CLV 43x / 44x Bar Code Scanner Operating Instructions: 3 Product description
Pages 21 to 32 of 194, from CLV 43x / 44x Bar Code Scanner Operating Instructions
The original document is the PDF (5.7 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Sick CLV430, Sick CLV431, Sick CLV432, Sick CLV442 and Sick CLV440
Page 21
Operating instructions
Product description
Chapter 3
CLV 43x/44x Bar Code Scanner
3
Product description 3.1
Design
3.1.1
Scope of delivery
The CLV is supplied with the following: •
Two polling reflectors for automatic reading pulse generation
•
An information sheet (note on device) with terminal diagram and Quick Start instructions
•
An additional set of Class 2 laser warning labels (self-adhesive) in German/US English and French/US English
Depending on the number of devices ordered, a set of technical documentation consisting of one or more copies of the following: •
These CLV 43x/44x Operating Instructions in English and German
•
A CD-ROM containing "CLV Setup" for WindowsTM, the online help system "CLV Setup Help" and the HTML browser "I-ViewProTM"
•
A fold-out card with 12 profile bar codes
Chapter 10.11 "Accessories", Page 10-59 provides an overview of the available installation accessories, connection modules, cables and plug-in connections and sensors for reading pulse generation and object distance detection (CLV 44x). 3.1.2
Variants
The CLV is available in the following variants: CLV 43x Type (red light)
Part No.
Scan procedure
Reading window
CLV 430-0010
1 017 585
Line scanner
Front
CLV 430-1010
1 016 705
Raster scanner
Front
CLV 430-6010
1 017 981
Line scanner with oscillating mirror
Side
CLV 431-0010
1 017 622
Line scanner
Front
CLV 431-1010
1 016 679
Raster scanner
Front
CLV 431-2010
1 016 746
Line scanner with 105° angle attachment
Side
CLV 431-3010
1 016 747
Raster scanner with 105° angle attachment
Side
CLV 431-6010
1 017 982
Line scanner with oscillating mirror
Side
CLV 432-0010
1 017 623
Line scanner
Front
CLV 432-1010
1 016 680
Raster scanner
Front
CLV 432-2010
1 016 748
Line scanner with 105° angle attachment
Side
CLV 432-3010
1 016 749
Raster scanner with 105° angle attachment
Side
CLV 432-6010
1 017 983
Line scanner with oscillating mirror
Side
Table 3-1: Variants of the CLV 43x
8 008 568/K949/10-06-2002
© SICK AG · Division Auto Ident · Germany · All rights reserved
3-1
Page 22
Chapter 3
Product description
Operating instructions CLV 43x/44x Bar Code Scanner
CLV 440 Type (red light)
Part No.
Scan procedure
Reading window
CLV 440-0010
1 017 588
Line scanner
Front
CLV 440-6010
1 017 984
Line scanner with oscillating mirror
Side
Table 3-2: Variants of the CLV 440
CLV 442 Type (red light)
Part No.
Scan procedure
Reading window
CLV 442-0010
1 017 595
High-density Line scanner
Front
Table 3-3: Variants of the CLV 442
3.1.3
System requirements
The following are required to start up and operate the CLV: 1.
A SICK Connection Module to provide the power supply and connect the data and functional interfaces. Available types: – AMV 40-011 (no. 1 017 132) for 24 V DC ±20 %, enclosure rating max. IP 54 – AMS 40-013 (no. 1 017 135) for 230 V AC 50 Hz/24 V DC, enclosure rating max. IP 54 – AMS 40-012 (no. 1 017 136) for 115 V AC 50/60 Hz/24 V DC, enclosure rating max. IP 54 – AMV 100-011 (no. 6 021 105) for 10 to 30 V DC, enclosure rating max. IP 65 – AMV 200-011 (no. 6 021 106) for 10 to 30 V DC, enclosure rating max. IP 65
– or – Alternatively, a non-SICK device with a voltage output of 10 to 30 V DC pursuant to IEC 742 (functional extra-low voltage) and at least 10 W power output. Cable no. 6 010 137 with 15-pin D Sub HD socket and one open end for connecting the CLV to the external power pack. 2.
The following operating voltages/power outputs – AMV 40-011: 24 V DC ±20 % (pursuant to IEC 742), at least 10 W – AMS 40-013: 230 V AC ±10 % 50 Hz – AMS 40-012: 115 V AC ±10 % 50/60 Hz – AMV 100-011: 10 to 30 V DC (pursuant to IEC 742) – AMV 200-011: 10 to 30 V DC (pursuant to IEC 742)
3-2
3.
With external clock pulse supply via the "Sensor 1" switching input: a suitable reading pulse sensor for signaling the presence of an object with a bar code, e.g. a photoelectric reflex switch.
4.
With object distance detection via the "Sensor 2" switching input (CLV 44x): a suitable sensor for two-stage dynamic focus control, e.g. photoelectric reflex switch.
5.
A higher-level computer (host) with a data interface of type RS 422/485 or RS 232.
6.
The optional interface converter no. 2 020 825 (installed in the AMV/S 40 Connection Module) for connecting the CLV to a 20 mA data interface.
7.
A PC (at least 80486, 66 MHz, 16 MB RAM, CD-ROM drive, serial interface, mouse (recommended)) with Windows 95TM/98TM, Windows NTTM or Windows XPTM.
© SICK AG · Division Auto Ident · Germany · All rights reserved
8 008 568/K949/10-06-2002
Page 23
Operating instructions
Product description
Chapter 3
CLV 43x/44x Bar Code Scanner
8.
An RS 232 data connection cable with two 9-pin D-Sub sockets for connecting the PC to the terminal interface of the CLV in the AMV/S Connection Module, e.g. no. 2 014 054. Pin 2 (RxD) and Pin 3 (TxD) are crossed.
9.
To use the online help system "CLV Setup Help", an HTML browser is required, e.g. "Netscape NavigatorTM" or the supplied "I-ViewProTM" browser (see Chapter 3.1.1 "Scope of delivery", Page 3-1).
10. For connection of the CLV to the Interbus S, the Profibus DP, the DeviceNet or Ethernet: the corresponding BMV/BMH 10 Bus Connection Module (on request). 11. For connection of the CLV to the CAN bus: the operating instructions "Using the CAN interface" (no. 8 009 180, English edition).
8 008 568/K949/10-06-2002
© SICK AG · Division Auto Ident · Germany · All rights reserved
3-3
Page 24
Product description
Chapter 3
Operating instructions CLV 43x/44x Bar Code Scanner
3.1.4
View of Line/Raster scanner devices with angle attachment
2 1
7 3 6 4
5
2 8
Key:
1 D-Sub HD plug, 15-pin 2 Tapped blind holes M 5, 5 mm deep
3 Reading window 4 Laser warning labels 5 Connection cable 6 Sound opening of the beeper (covered)
7 LEDs (status indicators) 8 Integrated angle attachment with 105° light reflection Front reading window Fig. 3-1:
3-4
Side reading window
CLV43x/44x Line/Raster scanner without/with 105° angle attachment
© SICK AG · Division Auto Ident · Germany · All rights reserved
8 008 568/K949/10-06-2002
Page 25
Product description
Operating instructions
Chapter 3
CLV 43x/44x Bar Code Scanner
3.1.5
View of Line scanner device with oscillating mirror
2 1
6 5 3
4
2
7
Key:
8
Side reading window
Fig. 3-2:
1 D-Sub HD cable plug, 15-pin 2 Tapped blind holes M 5, 5 mm deep 3 Laser warning labels 4 Connection cable 5 Sound opening of the beeper (covered) 6 LEDs (status indicators) 7 Integrated oscillating mirror 8 Reading window
CLV 43x/440 Line scanner with oscillating mirror
8 008 568/K949/10-06-2002
© SICK AG · Division Auto Ident · Germany · All rights reserved
3-5
Page 26
Chapter 3
Product description
Operating instructions CLV 43x/44x Bar Code Scanner
3.2
Method of operation
The CLV first scans the bar code with a scan line and then decodes it. The CLV directs the data to a host/PC for further processing via the main data interface (serial host interface). An overview of the CLV functions is provided in Fig. 3-3. CLV 43x/44x
PC Operation Parameterizing etc. Photoelectric switch Reading pulse
" "
Signal Dynamic focus control (CLV 44x) Teach-in match code 1, etc.
"
"
"
"
"
HOST Further processing of the reading result
"
"
"
"
"
Status indicator e.g. Good Read e.g. No Read
10 to 30 V DC
Fig. 3-3:
Block diagram: CLV functions
The CLV is equipped with two decoders: •
The SMART decoder (SICK Modular Advanced Recognition Technology) for decoding bar codes with a small aspect ratio (ratio of the code height to the code length), bar codes that are dirty or damaged, as well as bar codes that are tilted excessively (azimuth angle)
•
The tried-and-tested standard decoder of the CLV series
The CLV derives useful diagnosis data from the reading process and transfers it to the host. It also records operating data that can be interrogated at any time. The quality of the read can be checked in "Percentage Evaluation" mode. To start a reading process when an object is located in the reading field, the CLV requires a suitable trigger. This opens a time window ("reading interval") in the CLV for the reading procedure. In the default setting, this trigger is supplied by an external reading pulse sensor. Alternative trigger sources include Reflector polling, Free-Running mode or a command via the host interface. Reflector polling is only supported in "Fixed Position" mode (no oscillation) on the Line scanner with oscillating mirror. The current operating status is indicated by four LEDs. A beeper indicates the status of the reading result. In the default setting, the "GOOD READ" function is selected for this. If the trigger is supplied externally by a sensor, the "Sensor 1" switching input signals the start of the reading procedure to the CLV. The "Sensor 2" switching input is used to switch the focus position on the CLV 44x and to switch the distance configuration on the CLV 43x. Alternatively, it can be used to teach in a match code. The "Result 1" and "Result 2" switching outputs can be assigned various functions and control external devices, such as a PLC.
3-6
© SICK AG · Division Auto Ident · Germany · All rights reserved
8 008 568/K949/10-06-2002
Page 27
Operating instructions
Product description
Chapter 3
CLV 43x/44x Bar Code Scanner
The CLV is operated and configured via the auxiliary interface (terminal interface) using the "CLV Setup" software or via the host/terminal interface and command strings. System messages, warnings and error messages help you with configuration and with locating the source of errors during startup and in Reading mode. 3.2.1
Dynamic focus control
Unlike the fixed focus of the CLV 43x, the CLV 44x can switch its focus position dynamically and thus cover a large reading range. A maximum of eight reading ranges can be defined as distance configurations, each of which can be approached consecutively in Reading mode Fig. 3-4. Reading field height Focus position
Reading distance
Focus position
DC = Distance Configuration Fig. 3-4:
Reading distance
Dynamic focus control CLV 44x: classification of the reading range in distance configurations
The switch takes place in response to changes in the object distance (with reads from above: object height detection). The trigger source for the max. two-stage switchover is a signal at the "Sensor 2" switching input. The source for the max. eight-stage switchover is a command on the host interface or the integrated timer (e.g. for search mode). In the case of the Line scanner with oscillating mirror, the source can also be the oscillating mirror reversal points. The distance configurations are assigned to the switchover sequence via a programmable assignment table. In the case of the CLV 430, 431, and 432 with fixed focus, the distance configurations can also be used to restrict the active evaluation range of the scan line and to limit the angle of deflection of the oscillating mirror. In the default setting, the first three focus positions of the CLV 440 cover the reading ranges of the CLV 432 (short range), CLV 431 (mid range), and CLV 430 (long range).
8 008 568/K949/10-06-2002
© SICK AG · Division Auto Ident · Germany · All rights reserved
3-7
Page 28
Chapter 3
Product description
Operating instructions CLV 43x/44x Bar Code Scanner
3.2.2
Scan procedure variants
Line scanner Generates a scan line. Due to the V-principle of beam generation, the reading field height (for evaluating the useful length of the scan line) is dependent on the reading distance. Raster scanner Generates 8 parallel scan lines that are offset by the same distance. Due to the V-principle of beam generation, the reading field height (for evaluating the useful length of the scan lines) is dependent on the reading distance. Raster height of the scan line field: 15 mm at a reading distance of 200 mm (front reading window). Can only be used with the standard decoder! Line scanner with oscillating mirror The oscillating mirror also deflects the scan line perpendicularly to the scan direction at both sides around the neutral position with a low oscillating frequency. As a result, the CLV can also scan larger areas for bar codes. Due to the V-principle of beam generation, the reading field height (for evaluating the useful length of the scan line) is dependent on the reading distance. In addition to parking (fixed position) and simple deflection with the maximum deflection range, optimized oscillating mirror functions are also available: •
Oscillating with variable deflection range for each distance configuration
•
One-shot: one-off, defined deflection per reading pulse (forward and return phase).
Fig. 3-5 shows an example of the trigger for dynamic focus control on a stationary object using the internal timer or the oscillating mirror reversal points ("search mode") for six distance configurations. Reading pulse Focus position t t1 t2 t3 t4 t5 t6 t1 t2 t3 t4 t5 t
- or -
+jmax
Deflection angle
Fig. 3-5:
3-8
–jmax
Timer t
Oscillating mirror reversal points
Oscillating mirror of CLV 440: example of dynamic focus control in search mode
© SICK AG · Division Auto Ident · Germany · All rights reserved
8 008 568/K949/10-06-2002
Page 29
Operating instructions
Product description
Chapter 3
CLV 43x/44x Bar Code Scanner
3.3
Indicators and control elements
3.3.1
Control elements
The CLV is operated and configured via the terminal interface using the "CLV Setup" program or using command strings sent via the host interface/terminal interface. A variety of parameter options allow you to adapt the device to a wide range of applications. The following can be defined: •
The configuration of the code types to be read
•
The reading, evaluation and output characteristics
•
The communication parameters of the host interface
•
The structure of the data output string for "good read" and "no read" on the host interface
•
The function of the terminal interface
Chapter 10.4 "Installation and operating instructions for the PC-based "CLV Setup" program", Page 10-26 describes the procedure for installing the "CLV Setup" program and how to operate the user interface. Configuration (parameterizing) is explained in Chapter 6.4 "Configuration (parameterizing)", Page 6-5. 3.3.2
Function of the LEDs
Four LEDs indicate the operating status, activity of the laser diode, output of the reading result and data transfer on the host interface. The LEDs (Fig. 3-6) are located on the rear of the device. Table 3-4 shows the meaning of the LEDs in the different operating modes/ functions.
Fig. 3-6:
8 008 568/K949/10-06-2002
LEDs
© SICK AG · Division Auto Ident · Germany · All rights reserved
3-9
Page 30
Product description
Chapter 3
Operating instructions CLV 43x/44x Bar Code Scanner
Operating mode
LED
Indication
Function
Start
Device Ready
Orange
• Lights up after power-up if the self-test was successful and the wait time for reading the profile bar codes has expired
Laser On
Orange
• Lights up while the laser diode for reading the profile bar codes is active
Device Ready
Orange
• Lights up constantly
Reading mode
• Extinguishes with new operating mode/function Laser On
Orange
• Lights up if reading diode active (The laser diode is activated/deactivated by reading pulse) • Lights up constantly in "Free Running" mode, since the laser diode is always active • Lights up with every 20th scan in Reflector Polling mode. The scan line is faintly visible.
Result
Orange
LED is connected to the "Result 2" switching output. It indicates the result status for selected for the pulse duration of the output. • Lights up after a good read (default setting: "Good Read") • Illuminates if code comparison is activated, the read barcode matches the predefined match code(s) and the corresponding result status output is selected for the "Result 2" output
Percentage evaluation
Data
Orange
• Flickers while the CLV transfers data to the host on the host interface
Laser On
Orange
• Lights up constantly (Free Running mode)
Result
Orange
Behavior depends on the reading quality: • Extinguishes if reading rate < 30 % • Blinks twice a second if reading rate 30 % to 70 % • Blinks five times a second if reading rate 70 % to 90 % • Lights up constantly if reading rate > 90 %
Profile programming
Laser On
Orange
• Lights up while the profile bar codes are being read (Free Running mode)
AutoSetup
Laser On
Orange
• Lights up while the application-specific bar codes are being read (Free Running mode)
Adjusting mode
Laser On
Orange
• Lights up constantly (Free Running mode)
Show CP-limits
Laser On
Orange
• Blinks bright/dark alternately, in the frequency with which the scan line is (partially) masked out
Table 3-4: Meaning of the LEDs
3-10
© SICK AG · Division Auto Ident · Germany · All rights reserved
8 008 568/K949/10-06-2002
Page 31
Product description
Operating instructions
Chapter 3
CLV 43x/44x Bar Code Scanner
3.3.3
Function of the beeper
The beeper uses different tone sequences and lengths (Table 3-5) to signal whether functions have been executed successfully and whether any malfunctions have occurred. For information on troubleshooting, see Chapter 8.5 "Troubleshooting", Page 8-7. In the default setting, the beeper indicates the event status Good READ by means of a LOW (quiet) beep. It is assumed in these operating instructions that the beeper is operated with the default setting in Reading mode. The sound opening of the beeper is located on the rear, narrow side of the device and below the LED labeling. Operating mode
Tone sequence
Beeper function
Start
Beep
• Signals that the self-test after power-up was successful
Reading mode
Beep Beep
• Confirms that the device has assumed Reading mode after power up and that the wait time of 5 s for reading the profile bar codes has elapsed
Beep
• Confirms a successful read (good read; default setting) and the reading result output
Beep
• Confirms successful read of profile bar code for start/end of AutoSetup
Beep Beep
• Confirms successful read of application-specific bar code and start of Reading mode
Beep (long tone)
• Signals that the application-specific bar code was not read
Beep
• Confirms successful read of profile bar code
Beep Beep
• Confirms start of Reading mode 10 s after last profile bar code was read
Beep Beep Beep
• Signals that the laser diode has been deactivated after the laser timeout of 10 min (default setting) was exceeded in Reading mode. The reading pulse is still active.
Profile programming Start AutoSetup
Profile programming
Exceeding the laser timeout
Table 3-5: Beeper function
Tip
The behavior of the beeper in Reading mode can be changed on the DEVICE CONFIGURATION tab in the CLV Setup program. Volume: Click the required field in the BEEPER group. Output function for the result status: 1.
Click the EDIT RESULT OUTPUTS button in the RESULT OUTPUT section. The EDIT RESULT OUTPUTS dialog box is displayed.
2.
Click the BEEPER list field in the RESULT FUNCTIONS section. The list containing the available result status functions appears.
3.
Click the required function and choose "OK".
4.
Perform a download to the CLV. This is done by clicking DOWNLOAD PARAMETERS dialog box is then displayed.
5.
Confirm the dialog box by selecting the PERMANENT save option.
in the toolbar. The
The CLV operates the beeper with the values selected for the result status and volume.
8 008 568/K949/10-06-2002
© SICK AG · Division Auto Ident · Germany · All rights reserved
3-11
Page 32
Product description
Chapter 3
Operating instructions CLV 43x/44x Bar Code Scanner
Notes
3-12
© SICK AG · Division Auto Ident · Germany · All rights reserved
8 008 568/K949/10-06-2002