyor transportation medium respectively activating or deactivating the zone. A system that activates or drives the conveyor with airflow to the air bladder is referred to as air-to-drive (AtoD). A pneumatic system that deactivates or brakes the conveyor with airflow to the air bladder is referred to as air-to-brake (AtoB). Electric Control An electrically controlled accumulation conveyor utilizes individual electric motors to drive each zone. The logic circuit generates a discrete output to an electric motor drive circuit that activates the electric motor, in turn activating the zone. What accumulation modes are available with ZoneControl™? The most typical accumulation modes are single and slug accumulation; occasionally an accumulation time delay is used to manipulate product accumulation.
1
Page 4
Single accumulation will not allow a large block or slug of product to travel from the in-feed zone of an accumulation conveyor to the discharge zone without inflicting a gap between packages. Single accumulation will accumulate (deactivate) the upstream zone of any two consecutive zones that are detecting product, or in other words, any zone will accumulate when it is detecting product AND the downstream zone is detecting product. The result is a zone length gap between packages. The discharge zone does not have a downstream zone, which is effectively a full downstream zone; therefore, the discharge zone will accumulate when it receives a package. Single accumulation
Single accumulation 1 2 1
3 4
2
5
3 4
6 5
Full conveyor with product single accumulated
Pulling gaps between product
Slug accumulation will allow a large block or slug of product to travel uninterrupted from the in-feed zone of an accumulation conveyor to the furthest downstream zone, typically the discharge zone. The conveyor will not accumulate (deactivate) any zone until product reaches the furthest downstream zone at which time that zone will accumulate and the immediate upstream zone effectively becomes the furthest downstream zone. Slug accumulation
Slug accumulation 1
1
2
2
3
3
4
4
5
5
6
6
Slug of product traveling downstream uninterrupted
First two zones accumulated
Adjustable accumulation utilizes an adjustable accumulation time delay, that effectively delays package detection, which varies the accumulation function from single to slug. When the accumulation time delay is set to zero seconds, any package detection will be immediately recognized causing the upstream zone to accumulate (deactivate) in the same manner as single accumulation. As the time delay is increased, smaller packages will not be recognized and will advance until stopped by accumulated product downstream. As the stopped packages back-up into the sensing device, the accumulation time delay will time out causing the upstream zone to accumulate in a manner similar to slug accumulation. What release modes are available with ZoneControl™? The most typical release modes are single and slug release; occasionally time delays are used to manipulate product release. In single release mode, a given zone will not release (activate) until the sensing device in the downstream zone has been cleared of packages. Single release can be initiated by applying an electrical release signal at the discharge zone or removing packages in the discharge zone. Applying an electrical single release signal at the discharge zone will act as an empty downstream zone that will cause the discharge zone to release; the immediate upstream zone will not release until the discharge zone has cleared. Removal of packages from the discharge zone will cause that zone and the immediate upstream zone to release. Subsequent upstream zones will not release until the immediate downstream zone has cleared. Single release
Single release 1 1
2 2 3
3
4
4 5
5 6
6f
Downstream zone clears, upstream zone activates
Conveyor single accumulated
2
Page 5
Single release time delay will add an additional gap between zones as they are released. The additional gap is directly proportional to the time delay selected. In slug release mode, all zones will be activated simultaneously, regardless of sensor status, for as long as the slug release signal is applied. Slug release is initiated by applying an electrical signal at any zone using a ZoneControl™ Tee cable or Zone Interface Module (ZIM). Slug release
Slug release 1
1 2
2 3
3
4
4
5
5
6
6
Slug release signal applied, entire conveyor releasing
Conveyor single accumulated
Slug release time delay will inflict a small gap between zones as they are released. The small gap is directly proportional to the time delay selected. When applying a ZoneControl™ solution with slug release time delay, the release signal must be applied at the discharge zone. When are single and slug modes most commonly used? Single accumulation and release is most effective when extremely high throughput is not necessary or the risk of forward pressure is not acceptable. Large or heavy products are frequently accumulated and released in single mode. Slug accumulation and release is most effective when extremely high throughput is desired and instances of low momentary forward pressure can be tolerated. High speed conveying with small to medium package sizes are often accumulated and released in slug mode. What is slug release termination? In some applications it is necessary to terminate a slug release signal after a determined number of zones. Slug release termination interrupts the slug release signal by opening the slug release wire. Slug release termination is accomplished with an inline cable that does not pass the slug signal; all other conductors are passive. Or, slug release termination can be accomplished with a ZPA Interface Module (ZIM). The slug termination cable and ZPA Interface Module (ZIM) are offered in the ZoneControl™ family of products. Power Isolation Power isolation is necessary when more than one power supply is used on a ZPA control system. Power isolation interrupts the positive voltage supply line between two ZPA chains on separate power supplies. Power isolation is accomplished with an in-line cable that does not pass the positive supply voltage; all other conductors are passive. See examples on the following page. Modules per Tap There is a limit to the number of ZoneControl™ devices that can be connected in series (chain) before an additional power supply and power isolation unit are required. This limit is known as the “Modules per Tap” specification. The number of Modules per Tap will vary from one ZPA solution to another and is affected primarily by the power source, pneumatic valve or output load, and daisy chain cabling. There are three common wiring schemes for ZPA systems: End Tap, Center Tap and Dual Center Tap.
3
Page 6
All ZoneControl™ “Modules per Tap” specifications are calculated using a 95 W power source, 24 and 28 V DC and 2 m power supply cable for End Tap and Center Tap. Dual Center Tap is calculated using the appropriate power supply cable length for the chain. The End Tap wiring scheme positions the power source at one end of a ZPA chain, typically the discharge end. A short power cable is used to connect the power source to the first ZPA module. When using End Tap wiring a 28 V DC power source will accommodate the most modules per chain. End Tap wiring is most effective when the ZPA system requires a relatively small number of modules or when a small number of modules remain unpowered on a large ZPA system that uses Center Tap wiring. Total number of modules in a chain per End Tap
Power isolation cable
Module powered by a secondary power source
Power source
The Center Tap wiring scheme positions the power source at the center point of a ZPA chain. A short cable with an attached Tee cable is used to connect the power source to the ZPA chain between two modules. This Center Tap supplies power to the chain in both directions. The Center Tap configuration is the simplest and most common installation for wiring the power source to ZPA systems. Power isolation cable
Module powered by a secondary power source
Total number of modules in a chain, evenly distributed about the Center Tap
Power source
T-cable
Power isolation cable
Module powered by a secondary power source
The Dual Center Tap wiring scheme positions the power source at the center point of a ZPA chain. Two long cables with attached Tee cables are used to apply a Center Tap at the mid point between the power source and the end of the ZPA chain in both directions, hence, Dual Center Tap. When using Dual Center Tap wiring a 24 V DC power source will accommodate the most modules per chain. Power isolation cable
Module powered by a secondary power source
Power isolation cable
Total number of modules in a chain, evenly distributed about each Center Tap
T-cable
T-cable
Module powered by a secondary power source
Power source
Zone Size Zone size is the length of an individual zone within an accumulation conveyor. Typically, an accumulation conveyor has two, three or six foot zones. Mounting Location In general, there are three basic locations where the sensing device of a ZPA system can be located or mounted to the accumulation conveyor: Over-the-Conveyor, Under-the-Conveyor or Side-Frame-Mount. The ZoneControl™ family of products offers multiple solutions and each can be easily mounted in one of the three basic locations. Over-the-Conveyor
Under-the-Conveyor
Side-Frame-Mount Bolt-on
Clip-on
4
Page 7
ZLM1 ZoneControl™ Logic Module with Pneumatic Valve Output
C
US
R
ESPE LISTED 665N
Dimensional Drawings
Features
Bolt-on 2.9 (74) WINGSPAN
■ Side-Frame-Mount ■ Integrated ZPA logic, pneumatic valve, daisy chain cables and sensor cable ■ American style valve with Imperial size quick connect fittings ■ Connection cable for standard sensor, mounted remotely ■ Single or slug accumulation logic ■ Single or slug release logic
1.2 (31)
1.6 (41)
3.3 (83)
0.4 (10)
6
8
1
0.8 (12) 0.6 (15)
6
7
1.5 (39)
0.3 (7)
4.3 (110)
3.2 (80)
5
4.3 (110)
7 5
2
4.3 (110)
2.5 (63)
2
2 3
3
4
4
1.8 (45)
3 0.6 (16)
1
4 1.2 (31)
ø1/4" AIR HOSE
1.8 (45)
■ Industrial grade M12 daisy chain cables
ø3/8" AIR HOSE
Clip-on 2.8 (70)
1.8 (45) WINGSPAN
8
1
8 0.6 (15)
11
1.9 (49)
7
1.0 (25)
7
4.3 (110)
10 5 ø0.4 (10) (2)
2
0.4 (10)
Bolt-on
9
3.2 (80)
5
3.2 (81)
0.4 (10)
0.3 (8)
2.5 (63)
2
2 3
3
4
4
1.8 (45)
4.3 (110) 3
0.6 (16)
1
4
1.2 (30)
ø1/4" AIR HOSE
1.8 (46)
ø3/8" AIR HOSE dimensions in inches (mm) 1 2 3 4 5
Daisy chain connector, male
6
Mounting slots (x2)
7 8 9 10
Exhaust Output port (x2) Supply ports (x2)
Daisy chain cable, female Sensor connection cable, female Clip-on
Mounting stud
Anti-rotation stud 11 Mounting clip
Manual over-ride switch
Connection Diagram
+ V DC 0 V DC Single release* Slug release Air supply
L+ M E Vt
1 3 2 4
Release Logic in out
1 3 2 4
L+ M E Vt valve
NC
M12 Male Downstream
1
1
M12 Female Upstream 2
4
4
3
0 DC Output
Product flow
Downstream
Release control
+ V DC
2
1 2 3 4
3 Release Logic Out in valve Output to conveyor
*Single accumulation models only
5
Page 8
ZLM1
Technical Data
ZLM1-
C
B
Power Supply voltage Vs
24 V DC +20/-10%
Ripple
< 5 Vss within Vs
Current consumption
≤ 47 mA with valve, without sensor
Sensor Photoelectric sensor connection type
Cable: 0.5 m, 4-pin M8 or M12 female, (connects to sensing device - sold separately)
Photoelectric sensor output requirements
PNP, light operate retro-reflective or dark operate diffuse (prox), 20 mA typical
Interconnection Logic output type
PNP
Logic output voltage
Single accumulation mode: beam blocked = 0 V, beam unblocked = Vs - (≤ 2 V) Slug accumulation mode: D.S. zone activated = Vs - (≤ 2 V), D.S. zone deactive = 0 V
Logic output current max.
100 mA
Logic output switching frequency/response time 200 Hz/2.5 ms Daisy chain connection type
Connector: 4-pin M12 male (connects to downstream sensor) Cable: 1.1 m or 2.1 m, 4-pin M12 female (connects to upstream sensor)
Circuit protection
Short circuit protection; interference pulse suppression; Vs reverse polarity protected
Modules per End Tap (95 W source)
24 Vs: 3 ft zones = 26, 6 ft zones = 20
28 Vs: 3 ft zones = 35, 6 ft zones = 27
Modules per Center Tap (95 W source)
24 Vs: 3 ft zones = 52, 6 ft zones = 40
28 Vs: 3 ft zones = 46, 6 ft zones = 46
Modules per Dual Center Tap (95 W source)
24 Vs: 3 ft zones = 60, 6 ft zones = 52
28 Vs: 3 ft zones = N/A, 6 ft zones = N/A
Logic function Accumulation mode1)
Single or slug
Release mode1)
Single (signal applied at discharge zone) and/or slug (signal applied anywhere along chain)
Valve Compressed air
Filtered, lubricated or unlubricated
Operation mode1)
AtoD (Air to Drive) or AtoB (Air to Brake)
Pneumatic circuit function
3/2 way
Port connections
Quick connect: 3/8” supply; 1/4” output (connects to local zone)
Coil ratings
24 V DC, 1 W
Output flow rate
40 NI/min; 1.4 SCFM
Exhaust flow rate
40 NI/min; 1.4 SCFM
Orifice size
0.047 in (1.2 mm)
Operating pressure range
0…4.5 bar (0…65 PSI)
Response time
Partially open: 10 ms; open: 23 ms; close: 21 ms
Physical properties Protection class Enclosure rating
IP 40, NEMA 2
Ambient operating temperature
14…131°F (-10…55°C)
Storage temperature
-40…167°F (-40…75°C)
Shock load
IEC 68
Approximate weight
5.9 oz (168 g) with 1.1 m cable; 7.3 oz (206 g) with 2.1 m cable: 4.1 oz (115 g) no daisy chain cable
Housing material
ABS
Fastening method
Clip-on
Typical mounting location
Side-Frame-Mount
Bolt-on
1) Model selectable, refer to selection table on following page
6
Page 9
ZLM1 ZLM1 Clip-on Mounting Zone Length
Sensor Connection
Single Accumulation - Single and Slug Release AtoD AtoB
Slug Accumulation - Slug Release AtoD AtoB
3 ft cable M8
ZLM1-C1121A10
ZLM1-C1121A11
ZLM1-C2121A10
ZLM1-C2121A11
3 ft cable M12
ZLM1-C1111A10
ZLM1-C1111A11
ZLM1-C2111A10
ZLM1-C2111A11
6 ft cable M8
ZLM1-C1221A10
ZLM1-C1221A11
ZLM1-C2221A10
ZLM1-C2221A11
6 ft cable M12
ZLM1-C1211A10
ZLM1-C1211A11
ZLM1-C2211A10
ZLM1-C2211A11
M12 male connector connector M8
ZLM1-C1021A10
ZLM1-C1021A11
ZLM1-C2021A10
ZLM1-C2021A11
M12 male connector connector M12
ZLM1-C1011A10
ZLM1-C1011A11
ZLM1-C2011A10
ZLM1-C2011A11
ZLM1 Bolt-on Mounting Zone Length
Sensor Connection
Single Accumulation - Single and Slug Release AtoD AtoB
Slug Accumulation - Slug Release AtoD AtoB
3 ft cable M8
ZLM1-B1121A10
ZLM1-B1121A11
ZLM1-B2121A10
ZLM1-B2121A11
3 ft cable M12
ZLM1-B1111A10
ZLM1-B1111A11
ZLM1-B2111A10
ZLM1-B2111A11
6 ft cable M8
ZLM1-B1221A10
ZLM1-B1221A11
ZLM1-B2221A10
ZLM1-B2221A11
6 ft cable M12
ZLM1-B1211A10
ZLM1-B1211A11
ZLM1-B2211A10
ZLM1-B2211A11
M12 male connector connector M8
ZLM1-B1021A10
ZLM1-B1021A11
ZLM1-B2021A10
ZLM1-B2021A11
M12 male connector connector M12
ZLM1-B1011A10
ZLM1-B1011A11
ZLM1-B2011A10
ZLM1-B2011A11
Order Information Model Number ZLM1-C1121A10 ZLM1-C1121A11 ZLM1-C2121A10 ZLM1-C2121A11 ZLM1-B1121A10 ZLM1-B1121A11 ZLM 1-B2121A10 ZLM 1-B2121A11
Part Number 7027756 7027757 7027758 7027759 7027760 7027761 7027762 7027763
Model Number ZLM1-C1111A10 ZLM1-C1111A11 ZLM1-C2111A10 ZLM1-C2111A11 ZLM1-B1111A10 ZLM1-B1111A11 ZLM1-B2111A10 ZLM1-B2111A11
Part Number 7027764 7027765 7027766 7027767 7027768 7027769 7027770 7027771
Model Number ZLM1-C1221A10 ZLM1-C1221A11 ZLM1-C2221A10 ZLM1-C2221A11 ZLM1-B1221A10 ZLM1-B1221A11 ZLM1-B2221A10 ZLM1-B2221A11
Part Number 7027772 7027773 7027774 7027775 7027776 7027777 7027778 7027779
Model Number ZLM1-C1211A10 ZLM1-C1211A11 ZLM1-C2211A10 ZLM1-C2211A11 ZLM1-B1211A10 ZLM1-B1211A11 ZLM1-B2211A10 ZLM1-B2211A11
Part Number 7027780 7027781 7027782 7027783 7027784 7027785 7027786 7027787
Model Number ZLM1-C1021A10 ZLM1-C1021A11 ZLM1-C2021A10 ZLM1-C2021A11 ZLM1-B1021A10 ZLM1-B1021A11 ZLM1-B2021A10 ZLM1-B2021A11
Part Number 7027788 7027789 7027790 7027791 7027792 7027793 7027794 7027795
Model Number ZLM1-C1011A10 ZLM1-C1011A11 ZLM1-C2011A10 ZLM1-C2011A11 ZLM1-B1011A10 ZLM1-B1011A11 ZLM1-B2011A10 ZLM1-B2011A11
Part Number 7027796 7027797 7027798 7027799 7027800 7027801 7027802 7027803
Accessories
Page
Reflectors
30
Cables
31
Mounting brackets
33
Interface module
24
7