Page 61

11 Care and Maintenance 11.1 SICK-Service / Hotline The PLS is extensively maintenance-free. Note: Do not open the sensor. It does not contain any parts you can repair. In the event of damage occurring to the PLS, contact SICK Service.

Cleaning the front screen To enable the sensor to function fault-free, you should clean the front screen as soon as slow rhythmic flashing (once per second) of the yellow LED accompanied by a steadily lit green LED signals light contamination. The PLS will still keep working in this state. Only as the degree of dirt contamination increases will the yellow LED come on steadily, the PLS switches off and the red LED lights up (see “LEDs on the PLS”). Clean the front screen only with a soft cloth and plastic cleaner. Never use rough rags or aggressive cleaning agents such as acetone etc.! Otherwise the front screen may be damaged. If the front screen is scratched or damaged and needs to be replaced, you can order a replacement from SICK (see Appendix under “Accessories”) and replace it yourself.

If a fault occurs (e.g. the yellow LED is flashing rapidly, at around 4 times per second), be sure that your first step is always to carry out the fault diagnosis in the PLS user software. You can find more details on this in Chapter 9 under “Interrogate fault memory – System diagnosis”. This SICK diagnosis function will provide you with detailed information about the fault which has occurred. You can find out about what the fault code means from the fault table in Section 11.3, and ascertain whether you can rectify the fault yourself. If you are unable to rectify the fault yourself, please contact your nearest supplier. Print out the fault report produced by the SICK Diagnosis function and have it to hand when you contact SICK Service. If you need to send in the PLS, please also enclose the fault report together with the completed Service questionnaire. You will find a master copy of the Service questionnaire in Section 11.4. If you are having difficulties or are unsure about how to use your PLS, please contact our hotline. You can reach it under Tel. (++49) 7681 / 202-3134 or Fax (++49) 7681 / 202-3130.. SICK also offers an Installation and Commissioning service package. Our Service department will be able to help you if you need further assistance.

Replacing the front screen Notes: The front screen must only be replaced by trained personnel in a clean environment. The front screen of the PLS is an optical component which must not be contaminated with dirt or scratched during replacement. Do not use silicon to seal the front screen, as the ensuing fumes could endanger the optical function. Mount the front screen correctly to ensure that the housing sealing complies with protection rating IP 65. Before removing the front screen disconnect the power connector to cut power to the unit! Please carefully follow the assembly instructions for the PLS “Changing the front screen”. The contamination calibration must be carried out every time the front screen is replaced! From the menu select PLS – Extras – Calibration of contamination measurement. Note: The contamination calibration may only be carried out immediately after replacing the front screen. The new front screen must not be contaminated with dirt when the calibration is performed.

8 008 316/O801/07-07-04 Technical Description • PLS © SICK AG • Industrial Safety Systems • Germany • All rights reserved

PLS_TB_GB_06_05_02_M844.pmd

61

08.07.2004, 15:55

61

Page 62

11.2 LEDs on the PLS The PLS has three light-emitting diodes (LEDs), which deliver important information.

green

In this regard also refer to the description of the PLS/LSI user software as from Chapter 9, which gives detailed information about programming the fields and outputs.

yellow red

Red and green LEDs: The red and green LEDs indicate the status of the protective field and the protective outputs (OSSDs). PLS LEDs:

Yellow LED:

Status green

The yellow LED indicates whether the warning field has been infringed or the front screen of the sensor is contaminated with dirt. You can set which option you want in the PLS/LSI user software. The description of the user software, Section 9.3, gives detailed information on setting the “Weak Signal” output.

Protective field clear

Also, in conjunction with the red LED, this yellow LED indicates whether the sensor is awaiting release (restart).

Contamination * yellow red

Object in protective field Object in warning field Wait for restart

1 Hz

Contamination warning *

1 Hz

4 Hz

Self-test negative ** = LED on = LED flashes slowly = LED flashes quickly

1 Hz 4 Hz

Output level: Status

OSSD Output

Warning field output (Weak) Error

Protective field clear Warning field clear

1)

Object in protective field Object in warning field

1)

Wait for restart

2)

Contamination warning *

1)

Contamination * Self-test negative **

4 Hz

Start test

1) dependent on programming 2) priority over warning field / Weak message * Clean front screen with plastic cleaner and a soft cloth. ** Perform system diagnosis. (see Section 9.11)

62

8 008 316/O801/07-07-04 Technical Description • PLS © SICK AG • Industrial Safety Systems • Germany • All rights reserved

PLS_TB_GB_06_05_02_M844.pmd

62

08.07.2004, 15:55

Page 63

11.3 PLS Fault table For safety reasons your PLS continuously performs self-test routines to guarantee fault-free functioning of the unit in case of danger. If one of these tests fails when the system is starting up or during operation, the PLS automatically shuts down the dangerous machine or plant as a safety precaution.

This table enables you to find out whether the SICK diagnosis fault codes mean, and whether you can rectify the fault yourself. How to execute the SICK diagnosis is described in Section 9.11. Note: If you get a fault code which you cannot find in the table, please contact SICK Service.

Error code:

Cause / What you can do about it:

2–16

Internal error: Cut the power to the PLS for at least 3 seconds. If the problem persists, contact the SICK Hotline.

17–20

Dirt contamination of the front screen: Clean the front screen or replace it. The contamination calibration must be performed every time the front screen is replaced!

24

Mutual interference between several PLS units: Eliminate the interference by changing the PLS mounting configuration. Follow the mounting instructions in Chapter 7. Motor speed incorrect: Operating at low temperatures. Observe the specifications of the unit (see Technical data).

27

External circuitry of OSSD 1 faulty: Check the wiring of the external circuitry. Test for short-circuit in the shutdown path to 0 volts, to 24 volts and to the second shutdown path. Make sure the resistive and capacitive load on the shutdown path complies with the unit specifications. Also test the connectors and the crimping of the cabling. Undervoltage in power supply to unit: Make sure the power supply to the unit complies with the specification (see Technical data). Measure the voltage directly on the PLS to take account of any voltage drop resulting from long supply lines.

28

External circuitry of OSSD 2 faulty: See error code 27 Undervoltage in power supply to unit: See error code 27

29

Motor speed incorrect: Operating at low temperatures. Observe the specifications of the unit (see Technical data).

31

Sensor dazzled while measuring: Check whether the PLS is being dazzled by an external light source, e.g. headlights, infrared light sources, sun etc. Slightly altering the location of the PLS may be sufficient to solve the problem (to do this observe the mounting instructions described in Chapter 5). If you are using the PLS on a driverless transport system, check whether the application variant “Vehicle protection” has been selected.

8 008 316/O801/07-07-04 Technical Description • PLS © SICK AG • Industrial Safety Systems • Germany • All rights reserved

PLS_TB_GB_06_05_02_M844.pmd

63

08.07.2004, 15:55

63

Page 64

64

Error code:

Cause / What you can do about it:

32

Object detected in the protective field: Check the ambient conditions. Adjust the PLS configuration to the ambient conditions.

33

Object detected in the protective field: Check the ambient conditions. Adjust the PLS configuration to the ambient conditions.

41

Shutdown paths are not interacting correctly: See error codes 27 and 28, for undervoltage in the unit power supply see error code 27.

42

Sensor receiving no data over 90° of its measuring range: To ensure fault-free functioning of the sensor, make sure it is always receiving readings within a range of 90°, and is freely adjustable within the scanning area. In area protection this is normally always the case, so the PLS signals the fault after three seconds. In vehicle protection a condition of this kind may occur briefly while the vehicle is moving across the hall, so the unit only signals this fault after two hours.

8 008 316/O801/07-07-04 Technical Description • PLS © SICK AG • Industrial Safety Systems • Germany • All rights reserved

PLS_TB_GB_06_05_02_M844.pmd

64

08.07.2004, 15:55

Page 65

11.4 Service questionnaire On the following page you will find our Service questionnaire. This is designed to record all relevant data relating to any PLS laser scanner sent in to us. Based on the information you give, we are able to take all necessary measures straight away to ensure your scanner is returned to you as soon as possible. Please return the completed questionnaire with the scanner.

8 008 316/O801/07-07-04 Technical Description • PLS © SICK AG • Industrial Safety Systems • Germany • All rights reserved

PLS_TB_GB_06_05_02_M844.pmd

65

08.07.2004, 15:55

65

Page 66

Sick AG, Seb.-Kneipp-Straße 1, D-79183 Waldkirch, Tel.: (++49) 7681 / 202 - 3134, Fax: - 3130

PLS - Service Questionnaire By completing the questionnaire below you will help us by carrying out fault diagnosis. As soon as we have the following details, we will get back to you as quickly as possible. This makes efficient handling of queries possible.

Company

_______________________________________________________________

Contact

_________________________ Sick contact _________________________

Adress

_______________________________________________________________

Phone

_________________________ Fax: _________________________________

Hardware as per rating plate:

PLS model: Order number: Device number:

PLS _ _ _ - _ _ _ 1 0__ ___ ____ ____

Software:

PLS user software version: 0_ . _ _ – Select “About User Software” from the “Help” menu.

Sensor status:

Please enclose printout: – Log on to the user software as an “Authorised Client”. – Select “SICK diagnosis” from the “Sensor” menu. – Select, add, run and save the telegrams “Read sensor status” and “Read fault memory”.

Application:

Area protection ❏

Problem:

_______________________________________________________________

Mobile application ❏

_______________________________________________________________ _______________________________________________________________

If the yellow LED is flashing rapidly (4 times per second): – Is the voltage to the PLS power connector in the permissible range? no ❏ yes ❏

Please enter the mean voltage: ______V

If the red LED is flashing rapidly (approx. 2 times per second): – Does the 24 V power pack of the PLS have a load capacity of at least 1.5 A? no ❏ yes ❏

If the red LED is active: – Where is the protective field being infringed?

Interior ❏

Edges ❏

– Please describe the application and any critical ambient conditions: _______________________________________________________________________________ _______________________________________________________________________________ _______________________________ Sketch of application on back: yes ❏

66 no ❏

8 008 316/O801/07-07-04 Technical Description • PLS © SICK AG • Industrial Safety Systems • Germany • All rights reserved

PLS_TB_GB_06_05_02_M844.pmd

66

08.07.2004, 15:55

Page 67

12 Appendix 12.1 Characteristics

Characteristics: Correlation between reflectance of object, range and resolvable object diameter. The given remission relates to a worst-case contaminated front screen.

8 008 316/O801/07-07-04 Technical Description • PLS © SICK AG • Industrial Safety Systems • Germany • All rights reserved

PLS_TB_GB_06_05_02_M844.pmd

67

08.07.2004, 15:55

67

Page 68

12.2 Accessories

Interface cables

Note: If you want to deploy one or more PLS together with an LSI (Laser Scanner Interface), you will find the necessary accessories listed in the appendix to the technical description of the LSI.

For RS 232 Order No. Interface cable 3 m

2 016 401

Interface cable 5 m

2 016 402

Order No.

Interface cable 10 m

2 016 403

1 016 066

For RS 422

Certified to IEC/EN 61496: PLS 101-312

Order No.

Mounting kits

Interface cable 3 m

2 019 130

Interface cable 5 m

2 019 131

Interface cable 10 m

2 019 132

Order No. Mounting kit 1, inc. screws for PLS

2 015 623

Mounting kit 2, inc. screws for mounting kit 1

2 015 624

Mounting kit 3, inc. screws for mounting kits 1 and 2

2 015 625

Documentation and PLS/LSI user software WIN 3.11TM on request for WIN95TM /WIN98TM /WIN NTTM Technical description, German, with user software

2 021 899

Connection set

Technical description, English, with user software

2 021 900

Instead of connection set 1, which is supplied as standard, you can order one of the connection sets 2 to 7, which include a cable fitted to the power connector (cable outlet upward). Various cable lengths are available:

Technical description, French, with user software

2 021 901

Technical description, Spanish, with user software

2 021 902

Order No. Connection set 1, power and interface connectors without cable

2 016 184

Connection set 2, with 3 m cable

2 016 185

Connection set 3, with 5 m cable

2 016 186

Connection set 4, with 10 m cable

2 016 187

Connection set 5, with 15 m cable

2 016 188

Connection set 6, with 20 m cable Connection set 7, with 30 m cable

Other SICK accessories Order No. Power pack 24 V, 2.5 A

6 010 361

Power pack 24 V, 4 A

6 010 362

Interface module LCU-X

1 013 410

Switch device PNOZ 8 24V

6 010 810

2 016 189

Replacement front screen (with seal and screws)

2 022 271

2 016 190

Anti-static plastic cleaning agent, 1 litre

5 600 006

And also ... You can obtain the following accessories as required from computer equipment suppliers: – Interface adapter 9-pin (plug) to 25-pin (socket): If you want to connect a PC which only has a 25-pin serial port connector. – Crimping tool: If you want to self-assemble your power and interface connectors. Available, for example, from: Harting KG 32325 Espelkamp Phone +49 (0)5772/47-0; Fax +49 (0)5772/47-461 “Hand-held crimping tool for single contacts” Order no. 0999 000 0175

68

8 008 316/O801/07-07-04 Technical Description • PLS © SICK AG • Industrial Safety Systems • Germany • All rights reserved

PLS_TB_GB_06_05_02_M844.pmd

68

08.07.2004, 15:55

Page 69

12.3 Technical data Here you can find the key technical data of the PLS. Note: If you want to deploy one or more PLS together with an LSI (Laser Scanner Interface), please also refer to the technical data of the LSI (see the technical description of the LSI). Electrical details Viewpoint for the nominal values is the plug corner (unless stated otherwise).

Properties Supply voltage (Uv)

min.

Type details max.

16.8 V

24.0 V

28.8 V

Non-transposable, via safety isolating transformer as per EN 60742 (also charger on transport vehicles)

500 mV

The limit values of the supply voltage may not be exceeded or fallen below.

Permitted residual ripple (VRMS)

Comments

Response time (adjustable via multiple evaluation) two-fold

2 x 40 ms sixteen-fold

16 x 40 ms

Start times With power ON

6s

Consumption (without load)

17 W

RESET / RESTART input

Necessary: command unit for operating mode with restart inhibit: make contact against VCC_EXT (Uv), dynamically monitored

Input resistance at HIGH

5.9 kOhm

Voltage for HIGH

15 V

Uvmax

Voltage for LOW

0V

4.2 V

Power consumption (HIGH) Initial impulse current (with τ = 100 µs) 3.0 mA

6.6 mA

Static input current

5.2 mA

2.2 mA

Power consumption (LOW) Initial impulse current (with τ = 100 µs)

0.9 mA

Static input current

0.5 mA

Temporal key behaviour (safe restart detection) LOW level before restart

120 ms

HIGH level during restart

120 ms

LOW level after restart

> 1 ms

5s

8 008 316/O801/07-07-04 Technical Description • PLS © SICK AG • Industrial Safety Systems • Germany • All rights reserved

PLS_TB_GB_06_05_02_M844.pmd

69

08.07.2004, 15:55

69

Page 70

Properties min.

Type details

Comments max.

Warning field output (PNP) Voltage: warning field clear Voltage: warning field clear

Uv - 2.5 V 13.4 V when Uv = 16.8 V

Switching current (apply relation to EXT_GND) Temporal output behaviour without restart inhibit

100 mA Deactivation is dependent on the multiple evaluation, but activation is not

Deactivation after WF infringement (2-fold evaluation)

127 ms

Activation when warning field (WF) clear

40 ms

Temporal output behaviour with restart inhibit

Dependent on the multiple evaluation

Deactivation after WF infringement (2-fold evaluation)

127 ms

Activation when warning field (WF) clear Restart necessary Temporal output behaviour after n seconds

Dependent on the multiple evaluation

Deactivation after WF infringement (2-fold evaluation)

127 ms

Activation when warning field (WF) clear

40 ms

Short-circuit-protected yes

Operating sequence

3 Hz

Load inductance

2H

Protective outputs (OSSDs) - dynamic (HIGH active) Switching voltage HIGH active (Ueff)

Uv - 2.5 V

Switching voltage HIGH active (Ueff)

13.4 V

Voltage LOW

0V when Uv = 16.8 V 2.5 V

Switching current (applied to EXT_GND) 4 mA Temporal output behaviour without restart inhibit Activation when protective field clear Temporal output behaviour with restart inhibit Activation when protective field clear Temporal output behaviour after n seconds Activation when protective field clear

70

250 mA

Dependent on the multiple evaluation 190 ms Dependent on the multiple evaluation 580 ms Dependent on the multiple evaluation 3s

8 008 316/O801/07-07-04 Technical Description • PLS © SICK AG • Industrial Safety Systems • Germany • All rights reserved

PLS_TB_GB_06_05_02_M844.pmd

70

08.07.2004, 15:55