The text of a manual · part 4 of 8

Technical Description: Proximity Laser Scanner PLS, pages 31 to 40

Pages 31 to 40 of 78

The original document is the PDF (2.3 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Sick PLS101

Page 31

+24V

1)

X1.

x y

3

PLS 8 k1

9 k3 k2

5 k3 x

1 y z k1 k1

X2.

k2 k3 z k1 k3 k2

4)

K1 k3 k2

4)

K2

K3

4)

2)

0V

Evaluation of PLS protective outputs (OSSDs) by relay with positively-driven contacts, mode: without restart inhibit

+24V

1)

X1.

x y

3

PLS 8 k1 k2 x

9 y z k1

5 1 k2

X2.

Y36 S12

S52 z

A1 13 23 33 41 pilz PNOZ8

S1

Y37 Y2 A2S21 S22 14 24 34 42 k1

H2 k2 K1

K2

0V

PNOZ 8 / With restart inhibit and contact monitoring 8 008 316/O801/07-07-04 Technical Description • PLS © SICK AG • Industrial Safety Systems • Germany • All rights reserved

PLS_TB_GB_06_05_02_M844.pmd

31

08.07.2004, 15:54

31

Page 32

+24V

1)

X1.

x

S1

3

PLS 8 k1

9 k3 y k2

5 k3 x

1 y z k1 k1

X2.

k2 k3 k3 z k1 k3 k2

4)

K1

K2 k3 k2

4)

K3

4)

0V

Evaluation of PLS protective outputs (OSSDs) by relay with positively-driven contacts, mode: with restart inhibit

+24V

S1

1)

k1 k2 y x k1 k2 x

3)

y z

A1 A2 PE To PE T13T14X1 1X12 T21 T22X21X22 13 23 31 k1

LCU-X k2

C1 D1 PE C2 D2 PE T3 T4 C3 D3 PE C4 D4 14 24 32 z

X1. 3

PLS 8 9 5 1

K1

K2

X2. 0 V PE

LCU-X/ Protective operation with restart inhibit and contact monitoring

32

8 008 316/O801/07-07-04 Technical Description • PLS © SICK AG • Industrial Safety Systems • Germany • All rights reserved

PLS_TB_GB_06_05_02_M844.pmd

32

08.07.2004, 15:54

Page 33

Information about the connection examples Note: Use only relays with positively-driven relays. The FC elements switched in parallel with the contactors are for arc suppression. 1) Output circuits. These contacts are to be inserted into the control unit so that the hazardous state is eliminated when the output circuit is opened. In categories 3 and 4 in accordance with EN 954-1 this insertion must be in two channels (x, y paths). Single-channel insertion into the control path (z path) is only possible with single-channel control and taking account of the risk analysis. 2) To safeguard activation of K1 and K2 during the switchover phase, K3 should be executed with a release delay in accordance with the contactors used and the operating voltage. The control circuits must be provided with a selective overcurrent protection device (fuse). 3) The potential equalisation must be provided if the OV potential of the power supply unit is not connected with the protective conductor (PE) (VDE 0160). 4) Voltage-dependent resistors for maximum operating AC voltage VRMS = 25 V

8 008 316/O801/07-07-04 Technical Description • PLS © SICK AG • Industrial Safety Systems • Germany • All rights reserved

PLS_TB_GB_06_05_02_M844.pmd

33

08.07.2004, 15:54

33

Page 34

4 031 580

Connecting the interface connector PLS type PLS 101-312 has a universal interface. Unmodified, it operates as a RS 232 interface and so can be connected to standard computers without any problems. Where long cable lengths (over 15 metres) or high data transfer rates are required, you can modify the interface into a RS 422 interface. There are two ways of doing this: either connect pins 7 and 8 with a jumper, or use the RS 422 interface cables, which already include the jumper (see Chapter “Accessories” in the Appendix). When assembling the cables yourself, make sure that the cable shielding is attached. Contacting the shielding at both ends is recommended if a RS 232 connection is being used. When deploying an RS 232 connection, the shielding should only be connected to one end. The shielding should be applied to the computer (or LSI).

34

Stand alone

Sensor with LMI with LSI

NC RXD- RXDRXD RXD+ RXD+ TXD TXD+ TXD+ TXD- TXDNC NC GND GND NC NC NC RS-422 NC RS-232 NC NC NC NC

6 7 8 9

1 2 3 4 5

Cable: Ø4 ... Ø8 mm 4 x max. 0,5 mm 2 Host shielded PIN PC(RS-232) PC(RS-422)/LMI LSI 1 NC RXDRXD2 RXD RXD+ RXD+ 3 TXD TXD+ TXD+ 4 NC TXDTXDshield 5 GND GND Housing 6 NC NC NC 7 NC NC NC 8 NC NC NC 9 NC NC NC

PIN 1 2 3 4 5 6 7 RS-422 8 9

RS-232 RS-422

Interface connector for PLS type 101-312

8 008 316/O801/07-07-04 Technical Description • PLS © SICK AG • Industrial Safety Systems • Germany • All rights reserved

PLS_TB_GB_06_05_02_M844.pmd

34

08.07.2004, 15:54

Page 35

Short-term connection to a PC You normally only connect the PC to the sensor for programming purposes, for example when using the sensor to protect a hazardous area. All settings and fields remain stored in the sensor after the PLS is disconnected from the PC, until changed again by you. The sensor will not lose its data even in the event of a power failure. To connect to the PC, use an interface cable (refer to the Appendix under “Accessories”). Note: If you want to connect a sensor to a computer by a RS 422 interface, you must use a suitable cable. Refer to the notes on switching interfaces on the previous page.

•

Remove the connection box over the interface socket on the PLS.

Note: When the connection box has been loosened, the PLS conforms only to protection class IP 40.

• • • •

Connect the sensor interface to the PC. Programme the PLS. For detailed information refer to the PSI/LSI user software description as from Chapter 9. Detach the interface cable from the PLS. Reconnect the connection box over the interface socket and screw it in tight.

Note: The pin assignment of an RS 422 interface is not standardised. Compare the pin assignment of the connecting cable with the one an the PC and adapt it accordingly.

Permanent connection to an evaluation computer If you want to continuously evaluate the measurement data of the PLS using the RS 422 interface (for example, because of the higher data transfer rate) you must connect the PLS permanently to an evaluation computer.

•

Wire the 9-pin sub-D connector in the connection box with a suitable cable (RS 422 twisted pair). You can choose whether to route the cable out of the box upward or to the rear.

Note: The cable outlet is PG 9 size, and is suitable for all cable diameters from 4 to 8 mm.

• •

Plug the connection box into the PLS and screw it in tight. Lay the cable permanently to the evaluation computer or to the vehicle’s on-board computer.

Note: Lay all cables so that they are protected against damage.

8 008 316/O801/07-07-04 Technical Description • PLS © SICK AG • Industrial Safety Systems • Germany • All rights reserved

PLS_TB_GB_06_05_02_M844.pmd

35

08.07.2004, 15:54

35

Page 36

9

Programming the PLS with the User Software 9.1 Installing the user software Note: This chapter describes how to programme a PLS proximity laser scanner. If you want to deploy one or more PLS together with a SICK LSI (Laser Scanner Interface), refer instead to the technical description of the LSI, Chapter 9: “Programming the LSI with the User Software”. The PLS/LSI user software as from version 3.61 can be used to programme PLS or PLS/LSI systems. lf you have older PLS/LSI user software installed on your PC which you want to continue using, specify a different programme directory/folder when installing the new PLS/LSI software. System requirements Please observe the respective hardware requirements of the operating systems listed here. – min. 4 MB available hard disk capacity – Windows 95TM, Windows 98TM or Windows NTTM 4/SP4 – WindowsTM 3.11 available upon request – min. 80486 processor – min. 4 MB main memory – Colour monitor recommended – Installed graphic printer driver When installing your PLS/LSI user software you are guided by the installation pro-gramme. All you have to do is start the programme as follows:

• • •

• • •

Boot your PC. Insert the PLS/LSI programme disk in the disk drive of your PC. Under WindowsTM 3.11: Select the menu option File – Run in the File Manager Windows 95TM, Windows 98TM or Windows NTTM 4/SP4: select Run in the Start menu. Select and run the programme “Install.exe”. If necessary, enter the programme directory/folder where you want the new PLS/LSI software to be installed. Follow the on-screen instructions.

After the installation is finished a message box appears to tell you that the setup has been completed successfully. The PLS/LSI user software is now installed. You can run it at any time by clicking on its icon.

36

8 008 316/O801/07-07-04 Technical Description • PLS © SICK AG • Industrial Safety Systems • Germany • All rights reserved

PLS_TB_GB_06_05_02_M844.pmd

36

08.07.2004, 15:54

Page 37

9.2 What to do

Other options

Note: When the programme starts you are automatically logged on as the machine operator. As such, you can poll data but cannot transmit any. To be able to transmit configuration data and monitoring areas to the PLS, you must log an as an “Authorised Client”. How to log on is described in Section 9.3.

In addition to the essential steps, you can use a number of other options when configuring your PLS system.

In the status bar at the bottom of the screen you will see a colour code for the on-screen display of the protective and warning fields. Essential steps In creating a new configuration you are guided by the PLS/LSI user software. It guides you through the following steps:

•

•

Configure hardware: You log the PLS on and define the restart inhibit mode of the protective outputs (OSSDs). You select the number of multiple evaluations and define whether you are using the sensor for area protection or for protection on a vehicle. You also define the switching behaviour of the “Weak Signal” output. Define monitoring range: You define the range to be monitored by the PLS. If you wish, you can also determine the shape and size of the protective and warning fields here.

•

Send configuration to PLS: You now transmit all the configuration settings you have made to the PLS. You must be logged on as an “Authorised Client” to be able to do this.

•

Edit monitoring range: Here, if you wish, you have the chance to alter the shape and size of the protective and warning fields.

•

Send monitoring range to PLS: Finally you transmit the protective and warning fields to the PLS. For this too, you must be logged on as an “Authorised Client”.

– Edit fields: To edit the protective and warning fields the PLS/LSI user software provides you with a number of useful edit functions. – Teach-in and check protective field: In the teach-in process you run over the contours of the desired protective field with the sensor active, and the PLS stores the learned contour. You have to check learned protective fields. You can also edit a learned protective field subsequently, just like any other segmented field. – Monitor protective field: You can monitor the protective and warning fields during operation using a connected PC. You can also store the defined space contours of the sensor as a check. – Check settings: You can view, check and print all configuration settings in a page view. – Receive and store configuration: You can receive and print the configuration data stored in the PLS. You can save any configuration to the hard disk or to a floppy disk. – Change password: To protect your PLS against manipulation, you should change the logon password. – Change screen view: You can zoom in, zoom out or move the screen view, for example. – Interrogate fault memory (system diagnosis): For troubleshooting purposes you can interrogate the fault memory of the PLS.

When you have completed these steps the PLS system is ready for operation. Note: Change the logon password to protect your PLS system against manipulation (see Chapter 9.13). Log your configuration data stored in the PLS, and back up the configuration on the hard disk or on a floppy disk (see Section 9.12).

8 008 316/O801/07-07-04 Technical Description • PLS © SICK AG • Industrial Safety Systems • Germany • All rights reserved

PLS_TB_GB_06_05_02_M844.pmd

37

08.07.2004, 15:54

37

Page 38

9.3 Starting: the initial configuration The PLS is shipped with certain pre-configured settings. This section describes how you can adapt those settings to your application.

• •

Switch on your PLS system (it takes a few seconds to start up). Start the PLS/LSI user software.

The following dialog window appears:

•

Click on “Yes”.

The PC receives the pre-configured settings and displays them on-screen.

This dialog window appears. To be able to send the configuration and monitoring area to the PLS, you must log on as an “Authorised Client”.

• •

Select “Authorised Client” from the category list. Enter the password “SICK_PLS” and click on “Logon”.

You are now logged on as an “Authorised Client” (see status bar at bottom of screen). Note: Always log off when leaving your workstation! This will prevent unauthorised persons from manipulating your PLS system.

38

8 008 316/O801/07-07-04 Technical Description • PLS © SICK AG • Industrial Safety Systems • Germany • All rights reserved

PLS_TB_GB_06_05_02_M844.pmd

38

08.07.2004, 15:54

Page 39

Configure hardware You can edit the received configuration or create a new one. To create a new configuration:

• •

From the menu select File – New and click on “PLS Configuration”. Click on “OK”.

This dialog window appears. This is where you set the sensor type you want to work with.

• •

Select your sensor type or have the sensor automatically detected by clicking on “Detect”. Click on “Continue”.

The remaining steps to follow and dialog windows which appear are the same as the following steps under “Edit configuration”. To edit the received configuration:

• •

From the menu select PLS – Configuration – Edit. Or select the “Edit Configuration” button from the toolbar.

This dialog window appears. Here you can enter a symbolic name for the sensor and the monitoring range.

• •

Enter a name for the sensor and the monitoring range. These names have no functional significance, they are only intended as an aid to better allocation. Click on “Continue”.

This dialog window appears. This is where you set the address under which the PLS is to be addressed.

•

•

Select whether you want to use a universal or single address. Universal address (zero): This is the recommended setting. If you set “Universal address”, the stored configuration can be transferred at a later time to another PLS. Single address (between 1 and 99): If you set “Single address” you assign the PLS the address specified here for transferring the configuration. It is then only possible to reload a configuration at a later time if the address specified here and the one stored in the PLS match. This makes sense when you want to ensure that a configuration saved as a file can only be transmitted to specific PLS units. Click on “Continue”.

8 008 316/O801/07-07-04 Technical Description • PLS © SICK AG • Industrial Safety Systems • Germany • All rights reserved

PLS_TB_GB_06_05_02_M844.pmd

39

08.07.2004, 15:54

39

Page 40

This dialog window appears. This is where you set the restart behaviour of the output and the start-up testing.

•

Select how the PLS is to restart after a protective field infringement. With restart inhibit: The system only restarts after a protective field infringement or a reset when the protective field is free and the restart button is pressed. Without delay: The system restarts immediately as soon as the protective field is free. Delayed by n seconds: The system only restarts when the time set here has elapsed after the protective field has become free again.

• Here you can select whether you want to work with start-up testing. If you select this option you must intentionally interrupt the protective field one time after switching on the system. Only then is the system ready for operation.

•

•

This allows you to ensure that after switching on the machinery, the machine operator must check that the PLS is detecting properly by infringing the protective field before he starts work. Click on “Continue”.

This dialog window appears. This is where you define the field of application of your PLS system.

• •

Select whether you want to use the PLS for area protection or for protection on a vehicle. Click on “Continue”.

This dialog window appears. This is where you set how often (that is, in how many consecutive scans) the sensor must detect a foreign body in the protective field before it signals an infringement (between 2 and 16 scans are possible).

•

•

40

Enter the desired number of scans. Note: For safety reasons, always select the lowest possible setting! If you increase the setting the system will become more stable, but will also respond more slowly. In this way you can achieve a good level of availability, for example in an environment with a high dust concentration. The current response time is shown on the box. Click on “Continue”.

8 008 316/O801/07-07-04 Technical Description • PLS © SICK AG • Industrial Safety Systems • Germany • All rights reserved

PLS_TB_GB_06_05_02_M844.pmd

40

08.07.2004, 15:54