The text of a manual · part 4 of 4
Technical Information: ZoneControl Zero Pressure Accumulation, pages 28 to 36
Pages 28 to 36 of 36
The original document is the PDF (2.1 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
Page 28
ZIM-2 Applications The following rules apply to the following applications. • All references of upstream or downstream are given with respect to the ZIM • Factory default jumper (JPx) position is 1-2 • Jumpers (JPx) other than those referenced in a given application note have no influence on that application Single Release Action: Upstream Logic Module releases despite upstream and downstream zone status. Isolated AC/DC Configuration: Apply a high (ON) signal input to TB1 terminals when JP3 is on 1-2. Non-isolated DC Configuration: Apply a high (ON) signal input to TB4 terminal 3 when JP4 is on 1-2. Slug Release Action: All Logic Modules connected to the Slug line will release regardless of zone status or accumulation status. (see Logic Crossover configuration for exception) Slug Interrupt/Isolator should be used to limit the number of logic modules slug released by a single ZIM module to 80 logic modules across no more than 2 power supplies. If more than 2 power supplies or more than 80 logic modules are to be slug released, use an additional ZIM to release the additional logic modules. If the logic modules use 2 power supplies, reduce the “modules per tap” maximum by 3 for the power tap section supplying the ZIM. Isolated AC/DC Configuration: Apply a high signal level (ON) to TB2 with JP1 on 1-2 and JP3 on 1-2. Logic Crossover Configuration: The downstream logic release signal (downstream logic line ON) is crossed-over to the upstream slug release line when JP1 is on 4-5 and JP2 is on 2-3. Pulse Release Action: Upstream Logic Module releases for a duration of time set by ZS ON (0-20 s) and then accumulates for a duration of time set by ZS OFF (0-20 s), despite upstream and downstream zone status. Isolated AC/DC Configuration: Apply a high signal (ON) to TB1 when JP3 is removed. Adjustability: Release time is set by ZS ON potentiometer from 0 to 20 seconds. Accumulation time is set by ZS OFF potentiometer from 0 to 20 seconds. Zone Release Delay (Logic Line Delay) Action: Upstream logic module will release after the downstream zone has cleared and the logic delay has expired. Adjustability: Adjust LOGIC potentiometer from 0 to 20 seconds. Logic Interrupt/Stop Zone Action: Upstream logic module accumulates when the upstream Logic Module detects a package, despite downstream zone status. Isolated AC/DC Configuration: Apply a low (OFF) signal input to TB1 when JP3 is on 2-3. Non-isolated DC Configuration: Apply a low (OFF) signal input to TB4 when JP4 is on 2-3. Downstream Slug Interrupt Action: Downstream Logic Modules will not slug release when Slug Release is initiated at the ZIM or upstream of the ZIM. Configuration: JP1 is on 2-3 and JP2 is on 1-2. Upstream Slug Interrupt Action: Upstream Logic Modules will not slug release when Slug Release is initiated at the ZIM or downstream of the ZIM. Configuration: JP1 is on 1-2 and JP2 is on 2-3. Zone Status Indication Action: Zone status output on TB5 terminal 1 and TB3 is activated when the downstream logic module or remote sensor indicate an occupied zone. Configuration for Downstream Logic Module: JP4 is on 1-2 or 2-3 and JP5 is on 1-2 or removed. Configuration for Auxiliary Sensor or PLC Input: JP4 is removed and a high (ON) signal is applied to TB4 terminal 3. Zone Status Delay: The output transition of the Zone Status from (OFF) to (ON) or (ON) to (OFF) will only occur if the time delays set by the ZS ON and ZS OFF delay potentiometers have expired. A non-zero delay setting will filter out transitions that occur for less than the set time. This is typically used to indicate a zone is full only after a product is detected for a period of time indicative of a full and accumulated lane.
26
Page 29
ZIM-2
ZIM Board Layout - Full Function
Model Number
Part Number
Description
ZIM-2B1110
7029608
Full Function Module, for ZLM or WLR2100
ZIM-2B2110
7029704
Full Function Module, for WTR1
Warnings and Cautions NOTE: A qualified electrician must perform installation and servicing, in addition to checking with local code before installation, to ensure safe operation of the product. For technical assistance with this product, call SICK at 1-800-325-7425. • • • • • • • •
Be consistent with UL listing requirements for maximum protection. The input line cable and line fuses must be sized in accordance with the rated input current of the unit. Do not make any connections when connected to AC/DC utility supply line. Before applying power, make sure that all covers are closed. Verify there is no possible floating ground potential. Provide recommended interfacing wire type (i.e. 16-24 AWG multi-strand heat resistive copper wires). Any motor cables should cross other cables at an angle of 90 degrees. If conduit is being used for wiring, use separate conduits for the input power wiring, the output power wiring, the signal wiring and the control wiring. Serviceability/field repair: Devices are not serviceable.
Read manuals thoroughly and make sure you understand the procedures before you attempt to install, set up, or operate any SICK brand ZoneControl™ devices. The information contained in this manual is subject to change without notice.
C A U T I O N RISK OF ELECTRICAL SHOCK-MORE THAN ONE DISCONNECT SWITCH MAY BE REQUIRED TO DE-ENERGIZE THE EQUIPMENT BEFORE SERVICING
27
Page 30
ZoneControl™ Power Supply
C
SICK PS 50W-24V-ENC and PS 95W-24V-ENC power supplies feature a compact housing design that is designed specifically for use with SICK’s ZoneControl™ line of Logic Modules and conveyor sensors. These units meet the latest NEC Class II requirements in accordance with UL, EN, IEC standards. Installation is fast and easy due to slotted holes in a durable mounting plate that mounts directly to the side of the conveyor. SICK PS 50W-24V-ENC and PS 95W-24V-ENC power supplies are also capable of buffering brief power failure conditions at rated voltage (e.g. 20 ms at 120 V AC) in accordance with EN 60 624-1. Global acceptance is also achieved by conformance with cULus standards (North American compliance) and CE standard requirements (European compliance).
R
US
Features ■ Adjustable output voltage up to 24…28 V DC ■ 115/230 V AC input ■ State-of-the-art design ■ Perfect integration with ZoneControl™ system ■ IP 20 enclosure ■ Bolt on mounting
Dimensional Drawings
AC INPUT Ø 0.86 (22.1) 5.13 (130.4)
Ø 2.27 (57.8) 2x 1.18 (30.1) 0.13 (3.4)
78.8 in (2 m) 5.68 (144.2)
6.8 (173.7)
4.88 (124)
9.25 (235)
dimensions in inches (mm) Connection Diagram
* Required mounting orientation
28
1.4 (36.6) 3.4 (87.4)
1.09 (27.8)
Page 31
ZoneControl™ Power Supply
Technical Data
PS50W-24V-ENC
PS95W-24V-ENC
Input voltage range V AC (nominal)
100…240 V
100…120/220…240 V
Input voltage range V AC (continuous)
85…264 V
85…132/184…264 V
Input frequency
47…63 Hz
Input parameters
Input voltage range V DC (see derating requirements)
85…375 V
Power Consumption
< 11.5 W max
Inrush current
Transient immunity over entire load range
220…375 V
< 10 A (100 V AC)
< 2.0 A (100 V AC)
< 0.6 A (196 V AC)
< 0.95 A (196 V AC)
In acc. VDE 0160/W2 (750 V/1.3 ms)
Output parameters (at tee cable) Power
50 W
Output voltage
24…28 V DC adjustable (factory set to 24 V)3)
95 W
Output voltage preset
24.5 ± 0.5%
Ripple/noise at 20 MHz, 50 Ohm
< 50 m Vpp
Output voltage regulation accuracy
0.5% Vout static, ± 2.0% Vout dynamic
Output rated current
2.1 A (at 24 V DC), 1.8 A (at 28 V DC)
3.9 A (at 24 V DC), 3.2 A (at 28 V DC)
Hold up time during input
> 97 ms (196 V AC)
> 20 ms (196 V AC, 24.5 V/3.9 A)
supply interruption
> 17 ms (100 V AC)
> 20 ms (100 V AC, 24.5 V/3.9 A)
Operating temperature range (Tamb) - full load
14…122°F (-10…50°C)
14…122°F (-10…50°C)
Operating temperature range (Tamb) - derated
122…140°F (50…60°C)
Storage temperature
-13…185°F (-25…85°C)
0.5% Vout static, ± 1.5% Vout dynamic
General device parameters
Humidity
90% max., non-condensing
Input cable access one hole for 3/4” conduit, one hole for 1/2” conduit
AC connection wires1) Stranded cable
0.3…2.5 mm2/AWG 28-12
Solid cable
0.3…4 mm2/AWG 28-12
Stripping at wire end
0.24 in (6 mm)
Output connector cables
M12 4-pin tee cable, 2 m/AWG 22
Efficiency
88.5% (typ. at 230 V AC), 88% (typ. at 110 V AC); 2.1 A
Protection class
IP 20 (DIN/IEC 60 529)
IP 20 (DIN/IEC 60 529)
MTBF2)
600,000 hours
500,000 hours
Dimensions
9.25 x 5.67 x 5.13 in (235 x 144 x 130.4 mm)
9.25 x 5.67 x 5.13 in (235 x 144 x 130.4 mm)
Weight
4.1 lbs (1.9 kg)
3.9 lbs (1.8 kg)
Mounting
Only vertical mounting with 3 vent slots on top and AC entering bottom. Any other orientation may cause damage to device.
Clearance
Keep 2” clearance around vents
90% (typ. at 230 V AC), 89% (typ. at 110 V AC); 3.9 A
Applicable standards EN 60 950, IEC 60 950
Yes
EN 60 204-1, EN 50 178
Yes
Third party approvals UL 508 Listing (US and Canada)
Multiple listing
UL 60 950 Recognition (US and Canada) NEC Class II according to UL 1310
Multiple listing Multiple listing
1) NOTE: Secure wires from strain 2) MTBF at 24 V DC, 4 A; 230 V AC; Tamb 104°F (+40° C) 3) 24…28 VDC is set at power supply. Actual at tee cable is 27 V full load.
Order Information Model Number
Part Number
PS50W-24V-ENC PS95W-24V-ENC
7029741 7029740
Warnings and Cautions This is not a user or installation manual. See manual supplied with the power supply for full details, specifications, installation warnings and cautions!
29
Page 32
ZoneControl™ Accessories : Reflectors
Reflective area 80 x 80 mm Model Number Part Number 1003865 PL80A
Reflective area 32.8 x 8.4 mm Model Number Part Number 5308002 P45 0.1 (2.5)
3.3 (84)
0.3 (8.4)
0.2 (4) ø 0.1
2.7 2.8 3.3 (68) (71) (84)
0.2 (4.5)
0.2 (6.2)
0.5 (12.4)
0.3 (8.5)
ø 0.3 (7)
2.1 (3.5) (54)
1.8 1.3 (45) (32.8)
Reflector Ø 83 mm, center hole mounting Model Number Part Number 7020558 P975
ø 0.2 (4.8)
0.4 (9)
ø 3.3 (83)
0.3 (8)
Reflective area ø 23 mm, self-adhesive Model Number Part Number 7029889 PL1.25
Reflective area 47 x 47 mm Model Number P250
Part Number 5304812
1.9 (47)
0.2 (5)
1.9 (47)
2X ø0.14 (3.5)
0.2 (6)
0.4 (8.8)
0.4 0.8 0.4 (10) (20) (10)
1.9 (47.2)
0.8 2X ø0.15 (3.7) (21.2)
2.4 (61.6)
0.2 (4.4) 0.2 (5.6)
1.9 (49)
adhesive tape
2.0 (51)
Reflector hexagonal Model Number Part Number 7122603 PL2IMS02 front
0.21 (5.36)
Ø 1.24 (31.55)
1.3 (33) back
0.7 (17)
2.0 (51.6)
0.1 (3.5)
0.2 (4.2)
Reflector area 15 x 38 mm Model Number Part Number 1012719 PL20A 0.2 (4.2)
0.6 (15) ø 0.2 (4.6)
2.4 (60)
2.0 1.5 (50) (38)
Reflective area 28 x 56 mm Model Number Part Number 1002314 PL30A
0.7 (18)
0.1 (3.4)
1.1 (27.8) ø 0.3 (8)
0.3 (7.3)
3.2 2.8 (82) (71)
Reflective area 38 x 56 mm Model Number Part Number 1012720 PL40A ø 0.2 (4)
ø 0.2 ø 0.3 (4.5) (8)
0.4 (9)
1.3 (34)
2.2 2.4 (56.6) (60.9)
2.0 (52)
2.2 (56)
0.3 (7.8) 0.3 (7.2)
1.2 (29.8) dimensions in inches (mm)
30
1.5 (38)
1.6 (40.2)
Page 33
ZoneControl™ Accessories : Cables
Tee cable type 1, M12 DC 4-pin, 300 mm
M12x1
JD4-TM12300A
6011682
Tee cable type 1, M12 DC 4-pin, 300 mm
JD4-TM12300B JD4-TM122000A
6011683 7122472
Tee cable type 2, M12 DC 4-pin, 300 mm Tee cable type 1, M12 DC 4-pin, 2 m
JD4-TM122000C KD4-SIM122
7029863 7020020
Tee cable type 1, M12 DC 4-pin, to flying leads, 2 m 2 m straight M12 DC 4-pin cable
KD4-SIM125
7020678
5 m straight M12 DC 4-pin cable
KD4-SIM1210
7020080
10 m straight M12 DC 4-pin cable
KD4-RIM122
7020023
2 m right angle M12 DC 4-pin cable
KD4-RIM125
7020679
5 m right angle M12 DC 4-pin cable
KD4-RIM1210
7021244
10 m right angle M12 DC 4-pin cable
ZPI-P1
7027723
Power isolator
ZSI-P4 ZL1-P2
7027187 7029124
Slug interrupt
ZGC-1 ZGC-2
7027804 7028421
Gender changer - male/male Gender changer - female/female
ZLCO-MD
7028474
Logic crossover - pin 2 male, pin 4 female
ZLCO-FD
7029473
Logic crossover - pin 2 female, pin 4 male
KA14-SEM121
7027083
1 m straight M12 reverse-key AC 4-pin cable
KA14-SEM122 KD4-SEM120.25SM12 KD4-SIM122SM12
7027086 7028981 7023135
2 m straight M12 reverse-key AC 4-pin cable Extension cable, M12 DC 4-pin, 0.25 m Extension cable, M12 DC 4-pin, 2 m
1/4” plug
-
7028425
3/8” plug
2
2
4
3 1
Tee cable type 2, M12 DC 4-pin, 300 mm
M12x1
M12x1
1 orange black
11.81 (300)
1 3 orange
4 2 brown
1 blue
3 black
4 white
2
2
4 3 1
2 m, 5 m, 10 m straight M12 DC 4-pin cable
6.5, 16.4 or 32.8 ft (2, 5 or 10 m) 0.4 (11)
grey
M12 Male 2
1
3
4
0.55 (14)
grey black
M12x1
1.7 (43)
4 white
2
4
3 1
1.3 (32)
brown
1 blue
3 black
4 white
M12 Male
0.8 (19)
2
1
3
4 grey M12x1 0.6 (14)
blue black blue brown
2 white
2
6.5, 16.4 or 32.8 ft (2, 5 or 10 m)
1.0 (25.5) 1.0 (25)
4 blue
2 m, 5 m, 10 m right angle M12 DC 4-pin cable
1
3 grey
2
Tee cable type 1, M12 DC 4-pin to flying leads, 2 m
1
0.1 (3)
brown
2
3 blue
4
1.0 (25.5)
1 blue black
3 brown white
1 grey
M12x1
4 white
M12x1
M12x1
M12x1
3 black
M12x1
Tee cable type 1, M12 DC 4-pin, 2 m
M12x1
2
1 blue brown
Kit, 1/4” plug and clip
7028457
78.7 (2000)
4 brown blue
7028451
-
3 black
-
2.1 (54)
1 orange white
Extension cable, M12 DC 4-pin, 3 m
78.7 (2000)
black
11.81 (300)
1.67 (42.5)
7028657
2.1 (54)
orange
Logic interrupt cable
KD4-SIM123SM12
1 brown
Description blue
Part Number black
Model Number white
Power and Interconnect Cables
M12x1
1.67 (42.5)
2
4
3 1 dimensions in inches (mm)
31
Page 34
ZoneControl™ Accessories : Cables
Power isolator
7.9 (200)
1.6 (40)
0.9 (24)
1.7 (43)
M12 Female
M12 Male 1.1 (27)
1
2
4
4
3
2
1
1
2
3
4
4
3
1
2
0.2 (5.2)
0.5 (14) M12x1
M12x1 0.5 (14) 3 blue
1 2 3 4
N/C
1 2 3 4 blue blue
Slug interrupt
7.9 (200)
1.6 (40)
0.9 (24)
1.7 (43)
M12 Female
M12 Male 1.1 (27)
0.2 (5.2)
0.5 (14) M12x1
M12x1 0.5 (14)
blue
1 2 3 4
N/C
1 2 3 4 blue grey
Gender changer - male/male
7.9 (200)
1.6 (40)
1.6 (40)
M12 Male 2
1
3
4
0.2 (5.2) 0.5 (14) M12x1
M12x1 blue grey
0.5 (14)
1 2 3 4
1 2 3 4
1 2 3 4
1 2 3 4 blue
Gender changer - female/female
1.1 (27)
7.9 (200)
1.7 (43)
1.7 (43)
M12 Female 1.1 (27)
1
2
4
3
0.2 (5.2) 0.5 (14)
M12x1 0.5 (14)
M12x1 blue grey blue
Logic interrupt
0.9 (24)
7.9 (200)
1.6 (40)
1.7 (43)
M12 Female
M12 Male 1.1 (27)
2
1
1
2
0.2 (5.2)
0.5 (14) M12x1
M12x1 0.5 (14) 3 blue black blue
32
4
4
3
1 2 3 4
N/C
1 2 3 4
Page 35
ZoneControl™ Accessories : Cables
Extension cable
0.9 (24)
9.8 (250)
1.6 (40)
1.7 (43)
M12 Female
M12 Male 1.1 (27)
2
1
1
2
3
4
4
3
1 2 3 4
0.2 (5.2)
0.5 (14) M12x1
M12x1 0.5 (14)
blue
1 2 3 4 blue grey
1 m, 2 m, straight M12 reverse-key AC 4-pin cable
3.3 or 6.6 ft (1 or 2 m)
Reverse-key M12 Female
0.3 (7.0)
1
2
3
4
0.2 (4.4) 0.5 (14) M12X1 0.4 (11.5) 1.6 (42)
blue
2.0 (50)
blue black dimensions in inches (mm)
Mounting Brackets Mounting bracket, W.2000, stainless steel Model Number Part Number 7022981 MB-W2000 2.8 (71.1)
1.1 (27.9) 0.8 (20.3)
0.6 (15)
1.3 (31.8) 2.7
45°
0.3 (7.1)
1.1 (28.6)
0.5 (12.7)
1.2 (30.5) Dia. 2.0 (50.8) Dia.
1.2 (30.5) Dia.
48.3 60.2 (1.90) 2 PL (2.37)
2.0 (50.8)
0.3 (71)
1.2 (31.6)
0.7 (16.7) 2.3 (58.8)
1.1 (27.2)
2.7 2.0 (52) (67.7)
ø11.3 0.7 (18.3)
0.2 (4.8) 0.4 (10)
2.6 (66)
0.4 (9.5) M10
90°
Mounting bracket kit, WTR Model Number Part Number 7029344 MB-WTR-1 KIT
0.1 (3.0) Ref
Mounting Bracket for 18 mm threaded sensors Model Number Part Number MB-BS18MM
4.9 (125) 2.5 (62.5) 1.7 (43)
2.0 (50.8)
19.0 (0.75) 2 PL 1.3 (31.8)
6.1 (155)
1.2 (29.2)
(67.3)
90°
Mounting bracket, WTR Model Number Part Number 2017417 BEF-WN-WTR
Mounting bracket, W.2000, stainless steel Model Number Part Number 7022976 MB-W2000B
0.07 (1.8)
M18 x 1 mm interna
7 028 403
0.91 (23.1)
1.9 (48.6) REF
0.20 (5.1)
1.6 (40.0) REF
0.67 (17.0)
3.62 (91.9)
RO. 25 (0.21)
0.44 (11.2)
1.42 (36.0) 2x
Ø 0.18 (25.4) 0.67 (17)
Recommended thru hole: Ø 0.194 (4.9)
0.39 (9.9)
1.22 (31.0) 2x 0.61 (15.48)
Recommended thru hole: Ø 0.152 (3.9)
0.47 (11.9)
2.44 (61.9)
1.5 (37.7)
0.66 (16.8)
0.21 (5.3)
0.28 (7.1) 0.63 (16.0) 2x 2.72 (69.0)
R. 0.09 (2.3) 2x
1.02 (25.9)
dimensions in inches (mm)
0.6 (16.0)
33
Page 36
Safety Systems
Automatic Identification
SICK is one of the world’s leading manufacturers of sensors, safety systems, and automatic identification products for industrial applications. SICK holds more than 450 patents for its innovative products. Through its Industrial Sensors, Safety Systems, Automatic Identification, and Environmental and Process Analysis divisions, the company has operations in 65 countries. SICK North America is headquartered in Minneapolis, MN. Our wide range of sensors provides solutions to suit any application in the field of automation. Even under rugged ambient conditions, objects are reliably detected, counted and positioned regardless of their form, location and surface finish.
Australia Phone +61 3 94 97 41 00 Toll free0 08 33 48 02 E-mail sales@sick.com.au Austria Phone +43 22 36 62 28 80 E-mail office@sick.at Belgium/Luxembourg Phone +32 24 66 55 66 E-mail info@sick.be Brazil Phone +55 11 5091 4900 E-mail sac@sick.com.br China Phone +852 27 63 69 66 E-mail ghk@sick.com.hk Czech Republic Phone +42 02 57 91 1850 E-mail sick@sick.cz Denmark Phone +45 45 82 64 00 E-mail sick@sick.dk Finland Phone +358 925 15 800 E-mail sick@sick.fi France Phone +33 1 64 62 35 00 E-mail info@sick.fr
Products from SICK provide comprehensive safeguarding of both workers and machinery. As experts in sensor technology, SICK develops and manufactures pioneering products that provide protection in hazardous zones, dangerous locations and for safeguarding access points. By providing services, which encompass all aspects of machine safety and security, SICK is setting new standards in safety technology. Whether the tasks involve identification, handling, classification or volume measurement, innovative automatic identification systems and laser measurement systems from SICK function reliably, even under rapid cycle times. Products from SICK conform to the latest standards and can be easily integrated in all industrial environments and external applications.
Germany Phone +49 21 15 30 10 E-mail info@sick.de
Singapore Phone +65 67 44 37 32 E-mail admin@sicksgp.com.sg
Great Britain Phone +44 17 27 83 11 21 E-mail info@sick.co.uk
Slovenia Phone +386 (0) 1-47 69 990 E-mail selanm@sick.com
Italy Phone +39 02 92 14 20 62 E-mail info@sick.it
Spain Phone +34 9 34 80 31 00 E-mail info@sick.es
Japan Phone +81 3 33 58 13 41 E-mail info@sick.jp
Sweden Phone +46 86 80 64 50 E-mail info@sick.se
Korea Phone +82 27 86 63 21-4 E-mail kang@sickkorea.net
Switzerland Phone +41 4 16 19 29 39 E-mail contact@sick.ch
Netherlands Phone +31 3 02 29 25 44 E-mail info@sick.nl
Ta iwa n Phone +886 2 23 65 62 92 E-mail sickgrc@ms6.himet.net
Norway Phone +47 67 81 50 00 E-mail austefjord@sick.no
Turkey Phone +90 216 388 95 90 pbx E-mail info@sick.com.tr
Poland Phone +48 2 28 37 40 50 E-mail info@sick.pl
USA/Canada/Mexico Phone +1 (952) 9 41 67 80 E-mail info@sickusa.com
Russia Phone +7 95 775 05 30 E-mail info@sick-automation.ru
Branch offices and representatives in all major industrial countries.
7027984.0604 . Printed in USA . Subject to change without notice
Industrial Sensors