Maintenance

Operating instructions

Chapter 7

CLV 43x/44x Bar Code Scanner

7

Maintenance 7.1

Cleaning during operation

To ensure optimum reading performance, the reading window of the CLV must be clean at all times. For this reason, we recommend that you check the reading window at regular intervals, particularly if the device is operated under extreme conditions (dust, abrasion, humidity, finger prints). Laser beam can cause blindness! The CLV uses a class 2 red-light laser. Looking directly at the laser beam can seriously damage your eyesight.

¾ As with sunlight, never look directly into the laser beam. ¾ Switch off the device while it is being cleaned. ¾ Never look directly into the reading window while the device is in operation. Damage to the reading window!

The reading window is made of glass. Scratches and streaks on the window will reduce the reading performance.

¾ Use a mild, non-scouring detergent. ¾ Never use scratching or scouring motions to clean the reading window. Cleaning the reading window

¾ Clean the reading window at regular intervals with a mild, non-scouring detergent, e.g. an antistatic glass cleaning fluid. Fig. 7-1 shows the areas that require cleaning. Use a soft, lint-free cloth.

¾ If necessary, clean the LEDs on the rear of the device. Line/Raster scanner

Line scanner with oscillating mirror

Line/Raster scanner with angle attachment

Clean here: Fig. 7-1:

Cleaning the reading window

8 008 568/K949/10-06-2002

© SICK AG · Division Auto Ident · Germany · All rights reserved

7-1

Page 94

Chapter 7

Maintenance

Operating instructions CLV 43x/44x Bar Code Scanner

Cleaning other optical surfaces:

¾ If an external reading pulse generator and/or object-height detection sensors are used (e.g. photoelectric reflex switches), make sure to clean the relevant optical surfaces (Fig. 7-2). Contamination on these surfaces can cause switching errors.

¾ If the reading pulse is generated by reflector polling, make sure to clean the surface of the reflector.

Fig. 7-2:

Cleaning the external optical sensors (reading pulse generator, object-height detector)

7.2

Maintenance

The CLV does not require any maintenance. Its self-monitoring functions ensure fault-free operation over long periods of time. Any faults or malfunctions are displayed via the terminal interface. If they are plain text, they can be displayed on the PC screen in the extended mode of the Terminal Emulator in the CLV Setup program. Additional errors are displayed as number combinations in the fourth field from the left on the bottom, on the status line (see Chapter 8.3 "Error messages", Page 8-2 ).

7.3

Disposal

Irreparable devices or devices that are no longer required are to be disposed of in an environmentally-friendly manner: 1.

Always observe the applicable national waste disposal regulations.

2.

Remove the CLV housing.

3.

Remove the electronic modules and the connection cable.

4.

Remove the glass panel from the reading window and send it to be recycled.

5.

Send the chassis and cover to be recycled.

6.

Send the electronic modules and connection cable for disposal as special waste.

At present SICK AG does not take back devices which have become unusable or irreparable.

7-2

© SICK AG · Division Auto Ident · Germany · All rights reserved

8 008 568/K949/10-06-2002

Page 95

Operating instructions

Troubleshooting

Chapter 8

CLV 43x/44x Bar Code Scanner

8

Troubleshooting 8.1

Overview of the possible errors and malfunctions

8.1.1

Installation errors

•

CLV aligned incorrectly with the object carrying the bar code (e.g. blanking)

•

Reading pulse sensor positioned incorrectly

•

With dynamic focus control: sensor for object height detection positioned incorrectly

8.1.2

Electrical connection errors

•

Interfaces on the CLV connected incorrectly (wiring error in AMV/S 40)

•

Host interface on AMV/S 40 configured incorrectly

8.1.3

Parameterization errors

•

Functions not adjusted to local conditions, e.g. communication parameters on the host interface are set incorrectly

•

Technical limits of the device not taken into consideration, e.g. relationship between the scanning frequency and the reading distance

8.1.4

Malfunctions during operation

•

Laser timeout for laser diode elapsed

•

Device error (hardware/software)

8.2

Monitoring errors and malfunctions

The CLV is self-monitoring in operation:

8 008 568/K949/10-06-2002

•

After the power supply has been switched on, the CLV automatically carries out a selftest, in which it checks important hardware components, before it is initialized (parameter set loaded and device functions initialized). The self-test can be repeated at any time by canceling Reading mode. For calling up, see Chapter 6.5.9 "Self-test", Page 6-30.

•

If the CLV detects an error during the self-test or at any other time, it outputs the error status ST=3 via the host interface. Prerequisite: the error status is enabled for transmission. Transfer is disabled in the default setting. The CLV displays the diagnosed error as a numeric combination in the fourth field from the left on the bottom, on the status line of CLV Setup (Table 8-1).

•

While it is in operation, the CLV constantly monitors the laser diode and speed of the polygon mirror wheel. In addition, a watchdog circuit responds to error statuses.

•

A timer automatically deactivates the laser diode 10 minutes (default setting) after a continuous reading pulse is initiated in Reading mode with switching input pulse modes "Sensor Input" and "Serial Interface" but it does not complete the Reading mode. In this case, the CLV outputs the message: „Laser safety timeout". The reading pulse must be terminated by resetting the pulse signal. The laser diode is activated again by the next reading pulse.

© SICK AG · Division Auto Ident · Germany · All rights reserved

8-1

Page 96

Chapter 8

Troubleshooting

Operating instructions CLV 43x/44x Bar Code Scanner

8.3

Error messages

The CLV outputs error messages in English on the terminal interface only. Additional errors are displayed as number combinations on the status line of CLV Setup. Table 8-1 contains a list of the messages in alphabetical order. For warnings, see Chapter 6.6.3 "Warnings", Page 6-32. Displaying messages: To display the messages on the PC in the CLV Setup user interface, proceed as follows: 1.

Click in the toolbar. The Terminal Emulator window is then displayed.

2.

In the TERMINAL MODE group, click the EXTENDED radio button.

Message

Meaning

Possible cause

Remedy

"CLV SYS-Failure: xxx" 011 RAM error 012 RAM error 013 RAM error 051 Mirror wheel speed out of tolerance 061 Mirror interval out of tolerance 071 Error: laser shutter 091 to 095 Error focus adjustment (CLV 44x) 201 to 215 DSP error

The CLV has diagnosed a system error. The "Device Ready" LED does not light up or it extinguishes. The system is restarted.

Device fault

If this system error occurs again after the CLV is restarted: Contact the SICK Service department.

"EEPROM Check fault, default parameters loaded"

The CLV has diagnosed an irregularity in the EEPROM and downloads the entire default setting to the RAM instead of the permanently stored application-specific parameters.

Device fault

Contact the SICK Service department.

"EEPROM - reading fault"

The CLV cannot download the Device fault application-specific parameters, permanently stored in the EEPROM, to the RAM.

Contact the SICK Service department.

"EEPROM - writing fault"

The CLV cannot write the current parameters in the RAM to the EEPROM.

Device fault

Contact the SICK Service department.

"Focus table inconsistent: defaults loaded"

The CLV has diagnosed an Device fault irregularity in the internal reference table for the focus positions selected by the user. It therefore downloads the default setting of the distance configurations.

Contact the SICK Service department.

Table 8-1: Error message output on the terminal interface

8-2

© SICK AG · Division Auto Ident · Germany · All rights reserved

8 008 568/K949/10-06-2002

Page 97

Operating instructions

Troubleshooting

Chapter 8

CLV 43x/44x Bar Code Scanner

Message

Meaning

Possible cause

Remedy

"Host – receive fault"

• Host receive set incorrectly The host has requested the data output string last sent by • Data transmission interrupted the CLV three times; NAK has e.g. by cable break been issued with each attempt.

"Host – transfer too slow"

In the CLV, data is available for output faster than it is transmitted to the host.

• Baud rate too low Check the configuration of the host interface. • Incorrect protocol type selected • Protocol timeout too long for the reading pulse frequency

"Host – transmit fault"

The CLV cannot correctly receive the data sent by the host.

• Host interface of the CLV configured incorrectly • Data transmission interrupted e.g. by cable break

• Check host. • Check connecting cable and monitor data transmission at the host interface. To do so, upload from the CLV using the CLV Setup program, select the AUX. INTERFACE tab and select MONITOR HOST INTERFACE in the drop-down list. Download to the CLV! Start the Terminal Emulator.

• Check the CLV and host. • Check connecting cable and monitor data transmission at the host interface. To do so, upload from the CLV using the CLV Setup program, choose the AUX. INTERFACE tab and select MONITOR HOST INTERFACE from the drop-down list. Download to the CLV! Start the Terminal Emulator.

"Master/slave – trigger to soon"

The new reading pulse for the Timeout for the master is too long Check the coordination between master is received before its reading pulse and timeout. To do timeout has elapsed. so, upload from the CLV using the CLV Setup program, choose the DEVICE CONFIGURATION tab and change the MASTER TIMEOUT in the CLV ARRANGEMENT group. Download to CLV!

"More than one code found"

AutoSetup was not successful.

"No polls?"

• Data connection cables faulty Network operation: The CLV is waiting for polls by • CLX 200 not ready the CLX 200 Network • Incorrect device number Controller. parameterized • Inadvertently parameterized for network operation

More than one bar code was presented to the CLV.

Repeat AutoSetup. Make sure that only one bar code is in the visible range of the CLV (in particular with oscillating mirror!) • Check cables. • Switch on CLX 200. • Device number: parameterize 01 to 31. • Check the configuration of the host interface. To do so, upload from the CLV using the CLV Setup program, choose the HOST INTERFACE tab and check the settings in the INTERFACE PROTOCOL group. Download any changes to the CLV!

Table 8-1: Error message output on the terminal interface

8 008 568/K949/10-06-2002

© SICK AG · Division Auto Ident · Germany · All rights reserved

8-3

Page 98

Chapter 8

Troubleshooting

Operating instructions CLV 43x/44x Bar Code Scanner

Message

Meaning

Possible cause

"No valid code found"

AutoSetup was not successful.

No bar code was presented to Repeat AutoSetup. the CLV or the reading quality did Make sure that the bar code is not reach 75 %. located within the reading range of the CLV.

"Oscillating mirror faulty"

The CLV cannot operate the oscillating mirror or cannot initialize the mirror.

Device fault

Contact the SICK Service department.

"Slave string faulty"

Data transmission error between a slave and the master.

Data connection cables faulty

If the error continues to occur, check the connecting cable between all CLVs.

"Wrong number of slaves"

• The parameterized number of During the master timeout, the master receives more or slaves does not match the fewer reading results from the actual number of connected slaves than expected from slaves. the number of slaves that the master has entered.

• Timeout for the master is too short • The data connection between the slaves has been interrupted "Wrong parameters - master/ slave"

Individual parameters were changed after the master/slave arrangement was activated. These parameters were not compatible with the automatic settings for this function by the CLV.

Remedy

• Check the entered number of slaves. To do so, upload from the CLV using the CLV Setup program, choose the DEVICE CONFIGURATION tab and check the NUMBER OF SLAVES in the CLV ARRANGEMENT group. Download any changes to the CLV! • As above, but check the timeout defined for the master • Check the cables between the slaves.

Deviations from the following values: • Test string: no (slaves) • Aux. input: no (slaves) • Pulse: serial interface or switching input • RK 512: without response telegram

Check the correct settings on the DATA STRINGS, AUXILIARY INTERFACE, DEVICE CONFIGURATION, and HOST INTERFACE tabs in the CLV Setup program.

© SICK AG · Division Auto Ident · Germany · All rights reserved

8 008 568/K949/10-06-2002

Table 8-1: Error message output on the terminal interface

8-4

Page 99

Operating instructions

Troubleshooting

Chapter 8

CLV 43x/44x Bar Code Scanner

8.4

ST error status in the reading result of a bar code

Value

Meaning

Possible cause

Remedy

0

"Good Read"

–

Not applicable

1

Incorrect check digit

• The check digit calculated by the CLV during the reading process does not match that printed in the bar code.

Check whether the check digits in the bar code which were generated by the print process are correct.

2

No bar code of the enabled code type • No bar code in the CLV's reading range • Synchronize the pulse of the CLV found according to the evaluation during the reading pulse with the entry of a bar code into the criteria reading range. • Code type/length in the CLV not • Correct the code configuration enabled for decoding parameters. • Reading window obstructed/dirty • Check the reading window.

3

Device fault

Device fault

Call up the self-test! (see Chapter 6.5.9 "Self-test", Page 6-30) If result ≠ 000: Contact the SICK Service department.

5

Required number of successful multiple reads for the bar code not reached.

• Conveyor speed of the object is too high • Scanning frequency is too low • Ladder-type arrangement for bar code relative to the conveyor direction: code height (bar length) too poor • Print quality too poor

• Check the conveyor speed. • Adjust the scanning frequency. • Check the code height. • Check the print quality.

6

• The parameterized number of slaves • Check the entered number of Master: Number of slave reading results does does not match the actual number of slaves. not match the parameterized number slaves available. of slaves • Timeout for the master is selected too • Check the master timeout setting. short. • Data connection between slaves and/ • Check the cables between the or the master has been slaves and the master. interrupted.

7

The source of the reading result is the The bar code was not detected by the – auxiliary input via the terminal reading function of the CLV, but was interface. entered subsequently with the auxiliary function of the terminal interface and sent to the host in a separate data string.

9

The scanned object does not have a bar The OUTPUT FILTER function is also activated for the code comparison. code that matches the specified match The CLV has detected valid bar codes. code. However, these do not match the active match code(s)

–

A

The CHECK MAX. NUMBER OF CODES function is active. The number of valid bar codes detected by the CLV in Reading mode exceeds that specified under NUMBER OF CODES: MAXIMUM. In place of bar codes it repeatedly outputs the defined error string until the number specified under NUMBER OF CODES: MINIMUM is reached.

This message is used to indicate errors on the objects (e.g. check whether objects are homogeneous: mix with incorrect objects).

One object in a set of objects with a constant number of bar codes, for example, contains more bar codes than defined in the application.

Table 8-2: Meaning of the ST error status in the reading result

8 008 568/K949/10-06-2002

© SICK AG · Division Auto Ident · Germany · All rights reserved

8-5

Page 100

Troubleshooting

Chapter 8

Operating instructions CLV 43x/44x Bar Code Scanner

Value

Meaning

Possible cause

Remedy

D

The "Code 32" evaluation option is activated for Code 39. The CLV is attempting to interpret 6digit C39 bar codes as C32 bar codes (output as 9-digit decimal values).

The read 6-digit bar code is not a C32 bar – code. The CLV outputs the defined error string instead.

Table 8-2: Meaning of the ST error status in the reading result

8-6

© SICK AG · Division Auto Ident · Germany · All rights reserved

8 008 568/K949/10-06-2002

Page 101

Operating instructions

Troubleshooting

Chapter 8

CLV 43x/44x Bar Code Scanner

8.5

Troubleshooting

The following are required for troubleshooting purposes using the tables below: •

These operating instructions

•

Tool

•

A tape measure (up to 2 000 mm)

•

A digital measuring device (ammeter/voltmeter)

•

A PC running "CLV Setup"

•

RS 232 data connection cable (pins 2 and 3 crossed), e.g. no. 2 014 054

8.5.1

General malfunction: CLV not ready

Malfunction

Possible cause

1. The "Device Ready" LED is not lit. The "Result 1" switching output (default setting: "Device Ready") is not outputting a pulse.

After switching on the power supply (10 to 30 V DC): • The CLV has no power

• The CLV detected a device error during the self-test.

Remedy

• Check the wiring (power connector fitted securely to the AMV/S 40 Connection Module). Measure voltage at pin 1 and pin 5. • Switch the CLV off and on again. Does the LED light up? If not, contact the SICK Service department.

During operation: • The CLV is not in "Reading" mode

• Return to Reading mode using the CLV Setup program (see Chapter 6.5.1 "Reading mode (standard operating mode)", Page 6-20). • Terminate reading pulse. • The CLV has deactivated the Check the reading pulse laser diode 10 min. (default function. Parameterize new setting) after the start of the pulses or laser timeout current reading pulse duration using the CLV Setup (Pulse mode: sensor input/ user interface (see serial interface). Chapter 6.4.3 "Parameterization guide", Page 6-9). Table 8-3: Troubleshooting: restoring operation (Reading mode)

8 008 568/K949/10-06-2002

© SICK AG · Division Auto Ident · Germany · All rights reserved

8-7