Page 41

This dialog window appears. This is where you set when the “Weak Signal” output is to activate.

•

•

Select the desired condition: – Contamination of front screen or object in warning field – Object in warning field – Contamination of front screen Click on “Continue”.

If you create a new configuration this dialog window appears. This is where you define the monitoring area.

•

Select the shape of the protective and warning fields. You can define the sizes of the fields now or later. If you want to define them now, click on “Dimensions” and enter the dimensions you want.

Note: You can find more details on editing the protective and warning fields in Section 9.4.

•

Click on “Continue”.

•

Click on “OK” to accept the configuration.

The configuration is defined. You can now transmit the settings to the PLS, as described in the following section.

8 008 316/O801/07-07-04 Technical Description • PLS © SICK AG • Industrial Safety Systems • Germany • All rights reserved

PLS_TB_GB_06_05_02_M844.pmd

41

08.07.2004, 15:54

41

Page 42

Send configuration to PLS

• •

Make sure you are logged an as an “Authorised Client” (see status bar at bottom of screen). If you are not logged an as an “Authorised Client” select PLS – User Category from the menu, or click on the “Logon/-Logoff User Category” button on the toolbar.

This dialog window appears.

• •

Select “Authorised Client” from the list of user categories. Enter the pasword “SICK_PLS” and click cn “Logon”.

You are now logged on and can send data to the PLS.

•

From the menu select PLS – Configuration – Send to PLS, or click on the “Send Configuration” button on the toolbar.

The screen displays an overview of the configuration settings for you to check through once again. Reject settings:

• •

Click on “Cancel” to close the overview. From the option PLS – Configuration – Edit in the menu you can now enter the correct settings.

Confirm settings:

•

Click on “Confirm”.

The configuration data is sent to the PLS and stored there.

This dialog window appears.

• •

42

If you want to transmit the monitoring ranges unchanged, click on “Yes”. You can then skip the next section, “Edit monitoring range”. If you also want to alter the shape and size of the monitoring ranges, click on “No”. You can then edit the protective and warning fields, as described in the following sections.

8 008 316/O801/07-07-04 Technical Description • PLS © SICK AG • Industrial Safety Systems • Germany • All rights reserved

PLS_TB_GB_06_05_02_M844.pmd

42

08.07.2004, 15:54

Page 43

Edit monitoring range The screen displays the protective field you have defined. You can edit the size of the protective and warning fields after defining them.

• • •

From the menu select Monitoring Range – Edit, or click on the “Edit Monitoring Range” button on the toolbar. From the “Active field” list select the protective or warning field you want to edit. From the “Active Background Field” list select the protective or warning field that you want to see in the background for comparison purposes.

The selected fields and the contour of the sensor are shown onscreen. A colour code for displaying the protective and warning fields is shown in the status bar at the bottom of the screen.

Convert field shape:

•

To convert a field into a different shape, select Edit – Convert Into from the menu.

Three different field shapes are available to choose from: – Rectangle: This is the default. Newly defined fields are always this shape, unless you select a different setting. You can adjust the height of the rectangle and the width at the right and left. – Semicircle: Here you can define the radius. – Segmented field: You can select various resolutions. The more segments a field has, the higher is its resolution. You can define the co-ordinates for each segment individually. Notes: Warning fields are always segmented fields. If you have defined a warning field as a rectangle or semicircle, it is automatically converted into a segment with the appropriate dimensions. When you convert a field or change the resolution of a segmented field, the shape of the field may change minimally, but this is displayed on-screen.

The following sections set out only the basic means of defining the sizes of the various field shapes. For more information on editing fields, refer to Section 9.4.

8 008 316/O801/07-07-04 Technical Description • PLS © SICK AG • Industrial Safety Systems • Germany • All rights reserved

PLS_TB_GB_06_05_02_M844.pmd

43

08.07.2004, 15:54

43

Page 44

Define rectangular field:

•

To set or move a comer point: Double-click on the desired position with the mouse.

Note: In the example a rectangular grid pattern was selected for the screen view. You can switch between circular and rectangular grid patterns. For more details refer to Section 9.14.

… or:

•

From the menu select Edit – Field Co-ordinates.

This dialog window appears, showing the dimensions of the rectangle.

• •

Enter the dimensions you want. Confirm with “OK”.

The dimensions of the rectangle are changed accordingly.

Define semicircle:

•

Double-click with the mouse on the desired position to define the radius of the field.

… or:

•

From the menu select Edit – Field Co-ordinates.

This dialog window appears, showing the radius of the semicircle.

• •

Enter the dimensions you want. Confirm with “OK”.

The radius of the semicircle is changed accordingly.

44

8 008 316/O801/07-07-04 Technical Description • PLS © SICK AG • Industrial Safety Systems • Germany • All rights reserved

PLS_TB_GB_06_05_02_M844.pmd

44

08.07.2004, 15:54

Page 45

Define segmented field:

• • •

To set a point with the mouse: Double-click on the desired position. To move a point with the mouse: Select the point and drag it to the desired position. To delete a point: Mark the point and click on the “Delete” button on the toolbar.

… or:

•

From the menu select Edit – Field Co-ordinates.

This dialog window appears, showing the co-ordinates of all defined points. You can add any points to the list, or you can select a point and edit or remove it.

• • •

To set a point: Click on the “Add” button and enter your desired coordinates in the dialog window. To move a point: Select the point in the list and click on the “Edit” button. Enter your desired co-ordinates in the dialog window. To delete a point: Select the point in the list and click on the “Delete” button.

Note: You can also select a point with the mouse before selecting Edit – Field Co-ordinates. The co-ordinates of the point in question are then already highlighted in the list.

•

When you have defined the protective and warning fields as you want, deactivate the Monitoring Range – Edit function or deactivate the “Edit Monitoring Range” button on the toolbar.

Note: After programming, check on the plant or vehicle that the monitoring range is the correct size and shape! You can do this by intruding intentionally into the monitoring range. This also applies when you upload a field from a floppy disk into the PLS. Only start up the plant or vehicle when you are sure the monitoring range is operating effectively!

8 008 316/O801/07-07-04 Technical Description • PLS © SICK AG • Industrial Safety Systems • Germany • All rights reserved

PLS_TB_GB_06_05_02_M844.pmd

45

08.07.2004, 15:54

45

Page 46

Send monitoring range to PLS

•

From the menu select Monitoring Range – Send to PLS, or click on the “Send Monitoring Range” button on the toolbar.

This dialog window appears.

•

Click on “Add All”. Or – if you only want to transmit individual fields – select the fields you want from the list at the top and click on “All”.

The fields are entered in the list at the bottom.

•

Click on “Send” and confirm for each individual field with “Yes” or “OK” as appropriate.

This dialog window appears. The transmitted fields are now marked with asterisks in the list.

• •

Check that protective and warning fields are marked with an asterisk, and so have been transmitted correctly. If you already sent the configuration before, you can click on “No”. If you have not already sent the configuration, click on “Yes” and transmit as previously described under “Send configuration to PLS”.

When you have transmitted the configuration and the monitoring range, the system is ready for operation.

Note: When leaving your workstation log off by way of the PLS – User category menu function! Also change the “Authorised Client” logon password. Make a note of the new password at a location accessible only to authorised persons. This will prevent unauthorised persons from manipulating the PLS system (how to change the password is described in Section 9.9).

46

8 008 316/O801/07-07-04 Technical Description • PLS © SICK AG • Industrial Safety Systems • Germany • All rights reserved

PLS_TB_GB_06_05_02_M844.pmd

46

08.07.2004, 15:55

Page 47

9.4 Edit/dimension fields Section 9.3 describes the basic way to edit a protective or warning field. You can use rectangular, semicircular or multiplysegmented fields. You can draw the fields either by using the mouse or by typing in their co-ordinates. This chapter describes the additional options of defining the size and shape of the protective and warning fields for your application. Various edit functions will assist you in drawing up the fields. A colour code for displaying the protective and warning fields is shown in the status bar at the bottom of the screen. Note: After programming, check on the plant or vehicle that the monitoring range is the correct size and shape! You can do this by intruding intentionally into the monitoring range. Only start up the plant or vehicle when you are sure the monitoring range is operating effectively!

Convert field shape: You can convert a field into a different shape – for example, a rectangular field into a segmented field.

•

Select Edit – Convert Into from the menu.

Three different field shapes are available to choose from – Rectangle: This is the default. Newly defined fields are always this shape, unless you select a different setting. You can adjust the height of the rectangle and the width at the right and left. – Semicircle: Here you can define the radius. – Segmented field: You can select various resolutions. The more segments a field has, the higher is its resolution. You can define the co-ordinates for each segment individually. Note: Please observe that during conversion slight deviations in the protective field co-ordinates may occur, which are nonetheless visible on-screen. Warning fields are always segmented fields. If you have defined a warning field as a rectangle or semicircle, it is automatically converted into a segment with the appropriate dimensions. Change scale of a segmented field When you have defined a segmented field you can enlarge or reduce it in scale.

• •

Select Edit – Select All to select all the points in the field. Pick up one of the marked points with the mouse and drag the field to the size you want.

Each point is dragged on the measuring beam of its sensor away from or towards the zero point as appropriate.

8 008 316/O801/07-07-04 Technical Description • PLS © SICK AG • Industrial Safety Systems • Germany • All rights reserved

PLS_TB_GB_06_05_02_M844.pmd

47

08.07.2004, 15:55

47

Page 48

Copy and paste fields You can copy fields to the clipboard and paste them at a different location. But you cannot mix field types: you can only paste a protective field back in as a protective field, and a warning field to a warning field.

•

From the menu select Edit – Copy to copy the selected field to the clipboard.

•

Select Edit – Paste to paste the field from the clipboard.

You can then edit the field you have just pasted as usual.

Save individual fields You can save individual fields as files so that they are available for use in other configurations.

• •

From the menu select Edit – Copy To... and save the current field under the desired file name on the hard disk or on a floppy disk. To insert the stored field at the desired location, such as in another configuration, select Edit – Paste From... and enter the file name and storage location.

The field is inserted. You can edit the field as normal.

Fix co-ordinates When editing a segmented field you can fix one of the coordinates of a point. This may be necessary when the coordinate in question must not be changed, such as when configuring a protective filed for a narrow alley.

• •

From the menu select Edit – Field Co-ordinates. In the list select the point whose position you want to change and click on “Edit”.

This dialog window appears.

• •

Enter the co-ordinates you want for x and y. Select which co-ordinates must not deviate from the entered value, for example “Fix X-value”, and click on “Calculate”.

The next closest point on a measuring beam with the desired co-ordinates is calculated.

•

48

The calculated co-ordinates are displayed. To accept them, click on “OK”.

8 008 316/O801/07-07-04 Technical Description • PLS © SICK AG • Industrial Safety Systems • Germany • All rights reserved

PLS_TB_GB_06_05_02_M844.pmd

48

08.07.2004, 15:55

Page 49

9.5 Teach-in protective field You can teach-in protective fields. To do so, you run over the contours of the desired protective field with the active sensor, and die PLS stores the learned contour. You have to check learned protective fields. You can also edit a learned protective field subsequently, just like any other segmented field.

• • •

From the “Active Field” list select the protective field. From the menu select Monitoring Range – Teach-in. Or click on the “Teach-in Monitoring Range” button on the toolbar.

This dialog window appears. The protective field is represented on-screen as a coloured area. The active sensor scans its surroundings and shows you the results. The contour you see on-screen is the largest possible extent of the protective field (the precise contour of the protective field is based on the ambient contours).

•

If you want to reduce the size of the learned contour, run a target (e.g. a piece of cardboard, at least 10 x 10 cm in size) slowly along the edge of your desired protective field.

The contour of the protective field is reduced at the relevant point. On the screen you can track how the protective field takes on the taught-in contour. Note: To prevent fixed obstacles in the scanning plane subsequently producing false signals, 13 cm (= max. measuring error of PLS) is automatically deducted from the learned contour. Take this into account as appropriate when running over the protective field. Also note that the teach-in process may result in an additional error of 4.5 cm.

•

To terminate teach-in, deactivate the “Teach-in Monitoring Range” button.

8 008 316/O801/07-07-04 Technical Description • PLS © SICK AG • Industrial Safety Systems • Germany • All rights reserved

PLS_TB_GB_06_05_02_M844.pmd

49

08.07.2004, 15:55

49

Page 50

This dialog window appears. You now have three options: – You can reject the taught-in protective field, – you can edit it as a segmented field, – or you can check it and then activate it in the PLS. Reject protective field: • Click on “Cancel”. The taught-in protective field is rejected and the old field retained. Edit protective field: Click on “Edit”. You can now edit the taught-in protective field like a segmented field and then transmit it to the PLS.

•

Check protective field: Click on “Check”.

•

The taught-in protective field is shown on-screen. The space contour of the sensor is displayed for comparison purposes.

•

Infringe the contour of the protective field intentionally until you have covered all 361 points and measuring beams. Here it is important that this is carried out in a corridor reaching 70 cm into the protective field.

The number of checked points is displayed in the status bar at the bottom of the screen. This dialog window appears automatically as soon as you have checked all the points. If you want to prematurely cancel the check:

•

•

Deactivate the Monitoring Range – Teach-in menu function, or deactivate the “Teach-in Monitoring Range” button on the toolbar. The same dialog window appears.

Click on “Yes” to transfer the monitoring range into the PLS and confirm with “OK”.

The taught-in protective field is now active in the PLS.

Note: You can also edit the taught-in protective field subsequently and then transmit it as a segmented protective field to the PLS.

50

8 008 316/O801/07-07-04 Technical Description • PLS © SICK AG • Industrial Safety Systems • Germany • All rights reserved

PLS_TB_GB_06_05_02_M844.pmd

50