Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a spec sheet · part 2 of 2

DS 60 Distance Sensor Technical Description, pages 7 to 12

Pages 7 to 12 of 12

The original document is the PDF (568 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Sick DS60

Page 7

TB_DS60_en.QXP 27.07.2002 13:57 Uhr Seite 7

DS 60 DtO R Technical data

DS 60

Type of connection Scanning distance, adjustable Object with 3 % remission

Weight

M 12 plug, 5-pin 200 mm to 6000 mm 80 mm to 1400 mm 80 mm to 1600 mm 80 mm to 2400 mm 80 mm to 2600 mm 80 mm to 4600 mm 80 mm to 5000 mm 80 mm to 6000 mm Laser diode, red Ø 9 mm 18 to 30 V DC <3W ≤ 5 VPP Q1, Q2 HIGH = VS – (< 2 V)/LOW = 0 V HIGH = VS /LOW ≤ 2 V 100 mA 50/s 10/s adjustable (Teach-in) on request N.C. /External Teach on request II 2 (EN 60 825-1) IP 67 Operation – 25 to + 50 °C Storage – 25 to + 75 °C 202 g

1)

4)

Object with 6 % remission Object with 18 % remission Object with 90 % remission 1) Light source 2) Light spot at 4.5 m distance Supply voltage VS 3) Power consumption 4) Ripple 5) Switching outputs (invertable) DS 60-P: PNP DS 60-N: NPN Output current 6) Switching frequency Switching limit Q1 /Q2 Time delay Multifunction MF VDE protection class 7) Laser protection class Enclosure rating Ambient temperature8)

2) 3)

Also shiny Average service life 50 000 h, at room temperature = + 25 °C Limit values, reverse polarity protected

5) 6)

Without load Must be within VS tolerances Outputs Q1 and Q2 short-circuit protected

-P -N -P -N 21211 21211 41211 41211

7) 8)

Withstand voltage 50 V DC Do not distort cable below 0 °C

Scanning distance 24

Ordering information Type Part no.

24

50/s

10/s

% of Scanning Distance

16

6% / 90%

20

12 8 4

16

18% / 90%

90% / 90%

0 (mm)1000 2000 3000 4000 5000 6000 7000

% of Scanning Distance

20

6% / 90% 18% / 90%

DS 60-P21211

1 016 396

DS 60-N21211

1 016 491

DS 60-P41211

1 016 691

DS 60-N41211

1 016 692

12 8 4

90% / 90%

0 (mm)1000 2000 3000 4000 5000 6000 7000

8 008 598 · © SICK AG · Industrial Sensors · Germany · All rights reserved

7

Page 8

TB_DS60_en.QXP 27.07.2002 13:57 Uhr Seite 8

DS 60 ObSB IR Distance Sensor: Time Flight Object between Sensor and Background, Infrared Light Dimension illustration

4

54 28

1

4

5.5 2 81.5 14

1

1

5.5

93

3 62.9 47.2

Detection of extremely dark and shiny objects against a background High target dynamic: black … extremely shiny Two function LED Red Pilot Light Teach-in

87

38

Distance Sensor

104

Scanning Distance 200 to 6000 mm

42 69

5

12

99 Setting options DS 60-P/-N31111

1 2 3 4 5 6

DS 60-P/-N31311 DS 60-P/-N51111 DS 60-P/-N51311

Q2 Q2

Run

Q1 Q1

Align

6

Teach

Connection type DS 60-P/-N31111

DS 60-P/-N51111

DS 60-P/-N31311

DS 60-P/-N51311

5-pin, M 12

8 brn

1 blk

4 blu

3 wht

2 gra

5

L+ Q1 M Q2 MF: N.C.

© SICK AG · Industrial Sensors · Germany · All rights reserved · 8 008 598

Mounting hole Ø 5.2 mm Optical axis – sender Optical axis – receiver Status indicator M 12 plug, 5-pin Control panel

Page 9

TB_DS60_en.QXP 27.07.2002 13:57 Uhr Seite 9

DS 60 ObSB IR Technical data

DS 60

Type of connection Scanning distance, adjustable Object with 3 % remission

Weight

M 12 plug, 5-pin 200 mm to 6000 mm 80 mm to 1400 mm 80 mm to 1600 mm 80 mm to 2400 mm 80 mm to 2600 mm 80 mm to 4600 mm 80 mm to 5000 mm 80 mm to 6000 mm Laser diode, infrared / Laser diode, red light on request Ø 60 mm Ø 12 mm 18 to 30 V DC <3W ≤ 5 VPP Q1, Q2 HIGH = VS – (< 2 V)/LOW = 0 V HIGH = VS /LOW ≤ 2 V 100 mA 50/s 10/s adjustable (Teach-in) on request N.C. /External Teach on request II 1 (EN 60 825-1) IP 67 Operation – 25 to + 50 °C Storage – 25 to + 75 °C 202 g

1)

4)

Object with 6 % remission Object with 18 % remission Object with 90 % remission 1) Light source 2) Light spot at 6 m distance Supply voltage VS 3) Power consumption 4) Ripple 5) Switching outputs (invertable) DS 60-P: PNP DS 60-N: NPN Output current 6) Switching frequency Switching limit Q1 /Q2 Time delay Multifunction MF VDE protection class 7) Laser protection class Enclosure rating Ambient temperature8)

2) 3)

Also shiny Average service life 100 000 h, at room temperature = + 25 °C Limit values, reverse polarity protected

5) 6)

Without load Must be within VS tolerances Outputs Q1 and Q2 short-circuit protected

-P -N -P -N -P -N -P -N 31111 31111 31311 31311 51111 51111 51311 51311

7) 8)

Withstand voltage 50 V DC Do not distort cable below 0 °C

Scanning distance 24

Ordering information Type Part no.

24

50/s

10/s 20

20

6% / 90%

6% / 90% 16

12 18% / 90% 8 4

90% / 90%

0 (mm)1000 2000 3000 4000 5000 6000 7000

% of Scanning Distance

% of Scanning Distance

16

18% / 90% 12 8 4

90% / 90%

DS 60-P31111

1 016 493

DS 60-P31311

1 016 693

DS 60-P51111

1 016 695

DS 60-P51311

1 016 697

DS 60-N31111

1 016 494

DS 60-N31311

1 016 694

DS 60-N51111

1 016 696

DS 60-N51311

1 016 698

0 (mm)1000 2000 3000 4000 5000 6000 7000

8 008 598 · © SICK AG · Industrial Sensors · Germany · All rights reserved

9

Page 10

TB_DS60_en.QXP 27.07.2002 13:57 Uhr Seite 10

DS 60 DtR IR Distance Sensor: Time Flight Measurement Distance to Reflective Tape, Infrared Light Dimension illustration

4

54 28

1

4

5.5 2 81.5 14

1

1

5.5

93

3 62.9 47.2

Distance to reflective tape diamond grade Two switching outputs Two function LED Red Pilot Light Teach-in setup of switching outputs according to the distance of reflective tape

87

38

Distance Sensor

104

Scanning Range 80 to 20 000 mm

42 69

5

12

99 Setting options DS 60-P/-N11121

Q2 Q2

Run

1 2 3 4 5 6

Q1 Q1

Align

6

Teach

Connection type DS 60-P/-N11121

5-pin, M 12

10 brn

1 blk

4 blu

3 wht

2 gra

5

L+ Q1 M Q2 MF

© SICK AG · Industrial Sensors · Germany · All rights reserved · 8 008 598

Mounting hole Ø 5.2 mm Optical axis – sender Optical axis – receiver Status indicator M 12 plug, 5-pin Control panel

Page 11

TB_DS60_en.QXP 27.07.2002 13:57 Uhr Seite 11

DS 60 DtR IR Technical data

Type of connection Scanning range, adjustable Reflective tape Light source 1) Light spot at 20 000 mm distance Supply voltage VS 2) Power consumption 3) Ripple 4) Switching outputs (invertable) DS 60-P: PNP DS 60-N: NPN Output current 5) Switching frequency Switching limit Q1 /Q2 Time delay Multifunction MF Sender on

DS 60

Weight

M 12 plug, 5-pin 80 mm to 20 000 mm Diamond Grade Laser diode, infrared Ø 200 mm 18 to 30 V DC <3W ≤ 5 VPP Q1, Q2 HIGH = VS – (< 2 V)/LOW = 0 V HIGH = VS /LOW ≤ 2 V 100 mA 50/s adjustable (Teach-in) on request Test-input /External Teach on request < 2 V or open-circuit VS – (< 2 V) or open-circuit > 12 V to < VS 0 V to VS – (> 12 V) II 1 (EN 60 825-1) IP 67 Operation – 25 to + 50 °C Storage – 25 to + 75 °C 202 g

1)

3)

Sender off VDE protection class 6) Laser protection class Enclosure rating Ambient temperature7)

2)

Average service life 100 000 h, at room temperature = + 25 °C Limit values, reverse polarity protected

4)

Without load Must be within VS tolerances

-P -N 11121 11121

5) 6)

Outputs Q1 and Q2 short-circuit protected Withstand voltage 50 V DC

7)

Do not distort cable below 0 °C

Ordering information Type Part no. DS 60-P11121

1 016 397

DS 60-N11121

1 016 492

8 008 598 · © SICK AG · Industrial Sensors · Germany · All rights reserved

11

Page 12

TB_DS60_en.QXP 31.07.2002 14:58 Uhr Seite 12

Accessories Dimensional drawings and order information Pin assignments Pin 1 = brown Pin 2 = white Pin 3 = blue Pin 4 = black Pin 5 = grey

Contact assignments according to EN 50044 DC coding

Female connector M 12, 5-pin, straight Part no. Contacts Type 6 009 719 5 DOS-1205-G

5 4

2

1

Female connector M 12, 5-pin, right angle Type Part no. Contacts DOS-1205-W 6 009 720 5 ° 45

M12x1

20

Cable diameter 4 to 6 mm

20

3

27.5

37.5

52.5

35

Cable diameter 4 to 6 mm

M12x1

Female connector M 12, 5-pin, straight Cable Ø 5/6 mm, 5 x 0.25 mm2, sheath PVC Type DOL-1205-G02M DOL-1205-G05M DOL-1205-G10M

Part no. 6 008 899 6 009 868 6 010 544

42

Type DOL-1205-W02M DOL-1205-W05M DOL-1205-W10M

Cable length 2m 5m 10 m

Part no. 6 008 900 6 009 869 6 010 542

3/blu

1/brn

4/blk 5/gra

3/blu

4/blk

2/wht

5/gra

M12x1

1/brn

26.5

1.5 M12x1

1)

Minimum bend radius in dynamic use Rmin = 20 x cable diameter

Minimum bend radius in dynamic use Rmin = 20 x cable diameter

Type BEF-WN-DS60

Part no. 4 032 937

Part no.* 1 018 470 57

3

114.6

140.5

6

135

62.3

81.5

4 0°

40°

ø6

Type WSG1-01

156

202

20°

Optical axis

D

X

50 30

7

6

41

3 22.2

ø6

*

Mounting materials included

Great Britain Erwin Sick Ltd. Waldkirch House 39 Hedley Road, St. Albans Hertfordshire AL 1 5BN +44 17 27-83 11 21 ☎ Fax +44 17 27-85 67 67 info@sick.co.uk USA SICK, Inc. 6900 West 110th Street Bloomington, MN 55438 ☎ +1 (952) 9 41-67 80 Fax +1 (952) 9 41-92 87 WATS: 1-800-325-7425 info@sickusa.com

Weather hood housing

126.5

Mounting bracket

45°

8 008 598/30-07-02 · GO/SM · Printed in Germany (08.02) · We reserve the right to make changes

Cable length 2m 5m 10 m

14.5

2/wht

Rmin1)

1)

Contacts 5 5 5

38.3

Rmin1)

1.5

14.5

Contacts 5 5 5

Female connector M 12, 5-pin, right angle Cable Ø 5/6 mm, 5 x 0.25 mm2, sheath PVC

65

Australia Sick Pty. Ltd. Head Office P.O. Box 214 899 Heidelberg Road Ivanhoe, Vic. 3079, Australia ☎ +61 39 49 74 10 0 (0 08) 33 48 02 - toll free Fax +61 39 49 71 18 7 sales@sick.com.au