Page 49
Operating instructions
Electrical installation
Chapter 5
CLV 43x/44x Bar Code Scanner
5
Electrical installation 5.1
Overview of the installation sequence
•
Connecting the CLV to the SICK AMV/S 40 Connection Module
•
Adapting the connection of the host interface in the module to the host interface of the CLV
•
Connecting the data and function interfaces of the CLV in the module
•
Connecting the PC to the Connection Module (at the terminal interface on the CLV)
•
Connecting the power supply to the connection module
5.2
Electrical connections and cables
The electrical connection for the CLV consists of a 15-pin D-Sub HD plug. It supplies the following interfaces: •
Three serial data interfaces (host interface, CAN interface and terminal interface)
•
Two switching inputs (external reading pulse and multifunctional input)
•
Two switching outputs (for result status function, or connecting to a PLC for example)
•
Power supply
¾ All of the connections must be wired with copper cables with a minimum wire diameter of 0.09 mm2! 5.2.1
Connections/cables for the AMV/S 40 Connection Module
The AMV/S 40 Connection Module is suitable for connecting the CLV to peripherals (distribution function) and the power supply. The module can be used to establish a connection to the host (point-to-point) or integrate the device in a SICK network or daisychain configuration (pass-through or master/slave configuration). Fig. 5-1 shows the connection principle of the AMV/S 40 for one CLV. CLV 43x/44x
AMV/AMS 40 Connection Module Photoelectric switch Reading pulse
" "
" "
Photoelectric switch Dynamic focus control (CLV 44x) One-shot trigger Path increment Teach-in match code 1
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
"
HOST/PLC
"
PLC
10 to 30 V DC (AMV 40-011) 230 V AC (AMS 40-013) 115 V AC (AMS 40-012)
– – cable if necessary Fig. 5-1:
Block diagram: connection of the CLV to the AMV/S 40 Connection Module
8 008 568/K949/10-06-2002
© SICK AG · Division Auto Ident · Germany · All rights reserved
5-1
Page 50
Chapter 5
Electrical installation
Operating instructions CLV 43x/44x Bar Code Scanner
For connecting and configuring the AMV/S 40 Connection Module, see the Operating Instructions for the "AMV/S 40 Connection Module" (order no. 8 008 292, English edition).
5.3
Connector pin assignment
Pin
Signal
Function
1
+10 to +30 V DC
Power supply
2
RxD (Terminal)
Terminal interface (receiver)
3
TxD (Terminal)
Terminal interface (transmitter)
4
Sensor 2
Switching input, variable function
5
GND
Ground
6
RD+ (RS 422/485)
Host interface (receiver)
7
RD– (RS 422/485); RxD (RS 232)
Host interface (receiver)
8
TD+ (RS 422/485)
Host interface (transmitter)
9
TD– (RS-422/485); TxD (RS-232)
Host interface (transmitter)
10
CAN H
CAN bus (IN/OUT)
11
CAN L
CAN bus (IN/OUT)
12
Result 1
Switching output, variable function
13
Result 2
Switching output, variable function
14
Sensor 1
Switching input for external reading pulse
15
SensGND
Common ground for all inputs
–
–
Shield
Table 5-1: Pin assignment of the 15-pin D-Sub HD plug
5.4
Preparations for electrical connection
5.4.1
Requirements for the host interface
The host interface of the CLV can be operated as an RS 422/485 or an RS 232 interface. Table 5-2 shows the recommended maximum cable lengths as a function of the selected data transfer rate. Interface type
Transmission rate
Distance from host
RS 232
Up to 19 200 bit/s 38 400 to 57 600 bit/s
Max. 10 m Max. 3 m
RS 422/4851)
Max. 38 400 bit/s Max. 57 600 bit/s
Max. 1 200 m Max. 500 m
1) with suitable line termination
Table 5-2: Maximum cable lengths between the CLV and host
¾ To prevent interference, do not lay the cable parallel with power supply and motor cables over long distances, e.g. in cable ducts.
5-2
© SICK AG · Division Auto Ident · Germany · All rights reserved
8 008 568/K949/10-06-2002
Page 51
Electrical installation
Operating instructions
Chapter 5
CLV 43x/44x Bar Code Scanner
5.4.2
Power supply
The CLV requires a power supply of 10 to 30 V DC in accordance with IEC 742 (functional extra-low voltage) for operation. The power consumption varies depending on the device type: CLV type
Scan procedure
Power consumption1)
CLV 43x
Line/Raster scanner
Max. 4 W
CLV 43x
Line scanner with oscillating mirror
Max. 6.15 W
CLV 44x
Line scanner
Max. 5 W
CLV 440
Line scanner with oscillating mirror
Max. 6.15 W
1) switching outputs not connected
Table 5-3: Power consumption of the CLV
The CLV is supplied with 24 V DC ±20 % via the AMS Connection Module 40-013, -012. Power-up delay The selected device number (default setting: 1) affects the power-up delay of the device. This is useful if a large number of CLVs (e.g. in the SICK network) are to be supplied from one power source. Table 5-4 contains a list of the available intervals. Device number GN
Device number GN
Power-up delay
0 ms
6; 16; 26
2 000 ms
400 ms
7; 17; 27
2 400 ms
3; 13; 23
800 ms
8; 18; 28
2 800 ms
4; 14; 24
1 200 ms
9; 19; 29
3 200 ms
5; 15; 25
1 600 ms
10; 20; 30
3 600 ms
1; 11; 21; 31 2; 12; 22
Power-up delay
Table 5-4: Power-up delay as a function of the device number GN
Tip
The device number can be selected on the DEVICE CONFIGURATION tab in the CLV Setup program. 5.4.3
Non-SICK power supply unit/connections without the SICK connection module
If a non-SICK power pack is used instead of the AMV/S 40, it must provide a continuous power output of 10 W and comply with IEC 742 (functional extra-low voltage). The output circuit must be reliably electrically isolated from the input circuit pursuant to IEC 742 by means of double insulation and a safety isolating transformer. The wire cross-section for the power supply (pin 1/pin 5) must be at least 0.15 mm2.
¾ Use the cable no. 6 010 137 with 15-pin D-Sub HD socket and open end to connect the CLV. The color assignment of the wires is shown in Table 5-5.
8 008 568/K949/10-06-2002
© SICK AG · Division Auto Ident · Germany · All rights reserved
5-3
Page 52
Chapter 5
Electrical installation
Operating instructions CLV 43x/44x Bar Code Scanner
Pin
Signal
Wiring color
1
+10 to +30 V DC
Red
2
RxD (Terminal)
Purple
3
TxD (Terminal)
Yellow
4
Sensor 2
Red/black
5
GND
Black
6
RD+ (RS 422/485)
Light blue
7
RD– (RS 422/485); RxD (RS 232)
Blue
8
TD+ (RS 422/485)
Turquoise
9
TD– (RS 422/485); TxD (RS 232)
Green
10
CAN H
Gray
11
CAN L
Pink
12
Result 1
Brown
13
Result 2
Orange
14
Sensor 1
White
15
SensGND
White/black
–
Shield
White/green
Table 5-5: Wiring color assignment of cable no. 6 010 137 (open end)
5.5
Performing electrical installation
5.5.1
Overview of connection procedure
•
Connecting the power supply
•
Connecting the host interface
•
Connecting the PC (connect the terminal interface)
•
Connecting the "Sensor 1" and "Sensor 2" switching inputs
•
Connecting the "Result 1" and "Result 2" switching outputs
5.5.2
Tools
•
Tool
•
Digital measuring device (current/voltage measurement)
5.5.3
Connecting the power supply
If the CLV is powered via the AMV/S 40 Connection Module, the power supply does not have to be wired separately. 1.
Ensure that the power supply to the AMV/S 40 is switched off.
2.
Connect the 15-pin plug on the CLV to the corresponding socket on the AMV/S 40 and screw it tightly. The connecting cable can be extended by 2 m using the extension cable no. 6 010 075.
The data and functional interfaces of the CLV are connected to the connection module. – or – External power supply unit:
¾ Connect the power supply to the red wire (pin 1, +10 to +30 V DC) and the black wire (pin 5, GND) of cable no. 6 010 137 (see also Table 5-5).
5-4
© SICK AG · Division Auto Ident · Germany · All rights reserved
8 008 568/K949/10-06-2002
Page 53
Operating instructions
Electrical installation
Chapter 5
CLV 43x/44x Bar Code Scanner
5.5.4
Connecting the host interface Terminal assignment AMV 40-011/AMS 40-012, -013:
RS 232
CLV
Host ( )= 9-pin D-Sub plug on the PC
RS 422
CLV RS 485: Fig. 5-2:
Host
Connection diagram for SICK network available upon request
Connections of the host interface
Risk of damage to the interface module! Electrical components in the CLV may be damaged if the host interface is connected incorrectly. This also applies when the host interface connections are changed in the AMV/S 40 Connection Module (configuration).
¾ Connect the host interface as shown in Fig. 5-2. ¾ Check the connections carefully before you switch on the CLV.
Recommendation
1.
Connect the host interface on the CLV to the host using shielded cables (EMC requirements). Ensure that the maximum cable lengths are not exceeded (Table 5-2, Page 5-2).
2.
Apply the shielding at one end.
In the default setting, the CLV communicates with the host via the host interface using the values shown in Table 5-6. Parameter
Value
Interface model
RS 422/485
Data transmission rate
9 600 bit/s
Data bits
8
Parity none
Stop bits
1
Protocol
SICK (start character: STX, stop character: ETX, no request for repeat: none, timeout: 50 ms)
Table 5-6: Communication parameters for the host interface (default setting)
8 008 568/K949/10-06-2002
© SICK AG · Division Auto Ident · Germany · All rights reserved
5-5
Page 54
Electrical installation
Chapter 5
Operating instructions CLV 43x/44x Bar Code Scanner
For connecting the host interface via the AMV/S 40 Connection Module, see the Operating Instructions for the "AMV/S 40 Connection Module" (order no. 8 008 292, English edition) Terminating the RS 422 interface The interface can be terminated in the AMV/S 40 Connection Module. See Operating Instructions for the "AMV/S 40 Connection Module". Connecting to a CL 20 mA interface The optional interface converter no. 2 020 825 can be installed in the AMV/S 40 Connection Module to connect the RS 422 interface to a CL 20 mA interface. The connection procedure is described in the Operating Instructions for the "AMV/S 40 Connection Module". Activating the RS 232 interface The RS 232 interface can be activated with the CLV Setup program: 1.
Select the HOST INTERFACE tab.
2.
Choose the "RS 232" option from the HARDWARE drop-down list under DATA FORMAT.
3.
Perform a download to the CLV. This is done by clicking The DOWNLOAD PARAMETER dialog box is displayed.
4.
Confirm the dialog box by selecting the PERMANENT save option.
in the toolbar.
The CLV uses the RS 232 version of the host interface. Tip
The communication parameters can be changed, if necessary, on the HOST INTERFACE tab. To do so, change the values under DATA FORMAT and INTERFACE PROTOCOL. 5.5.5
CAN interface
For information on the connection and parameterization of the CLV for use in a SICK scanner network or in a CANopen network, see the Operating Instructions "Alpplication of the CAN interface" (no. 8 009 180, English edition). 5.5.6
Connecting the PC
The CLV is operated and configured with the PC-based "CLV Setup" program. In order to do so, you must connect the device to the PC via the terminal interface (auxiliary interface). Unlike the host interface, the terminal interface has a permanent data format and a fixed data transfer rate. Fig. 5-3 shows how the terminal interface is connected. The cable length is not to exceed 10 m. Terminal assignment AMV 40-011/AMS 40-012, -013:
RS 232 PC CLV ( )= 9-pin D-Sub plug on the PC Fig. 5-3:
5-6 or 9-pin plug "Service"
Connections of the terminal interface
© SICK AG · Division Auto Ident · Germany · All rights reserved
8 008 568/K949/10-06-2002
Page 55
Electrical installation
Operating instructions
Chapter 5
CLV 43x/44x Bar Code Scanner
1.
Switch off the PC and power supply to the SICK connection module.
2.
Connect the PC to the internal, 9-pin "Service" plug of the connection module. Use an RS 232 data connection cable for this purpose, e.g. no. 2 014 054 (RxD and TxD crossed). – or – if no SICK Connection module is used: Connect the PC as shown in Fig. 5-3.
Tip
3.
Switch on the PC and power supply to the SICK connection module.
4.
Set the communication parameters (see Chapter 10.4.3 "Starting "CLV Setup"", Page 10-29).
In the default setting, the terminal interface outputs the reading result in "Reading Diagnosis" mode. You can change the operating mode to "Monitor Host Interface" or "Auxiliary Input" on the AUX. INTERFACE tab in the CLV Setup program. 5.5.7
Connecting the "Sensor 1" switching input
If a reading procedure is to be triggered on the CLV by an external sensor, the reading pulse sensor must be connected to the "Sensor 1" switching input. The trigger type is selected in the default setting of the CLV. Fig. 5-4 shows the connections for the "Sensor 1" switching input. Table 5-7 contains the characteristic data for this input.
¾ Connect the reading pulse sensor as shown in Fig. 5-4. CLV 43x/44x
VS
PNP sensor
Switch
Terminal assignment AMV 40-011/AMS 40-012, -013: VS /+24 V
T. 18 VS
VS
SENSOR*)
T. 14
SGND GND
VS= +10 to +30 V DC Fig. 5-4:
T. 15 T. 17
*) Vimax= 28 V!
Connections of the "Sensor 1" switching input Switching mode
Current at the input starts the reading interval on the CLV. (default setting: active high, debouncing: max. 30 ms (standard))
Properties
– optodecoupled, non-interchangeable – can be connected to PNP output on a sensor
Electrical values
Low: –1V ≤ Vi ≤ +1 V –0.3 mA ≤ Ii ≤ +0.3 mA
High: +3 V ≤ |Vi| ≤ +28 V +1.4 mA ≤ |Ii| ≤ +18 mA
Table 5-7: Characteristic data of the "Sensor 1" switching input
Tip
You can change the switching mode (polarity, debouncing, response for first pulse after power-up) of the "Sensor 1" switching input on the DEVICE CONFIGURATION tab in the CLV Setup program.
¾ Click the EDIT READING TRIGGER button. Edit dialog box.
8 008 568/K949/10-06-2002
© SICK AG · Division Auto Ident · Germany · All rights reserved
5-7
Page 56
Electrical installation
Chapter 5
Operating instructions CLV 43x/44x Bar Code Scanner
For connecting the switching input via the AMV/S 40 Connection Module, see the Operating Instructions for the "AMV/S 40 Connection Module" (order no. 8 008 292, English edition). Note
An external pulse is not required for "Percentage Evaluation" mode. 5.5.8
Connecting the "Sensor 2" switching input
If the dynamic focus control function of the CLV 44x is to be triggered by an external sensor, the sensor must be connected at the "Sensor 2" input. In conjunction with the internal assignment table, this causes the changeover between 2 distance configurations (from a max. of 8 configurations). The input also has the following functions for all CLVs: •
Trigger source for teaching in the match code 1
•
Conveyor increment input
•
Trigger source for one-shot function of the oscillating mirror
The "dynamic focus control" function is selected by default. The characteristic data is identical to that for the "Sensor 1" input (Table 5-7). Fig. 5-5 shows the connection of the switching input. Table 5-8 contains the input combinations with regard to the distance configurations.
¾ Connect the sensors as shown in Fig. 5-5. CLV 43x/44x
VS
PNP sensor
Switch
VS
VS
Terminal assignment AMV 40-011/AMS 40-012, -013: VS /+24 V Sensor 2*)
T. 4
SGND GND
VS= +10 to +30 V DC Fig. 5-5:
*) Vimax= 28 V!
Connections of the "Sensor 2" switching input
For connecting the switching input via the AMV/S 40 Connection Module, see the Operating Instructions for the "AMV/S 40 Connection Module" (order no. 8 008 292, English edition).
5-8
© SICK AG · Division Auto Ident · Germany · All rights reserved
8 008 568/K949/10-06-2002
Page 57
Operating instructions
Electrical installation
Chapter 5
CLV 43x/44x Bar Code Scanner
Switching input Logical state of "Sensor 2" input
Content Assignment Table Distance Config.1) Allocation table index
Default setting
Example: Photoelectric switches (bright switching)
0
0
DC 1
DC 2
1
1
DC 2
DC 3
2
DC 3
DC 3
3
DC 4
DC 4
4
DC 5
DC 5
5
DC 6
DC 6
6
DC 7
DC 7
7
DC 8
DC 8
1) Distance configuration (DC): data record for focus position
Table 5-8: Dynamic focus control: switching input/distance configuration assignment table
The function assigned to the "Sensor 2" input can be modified on the DEVICE CONFIGURATION tab in the CLV Setup program.
¾ Click the FUNCTION SENSOR 2 drop-down list and choose the desired function.
The connections and procedure for teaching in match code 1 are described in Chapter 10.9.1 "Triggering the Teach-in match code 1 via the "Sensor 2" switching input", Page 10-48. 5.5.9
Connecting the "Result 1" and "Result 2" switching outputs
The two switching outputs can be assigned different functions for outputting result statuses independently of each other. If the assigned event occurs during the reading procedure, the corresponding switching output becomes live at the end of the reading pulse for the selected pulse duration. The pulse duration is identical for both outputs. The "Result" LED is linked to the "Result 2" output and lights up in "Reading" mode for the selected pulse duration and function of the result status display (default setting: "Good Read", 100 ms). Fig. 5-6 shows an example of how the "Result 1" switching output can be connected. Table 5-9 describes the characteristic data for the outputs. This data is identical for both outputs.
8 008 568/K949/10-06-2002
© SICK AG · Division Auto Ident · Germany · All rights reserved
5-9
Page 58
Electrical installation
Chapter 5
Operating instructions CLV 43x/44x Bar Code Scanner
¾ Connect the outputs as shown in Fig. 5-6. Terminal assignment AMV 40-011/AMS 40-012, -013:
CLV 43x/44x
VS "Result 1" a
Structure of output Result 2 (pin 13) same as output Result 1
VS= +10 to +30 V DC Fig. 5-6:
Pulse duration based on setting: – 10 ms to 990 ms – 00: Static (to the end of the next reading pulse)
Connection of the "Result 1" switching output
For connecting the switching outputs via the AMV/S 40 Connection Module, see the Operating Instructions for the "AMV/S 40 Connection Module" (order no. 8 008 292, English edition). Switching mode
PNP-switching with respect to the power supply VS
Characteristics
Short-circuit-proof + temperature protected, not electrically isolated from VS
Function assignment (default setting)
Result 1: "Device Ready (static)", polarity: not inverted Result 2: "Good Read", polarity: not inverted Pulse duration: 100 ms
Electrical values
(VS − 1.5 V) ≤ Vo ≤ VS at Io ≤ 100 mA
Table 5-9: Characteristic data of the "Result 1" and "Result 2" switching outputs
Note
If the "Device Ready" function is chosen, the CLV outputs a static pulse in Reading mode.
Tip
The output function, pulse duration (timer) and polarity of the signals can be changed on the DEVICE CONFIGURATION tab in the CLV Setup program.
¾ Click the EDIT RESULT OUTPUTS button. Edit dialog box.
Recommendation
¾ To check the switching functions using a high-impedance digital voltmeter, power the outputs to prevent incorrect voltage statuses from being displayed. This prevents incorrect voltage values/switching statuses from being displayed.
5-10