The text of a manual · part 8 of 22
CLV 43x / 44x Bar Code Scanner Operating Instructions: 6 Operation, pages 59 to 67
Pages 59 to 67 of 194, from CLV 43x / 44x Bar Code Scanner Operating Instructions
The original document is the PDF (5.7 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Sick CLV430, Sick CLV431, Sick CLV432, Sick CLV442 and Sick CLV440
Page 59
Operating instructions
Operation
Chapter 6
CLV 43x/44x Bar Code Scanner
6
Operation 6.1
Overview of the startup procedure
•
Starting up the CLV with the factory default setting (Quick Start). With this configuration, the CLV can be operated without being connected to a PC (exception: the first time the Raster scanner is switched on)
•
Connecting the PC (see Chapter 5.5.6 "Connecting the PC", Page 5-6) and install the "CLV Setup" program (see Chapter 10.4 "Installation and operating instructions for the PC-based "CLV Setup" program", Page 10-26)
•
Configuring (parameterizing) the CLV for the desired application
6.2
Default setting
Table 6-1, Page 6-2 and Table 6-2, Page 6-3 contain an overview of the factory default setting for the CLV. The default parameters are such that the CLV can be put into operation either straight away or following a few minor adjustments. A PC is not required for startup with the default setting (exception: the first time the Raster scanner is switched on). The default setting is stored permanently both in the ROM and in the CLV Setup database. They can be loaded into the RAM of the CLV or displayed on the tabs of CLV Setup at any time. Displaying and printing out complete default settings in CLV Setup 1.
To save the current settings in the parameter set, choose FILE and SAVE AS, and enter a file name in the dialog box that appears. CLV Setup saves the current settings in a configuration file "*.scl".
2.
Click in the toolbar. CLV Setup loads the default setting from its internal database and displays them on the tabs.
3.
Click in the toolbar. The PRINT FILE dialog box is then displayed.
4.
If desired, a comment can be entered in the input field for the header of the printout. Confirm the dialog box with "OK". The PRINT dialog box for configuring the printer is then displayed.
5.
Edit the dialog box accordingly and confirm.
CLV Setup prints out all of the default setting in the form of a table. The header contains the company and user names that were entered during the CLV Setup installation routine.
8 008 568/K949/10-06-2002
© SICK AG · Division Auto Ident · Germany · All rights reserved
6-1
Page 60
Chapter 6
Operation
Operating instructions CLV 43x/44x Bar Code Scanner
6.2.1
Default settings: CLV 43x/44x Line/Raster Scanner
Parameter
Default setting
Decoder
SMART decoder
Active codes types
Code 39, 2/5 Interleaved, Code 128
Code length
Freely assignable (2/5 Interleaved: interval 4 to 50 characters)
Segmentation
Start/stop ratio, automatic
Min./max. code position
0/100 CP
Multiple read
3
Min./max. no. codes
1
Scanning frequency
700 Hz
Resolution (min. bar width)
0.35 mm
Min. reading distance
DC 1: 60 mm, DC 2: 100 mm, DC 3: 200 mm, DC 4 to DC 8: 200 mm
Focus control (CLV 44x)
8 distance configurations
Focus positions
DC 1: 140 mm, DC 2: 215 mm, DC 3: 280 mm, DC 4 to DC 8: 280 mm
Trigger
"Sensor 2" switching input/serial interface
Reading pulse source
Start: "Sensor 1" switching input (active: high); end: "Sensor 1" switching input
"Sensor 2" switching input
Dynamic focus control
"Sensor 1" switching input
Start and end of reading pulse (level: active high), debouncing 20 to 30 ms
Switching outputs
Not inverted; pulse duration: 100 ms
Status output function
Result 1: "Device Ready" (static), Result 2: "Good Read"
Beeper
Status output function: Good Read, Volume "Low"
Arrangement to host
Standalone
Output of the reading result
Host interface
Device number
1
Host interface (type)
RS 422/485
Protocol
NAK ; start character: STX, stop character: ETX
Transfer rate
9 600 bit/s
Data format
8 data bits, no parity, 1 stop bit
Output format
Header: blank; separator: blank; terminator: blank; error string: NOREAD + separator
Output sorting
In accordance with code position
Output time
Reading result: end of reading pulse
Test string
Not activated
Terminal interface Function separator: after code
RS 232, 9 600 bit/s, 8 data bits, no parity, 1 stop bit (values cannot be changed) Reading diagnosis
Table 6-1: Extract: default parameter setting of the CLV 43x/44x Line/Raster Scanner
6-2
© SICK AG · Division Auto Ident · Germany · All rights reserved
8 008 568/K949/10-06-2002
Page 61
Operating instructions
Operation
Chapter 6
CLV 43x/44x Bar Code Scanner
6.2.2
Default setting of the Line scanner with oscillating mirror CLV 43x/440
Default setting as for CLV 43x/44x Line/Raster Scanner, with the following additional parameters: Parameter
Default setting
Oscillating amplitude
± 40 CW (corresponds to an angle of deflection of –20° to + 20°)
Operating mode
Oscillating with fixed amplitude
Oscillating frequency
1 Hz
Fixed position
50 CW (corresponds to an angle of deflection of 105°)
Table 6-2: Extract: default parameter settings of the Line scanner with oscillating mirror CLV 43x/440
6.3
Quick start
A PC need not be connected when the CLV is operated with the factory default setting (exception: the first time the Raster scanner is switched on, see Chapter 6.3.2 "Starting up the Raster scanner for the first time with the factory default setting", Page 6-4). 6.3.1
Starting up the Line scanner/Line scanner with oscillating mirror with the factory default setting
1.
Connect the CLV to the SICK AMV/S 40 Connection Module.
2.
Connect the reading pulse sensor (e.g. photoelectric reflex switch) to the "Sensor 1" switching input of the CLV via the AMV/S 40 (see Chapter 5.5.7 "Connecting the "Sensor 1" switching input", Page 5-7).
3.
Switch on the power supply to the AMV/S 40. Once the CLV has started, it outputs an acoustic signal to indicate that the self-test was successfully completed. Shortly afterwards, it outputs two acoustic signals to indicate that it has assumed Reading mode. The "Device Ready" LED lights up. The "Result 1" ("Device Ready") output switches. Line scanner with oscillating mirror: In the Reading mode, the CLV deflects (by default) the scan line about the position CW = 50 at a frequency of 1 Hz and a maximum angle of ±20°. 50 CW corresponds to an angle of deflection of 105°.
4.
Start the reading pulse: block the light path of the photoelectric switch or close the switch. The "Laser On" LED lights up. The CLV switches the laser diode on and the scan line appears.
5.
Present the bar code pattern from Fig. 6-1, Page 6-4 to the CLV at the reading distance specified in Table 6-3.
6.
Align the bar code in such a way that the red scan line is almost at a 90° angle to the bars (Line scanner) or that the red scan line sweeps the bars at a 90 angle when it is deflected (oscillating mirror).
7.
End the reading pulse: unblock the light path of the photoelectric switch or open the switch. The "Laser On" LED is extinguished. The CLV switches off the laser diode. The CLV confirms that the bar code was read successfully by outputting a tone via the beeper. The "Result" LED lights up for duration of 100 ms. The "Result 2" (Good Read) output switches for the duration of 100 ms.
The CLV can now be operated with the factory default setting. The device can be switched off without the configuration data being lost as no changes have been made to the parameter set.
8 008 568/K949/10-06-2002
© SICK AG · Division Auto Ident · Germany · All rights reserved
6-3
Page 62
Chapter 6
Operation
Operating instructions CLV 43x/44x Bar Code Scanner
0
Fig. 6-1:
1
2
3
4
1
2
3
4
5
Bar code sample (code 39; module width 0.35 mm; print ratio 2:1)
Device types
Scan procedure
Reading distance
CLV 430/431
Line/Raster scanner approx. 300 mm
CLV 430
Line scanner with oscillating mirror approx. 300 mm
CLV 431
Line/Raster scanner with 105° angle attachment approx. 250 mm
CLV 431
Line scanner with oscillating mirror approx. 250 mm
CLV 432
Line/Raster scanner approx. 150 mm
CLV 432
Line/Raster scanner with 105° angle attachment approx. 150 mm
CLV 432
Line scanner with oscillating mirror approx. 150 mm
CLV 440
Line scanner approx. 150 mm (DC 1)
CLV 440
Line scanner with oscillating mirror approx. 120 mm (DC 1)
CLV 442
Line scanner approx. 110 mm (DC 1)
Table 6-3: Reading distances for resolution of 0.35 mm (default setting)
6.3.2
Starting up the Raster scanner for the first time with the factory default setting
The Raster scanner also uses the SMART decoder when operated with the factory default setting. Since CLV Setup cannot distinguish between Line scanners and Raster scanners, the decoder type for the Reading mode must be set to the standard decoder manually when the Raster scanner is used. A PC with the "CLV Setup" program must be connected for this purpose.
6-4
1.
Connect the CLV to the SICK AMV/S 40 Connection Module.
2.
Connect the reading pulse sensor (e.g. photoelectric reflex switch) to the "Sensor 1" switching input of the CLV via the AMV/S 40 (see Chapter 5.5.7 "Connecting the "Sensor 1" switching input", Page 5-7).
3.
Switch on the power supply to the AMV/S 40. Once the CLV has started, it outputs an acoustic signal to indicate that the self-test was successfully completed. Shortly afterwards, it outputs two acoustic signals to indicate that it has assumed Reading mode. The "Device Ready" LED lights up. The "Result 1" ("Device Ready") output switches.
4.
Connect the PC to the terminal interface of the CLV. For this purpose, connect the RS 232 data connection cable to the internal 9-pin "Service" plug of the module (see Chapter 5.5.6 "Connecting the PC", Page 5-6).
5.
Start Windows and "CLV Setup" on your PC (see Chapter 10.4.3 "Starting "CLV Setup"", Page 10-29). In its default setting, CLV Setup attempts to communicate with the CLV via COM 1. If the communication parameters are identical, CLV Setup copies the current parameter set of the CLV from its RAM via upload into the internal database and shows the values on the tabs (at first start up, the default setting of the parameter values is in effect).
© SICK AG · Division Auto Ident · Germany · All rights reserved
8 008 568/K949/10-06-2002
Page 63
Operating instructions
Operation
Chapter 6
CLV 43x/44x Bar Code Scanner
If necessary, choose "CLV 43x" in the "Device" drop-down list in the top right-hand corner in order to initiate communication and the upload manually. 6.
Select the CODE CONFIGURATION tab.
7.
In the DECODER group, click the STANDARD radio button.
8.
Perform a download to the CLV. This is done by clicking The DOWNLOAD PARAMETER dialog box is displayed.
9.
Confirm the dialog box by selecting the PERMANENT save option. The CLV then uses the standard decoder.
in the toolbar.
Continue the quick start from Step 4 under Chapter 6.3.1 "Starting up the Line scanner/ Line scanner with oscillating mirror with the factory default setting", Page 6-3.
6.4
Configuration (parameterizing)
The CLV is configured locally in accordance with the application at hand. The read, evaluation and output characteristics can be parameterized as required. The factory default setting or an application-specific parameter set of the CLV is in effect before changes are made. The CLV supports four different configuration methods: •
Configuration via the "CLV Setup" program and the CLV Assistant (parameter values are set via the serial interface).
•
Configuration via AutoSetup (reading and code configurations for a bar code are adapted automatically via the optical interface (reading window)). (See Chapter 6.4.4 "Configuring the CLV with AutoSetup", Page 6-15)
•
Configuration via profile bar codes (parameter values are set via the optical interface (reading window)) (See Chapter 10.5.2 "Profile programming", Page 10-37).
•
Configuration via command strings (parameter values are set via the serial interface). (See Chapter 10.6 "Configuring the CLV with command strings", Page 10-41).
In Parameter mode, the CLV only outputs a reading result with AutoSetup. 6.4.1
Configuring CLV with the user interface of CLV Setup
To use the "CLV Setup" software, a PC must be connected and the software must be installed on it. The procedure for connecting the PC to the CLV is described in Chapter 5.5.6 "Connecting the PC", Page 5-6. Installation and startup of "CLV Setup" and operation of the user interface are described in the appendix (see Chapter 10.4 "Installation and operating instructions for the PC-based "CLV Setup" program", Page 10-26). Transferring parameter sets between CLV Setup and the CLV When the CLV is being parameterized, CLV Setup runs in Offline mode. To be able to modify the current parameter set of the CLV, it must first be loaded to CLV Setup from the CLV. This procedure is referred to as an Upload ("Upload from CLV"). Here, CLV Setup always loads a complete copy of the current CLV parameter set. This remains there, unchanged, until overwritten by CLV Setup. Using the context menu (right mouse button), only the parameter which was just edited is loaded from the memory (RAM) of the CLV ("Upload Parameter"). Changes made to the current parameter set in CLV Setup do not take effect until the parameter set has been transferred to the CLV. CLV Setup always loads a complete copy of the entire parameter set to the CLV, i.e. all previous parameter values in the CLV are overwritten. The procedure for transferring and saving the parameter values in the CLV is
8 008 568/K949/10-06-2002
© SICK AG · Division Auto Ident · Germany · All rights reserved
6-5
Page 64
Chapter 6
Operation
Operating instructions CLV 43x/44x Bar Code Scanner referred to as a Download ("Download to CLV"). Using the context menu (right mouse button), only the parameter which was just edited is loaded temporarily into memory (RAM) of the CLV ("Download Parameter"). Loading the complete parameter set from the CLV (Upload)
¾ Click in the toolbar. CLV Setup loads the current CLV parameter set from the RAM of the CLV to its database and displays the values on the tabs. The "Device Ready" LED is extinguished during the upload.
If the CLV Setup program does not recognize the parameters transferred during the upload, it outputs a warning message. Unknown parameters can be edited on the EXTRAS tab by following the conventions for command strings. When the parameter set is saved, these parameters are also taken into account. Transferring the complete parameter set to the CLV and saving it (Download) 1.
2.
Click in the toolbar. The "Device Ready" LED is extinguished. CLV Setup copies the parameter set to the RAM of the CLV. The DOWNLOAD PARAMETERS dialog box with the save options is then displayed. PERMANENT:
CLV Setup copies the parameter set to the RAM and to the EEPROM of the CLV.
TEMPORARY:
CLV Setup copies the parameter set to the RAM only. The changes are lost when the CLV power supply is switched off.
Confirm the dialog box with the desired save option.
The "Device Ready" LED lights up again. The new parameter set is saved in the CLV. Saving the parameter set in CLV Setup 1.
To save the modified parameter set as a new configuration file in CLV Setup or to overwrite an existing file, select the menu FILE and the menu item SAVE AS. The CLV FILE SELECTOR dialog box is then displayed.
2.
Enter the file name in the dialog box (file extension "*.scl") and confirm the entry.
The new parameter set is now saved in CLV Setup in the subdirectory "data".
6-6
© SICK AG · Division Auto Ident · Germany · All rights reserved
8 008 568/K949/10-06-2002
Page 65
Operating instructions
Operation
Chapter 6
CLV 43x/44x Bar Code Scanner
6.4.2
Function of tabs in CLV Setup (overview)
Reading Configuration This tab (and additional dialog boxes) are used to set the following: •
Scanning frequency and module width
•
CLV 43x: distance configuration (min. reading distance, evaluation range of the scan line, deflection range of the oscillating mirror, assignment table)
•
CLV 44x: focus control (min. reading distance, focus position, evaluation range of the scan line, deflection range of the oscillating mirror, assignment table)
•
Trigger source for the distance configuration switchover (CLV 43x) or dynamic focus control function (CLV 44x)
•
Start/stop ratio
•
Adapting the reading function to the quality of the bar code
Device Configuration This tab (and additional dialog boxes) are used to set the following: •
Device number
•
Source of the reading pulse
•
Output time of the reading result referred to the start of the reading pulse
•
Spatial parameters
•
Output filter
•
Laser timeout
•
Physical arrangement for data output via the host interface (standalone, master/slave)
•
Functional assignment of the "Sensor 2" switching input
•
Functional assignments of the "Result 1" and "Result 2" switching outputs
•
Functional assignment and volume of the beeper
•
Mode for programming match code 1 (teach-in) via the "Sensor 2" switching input
•
Code comparison
Code Configuration This tab (and additional dialog boxes) are used to set the following:
Recommendation
8 008 568/K949/10-06-2002
•
Type of active decoder (SMART and/or standard decoder)
•
Activation of evaluation routines for individual code types
•
Number of identical reads (multiple reads)
•
Minimum and maximum number of bar codes to be read/output
•
Activation of comparison of code position for the separation of identical bar codes
To enhance the reading reliability with fast applications, only activate those code types and code lengths that are actually relevant.
© SICK AG · Division Auto Ident · Germany · All rights reserved
6-7
Page 66
Operation
Chapter 6
Operating instructions CLV 43x/44x Bar Code Scanner
Host Interface This tab (and additional dialog boxes) are used to set the following: •
Destination of result output
•
Active physical interface (RS 422/485 or RS 232)
•
Data format and transfer rate
•
Data transfer protocol
•
Start and stop characters of the interface protocol
Data Strings This tab (and additional dialog boxes) are used to set the following: •
Data output format of the host interface
•
Constants and reading diagnosis data in the header, separator and terminator
•
Arrangement of the separators in the data string
•
Output format for no reads and contents of the error string
•
Test string function
•
Output sequence and sort criteria for reading more than one bar code per reading pulse
•
Activation and structure of format mask
Auxiliary Interface This tab is used to set the following: •
Operating mode of the terminal interface
CAN Interface This tab (and additional dialog boxes) are used to set the following: •
Operating mode of the CAN interface
•
Data transmission rate
•
Type of logical data network of connected CLVs
•
Use of switching inputs/outputs of the CLV as CANopen Digital I/O
Oscillating Mirror This tab is used to set the following: •
Operating mode of the oscillating mirror
•
Oscillating frequency
•
Angle of deflection (oscillating amplitude)
•
Start of Oscillating mode based on the reading pulse
•
Trigger source for one-shot
Extras This tab is used to edit parameters that were not recognized by CLV Setup after an upload. Note
6-8
The online "CLV Setup Help" contains a detailed description of the functions of the parameters and their valid entries (for calling up help, see Chapter 10.4.6 "“CLV Setup Help“ online help", Page 10-32).
© SICK AG · Division Auto Ident · Germany · All rights reserved
8 008 568/K949/10-06-2002
Page 67
Operation
Operating instructions
Chapter 6
CLV 43x/44x Bar Code Scanner
6.4.3
Parameterization guide
Overview of parameterization procedure •
Parameterizing optical reading characteristics of the scanner
•
Setting up reading pulse
•
Parameterizing the evaluation characteristics of the decoder
•
Parameterizing the output characteristics (data, result status)
•
Setting the function of the terminal interface (auxiliary interface)
When the CLV is started up for the first time, the factory default setting is in effect. In this case, the following parameters are to be set: a) Parameterizing optical reading characteristics • • • •
Ö READING CONFIGURATION tab Ö Module width Scanning frequency Ö READING CONFIGURATION tab Ö Reading parameters Rest zone Ö READING CONFIGURATION tab Ö Segmentation Poor quality bar code print Ö READING CONFIGURATION tab Ö Codelabel quality Module width
Setting up switchover of the distance configuration (CLV 43x) or the focus position (CLV 44x) Action
Line/Raster scanner
1. Activate switchover of the distance configuration/focus position (choose trigger source)
2. Choose switchover/focus point (based on reading pulse)
Ö READINg Configuration tab Ö FOCUS TRIGGER SOURCE
Ö READING Configuration tab Ö FOCUS TRIGGER SOURCE
Ö
Ö
– Inputs/Serial or – Timer TIMER or – Static/No Trigger
FOCUS TRIGGER SOURCE
Ö Inputs/Serial
– Immediate or Synchronous – Latched
3. Set up distance DISTANCE CONFIGURATION/ASSIGNMENT TABLE configurations/focus positions Distance configuration – Minimum Distance – Focus Position (CLV 44x only) – Minimum Code Position CP – Maximum Code Position CP Assignment Table – Index – Valid Configurations
Ö Ö
4. In trigger mode "Inputs/ Serial": Choose function for switching input "Sensor 2"
Line scanner with oscillating mirror
Ö DEVICE Configuration tab Ö ASSIGNMENT SENSOR 2
– Dynamic focus control
– Inputs/Serial or – Timer TIMER or – Static/No Trigger or – Oscillating Mirror Reversal Points
FOCUS TRIGGER SOURCE
Ö Inputs/Serial
– Immediate or Synchronous – Latched
DISTANCE CONFIGURATION/ASSIGNMENT TABLE
Ö Distance configuration
Ö
– Minimum Distance – Focus Position (CLV 44x only) – Minimum Code Position CP – Maximum Code Position CP – Oscillating Mirror Amplitude CW Assignment Table – Index – Valid Configurations
Ö DEVICE Configuration tab Ö ASSIGNMENT SENSOR 2
– Dynamic focus control
Table 6-4: Guide: parameterizing switchover of the distance configuration/focus position
Note
8 008 568/K949/10-06-2002
The minimum and maximum values for the active evaluation range of the scan line (MIN. AND MAX. CODE POSITION) can be checked in the "Show CP-limits" mode (see Chapter 6.5.4 "Show CP-limits", Page 6-25).
© SICK AG · Division Auto Ident · Germany · All rights reserved
6-9