Page 61

Operating Instructions

Troubleshooting

Chapter 10

OTS400

10.2.2 Overview of the error messages for the OTS400/ OTC400 The OTS400/OTC400 displays an error message for each bar code scanner if it does not respond in the CAN network. Error messages 502 to 525 are used for this purpose (502 for CLV 1, 503 for CLV 2.... 525 for CLV 24). Internal bar code scanner errors are in the range from 527 to 550 (527 for CLV 1, 528 for CLV 2... 550 for CLV 24). To determine the exact error, see Table 10.2. ¾

If the error occurs again after the CLV has restarted, contact the SICK Service department. This also applies to error messages between 300 and 499.

10.3 Troubleshooting table Table 10.3 contains a list of further malfunctions that can occur as a result of incorrect parameter settings or errors during operation. It is assumed in each case that only one bar code is read with each reading pulse. By connecting a terminal/PC to the auxiliary interface of the OTC400, you can display error messages and monitor data traffic on the host interface. Malfunction

Possible cause

Remedy

The OTS400/OTC400 is not ready. The “Device Ready” LED is not lit. The “Dev Rdy” switching output (default setting of output 1) is blocked.

- The power supply to the OTS400/ OTC400 has not been switched on

- Check the power supply. Check the bar code scanner (listen to the housing): can you hear the polygon mirror wheel running?

- The OTS400/ OTC400 is not in “Reading mode”

- Exit the control menu

- The OTS400/ OTC400 has diagnosed a device error during the self-test

- Analyze the error messages using Section 10.2.2. Switch the device off and on again

- Sensor not connected correctly

- Check the electrical connection and functioning of the sensor

- Incorrect trigger source set

- Check the setting under the “trigger source” menu option

The connected bar code scanners cannot be clocked via the “Sensor” switching input. The “Sensor” LED on the individual LEDs does not light up. The scan line is not visible.

- OTS400 mode not activated in bar code scanner - CAN baud rate in the OTS400/ OTC400 and bar code scanner do not match

The “Read Result” LED does not light up when the event occurs that triggers the parameterized function.

- Incorrect function parameterized

- Check the setting under the “Good Read - Output” menu option

- The OTS400/OTC400 is not in “Reading mode”

- Switch to “Reading mode”

- No reading pulse present (e.g. sensor signal or command string missing)

- Check reading pulse supply

The “Good Read” switching output does not supply a pulse. The OTS400/OTC400 does not transmit a reading result to the host. The “Data” LED is not lit.

- No incremental signal present The OTS400/ OTC400 only transfers the error status ST=3 in the reading result to the host

- The OTS400/ OTC400 has diagnosed as device error during the self-test

- Analyze the error messages using Section 10.2.2.

Table 10-3: Troubleshooting table

8008869/RA61/2007-07-30

© SICK AG · Auto Ident · Germany · All rights reserved

10-3

Page 62

Chapter 10

Troubleshooting

Operating Instructions OTS400 Omni Tracking System

Malfunction

Possible cause

Remedy

The OTS400/OTC400 repeatedly - There is no bar code in the reading field - Synchronize the pulse supply to the transmits the error status ST=2 in during the reading pulse bar code scanners with the appearthe reading result to the host ance of the bar code in the reading (message on terminal interface: field - The evaluation criteria, e.g. code type and “No code!”) code length, are incorrectly set - Check the individual menu options of the enabled code types (code configuration) - If the autofocus function is not used: the focus position has not been adapted to - Check the corresponding parameters the reading situation (code outside reading range) - The bar code quality is too poor - Check the reading function using a standard reference code Control characters contained in the code, header, separator, or terminator appear as “@” in the data output string (Code 39, Code 128, Code 93, and EAN 128)

- When the data is output in ASCII format, the OTS400/OTC400 replaces each control character in the protocol frame with the character “@” in order to avoid transmission errors

- Set the “Output Hex-ASCII” menu option to “yes” (The OTS400/ OTC400 then outputs the code contents in Hex format)

- The format mask refers to characters that are not contained in the code

- Correct or delete the format mask

In “immediate” output mode, the bar code scanner outputs the reading result as a no read at the end of the reading pulse

- The parameterized minimum number of - Check the “Min. number of codes” bar codes to be read is greater than the menu option actual number that occurred in the reading pulse - The evaluation criteria, e.g. bar code type, - Check the individual menu options for bar code length, have been defined incorthe enabled code type(s) (code conrectly figuration)

The bar code scanner suppresses the last character of the code in the data output string

- The output of the last character (check digit) may have been disabled

- Check the “Transfer check digit menu option

Table 10-3: Troubleshooting table (continued)

10-4

© SICK AG · Auto Ident · Germany · All rights reserved

8008869/RA61/2007-07-30

Page 63

Operating Instructions

Troubleshooting

Chapter 10

OTS400

10.4 Error status ST in the reading result of a code Value

Meaning

Possible cause

Remedy

0

Good read

-

-

1

Check digit error

• The check digit calculated by the • Check whether the check digit CLV during the read operation calculated in the bar code field does not match the value printed in during the printing operation is the bar code field correct • If the check digit of the bar codes used are sometimes incorrect, deactivate the check digit function

2

No code found that matches the evaluation criteria

• No code present in the reading field of the CLV during the reading pulse

• Synchronize the pulse supply to the CLV with the appearance of the bar code in the reading range

• Code type/length not enabled for decoding in the CLV

• Correct the code configuration parameters

• Reading window covered/dirty

• Check the reading window

3

Device error

• Device defective

Start self-test. If result ≠ 000: inform SICK Service department

5

Required number of identical multiple reads for the code not reached

• Conveyor speed of object too high

• Check conveyor speed

• Scanning frequency too low

• Adjust scanning frequency

• With ladder-type arrangement of the bar code relative to the conveyor direction: code height (bar length) too small

• Check code height

• Print quality too poor

• Check print quality

7

The source of the reading result is the auxiliary input on the terminal interface

• The code was not read by the OTS400/OTC400, but entered subsequently via the auxiliary function of the terminal interface and transferred to the host in a separate data string.

-

9

The “Filter for output” function is also active during the code comparison.

• The scanned object is not carrying a code that matches the specified match code

-

The OTS400/OTC400 has detected valid codes. However, these do not match the active match code(s) Table 10.4: Error status ST

8008869/RA61/2007-07-30

© SICK AG · Auto Ident · Germany · All rights reserved

10-5

Page 64

Chapter 10

Troubleshooting

Operating Instructions OTS400 Omni Tracking System

Value

Meaning

Possible cause

Remedy

A

The “Check max. number of codes” function is activated.

• One object in a set of objects with a constant number of codes, for example, contains more codes than is allowed

• This message indicates an error on the object (e.g. check whether they have been sorted correctly or if one of the objects is incorrect)

• The read 6-character code is not a C32 code. The CLV outputs the error string instead

-

The CLV has detected more codes in the reading pulse than was specified under “Max. number of codes”. Instead of the codes, it outputs the error string repeatedly until the “Max. number of codes” is reached. D

The Code 32 evaluation option is activated for 39. The CLV is attempting to interpret 6-character C39 codes as C32 codes (Ö output of 9-digit decimal values)

Table 10.4: Error status ST (continued)

10.5 SICK Support department If you cannot correct the error using the above measures, the device may be defective. The bar code scanners/the OPS does not contain any components that can be repaired by the user. ¾ •

Please contact your local SICK office or subsidary if an error occurs which cannot be eliminated: The telephone numbers and email addresses are listed on the back page of this manual. For postal addresses see also www.sick.com.

¾

Do not send the device to the SICK Service without first contacting us.

10-6

© SICK AG · Auto Ident · Germany · All rights reserved

8008869/RA61/2007-07-30

Page 65

Operating Instructions

Technical Data

Chapter 11

OTS400

11 Technical data 11.1 OTS400/OTC400 data sheet Type

OTS400

No. of bar codes per object

Max. 10 (with max. 4 scanners)

No. of objects per reading field

Max. 20 (autodiscriminating)

OTC400

Bar code types

Code 39, Code 128, Code 93, Codabar, EAN, EAN 128, UPC, 2/5 Interleaved

Bar code length

Max. 50 characters (max. 600 characters across all bar codes per reading interval)

Print ratio

2:1 ... 3:1

No. of multiple reads

1 ... 99

Optical indicators

26 x LED (status and function indicators)

Reading pulse

3 switching inputs (“Trigger 1, 2, and 3” ) /software triggers

“Host” data interface

RS 232 or RS 422/485, variable data output format, optional bus connection

Data transfer rate

300 ... 38,400 bd

Protocols

SICK Standard, 3964(R)/ RK 512/ Crisplant S2000

Physical configurations

Stand-alone

“Terminal” data interface

RS 232, 9,600 bd, 8 data bits, no parity, 1 stop bit, fixed output format

Functional switching inputs

16 (“Trigger 1..3”, “Travel increment 1..2”, “Sensor 1-1..1-7”, “Sensor 2-1..2-4”) - all inputs are assigned LEDs - optodecoupled, V i max= +30V, non-interchangeable

Functional switching outputs

- 4 (“Output 1 ... 4”) PNP, Io max = 30 mA, short-circuit proof, variable pulse duration (10 ... 990 ms/ 100 ... 9.900 ms), variable result indicator function - 1 (relay output), 24 V DC: max. 1.5 A; 250 V DC: max. 0.2 A; 250 V AC: max. 1.5 A; variable pulse duration (10 ... 990 ms/ 100 ... 9.900 ms), variable result indicator function

Electrical connections

Terminal strips 1 x 9-pin D Sub HD connector “AUX” (diagnosis) 1 x 9-pin D Sub HD socket “CAN” (SICK diagnosis)

Operating voltage

230 V AC –15%/ +10% 50 Hz

24 V DC +20%/ –10%

Housing

Sheet steel, lacquered, PC reading window extruded aluminum section

Electrical safety

To EN 61010-1 (2001-03)

Protection class

III, to EN 61140 (2002-03)

Enclosure rating

IP 65, to EN 60529 (1991-10); A1 (2002-02)

EMC tested

To EN 61000-6-1 (2001-10), EN 61000-6-2 (2001-10), EN 55011 (1998-05), EN 55011/A1 (1999-08), EN 55011/A2 (2002-10)

Vibration/shock tested

To IEC 68-2-6 Test FC/ to IEC 68-2-27 Test EA

Weight

Approx. 10.3 kg (incl. power pack/automatic circuit-breaker)

Operating/storage temperature

0 ... +50 °C/ –25 ... +70 °C

Max. relative humidity

90%, non-condensing

IP 20 approx. 1.3 kg

Table 11-1: Technical specifications of the OTS400/ OTC400

8008869/RA61/2007-07-30

© SICK AG · Auto Ident · Germany · All rights reserved

11-1

Page 66

Chapter 11

Technical Data

Operating Instructions OTS400 Omni Tracking System

11. 2 Dimensioned drawing OTC400

Fig. 11-1: Dimensioned drawing – OTC400

11-2

© SICK AG · Auto Ident · Germany · All rights reserved

8008869/RA61/2007-07-30

Page 67

Operating Instructions

Technical Data

Chapter 11

OTS400

11. 3 Dimensioned drawing OTS400

Fig. 11-2: Dimensioned drawing – OTS400

8008869/RA61/2007-07-30

© SICK AG · Auto Ident · Germany · All rights reserved

11-3

Page 68

Chapter 11

Technical Data

Operating Instructions OTS400 Omni Tracking System

Notes:

11-4

© SICK AG · Auto Ident · Germany · All rights reserved

8008869/RA61/2007-07-30

Page 69

Operating Instructions

Appendix

Chapter 12

OTS400

12 Appendix 12.1

Fundamental principles of omni directional reading and system technology

12.1.1 Why is it necessary to use Omni Portal Systems? In many cases, one bar code scanner is not sufficient to perform the task at hand. This is the case, for example, if the bar code is oriented randomly on one side of the object, or if several bar codes are located on more than one side. For this reason, several bar code scanners are used. The individual reading results are then combined in the OTS400/OTC400 and forwarded to the host as one reading result per object. 12.1.2 What are the basic parameters? •

Path width/ required object width coverage

•

Required depth of field (with readings from above: max. height differences per object)

•

Code type

•

Module width

•

Bar length (height)

•

Velocity used in the application

12.1.3 Basic principles •

Specified reading ranges apply to skew and pitch angles ≤ ± 15°. Applications involving larger pitch and skew angles should be examined carefully.

•

Objects containing a bar code covered by a film can reduce the reading rate of the system. These objects should be examined carefully.

•

Code quality, e.g. EN 1635 3 or EN 1635 4. Closer examination is required if the code quality is poorer.

8008869/RA61/2007-07-30

© SICK AG · Auto Ident · Germany · All rights reserved

12-1

Page 70

Appendix

Chapter 12

Operating Instructions OTS400 Omni Tracking System

12.1.4 Configurations a) OPS 290 2 line scanner 45° with respect to the conveyor direction

A

U

T

O

I

D

E

N

T

A U T O I D E N T

Fig. 12-1: Typical scan line field of an OPS290

• Scanning rate up to 1,200 Hz per scan line • Coverage for module width 0.35 ... 0.5 mm for reads from above: Path width/required object width coverage: 800 mm Object height, max. object height differences: 800 mm • Required minimum bar length (bar code height) for 2 typical code types: Velocity

Bar length for Code 128

Bar length for Interleaved 2/5 (PR 2:1 ... 3:1)

≤ 1 m/s

≥ 18 mm

≥ 17 ... 20 mm

≤ 2 m/s

≥ 20 mm

≥ 22 ... 25 mm b) OPS 490 4 Line scanners 45° with respect to conveyor direction

Fig. 12-2: Typical scan line field of an OPS490

• Scanning rate up to 1,200 Hz per scan line

12-2

© SICK AG · Auto Ident · Germany · All rights reserved

8008869/RA61/2007-07-30