Four pages from the SICK Safety Catalog 2004 on the i200 Lock, a safety interlock with guard locking that keeps a machine guard shut until hazardous motion has stopped. They give a description, technical specifications, switching elements, a product selection table and the actuator and key accessories with part numbers.

Device
Safety interlock with guard lock; the actuator is locked mechanically and released by applying voltage to the solenoid p. 1, 3
Retaining force
2000 N with threaded M5 metal bolts; 1500 N with locating pins p. 2
Solenoid voltage
24 V DC, 110 V AC or 230 V AC, each -15 to +10% p. 3
Housing
Fiberglass reinforced thermoplastic housing with a stainless steel head; IP 65 p. 1, 2
Mounting
Actuator can enter from 3 ways; head rotates 180° p. 1
Ambient temperature
-20 to 60° C p. 2
Cable entries
3 X M 20 p. 2, 3
Weight
0.4 Kg p. 2
LED
Lights when the solenoid is active and the guard can open p. 3
Part numbers
Six versions by solenoid voltage and contacts: 6 025 113, 6 025 115, 6 025 117, 6 025 119, 6 025 121, 6 025 123 p. 3
Actuators
Straight iE200-S1 (5 308 758); flexible iE200-F1 (5 308 759) p. 4
Closing key
iE200-B1, part number 5 308 760 p. 4

What this sheet walks you through

  • Choosing a version by solenoid voltage and NC/NO contacts p. 3
  • Ordering actuators and the closing key p. 4

Good to know

  • Safety and alert contacts on the coil and actuator tell a released guard from one that has been released and opened. p. 1

Questions this sheet answers

How does the SICK i200 Lock unlock?

The actuator is held by a mechanical lock and is released by applying voltage to the solenoid. p. 3

What solenoid voltages does the i200 Lock come in?

24 V DC, 110 V AC and 230 V AC, each -15 to +10%. p. 3

What is the holding force of the i200 Lock?

2000 N with threaded M5 metal bolts, or 1500 N with locating pins. p. 2

What actuators fit the i200 Lock?

The straight actuator iE200-S1 (5 308 758) and the flexible actuator iE200-F1 (5 308 759). p. 4

The file

Size and text

Pages4
PDF349 KB
TextText from the PDF itself.

Every page · 4

Read it here

Each page as it is printed, and its words beside it, so a phone can search and copy them.

Page 1 of Sick i200 Spec Sheet

The text of page 1, from the PDF itself

Pgs 302-3358/10/046:06 PMPage 312i200 Lock

Safety interlocks i200 Lock

The i200 series safety interlocks with

Thanks to the fiberglass reinforced

guard lock are designed to prevent the

thermoplastic housing and to the

operator from opening the guard before

stainless steel head, this safety

the machine hazard motion has

interlock performs better than standard

stopped. The i200 series has been

limit stops with locks made of metal.

designed with a mechanical lock that

Due to the availability of 3-way insertion

can be released by applying voltage to

for the actuator and to the 180° head

the electrical coil.

rotation capability, this interlock is suitable

312SAFETY CATALOG 2004forawiderangeof

The high retention force (2000 N) and

applications. A coil status LED indicator

the availability of safety and alert

and the availability of 3-way auxiliary

contacts associated with the coil and

release allow the operator to program

the actuator, allow to it to distinguish a

and view all the interlock operating

guard that has been released from one

conditions associated with the machine

that has been released and opened.

operating modes.

Page 2 of Sick i200 Spec Sheet

The text of page 2, from the PDF itself

Pgs 302-3358/10/046:06 PMPage 313i200 Lock Drawings

Technical specifications

Approach speed (max.) Retaining force in locked condition Maximum force against which unlocking is possible Contact elements positively guided NC/NO contacts Rated insulation voltage Utilization category to IEC 60 947-5-1 Switching power (max.) Switching voltage (min.) Switching current (min.) at 5 V DC Short-circuit protection Solenoid operating voltage Power consumption, typical LED Weight Certifications

i200 Lock glass-reinforced plastic IP 65 106 switching operations -20…60° C optional 3 X M 20 160 mm/s 160 mm (80 mm flexible actuator) 1500 N (when using locating pins) 2000 N (for threaded M5 metal bolts) 100 N 3/2 or 4/1 Vi = 250 V =˜ AC 15/AC: 2 A (250V), 5 A (100 V) 250 V / 500 VA 5V 5 mA 6 A (slow), positively guided 24 V DC/Ac, 110 V AC, 230 V AC 7W illuminated with solenoid is active 0.4 Kg CE, cULus, TÜV

Locking Devices Plastic Housing

Housing material Environmental protection to IEC 60 529 Mechanical service life Ambient temperature Mounting position Connection type

SAFETY CATALOG 2004

313

Page 3 of Sick i200 Spec Sheet

The text of page 3, from the PDF itself

Pgs 302-3358/10/046:06 PMPage 314

i200 Lock Switching elements actuator inserted

inserted unblocked

disengaged open

OPERATING VOLTAGE OF THE SOLENOID 24 V DC -15…+10%

110 V AC -15…+10% 230 V AC -15…+10%

LED The safety device is able to open, the solenoid is activated.

Locking method i 200 Lock M...: mechanically locked actuator, extractable by applying voltage.

Product selection table Model i200 i200 i200 i200 i200 i200 -

Block typeSolenoid voltageM M M M M M

24 V DC 110 V AC 230 V AC 0 0 1 1 2 2

Contacts NC 3 4 3 4 3 4

NO 2 1 2 1 2 1

We recommend contacting Customer Service for product selection.

314

SAFETY CATALOG 2004

Connection M20 3 3 3 3 3 3

Part number 6 025 113 6 025 115 6 025 117 6 025 119 6 025 121 6 025 123

Page 4 of Sick i200 Spec Sheet

The text of page 4, from the PDF itself

Pgs 302-3358/10/046:06 PMPage 315

i200 Lock Accessories Closing key iE200-B1 Part number 5 308 760

Actuator flexible iE200-F1 Part number 5 308 759

Locking Devices Plastic Housing

Actuator straight iE200-S1 Part number 5 308 758

SAFETY CATALOG 2004