Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 7 of 22

CLV 43x / 44x Bar Code Scanner Operating Instructions: 5 Electrical installation

Pages 49 to 58 of 194, from CLV 43x / 44x Bar Code Scanner Operating Instructions

The original document is the PDF (5.7 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Sick CLV430, Sick CLV431, Sick CLV432, Sick CLV442 and Sick CLV440

Page 49

Operating instructions

Electrical installation

Chapter 5

CLV 43x/44x Bar Code Scanner

5

Electrical installation 5.1

Overview of the installation sequence

•

Connecting the CLV to the SICK AMV/S 40 Connection Module

•

Adapting the connection of the host interface in the module to the host interface of the CLV

•

Connecting the data and function interfaces of the CLV in the module

•

Connecting the PC to the Connection Module (at the terminal interface on the CLV)

•

Connecting the power supply to the connection module

5.2

Electrical connections and cables

The electrical connection for the CLV consists of a 15-pin D-Sub HD plug. It supplies the following interfaces: •

Three serial data interfaces (host interface, CAN interface and terminal interface)

•

Two switching inputs (external reading pulse and multifunctional input)

•

Two switching outputs (for result status function, or connecting to a PLC for example)

•

Power supply

¾ All of the connections must be wired with copper cables with a minimum wire diameter of 0.09 mm2! 5.2.1

Connections/cables for the AMV/S 40 Connection Module

The AMV/S 40 Connection Module is suitable for connecting the CLV to peripherals (distribution function) and the power supply. The module can be used to establish a connection to the host (point-to-point) or integrate the device in a SICK network or daisychain configuration (pass-through or master/slave configuration). Fig. 5-1 shows the connection principle of the AMV/S 40 for one CLV. CLV 43x/44x

AMV/AMS 40 Connection Module Photoelectric switch Reading pulse

" "

" "

Photoelectric switch Dynamic focus control (CLV 44x) One-shot trigger Path increment Teach-in match code 1

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

"

HOST/PLC

"

PLC

10 to 30 V DC (AMV 40-011) 230 V AC (AMS 40-013) 115 V AC (AMS 40-012)

– – cable if necessary Fig. 5-1:

Block diagram: connection of the CLV to the AMV/S 40 Connection Module

8 008 568/K949/10-06-2002

© SICK AG · Division Auto Ident · Germany · All rights reserved

5-1

Page 50

Chapter 5

Electrical installation

Operating instructions CLV 43x/44x Bar Code Scanner

For connecting and configuring the AMV/S 40 Connection Module, see the Operating Instructions for the "AMV/S 40 Connection Module" (order no. 8 008 292, English edition).

5.3

Connector pin assignment

Pin

Signal

Function

1

+10 to +30 V DC

Power supply

2

RxD (Terminal)

Terminal interface (receiver)

3

TxD (Terminal)

Terminal interface (transmitter)

4

Sensor 2

Switching input, variable function

5

GND

Ground

6

RD+ (RS 422/485)

Host interface (receiver)

7

RD– (RS 422/485); RxD (RS 232)

Host interface (receiver)

8

TD+ (RS 422/485)

Host interface (transmitter)

9

TD– (RS-422/485); TxD (RS-232)

Host interface (transmitter)

10

CAN H

CAN bus (IN/OUT)

11

CAN L

CAN bus (IN/OUT)

12

Result 1

Switching output, variable function

13

Result 2

Switching output, variable function

14

Sensor 1

Switching input for external reading pulse

15

SensGND

Common ground for all inputs

–

–

Shield

Table 5-1: Pin assignment of the 15-pin D-Sub HD plug

5.4

Preparations for electrical connection

5.4.1

Requirements for the host interface

The host interface of the CLV can be operated as an RS 422/485 or an RS 232 interface. Table 5-2 shows the recommended maximum cable lengths as a function of the selected data transfer rate. Interface type

Transmission rate

Distance from host

RS 232

Up to 19 200 bit/s 38 400 to 57 600 bit/s

Max. 10 m Max. 3 m

RS 422/4851)

Max. 38 400 bit/s Max. 57 600 bit/s

Max. 1 200 m Max. 500 m

1) with suitable line termination

Table 5-2: Maximum cable lengths between the CLV and host

¾ To prevent interference, do not lay the cable parallel with power supply and motor cables over long distances, e.g. in cable ducts.

5-2

© SICK AG · Division Auto Ident · Germany · All rights reserved

8 008 568/K949/10-06-2002

Page 51

Electrical installation

Operating instructions

Chapter 5

CLV 43x/44x Bar Code Scanner

5.4.2

Power supply

The CLV requires a power supply of 10 to 30 V DC in accordance with IEC 742 (functional extra-low voltage) for operation. The power consumption varies depending on the device type: CLV type

Scan procedure

Power consumption1)

CLV 43x

Line/Raster scanner

Max. 4 W

CLV 43x

Line scanner with oscillating mirror

Max. 6.15 W

CLV 44x

Line scanner

Max. 5 W

CLV 440

Line scanner with oscillating mirror

Max. 6.15 W

1) switching outputs not connected

Table 5-3: Power consumption of the CLV

The CLV is supplied with 24 V DC ±20 % via the AMS Connection Module 40-013, -012. Power-up delay The selected device number (default setting: 1) affects the power-up delay of the device. This is useful if a large number of CLVs (e.g. in the SICK network) are to be supplied from one power source. Table 5-4 contains a list of the available intervals. Device number GN

Device number GN

Power-up delay

0 ms

6; 16; 26

2 000 ms

400 ms

7; 17; 27

2 400 ms

3; 13; 23

800 ms

8; 18; 28

2 800 ms

4; 14; 24

1 200 ms

9; 19; 29

3 200 ms

5; 15; 25

1 600 ms

10; 20; 30

3 600 ms

1; 11; 21; 31 2; 12; 22

Power-up delay

Table 5-4: Power-up delay as a function of the device number GN

Tip

The device number can be selected on the DEVICE CONFIGURATION tab in the CLV Setup program. 5.4.3

Non-SICK power supply unit/connections without the SICK connection module

If a non-SICK power pack is used instead of the AMV/S 40, it must provide a continuous power output of 10 W and comply with IEC 742 (functional extra-low voltage). The output circuit must be reliably electrically isolated from the input circuit pursuant to IEC 742 by means of double insulation and a safety isolating transformer. The wire cross-section for the power supply (pin 1/pin 5) must be at least 0.15 mm2.

¾ Use the cable no. 6 010 137 with 15-pin D-Sub HD socket and open end to connect the CLV. The color assignment of the wires is shown in Table 5-5.

8 008 568/K949/10-06-2002

© SICK AG · Division Auto Ident · Germany · All rights reserved

5-3

Page 52

Chapter 5

Electrical installation

Operating instructions CLV 43x/44x Bar Code Scanner

Pin

Signal

Wiring color

1

+10 to +30 V DC

Red

2

RxD (Terminal)

Purple

3

TxD (Terminal)

Yellow

4

Sensor 2

Red/black

5

GND

Black

6

RD+ (RS 422/485)

Light blue

7

RD– (RS 422/485); RxD (RS 232)

Blue

8

TD+ (RS 422/485)

Turquoise

9

TD– (RS 422/485); TxD (RS 232)

Green

10

CAN H

Gray

11

CAN L

Pink

12

Result 1

Brown

13

Result 2

Orange

14

Sensor 1

White

15

SensGND

White/black

–

Shield

White/green

Table 5-5: Wiring color assignment of cable no. 6 010 137 (open end)

5.5

Performing electrical installation

5.5.1

Overview of connection procedure

•

Connecting the power supply

•

Connecting the host interface

•

Connecting the PC (connect the terminal interface)

•

Connecting the "Sensor 1" and "Sensor 2" switching inputs

•

Connecting the "Result 1" and "Result 2" switching outputs

5.5.2

Tools

•

Tool

•

Digital measuring device (current/voltage measurement)

5.5.3

Connecting the power supply

If the CLV is powered via the AMV/S 40 Connection Module, the power supply does not have to be wired separately. 1.

Ensure that the power supply to the AMV/S 40 is switched off.

2.

Connect the 15-pin plug on the CLV to the corresponding socket on the AMV/S 40 and screw it tightly. The connecting cable can be extended by 2 m using the extension cable no. 6 010 075.

The data and functional interfaces of the CLV are connected to the connection module. – or – External power supply unit:

¾ Connect the power supply to the red wire (pin 1, +10 to +30 V DC) and the black wire (pin 5, GND) of cable no. 6 010 137 (see also Table 5-5).

5-4

© SICK AG · Division Auto Ident · Germany · All rights reserved

8 008 568/K949/10-06-2002

Page 53

Operating instructions

Electrical installation

Chapter 5

CLV 43x/44x Bar Code Scanner

5.5.4

Connecting the host interface Terminal assignment AMV 40-011/AMS 40-012, -013:

RS 232

CLV

Host ( )= 9-pin D-Sub plug on the PC

RS 422

CLV RS 485: Fig. 5-2:

Host

Connection diagram for SICK network available upon request

Connections of the host interface

Risk of damage to the interface module! Electrical components in the CLV may be damaged if the host interface is connected incorrectly. This also applies when the host interface connections are changed in the AMV/S 40 Connection Module (configuration).

¾ Connect the host interface as shown in Fig. 5-2. ¾ Check the connections carefully before you switch on the CLV.

Recommendation

1.

Connect the host interface on the CLV to the host using shielded cables (EMC requirements). Ensure that the maximum cable lengths are not exceeded (Table 5-2, Page 5-2).

2.

Apply the shielding at one end.

In the default setting, the CLV communicates with the host via the host interface using the values shown in Table 5-6. Parameter

Value

Interface model

RS 422/485

Data transmission rate

9 600 bit/s

Data bits

8

Parity none

Stop bits

1

Protocol

SICK (start character: STX, stop character: ETX, no request for repeat: none, timeout: 50 ms)

Table 5-6: Communication parameters for the host interface (default setting)

8 008 568/K949/10-06-2002

© SICK AG · Division Auto Ident · Germany · All rights reserved

5-5

Page 54

Electrical installation

Chapter 5

Operating instructions CLV 43x/44x Bar Code Scanner

For connecting the host interface via the AMV/S 40 Connection Module, see the Operating Instructions for the "AMV/S 40 Connection Module" (order no. 8 008 292, English edition) Terminating the RS 422 interface The interface can be terminated in the AMV/S 40 Connection Module. See Operating Instructions for the "AMV/S 40 Connection Module". Connecting to a CL 20 mA interface The optional interface converter no. 2 020 825 can be installed in the AMV/S 40 Connection Module to connect the RS 422 interface to a CL 20 mA interface. The connection procedure is described in the Operating Instructions for the "AMV/S 40 Connection Module". Activating the RS 232 interface The RS 232 interface can be activated with the CLV Setup program: 1.

Select the HOST INTERFACE tab.

2.

Choose the "RS 232" option from the HARDWARE drop-down list under DATA FORMAT.

3.

Perform a download to the CLV. This is done by clicking The DOWNLOAD PARAMETER dialog box is displayed.

4.

Confirm the dialog box by selecting the PERMANENT save option.

in the toolbar.

The CLV uses the RS 232 version of the host interface. Tip

The communication parameters can be changed, if necessary, on the HOST INTERFACE tab. To do so, change the values under DATA FORMAT and INTERFACE PROTOCOL. 5.5.5

CAN interface

For information on the connection and parameterization of the CLV for use in a SICK scanner network or in a CANopen network, see the Operating Instructions "Alpplication of the CAN interface" (no. 8 009 180, English edition). 5.5.6

Connecting the PC

The CLV is operated and configured with the PC-based "CLV Setup" program. In order to do so, you must connect the device to the PC via the terminal interface (auxiliary interface). Unlike the host interface, the terminal interface has a permanent data format and a fixed data transfer rate. Fig. 5-3 shows how the terminal interface is connected. The cable length is not to exceed 10 m. Terminal assignment AMV 40-011/AMS 40-012, -013:

RS 232 PC CLV ( )= 9-pin D-Sub plug on the PC Fig. 5-3:

5-6 or 9-pin plug "Service"

Connections of the terminal interface

© SICK AG · Division Auto Ident · Germany · All rights reserved

8 008 568/K949/10-06-2002

Page 55

Electrical installation

Operating instructions

Chapter 5

CLV 43x/44x Bar Code Scanner

1.

Switch off the PC and power supply to the SICK connection module.

2.

Connect the PC to the internal, 9-pin "Service" plug of the connection module. Use an RS 232 data connection cable for this purpose, e.g. no. 2 014 054 (RxD and TxD crossed). – or – if no SICK Connection module is used: Connect the PC as shown in Fig. 5-3.

Tip

3.

Switch on the PC and power supply to the SICK connection module.

4.

Set the communication parameters (see Chapter 10.4.3 "Starting "CLV Setup"", Page 10-29).

In the default setting, the terminal interface outputs the reading result in "Reading Diagnosis" mode. You can change the operating mode to "Monitor Host Interface" or "Auxiliary Input" on the AUX. INTERFACE tab in the CLV Setup program. 5.5.7

Connecting the "Sensor 1" switching input

If a reading procedure is to be triggered on the CLV by an external sensor, the reading pulse sensor must be connected to the "Sensor 1" switching input. The trigger type is selected in the default setting of the CLV. Fig. 5-4 shows the connections for the "Sensor 1" switching input. Table 5-7 contains the characteristic data for this input.

¾ Connect the reading pulse sensor as shown in Fig. 5-4. CLV 43x/44x

VS

PNP sensor

Switch

Terminal assignment AMV 40-011/AMS 40-012, -013: VS /+24 V

T. 18 VS

VS

SENSOR*)

T. 14

SGND GND

VS= +10 to +30 V DC Fig. 5-4:

T. 15 T. 17

*) Vimax= 28 V!

Connections of the "Sensor 1" switching input Switching mode

Current at the input starts the reading interval on the CLV. (default setting: active high, debouncing: max. 30 ms (standard))

Properties

– optodecoupled, non-interchangeable – can be connected to PNP output on a sensor

Electrical values

Low: –1V ≤ Vi ≤ +1 V –0.3 mA ≤ Ii ≤ +0.3 mA

High: +3 V ≤ |Vi| ≤ +28 V +1.4 mA ≤ |Ii| ≤ +18 mA

Table 5-7: Characteristic data of the "Sensor 1" switching input

Tip

You can change the switching mode (polarity, debouncing, response for first pulse after power-up) of the "Sensor 1" switching input on the DEVICE CONFIGURATION tab in the CLV Setup program.

¾ Click the EDIT READING TRIGGER button. Edit dialog box.

8 008 568/K949/10-06-2002

© SICK AG · Division Auto Ident · Germany · All rights reserved

5-7

Page 56

Electrical installation

Chapter 5

Operating instructions CLV 43x/44x Bar Code Scanner

For connecting the switching input via the AMV/S 40 Connection Module, see the Operating Instructions for the "AMV/S 40 Connection Module" (order no. 8 008 292, English edition). Note

An external pulse is not required for "Percentage Evaluation" mode. 5.5.8

Connecting the "Sensor 2" switching input

If the dynamic focus control function of the CLV 44x is to be triggered by an external sensor, the sensor must be connected at the "Sensor 2" input. In conjunction with the internal assignment table, this causes the changeover between 2 distance configurations (from a max. of 8 configurations). The input also has the following functions for all CLVs: •

Trigger source for teaching in the match code 1

•

Conveyor increment input

•

Trigger source for one-shot function of the oscillating mirror

The "dynamic focus control" function is selected by default. The characteristic data is identical to that for the "Sensor 1" input (Table 5-7). Fig. 5-5 shows the connection of the switching input. Table 5-8 contains the input combinations with regard to the distance configurations.

¾ Connect the sensors as shown in Fig. 5-5. CLV 43x/44x

VS

PNP sensor

Switch

VS

VS

Terminal assignment AMV 40-011/AMS 40-012, -013: VS /+24 V Sensor 2*)

T. 4

SGND GND

VS= +10 to +30 V DC Fig. 5-5:

*) Vimax= 28 V!

Connections of the "Sensor 2" switching input

For connecting the switching input via the AMV/S 40 Connection Module, see the Operating Instructions for the "AMV/S 40 Connection Module" (order no. 8 008 292, English edition).

5-8

© SICK AG · Division Auto Ident · Germany · All rights reserved

8 008 568/K949/10-06-2002

Page 57

Operating instructions

Electrical installation

Chapter 5

CLV 43x/44x Bar Code Scanner

Switching input Logical state of "Sensor 2" input

Content Assignment Table Distance Config.1) Allocation table index

Default setting

Example: Photoelectric switches (bright switching)

0

0

DC 1

DC 2

1

1

DC 2

DC 3

2

DC 3

DC 3

3

DC 4

DC 4

4

DC 5

DC 5

5

DC 6

DC 6

6

DC 7

DC 7

7

DC 8

DC 8

1) Distance configuration (DC): data record for focus position

Table 5-8: Dynamic focus control: switching input/distance configuration assignment table

The function assigned to the "Sensor 2" input can be modified on the DEVICE CONFIGURATION tab in the CLV Setup program.

¾ Click the FUNCTION SENSOR 2 drop-down list and choose the desired function.

The connections and procedure for teaching in match code 1 are described in Chapter 10.9.1 "Triggering the Teach-in match code 1 via the "Sensor 2" switching input", Page 10-48. 5.5.9

Connecting the "Result 1" and "Result 2" switching outputs

The two switching outputs can be assigned different functions for outputting result statuses independently of each other. If the assigned event occurs during the reading procedure, the corresponding switching output becomes live at the end of the reading pulse for the selected pulse duration. The pulse duration is identical for both outputs. The "Result" LED is linked to the "Result 2" output and lights up in "Reading" mode for the selected pulse duration and function of the result status display (default setting: "Good Read", 100 ms). Fig. 5-6 shows an example of how the "Result 1" switching output can be connected. Table 5-9 describes the characteristic data for the outputs. This data is identical for both outputs.

8 008 568/K949/10-06-2002

© SICK AG · Division Auto Ident · Germany · All rights reserved

5-9

Page 58

Electrical installation

Chapter 5

Operating instructions CLV 43x/44x Bar Code Scanner

¾ Connect the outputs as shown in Fig. 5-6. Terminal assignment AMV 40-011/AMS 40-012, -013:

CLV 43x/44x

VS "Result 1" a

Structure of output Result 2 (pin 13) same as output Result 1

VS= +10 to +30 V DC Fig. 5-6:

Pulse duration based on setting: – 10 ms to 990 ms – 00: Static (to the end of the next reading pulse)

Connection of the "Result 1" switching output

For connecting the switching outputs via the AMV/S 40 Connection Module, see the Operating Instructions for the "AMV/S 40 Connection Module" (order no. 8 008 292, English edition). Switching mode

PNP-switching with respect to the power supply VS

Characteristics

Short-circuit-proof + temperature protected, not electrically isolated from VS

Function assignment (default setting)

Result 1: "Device Ready (static)", polarity: not inverted Result 2: "Good Read", polarity: not inverted Pulse duration: 100 ms

Electrical values

(VS − 1.5 V) ≤ Vo ≤ VS at Io ≤ 100 mA

Table 5-9: Characteristic data of the "Result 1" and "Result 2" switching outputs

Note

If the "Device Ready" function is chosen, the CLV outputs a static pulse in Reading mode.

Tip

The output function, pulse duration (timer) and polarity of the signals can be changed on the DEVICE CONFIGURATION tab in the CLV Setup program.

¾ Click the EDIT RESULT OUTPUTS button. Edit dialog box.

Recommendation

¾ To check the switching functions using a high-impedance digital voltmeter, power the outputs to prevent incorrect voltage statuses from being displayed. This prevents incorrect voltage values/switching statuses from being displayed.

5-10

© SICK AG · Division Auto Ident · Germany · All rights reserved

8 008 568/K949/10-06-2002