Spec sheet · Sick
DS 60 Distance Sensor Technical Description
Spec sheet12 pagesPDF 568 KB
Technical description of the SICK DS 60 time-of-flight distance sensor family: variants, applications, dimensions and technical data.
Covers · 1 model
The models it covers
Summary
What is in it
A technical description of the SICK DS 60 distance sensors, which measure by time of flight and switch two outputs when taught-in distances are reached. It presents the four variants (distance to object with infrared or red light, object between sensor and background, and distance to Diamond Grade reflective tape), each with application examples, dimension drawings, connection diagrams for the 5-pin M 12 plug and tables of technical data such as scanning distances, supply voltage, outputs and enclosure rating.
From the sheet · read page by page
Key facts from this sheet
Each line names its page in the PDF.
The SICK technical description from 2002 for the DS 60 time-of-flight distance sensor in four variants: DtO IR, DtO R, ObSB IR and DtR IR. It explains what each variant is for, with application examples, then gives dimension drawings, setting options, technical data, part numbers and connector and mounting accessories.
- Device
- Compact distance sensor using time of flight measurement, with two switching outputs p. 2
- Variants
- DtO IR (distance to object, infrared), DtO R (distance to object, red light), ObSB IR (object between sensor and background), DtR IR (distance to Diamond Grade reflective tape) p. 2, 3
- Scanning distance
- DtO and ObSB variants: 200 to 6000 mm; DtR IR: 80 to 20 000 mm on Diamond Grade tape p. 4, 6, 8, 10
- Power
- 18 to 30 V DC; under 3 W without load p. 5
- Switching outputs
- Q1 and Q2, invertable, 100 mA; DS 60-P: PNP, DS 60-N: NPN p. 5
- Connector
- M 12 plug, 5-pin p. 4, 5
- Light source
- DtO IR, ObSB IR and DtR IR: infrared laser diode; DtO R: red laser diode p. 5, 7, 9, 11
- Temperature
- Operation -25 to +50 °C; storage -25 to +75 °C p. 5
- Weight
- 202 g p. 5
- Setup
- Teach-in of the switching distances, two function LEDs, red pilot light for alignment (DtO R aligns by its red laser) p. 4, 6
- DtO IR part numbers
- DS 60-P21111: 1 016 361; DS 60-P21311: 1 016 393; DS 60-P41111: 1 016 687; DS 60-P41311: 1 016 689; DS 60-N21111: 1 016 394; DS 60-N21311: 1 016 686; DS 60-N41111: 1 016 688; DS 60-N41311: 1 016 690; DS 60-P41111-S03: 1 023 745 p. 5
- DtO R part numbers
- DS 60-P21211: 1 016 396; DS 60-N21211: 1 016 491; DS 60-P41211: 1 016 691; DS 60-N41211: 1 016 692 p. 7
- DtR IR part numbers
- DS 60-P11121: 1 016 397; DS 60-N11121: 1 016 492 p. 11
- Accessories
- M 12 5-pin female connectors DOS-1205-G (straight, 6 009 719) and DOS-1205-W (right angle, 6 009 720); DOL-1205 cables in 2 m, 5 m and 10 m; mounting bracket BEF-WN-DS60 (4 032 937) p. 12
What this sheet walks you through
- Measuring the distance to an object, such as a coil's diameter p. 2
- Detecting small objects, cavities or holes with the red light version p. 3
- Detecting objects between the sensor and a stationary background p. 3
- Setting crane and conveyor distances in three sectors on reflective tape p. 3
- Mounting dimensions and setting controls p. 4
- Scanning distance diagrams by object remission p. 5
- Connectors, cables, mounting bracket and weather hood p. 12
Good to know
- Do not bend the cable below 0 °C. p. 5
- Connector cables in dynamic use need a bend radius of at least 20 times the cable diameter. p. 12
- The reflective tape version switches on distance, not on an interrupted light path like a photoelectric switch. p. 2
- The sheet states laser protection class 1 for the infrared versions and class 2 for the DtO R. p. 5, 7
- The sheet states an IP 67 enclosure rating. p. 5
Questions this sheet answers
What voltage does the SICK DS60 need?
18 to 30 V DC; it draws under 3 W without load. p. 5
What is the difference between the DS 60-P and DS 60-N?
The DS 60-P has PNP switching outputs and the DS 60-N has NPN outputs. p. 5
How far can the DS60 measure?
200 to 6000 mm to an object; the DtR IR version reaches 80 to 20 000 mm on Diamond Grade reflective tape. p. 4, 10
What is the part number of the DS 60-P21111?
1 016 361. p. 5
The whole text · 2 parts
Read the sheet here as text
Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.
The file