The text of a manual · part 3 of 22
CLV 43x / 44x Bar Code Scanner Operating Instructions, pages 15 to 20
Pages 15 to 20 of 194: 1 Notes on this document; 2 Safety information
The original document is the PDF (5.7 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Sick CLV430, Sick CLV431, Sick CLV432, Sick CLV442 and Sick CLV440
Page 15
Operating instructions
Notes on this document
Chapter 1
CLV 43x/44x Bar Code Scanner
1
Notes on this document 1.1
Purpose
This document contains instructions for operating the following bar code scanners: •
CLV 430 Long Range, with fixed focus
•
CLV 431 Mid Range, with fixed focus
•
CLV 432 Short Range, with fixed focus
•
CLV 440 with dynamic focus control
•
CLV 442 High Density, with dynamic focus control in the variants •
Line scanner without/with 105° angle attachment
•
Raster scanner without/with 105° angle attachment
•
Line scanner with oscillating mirror
This document provides information on •
Installation and electrical installation
•
Startup
•
Operation and configuration (parameterizing)
•
Maintenance
•
Exchanging the device while retaining the parameter set
•
Special applications and procedures
The bar code scanners will all simply be called "CLV" below, except in such text passages where a differentiation is required.
1.2
Target audience
This document is intended for persons who are responsible for the following activities: 1.2.1
Installation, electrical installation, maintenance and replacement
Electricians and service technicians 1.2.2
Startup, operation and configuration
Technicians and engineers
1.3
Information content
This document contains all of the information required for installation, electrical installation and startup of the CLV with the factory default setting. A series of step-by-step instructions is provided for each of these activities. The CLV is configured for specific applications using the Windows-based "CLV Setup" and "CLV Assistant". Further assistance is also available in the form of the online help system "CLV Setup Help". The procedure for installing and operating the software is described in the Appendix. For further information on the design of the bar code scanner or on bar code technology in general, please contact the Auto Ident division at SICK AG.
8 008 568/K949/10-06-2002
© SICK AG · Division Auto Ident · Germany · All rights reserved
1-1
Page 16
Notes on this document
Chapter 1
Operating instructions CLV 43x/44x Bar Code Scanner
1.4
Symbols
Some of the information in this document is marked specially so that you can access it quickly: Warning! Warnings are provided to prevent injury to operating personnel or serious damage to the bar code scanner.
¾ Always read warnings carefully and observe them at all times. Note Explanation Recommendation
Notes indicate special features or characteristics. Explanations provide background information on technical correlations. Recommendations help you carry out certain procedures more effectively.
Tip
Tips explain settings in the user interface of the CLV Setup program.
Default setting
Marks a section containing the values of the factory default setting.
SCANNING FREQUENCY
This font indicates a term in the user interface of the CLV Setup program. Icons refer to buttons in the user interface of the CLV Setup program.
"Host receive fault"
This font indicates messages output via the terminal interface of the CLV. This symbol identifies sections that describe steps carried out with the user interface of the CLV Setup program.
This symbol is used to mark sections that describe steps carried out with the profile programming.
This symbol refers to additional technical documentation.
¾ Ö
1-2
An action must be performed. This symbol identifies single-step instructions. Instructions consisting of several steps are numbered consecutively. Here you select a function of the user interface of CLV Setup.
© SICK AG · Division Auto Ident · Germany · All rights reserved
8 008 568/K949/10-06-2002
Page 17
Operating instructions
Safety information
Chapter 2
CLV 43x/44x Bar Code Scanner
2
Safety information 2.1
Authorized users
For the CLV to function correctly and safely, it must be installed and operated by sufficiently qualified personnel. The following qualifications are required for the various tasks involved: 2.1.1
Installation and maintenance
•
General technical training
•
Knowledge of the standard guidelines relating to safety in the workplace
2.1.2
Electrical installation and replacement
•
Practical electrical training
•
Knowledge of the common electrical safety guidelines
•
Knowledge regarding the operation of the devices in the relevant application (e.g. conveyor belt)
2.1.3
Startup, operation and configuration
•
Knowledge regarding the operation of the devices in the relevant application (e.g. conveyor belt)
•
Knowledge of the software and hardware environment of the relevant application (e.g. conveyor belt)
•
Basic knowledge of Windows 95TM/98TM, Windows NTTM or Windows XPTM
•
Basic knowledge of an HTML browser (e.g. Netscape NavigatorTM)
•
Basic knowledge of data transmission
•
Basic knowledge of bar code technology
2.2
Intended use
The CLV is designed to detect and decode bar codes automatically. It is installed in a reading station and reads bar codes on objects positioned on a conveyor belt, for example. The CLV transfers the data content of the decoded bar codes via its host interface to a host for further processing. Any warranty claims vis-à-vis SICK AG will be rendered invalid if the device is used for any other purpose or if changes are made to the device, also as part of the installation and electrical installation procedures.
2.3
General safety precautions and protection measures
¾ Carefully read the general safety precautions and observe them at all times. This also applies to the warnings provided for the activities described in each chapter of this document. Risk of injury by electrical current! Depending on the type of device, the AMS 40 Connection Module (accessory) for the CLV is connected to a mains voltage of 230 V AC 50 Hz or 115 V AC 50/60 Hz.
¾ When working with electrical equipment, always follow the relevant safety regulations.
8 008 568/K949/10-06-2002
© SICK AG · Division Auto Ident · Germany · All rights reserved
2-1
Page 18
Safety information
Chapter 2
Operating instructions CLV 43x/44x Bar Code Scanner
Laser beam can cause blindness! The CLV uses a class 2 red-light laser. Looking directly at the laser beam can seriously damage your eyesight.
¾ As with sunlight, never look directly into the laser beam. ¾ Do not point the laser beam at persons. ¾ When installing and aligning the CLV, avoid reflections caused by reflective surfaces. ¾ Do not open the housing. (Opening the housing does not deactivate the laser diode).
¾ Observe the laser protection specifications in accordance with DIN EN 60825-1 (latest version).
Laser power The laser operates at a wavelength of λ = 670 nm (visible red light). The power output of the laser beam at the reading window is max. 3.5 mW (CLV 43x/440) or 1.5 mW (CLV 442). The emitted beam is not dangerous to human skin. Laser warning labels The laser warning labels relevant for Europe (Fig. 2-1) are attached at the following positions on the CLV: •
The laser warning symbol and the laser warning in British/US English on Line/Raster scanners are positioned beside the front reading window on the side of the device (Fig. 3-1, Page 3-4).
•
The laser warning symbol and the laser warning in British/US English on Line/Raster scanners with angle attachment and on Line scanners with oscillating mirror are positioned on the wide side of the device at the back of the reading window (Fig. 3-2, Page 3-5).
LASER RADIATON DO NOT STARE INTO BEAM CLASS 2 LASER PRODUCT Max. output : 3.5 mW Pulse duration : 149 s Emitted wavelength : 670 nm EN 60825-1 : 1994 + A11 : 1996
C A U DOTNOT STARE I OINTO N LASER LIGHT BEAM
CLV 43x/440
CLASS II LASER PRODUCT Max. output : 3.5 mW Pulse duration : 74 s Wavelength : 670 nm Complies with 21CFR 1040.10
LASER RADIATON DO NOT STARE INTO BEAM CLASS 2 LASER PRODUCT Max. output radiation : 1.5 mW Pulse duration : 149 s Emitted wavelength : 670 nm EN 60825-1 : 1994 + A11 : 1996
C A U DOTNOT STARE I OINTO N LASER LIGHT BEAM
CLV 442
CLASS II LASER PRODUCT Max. output : 1.5 mW Pulse duration : 74 s Wavelength : 670 nm Complies with 21CFR 1040.10
Fig. 2-1:
Note
Laser warning label found on the CLV (valid for Europe)
The device is supplied with an additional set of laser warning labels in German/US English and in French/US English. If necessary, these can be used to cover the British/US English warning. If the CLV is installed in a machine/panel with the result that the laser warning labels are no longer visible, additional warnings (not included in the scope of delivery) must be provided on the machine beside the emergence aperture of the laser beam.
2-2
© SICK AG · Division Auto Ident · Germany · All rights reserved
8 008 568/K949/10-06-2002
Page 19
Operating instructions
Safety information
Chapter 2
CLV 43x/44x Bar Code Scanner
Internal protective circuits Explanation
The CLV is equipped with monitoring circuits that deactivate the laser diode in the event of a malfunction. Activation and deactivation of the laser diode when reading is controlled by the reading pulse (trigger source). A timer (laser timeout) automatically deactivates the laser diode 10 minutes (default setting) after a continuous reading pulse is initiated in Reading mode with switching input pulse modes "Sensor Input" and "Serial Interface". In this case, the CLV outputs the message: "Laser safety timeout" via the terminal interface. The reading pulse is to be terminated by resetting the pulse signal. The laser diode is activated again by the next reading pulse. The laser timeout can be set in the range of 1 min to 25 h or deactivated (see Table 6-7, Page 6-13). In the "Percentage Evaluation" mode, "Adjusting" mode, "Show CP-limits" and "AutoSetup" mode as well as in the "Free Running" reading mode, the laser diode is constantly activated. In the "reflector polling" trigger mode the laser diode is switched on for each 20th scan.
2.4
Quick stop and quick restart
2.4.1
Switching off the CLV
¾ Switch off the power supply or remove the CLV connector from the connection module. This can result in loss of the following (at the most): •
The application-specific parameter set, if it was only stored temporarily in the CLV
•
The last reading result
•
Daily operating data (operating hours counter, reading interval count, good read count, maximum duration reading interval, minimum duration reading interval, average identification quality)
2.4.2
Restarting the CLV
¾ Switch on the power supply or reattach connector to the connection module. The CLV resumes operation with the parameter set that was last stored permanently and resets the daily operating data.
8 008 568/K949/10-06-2002
© SICK AG · Division Auto Ident · Germany · All rights reserved
2-3
Page 20
Chapter 2
Safety information
Operating instructions CLV 43x/44x Bar Code Scanner
2.5
Environmental information
The CLV is designed to cause minimum impact on the environment. It does not contain any silicone-based materials and, therefore, does not represent any problems for paint sprayers in paint shops, for example. 2.5.1
Power requirements
The power requirements are particularly low: •
The CLV 430/431/432 Line/Raster scanners have a max. power consumption of 4 W
•
The CLV 440/442 Line scanners have a max. power consumption of 5 W
•
The Line scanners with oscillating mirror have a max. power consumption of 6.15 W
The values are given for devices with disconnected switching outputs. 2.5.2
Disposal after final removal from service
Always dispose of irreparable devices in a manner that is not harmful to the environment and in accordance with the applicable national waste disposal regulations. The CLV can be separated into recyclable secondary raw materials and special-category waste (electronic scrap). See also Chapter 7.3 "Disposal", Page 7-2. At present SICK AG does not take back devices which have become unusable or irreparable.
2-4
© SICK AG · Division Auto Ident · Germany · All rights reserved
8 008 568/K949/10-06-2002