Page 33
Operating instructions
Installation
Chapter 4
CLV 43x/44x Bar Code Scanner
4
Installation 4.1
Overview of installation sequence
•
Changing the language version of the laser warning label (if necessary)
•
Selecting the installation location for the CLV
•
Aligning the CLV with the bar code
•
Installing the CLV
•
Installing the AMV/S 40 Connection Module
•
Connecting the CLV to the AMV/S 40 Connection Module
•
Adjusting the CLV
•
Installing the reading pulse sensor for triggering the reading pulse
•
Option with dynamic focus control (CLV 44x): installing the sensor for detecting the object distance
4.2
Installation preparations
4.2.1
Laying out the components to be installed
•
CLV bar code scanner
4.2.2 •
Accessories
Mounting bracket no. 2 020 410 with two M 5 x 8 mm screws and two washers (not included in the scope of delivery of the CLV) or Mounting bracket no. 2 022 564 with three M 5 x 8 mm screws, three spring washers and two M 5 x 12 mm hexagonal bolts with washers (not included in the scope of delivery of the CLV) or Round rod bracket no. 2 023 691 with three M 5 x 8 mm screws and three spring washers (not included in the scope of delivery of the CLV)
•
Alternatively, if the bracket is supplied by the user: – Stable installation device that allows the alignment of the CLV to be varied in the x and y axes. The maximum weight of the CLV (Line/Raster scanner) is 480 g, or 510 g with additional angle attachment, and 620 g as a Line scanner with oscillating mirror (with connecting cable in each case). – Two M5 screws for the CLV. The screw length depends on the wall thickness of the bracket used. Depth of engagement in CLV max. 5 mm from housing surface
•
AMV/S 40 Connection Module, also available with CL 20 mA interface converter (both not included in the scope of delivery of the CLV)
•
Reading pulse sensor for external reading pulse trigger, e.g. photoelectric reflex switch/ photoelectric proximity switch (not included in the scope of delivery of the CLV) – or – Polling reflectors for generating the reading pulse internally
•
8 008 568/K949/10-06-2002
Option with dynamic focus control (CLV 44x): sensor for detecting the object distance, e.g. photoelectric reflex switch/photoelectric proximity switch (not included in the scope of delivery of the CLV)
© SICK AG · Division Auto Ident · Germany · All rights reserved
4-1
Page 34
Chapter 4
Installation
Operating instructions CLV 43x/44x Bar Code Scanner
4.2.3
Laying out the required tools
•
Two/three screws of type M 5 for securing the SICK mounting bracket to the base. The screw length depends on the wall thickness of the base.
•
Set of laser warning labels (if necessary)
•
Tool
•
Measuring tape (up to 2 000 mm)
•
Protractor
4.2.4
Replacing the laser warning label
If necessary, replace the laser warning label on the CLV in GB English/US English with the required language (Fig. 4-1). The device is delivered with a set of laser warnings in: •
German/US English
•
French/US English
See also Chapter 2.3 "General safety precautions and protection measures", Page 2-1. Included label set: (for CLV 43x pictured here)
RAYONNEMENT NE PAS REGARDER DANS LE FAISCEAU APPAREIL A LASER DE CLASSE 2 Puissance max. du rayonnement: 3,5 mW Duré d'impulse : 149 s Longueur d'onde émis : 670 nm EN 60825-1 : 1994 + A11 : 1996
C A U DOTNOT STARE I OINTO N LASER LIGHT BEAM CLASS II LASER PRODUCT
Max. output : 3.5 mW Pulse duration : 74 s Wavelength : 670 nm Complies with 21CFR 1040.10
LASERSTRAHLUNG NICHT IN DEN STRAHL BLICKEN LASER KLASSE 2 Max. Leistung : 3,5 mW Impulsdauer : 149 s Wellenlänge : 670 nm EN 60825-1 : 1994 + A11 : 1996
C A U DOTNOT STARE I OINTO N LASER LIGHT BEAM CLASS II LASER PRODUCT Max. output : 3.5 mW Pulse duration : 74 s Wavelength : 670 nm Complies with 21CFR 1040.10
Fig. 4-1:
Line/Raster scanner example: replacing the laser warning label
4.2.5
Selecting the installation site
When you select the installation site, the distance between the CLV and the host and between the CLV and the bar code are important. Distance between the CLV and the host The CLV can be installed without a connection to the SICK network or to a bus connection max. 1 200 m away from the host. The distance which can be achieved depends on the selected model of the host interface and the set data transfer rate, however (see Table 5-2, Page 5-2). Distance between the CLV and the AMV/S 40 Connection Module The AMV/S 40 Connection Module must not be located further than 10 m from the CLV, since the "CLV Setup" program on the PC accesses the terminal interface of the CLV via this module (RS 232).
4-2
© SICK AG · Division Auto Ident · Germany · All rights reserved
8 008 568/K949/10-06-2002
Page 35
Operating instructions
Installation
Chapter 4
CLV 43x/44x Bar Code Scanner
4.2.6
Mounting accessories
The CLV is secured in position using the two tapped blind holes (M 5) on the bottom narrow side of the device. The position of these holes on the Line/Raster scanner is shown in Fig. 4-2. The dimensions of the CLV housing are shown in Fig. 9-1, Page 9-4 to Fig. 9-3.
Top
4
10
14.4 13.2
10
35.9
4
Bottom
35.9
Tapped blind holes, M 5, 5 mm deep Fig. 4-2:
Line/Raster scanner example: location of the securing threads on the CLV
The CLV can be installed using the following SICK brackets: •
Mounting bracket no. 2 020 410
•
Mounting bracket no. 2 022 564
•
Round rod bracket no. 2 023 691
The brackets are designed to support a variety of installation positions and alignment of the CLV in two planes. Fig. 4-3 and Fig. 4-4 show two mounting examples. The slots in mounting bracket no. 2 020 410 allow a turning freedom of ±15° for the fine adjustment of the CLV. The slots in mounting bracket no. 2 022 564 allow unlimited turning freedom.
Fig. 4-3:
8 008 568/K949/10-06-2002
Line/Raster scanner: CLV installation options using the mounting bracket no. 2 020 410
© SICK AG · Division Auto Ident · Germany · All rights reserved
4-3
Page 36
Installation
Chapter 4
Operating instructions CLV 43x/44x Bar Code Scanner
Fig. 4-4:
Line/Raster scanner: CLV installation options using the mounting bracket no. 2 022 564
The dimensions of the mounting brackets are shown in Chapter 10.12 "Dimensional drawings of the accessories", Page 10-62. Note
Special installation brackets for applications where the CLV is subject to strong mechanical oscillations (vibrations) are available for purchase on request. 4.2.7
Distance between the CLV and the bar code
Basic alignment of the scan line to the bar code Depending on the application, the Line scanner, Raster scanner, or Line scanner with oscillating mirror versions of the CLV is used. Fig. 4-5 shows how the device is aligned with the bar code on the object for each of the three scanning methods.
Line scanner
Fig. 4-5:
Raster scanner
Line scanner with oscillating mirror
Scanning methods: alignment with bar code and conveyor direction
Reading distance between bar code and aperture angle α The distance between the reading window of the CLV and the bar code must not exceed the technical limits. The height of the reading field is shown as a function of the reading distance for various resolutions (module widths) in Chapter 10.2.3 "Reading field diagram for CLV 430 Line/Raster scanner (front reading window)", Page 10-4 to Chapter 10.2.10 "Reading field diagram for CLV 432 Line scanner with oscillating (side reading window)", Page 10-11. Fig. 4-6 shows the definition of the reading distance “a“ from the reading window and of the aperture angle α for each of the three scanning methods.
4-4
© SICK AG · Division Auto Ident · Germany · All rights reserved
8 008 568/K949/10-06-2002
Page 37
Operating instructions
Installation
Chapter 4
CLV 43x/44x Bar Code Scanner
Line scanner
Raster scanner a a a
Reading distance a
Fig. 4-6:
Line scanner with oscillating mirror
Reading distance a
Reading distance a
Definition of the reading distance a and the aperture angle α
The usable aperture angle α is max. 50° for all three scanning methods, even with the additional angle attachment. Due to the V-principle of beam deflection, the reading field height (for evaluating the useful length of the scan line) depends on the reading distance. Angular alignment of the CLV The alignment of the CLV is optimum when the scan line travels over the bar code lines almost at a right angle (90°) (Fig. 4-5). All possible reading angles that can occur between the scan line and the bar code must be taken into consideration (Fig. 4-7 and Table 4-1).
b a Reading area
α: Azimuth angle (tilt) β: Inclination angle (pitch) γ: Rotation angle (skew)
g Reading distance Fig. 4-7:
Line scanner: reading angles between the scan line and the bar code
Angle
Limit value
Azimuth α (tilt)
max. 30° (resolution 0.35 mm, depending on the code print)
Incline β (pitch)
max. 45°
Rotation γ (skew)
max. 45°
Table 4-1: Permissible reading angles between the scan line and bar code
8 008 568/K949/10-06-2002
© SICK AG · Division Auto Ident · Germany · All rights reserved
4-5
Page 38
Installation
Chapter 4
Operating instructions CLV 43x/44x Bar Code Scanner
Preventing surface reflection If the light from the scan line strikes the surface of the bar code perpendicularly, interference may be caused by reflections when the returned light is received. To prevent this effect, the CLV must be installed in such a way that the emitted light is tilted slightly with respect to the vertical axis (Fig. 4-8). Line scanner (front reading window)
Line scanner with 105° angle attachment (side reading window)
Top view
Fig. 4-8:
Top view
Line scanner with oscillating mirror (side reading window)
Side view
Avoiding surface reflection: angle between the emitted light and bar code (tilted away from the vertical axis)
•
The laser beam from the Line/Raster scanner with angle attachment is emitted at an angle of 105° with respect to the housing. Depending on the application, the device can also be installed flush with the conveyor belt.
•
In the case of the Line scanner with oscillating mirror, the laser beam is emitted at an angle of 105° with respect to the housing as it passes through the neutral position (CW = 50) while oscillating. The device can only be flush-mounted with the conveyor belt with limited deflection ranges. Otherwise, the device must also be mounted at an angle of 15° to ensure that the deflection ranges are symmetric.
4.2.8 Explanation
Count direction of the code position CP and code angle CW
The CLV can scan and decode several bar codes with each read. In doing so, it determines the specific local reading diagnosis data for each bar code: •
The position (CP value) of the center of the bar code within the scan line
•
(Scanning method using the oscillating mirror) also the angle of deflection of the scan line (CW value) at which the center of the bar code is recorded
Fig. 4-9 shows the count direction of the code position and code angle. By determining this data, the device can separate identical bar codes (code type, code length, and data content) and assign the bar code data in the reading result to its position on the object.
4-6
© SICK AG · Division Auto Ident · Germany · All rights reserved
8 008 568/K949/10-06-2002
Page 39
Installation
Operating instructions
Chapter 4
CLV 43x/44x Bar Code Scanner
Line scanner with oscillating mirror
Line/Raster scanner with 105° angle attachment
Line/Raster scanner
Front reading window
100
100
CP
CP
0
0
Side reading window
Side reading window
Deviation angle α (aperture angle) in scan direction: 1° = 2 CP (50° = 100 CP) Deflection angle of the scan line perpendicular to the scan direction: 1° = 2 CW (20° = 40 CW) Fig. 4-9:
Count direction of the code position CP in the scan line and of the code angle CW for the oscillating mirror
Tip
In the default setting, the CLV does not output the "CP" and "CW" values (CW only with Line scanner with oscillating mirror) in the reading result on the host interface. If this is desired to evaluate the result in the host, the values can be included in the separator of the output string using CLV Setup. Configuring the separator:
8 008 568/K949/10-06-2002
1.
Select the DATA STRINGS tab.
2.
Click the SEPARATOR field. The dialog window EDIT PARAMETER TFS is displayed.
3.
In the list field, click the CP and/or CW parameters in the desired order. CP and/or CW then appears in the top line.
4.
Confirm the dialog box with "OK".
5.
Perform a download to the CLV. This is done by clicking The DOWNLOAD PARAMETER dialog box is displayed.
6.
Confirm the dialog box by selecting the PERMANENT save option. The CLV outputs the CP value and the CW value on the host interface for each bar code in the reading result. The values are displayed as a 3-digit number in the associated separator.
© SICK AG · Division Auto Ident · Germany · All rights reserved in the toolbar.
4-7
Page 40
Chapter 4
Installation
Operating instructions CLV 43x/44x Bar Code Scanner
4.3
Installing and adjusting the device
4.3.1
Installing the CLV
1.
Prepare the base for installing the bracket as described in Chapter 4.2.2 "Accessories", Page 4-1.
2.
Place the object containing the bar code within the visible range of the CLV (in the position at which it is to be read) with the conveyor belt switched off.
3.
Align the CLV with the bar code (in accordance with the scanning method) in such a way that – with the Line/Raster scanner, the narrow end with the LED indicators is almost parallel with the bar code surface – with the Line/Raster scanner with angle attachment, the wide side with the laser warning labels is almost parallel with the bar code surface – with the Line scanner with oscillating mirror, the wide side with the laser warning labels is almost parallel with the bar code surface All of the possible reading angles must be taken into consideration (see Fig. 4-7, Page 4-5).
4.
If it is relevant for the evaluation, note the count direction of the code position and code angle (see Fig. 4-9, Page 4-7).
5.
Install the CLV bracket on the base.
Risk of damage to the housing! The maximum depth of engagement of the two tapped blind holes M 5 is 5 mm. Longer screws will damage the housing.
¾ Use screws with the correct length. 6.
Screw the screws M 5 through the bracket into the tapped blind holes of the CLV.
7.
Tighten the screws slightly.
8.
Adjust the CLV as described in the following chapter.
4.3.2
Adjusting the CLV
The CLV can be adjusted in "Percentage Evaluation" mode. In this mode, the CLV displays the quality of the bar code reads that enter the CLV reading field statically (the object is not moved on the conveyor belt). The CLV performs 100 scans in Free Running mode and evaluates the reading quality statistically. It outputs the reading result continuously every 2 s via the terminal interface. The behavior of the "Result" LED also indicates the reading quality:
4-8
•
The LED does not light up if the CLV cannot read the bar code (reading quality < 30 %).
•
If the CLV is having problems reading the bar code (reading quality 30 % to 90 %), the LED flashes.
•
The CLV is aligned optimally when the LED lights up constantly (reading quality > 90 %). The scanning frequency in the default setting is 700 Hz.
1.
Connect the CLV to the AMV/S 40 Connection Module and switch on the power supply to the module (see Chapter 5.5.3 "Connecting the power supply", Page 5-4). Once the CLV has started, it outputs an acoustic signal to indicate that the self-test was successfully completed. Shortly afterwards, it outputs two acoustic signals to indicate that it has assumed Reading mode. The "Device Ready" LED lights up.
© SICK AG · Division Auto Ident · Germany · All rights reserved
8 008 568/K949/10-06-2002