Spec sheet · Sick
Mid range distance sensors Dx60, DS60: DS60-N21311 Online Data Sheet
Spec sheet6 pagesPDF 820 KB
Online data sheet for the SICK DS60-N21311 (part 1016686) mid range laser distance sensor with two NPN switching outputs.
Covers · 1 model
The models it covers
Summary
What is in it
SICK's online data sheet for the DS60-N21311 (part no. 1016686), a mid range distance sensor from the Dx60 family that uses time-of-flight measurement. It lists the main features and benefits, performance data (measuring range by target remission, response time, switching frequency, laser class, light spot size), the two NPN switching outputs, supply voltage, power, connector and weight, ambient ratings, and gives the dimensional drawing, connection diagram and sensing distance chart.
From the sheet · read page by page
Key facts from this sheet
Some pages are scans or cannot be read; this says only what the readable text supports. Each line names its page in the PDF.
A SICK online data sheet from 2013 for the DS60-N21311, a mid range distance sensor of the Dx60/DS60 family with part no. 1016686. It lists the features, performance, interface, electrical, mechanical and ambient data; its dimensional and connection drawings carry no readable text.
- Device
- DS60-N21311: mid range time-of-flight distance sensor with two switching outputs and teach-in p. 2
- Power
- DC 18 V to 30 V; 3 W or less without load p. 3
- Connector
- M12, 5-pin p. 3
- Measuring range
- 80 mm to 6,000 mm at 90 % remission, to 4,600 mm at 18 %, to 2,400 mm at 6 %; teach-in from 200 to 6,000 mm p. 2
- Temperature
- Operation -25 to 55 °C; storage -25 to 75 °C p. 3
- Switching outputs
- DS60-N21311: 2 NPN outputs, max. 100 mA, invertible, short-circuit protected p. 2, 3
- Part number
- DS60-N21311: 1016686 p. 2
- Light source
- DS60-N21311: infrared laser; light spot 12 mm x 12 mm at 6 m p. 2
- Response
- 10 ms response time; 50 Hz switching frequency p. 2
- Background suppression
- Suppresses any object in the background up to 100 m p. 2
- Weight
- 202 g p. 3
- Service life
- 50,000 h p. 2
What this sheet walks you through
- Setting the switching distance with one-button teach-in p. 2
- Measuring on an object, on a reflector or with foreground suppression p. 2
Good to know
- Operate the sensor from a short-circuit protected supply network, max. 8 A. p. 3
- The sheet states laser protection class 1 (EN 60825-1). p. 2
- The sheet states an IP 67 enclosure rating. p. 3
Questions this sheet answers
What is the part number of the SICK DS60-N21311?
1016686. p. 2
What is the measuring range of the DS60-N21311?
80 mm to 6,000 mm on a target with 90 % remission, less on darker targets (2,400 mm at 6 %). p. 2
What outputs does the DS60-N21311 have?
Two NPN switching outputs, max. 100 mA each. p. 2
What voltage does the DS60-N21311 need?
DC 18 V to 30 V, drawing 3 W or less without load. p. 3
The whole text · 1 part
Read the sheet here as text
Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.
The file