Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 6 of 8

Operating Instructions: OTS400 Omni Tracking System, pages 51 to 60

Pages 51 to 60 of 74

The original document is the PDF (2.9 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Sick OTC400-000

Page 51

Operating Instructions

Parameterization

Chapter 8

OTS400 string conventions. When the parameter set is saved as a configuration file in CLV Setup, these parameters are also included and are also downloaded to the OTS400/OTC400 and bar code scanner. 8.3.5

CLV Setup – online help

The procedure for setting the bar code scanner parameters is supported by the online help function, which is displayed in an HTML browser, such as Internet ExplorerTM. You can call up context-sensitive help on each parameter as well as a description of its function and permissible values. Displaying the help function: ¾

Press the <F1> key. The browser is launched automatically and displays the help topic. If the program cannot find a browser, it asks you to specify the storage location on the hard disk.

¾

Enter the storage location and link CLV Setup with the browser. Confirm the dialog box. The link is then stored and the browser window opens.

Using the help function: To display information on a tab, click the tab in the top, horizontal frame. The vertical frame on the left-hand side of the screen then displays a list of parameters, which you can click for a detailed explanation. To display an overview of the help function, choose ‘Help’ -> ‘Contents’ on the menu bar. Recommendation Use the <ALT>+<TAB> keys to switch between the ‘CLV Setup’ and ‘CLV Setup Help’ applications and prevent several browser windows from being opened. 8.3.6

Tabs (overview)

This section only describes the tabs for the OTS400/OTC400. For a description of the CLVs connected in the OPS, please refer to the Operating Instructions for the relevant bar code scanner. The OTS400/OTC400 does not have a separate ‘Reading configuration’ tab. The settings required in the OPS, therefore, must be made on the respective bar code scanner. Device configuration You can use this tab to define: •

The device number

•

How odette filters are processed

•

How the information on the focus position is distributed

•

The configuration (master / slave / standalone)

•

The function assignment of the switching outputs (outputs 1...4 and relay output)

•

How the reading pulse is processed

•

How the incremental input(s) is/are processed

•

How the switching inputs are processed (sensors 1-1 ... 1-7, 2-1 ... 2-4)

•

How the match code is processed

8008869/RA61/2007-07-30

© SICK AG · Auto Ident · Germany · All rights reserved

8-7

Page 52

Chapter 8

Parameterization

Operating Instructions OTS400 Omni Tracking System

Code configuration You can use this tab to define: •

The individual codes that are activated for evaluation

•

The number of identical reads

•

The min. and max. number of bar codes to be read/output

Recommendation To enhance the reading reliability, we recommend that you only activate those code types and code lengths that are relevant. Host interface You can use this tab to define: •

The active interface version (RS 422/485 or RS 232)

•

The protocol for data transfer

•

The start and stop characters

•

The data format and transfer rate

Data string You can use this tab to define: •

The data output format on the host interface

•

The constants and reading diagnosis data in the header, separator, and terminator

•

The position of the separator in the data string

•

The output format for no reads and the contents of the error string

•

The test string function

•

The output sequence and sort criteria if more than one bar code is read during each reading interval

•

The activation criteria and structure of the format mask

•

Special features (S2000, Cancel/Bell...)

Auxiliary interface You can use this tab to define: •

The operating mode of the auxiliary interface

Slave configurations You can use this tab to define: •

The CAN data rate1)

•

The end of the reading field

•

The list of salves in the network

1) it is important that the same CAN data rate be set in the OTS400/OTC400 and on the connected bar code scanner.

Extras These tabs can be used to edit unknown parameters after they have been uploaded to CLV Setup from the OTS400/OTC400 or the bar code scanner.

8-8

© SICK AG · Auto Ident · Germany · All rights reserved

8008869/RA61/2007-07-30

Page 53

Operating Instructions

Parameterization

Chapter 8

OTS400

8.3.7

Parameterization guide

Change the following parameter settings in the default parameter set: 1a. Read: 1 bar code per reading pulse •

Code types

⇒ ‘Code configuration’

•

Decoder

⇒ ‘Code configuration’

•

Scanning frequency

•

Assignment table

⇒ under ‘Reading configuration’ in connected CLVs

•

Trigger source for dynamic focus control

⇒ under ‘Reading configuration’ in connected CLVs

•

Autofocus function

⇒ under ‘Reading configuration’ in connected CLVs

•

Focus positions (DC)

⇒ under ‘Reading configuration’ in connected CLVs

•

Edit area parameters

⇒ under ‘Reading configuration’ in connected CLVs

•

Trigger source for the reading pulse

⇒ ‘Device configuration’

⇒ under ‘Reading configuration’ in connected CLVs

1b. Read: several bar codes per reading pulse in addition to a: •

Minimum and maximum number of codes

⇒ ‘Code configuration’

1c. Read: identical code type with identical data contents in addition to b: •

Capture range

⇒ ‘Device configuration’

•

Code comparison

⇒ ‘Device configuration’

1d. Restrict evaluation range of the scan line (per distance configuration) in addition to a and b: •

Minimum and maximum reading angle

⇒ under ‘Reading configuration’ in connected CLVs

2. Host interface •

Type

⇒ ‘Host interface’

•

Communication parameters

⇒ ‘Host interface’

•

Protocol (if necessary)

⇒ ‘Host interface’

3. Data output string on the host interface •

Contents of the header, separator, terminator

⇒ ‘Data string’

•

No read format

⇒ ‘Data string’

•

Test string (if required)

⇒ ‘Data string’

•

Output string (if required)

⇒ ‘Data string’

8008869/RA61/2007-07-30

© SICK AG · Auto Ident · Germany · All rights reserved

8-9

Page 54

Chapter 8

Parameterization

Operating Instructions OTS400 Omni Tracking System

8.3.8

Completing parameterization

Current parameter set unchanged: 1. If you have not made any changes, or if you want to reject these changes, choose ‘File’ -> ‘Exit’. CLV Setup then closes. 2. Switch off the power supply to the OTS400/OTC400 and bar code scanners in the OPS. The parameter set that was last saved permanently remains valid. Current parameter set was changed: 1. Download the modified parameter set to the OTS400/OTC400 or bar code scanner: Click the ‘page to bar code scanner’ icon in the toolbar. CLV Setup transfers the parameter set to the OTS400/OTC400 or bar code scanner and asks you to select the storage option. 2. Choose the ‘Permanent’ option. The OTS400/OTC400 or bar code scanner then uses the new parameter set. 3. Save the changes as a new configuration file in CLV Setup on the PC or overwrite the existing file: from the ‘File’ menu, choose ‘Save as’. 4. Enter the path and file name in the dialog box and confirm your entries. CLV Setup saves your configuration file. 5. From the ‘File’ menu, choose ‘Exit’. CLV Setup closes. 6. Switch off the power supply to the OTS400/OTC400 and bar code scanners in the OPS.

8.4 Backup concept for parameter sets You can use the following methods to activate the current parameter set: OTS400/OTC400 and bar code scanner: 1. Download it from CLV Setup to the OTS400/OTC400 or bar code scanner and save it permanently. See also Section 8.3.4 Transferring parameter sets between CLV Setup and the OTS400/OTC400 or CLV. CLV Setup 2. Save the configuration file ‘*.scl’ in CLV Setup. See also Section 8.3.8 Completing parameterization.

8-10

© SICK AG · Auto Ident · Germany · All rights reserved

8008869/RA61/2007-07-30

Page 55

Parameterization

Operating Instructions

Chapter 8

OTS400

8.5 Editing area parameters You must enter each individual bar code scanner in the OPS in a coordinate system. ¾

To do so, enter the relevant data for all of the connected bar code scanner in the corresponding window under ‘Code configuration’. Fig. 8.2 shows the angles and coordinates.

RA50 Proj. Fig. 8-1: The OPS coordinate system

8008869/RA61/2007-07-30

© SICK AG · Auto Ident · Germany · All rights reserved

8-11

Page 56

Parameterization

Chapter 8

Operating Instructions OTS400 Omni Tracking System

Area parameters: Coordinate

X y z

Orientation

Transport direction

Perpendicular to TD

Vertical on belt

Zero point

Trigger – Photo electric switch PS (second PS if 2 PS)

Belt edge right, in transport direction

Top edge of belt

Table 8-2: Coordinates

Each bar code scanner must be provided with 3 angles for positions in the area (counterclockwise): • alpha :

angle of rotation of the scanning direction from the conveyor direction

• beta :

skew angle of scanner (for oscillating mirror: direction of oscillation ), rotation about an axis through the scanner that is parallel to the scanning direction, after alpha has been applied.

Negative angle values are not allowed in CLV Setup. An angle of –10°, therefore, corresponds to 350°. • gamma :

angle of rotation of the scanner about an axis that is parallel to the conveyor direction; value 0 : vertically downwards, after alpha and beta have been applied

Parameter

Description

Resolution, unit

Min. value

Max. value x coordinate

Distance: OPS – frame pos. to scanner (center light emission front panel)

1 mm

-9999

+9999 x Offset

Distance: start – PS to OPS frame pos. (start) (identical for all bar code scanners)

1 mm

-3000

+3000 y coordinate

Scanner position perpendicular to conveyor direction

1 mm

-3000

+3000 z coordinate

Scanner height above belt

1 mm

-2000

+2000

Alpha

Angle of rotation of scanning 1 degree direction from conveyor direction

0

360

Beta

Skew (scanner)

1 degree

0

360

Gamma

Angle of rotation of scanner perpendicular to conveyor direction

1 degree

0

360

INC Scale

Travel increment scale

0.01 mm

0 (no increment)

100 mm

Table 8-3: Area parameters

In the case of scanners with oscillating mirrors, the geometry parameters apply in a similar manner to the zero position of the oscillating mirror (CW 50).

8-12

© SICK AG · Auto Ident · Germany · All rights reserved

8008869/RA61/2007-07-30

Page 57

Operating Instructions

Maintenance

Chapter 9

OTS400

9

Maintenance

9.1 Maintenance during operation Information on maintaining and repairing the bar code scanners is provided in the relevant Operating Instructions. The optical surfaces in the OPS must be cleaned at regular intervals. ¾

Clean the optical surfaces on external reading pulse generators and/or object-height detection systems using sensors (e.g. photoelectric reflex switches) with a mild, water-soluble, non-scouring detergent and a soft, lintfree cloth. Dirt on these surfaces may affect the switching behavior.

The OTS400/OTC400, for example, does not require further maintenance.

9.2 Maintenance The OPS does not require maintenance. Its self-monitoring functions ensure fault-free operation over a long period of time. Any device or malfunctions on the OTS400/OTC400 or bar code scanner are output via the terminal interface (see Chapter 10 Error messages).

9.3 Disposal Defective devices that have been removed from service should always be disposed of in an environmentally friendly manner. Further information for the bar code scanners used in the OPS are provided in the respective Operating Instructions. In the case of the OTS400/OTC400, please note the following: 1. Always observe the national waste disposal guidelines. 2. Disassemble the housing of the OTS400 and OTC400 and submit it for recycling. 3. Disassemble electronic modules and connecting cables and dispose of them as special treatment waste. 4. Remove the reading window from the OTS400 and submit it for plastic recycling (PC). SICK AG does not accept any unusable or irreparable devices at present.

8008869/RA61/2007-07-30

AG · Auto Ident · Germany · All rights reserved

9-1

Page 58

Chapter 9

Maintenance

Operating Instructions OTS400 Omni Tracking System

Notes:

9-2

© SICK AG · Auto Ident · Germany · All rights reserved

8008869/RA61/2007-07-30

Page 59

Operating Instructions

Troubleshooting

Chapter 10

OTS400

10 Troubleshooting 10.1 Overview of errors and malfunctions 10.1.1 Mounting errors •

Bar code scanners are not aligned correctly with the object

•

Reading pulse sensor is positioned incorrectly

•

Sensor for object-height detection is positioned incorrectly

10.1.2 Electrical installation errors •

Ports on the OTS400/ OTC400 are connected incorrectly (wiring error)

10.1.3 Parameterization errors •

Functions are not adapted to the local conditions, e.g. communication parameters on the host interface are incorrect

•

The technical limits of the bar code scanners have not been taken into account, e.g. the relationship between the available scanning frequency and the reading distance

•

The coordinates of the bar code scanner in the OPS are incorrect

10.1.4 Malfunctions •

Safety timer for incomplete reading interval has expired

•

Device error (hardware/software)

8008869/RA61/2007-07-30

© SICK AG · Auto Ident · Germany · All rights reserved

10-1

Page 60

Troubleshooting

Chapter 10

Operating Instructions OTS400 Omni Tracking System

10.2 Error messages The OPS outputs error messages on the auxiliary interface of the OTC400. These messages are structured as follows:

type SYS-FAILURE: xxx

Device

Error message

Range

CLV bar code scanner typ = CLV-FAILURE: xxx xxx= 000 ... 299

OTS400/ OTC400 typ = OTC-FAILURE: xxx xxx= 500 ... 599

CANOpen protocol typ = COP-FAILURE: xxx xxx= 300 ... 399 network management typ = NMM-FAILURE: xxx xxx= 400 ... 499

Table 10-1: Types of error messages

In addition to error messages (FAILURE), the OPS also outputs general messages (MESSAGE) that contain information only. 10.2.1 Overview of the error messages for the CLV490 bar code scanner The following table contains a general overview of the error messages for the bar code scanner. For a more detailed description, please refer to the relevant Operating Instructions. 1. To display the error messages in CLV Setup, select the bar code scanner (under Options, Parameters in the OTS network) 2. Select the extended terminal mode. Message

Meaning

Remedy

“CLV SYS- Failure: xxx” (CLV system error)

The bar code scanner has diagnosed a system error.

xxx = 000 ... 299

The “Device Ready” LED does not light up or extinguishes.

If the error occurs again after the bar code scanner has restarted, contact the SICK Service department.

Error code: 011 012 013 051 061 071 091 ... 095 101 ... 118 130 131 132 133 201 ... 215 data error (external RAM) address error (external RAM) insufficient RAM (external RAM) speed out of tolerance (mirror wheel) Mirror interval out of tolerance Laser shutter failure focus adjustment error parameter memory error amplifier setting invalid background profile center reading angle RA-50 not plausible brightness value overrun DSP failure

The system is restarted.

Table 10.2: SYS failures – CLV490 bar code scanner (excerpt)

10-2

© SICK AG · Auto Ident · Germany · All rights reserved

8008869/RA61/2007-07-30