Page 86
Chapter 6
Operation
Operating instructions CLV 43x/44x Bar Code Scanner
If the reading diagnosis is to remain inactive, this can be set via the AUXILIARY INTERFACE tab. 1.
In the AUXILIARY INTERFACE drop-down list, select READING DIAGNOSIS.
2.
Perform a download to the CLV. This is done by clicking in the toolbar.
The DOWNLOAD PARAMETERS dialog box is then displayed. 3.
Confirm the dialog box by selecting the PERMANENT save option.
The terminal interface is now set to the "Reading Diagnosis" mode. 6.5.7
Monitor host interface
Function of the terminal interface. In this mode, the CLV outputs the data traffic of its host interface via the terminal interface. Protocol driver handshakes and protocol-specific data, such as start and stop characters, are suppressed here (Table 6-9). Each data string is displayed on a separate line on the screen. Direction of data
Output format
Represenation on screen
CLV receives from host <STX> I data <CR> <LF> <ETX>
I data
CLV sends to host
O data
<STX> O data <CR> <LF> <ETX>
Table 6-9: "Monitor Host Interface" function
"Monitor Host Interface" is activated via the AUXILIARY INTERFACE tab. 1.
In the AUXILIARY INTERFACE drop-down list, choose MONITOR HOST INTERFACE.
2.
Perform a download to the CLV. This is done by clicking The DOWNLOAD PARAMETER dialog box is displayed.
3.
Confirm the dialog box by selecting the TEMPORARY save option.
in the toolbar.
The terminal interface is then set to the "Monitor Host Interface" until the CLV is switched off again. Displaying the data traffic of the host interface in the Terminal Emulator The data traffic of the host interface can be displayed in the Terminal Emulator of CLV Setup. Fig. 6-12 shows an example of how the reading result can be output.
6-28
1.
Choose the serial interface as the external trigger source for the reading pulse (see Triggering the reading pulse via the Terminal Emulator, Page 6-23).
2.
Click in the toolbar. The Terminal Emulator window is then displayed. The CLV is in Reading mode.
3.
Click the SW-TRIGGER ON button or press [F7]. The scan line then appears.
4.
Present the bar code sample from Fig. 6-1, Page 6-4.
5.
Click the SW-TRIGGER OFF button or press [F8]. CLV Setup outputs the reading result in the terminal emulator. Example: "O 0123412345".
© SICK AG · Division Auto Ident · Germany · All rights reserved
8 008 568/K949/10-06-2002
Page 87
Operation
Operating instructions
Chapter 6
CLV 43x/44x Bar Code Scanner
Fig. 6-12: CLV Setup: output of the reading result of the host interface in the Terminal Emulator at the beginning (in this case: O = Output)
Note
Large amounts of data received at high speeds via the host interface and high data transfer rates may cause the flow of host interface traffic to no longer be completely displayed on the terminal interface (display " ... "). This is caused by the slower data transfer speed of the terminal interface (9 600 bit/s). In the default setting, the CLV transmits the data content of the bar code(s) as a data string via the host interface. The header, separator and terminator are blank.
Tip
8 008 568/K949/10-06-2002
The structure of the data output string of the host interface can be configured via the DATA STRINGS tab. Up to 10 elements, consisting of constants and/or reading diagnosis data, can be entered in the header, separator and terminator. 1.
Choose the DATA STRINGS tab.
2.
Click the HEADER drop-down list. The dialog window EDIT PARAMETER TFH is displayed.
3.
Click the desired constants or placeholders for the reading diagnosis data. The selected elements appear in the text box at the top of the dialog box in the sequence in which they were selected.
4.
Confirm the dialog box with "OK".
5.
Repeat this procedure for the separator and terminator.
6.
Perform a download to the CLV. This is done by clicking The DOWNLOAD PARAMETER dialog box is displayed.
7.
Confirm the dialog box by selecting the PERMANENT save option. The CLV outputs the selected elements in the data output string of the host interface with the next reading result.
© SICK AG · Division Auto Ident · Germany · All rights reserved in the toolbar.
6-29
Page 88
Chapter 6
Operation
Operating instructions CLV 43x/44x Bar Code Scanner
6.5.8
Auxiliary input
Function of the terminal interface. In this mode, the CLV accepts a bar code entered at the terminal interface (via the keyboard or handheld scanner with decoder). It sends the bar code to the host in a separate data string via its host interface. No Reads can, therefore, be corrected by transmitting missing bar codes subsequently. Chapter 10.9.2 "Auxiliary input via terminal interface", Page 10-53 describes this function and the associated procedure in greater detail. 6.5.9
Self-test
After the CLV has been switched on, it performs a self-test before it is initialized with the parameter set. The test can be called up explicitly at any time via CLV Setup. During the selftest, the CLV checks that its hardware components are functioning correctly. A final message via the terminal interface provides information on the test result. The CLV does not output a reading result during the test routine. 1.
Click in the toolbar. The Terminal Emulator window is then displayed. The CLV is in Reading mode.
2.
Click SELF TEST under DEVICE MODE. The "Device Ready" LED is extinguished. The CLV cancels the Reading mode and starts the test routine. After a few seconds, the CLV outputs the encoded test result in the form of a code number (Fig. 6-13).
3.
To return to the Reading mode, click READING MODE or close the Terminal Emulator. The CLV returns to Reading mode. The "Device Ready" LED lights up.
Fig. 6-13: CLV Setup: displaying the self-test result in the Terminal Emulator
The code number "15000" means that the self-test was completed successfully and that no faults were diagnosed. Chapter 8.3 "Error messages", Page 8-2, lists the error key together with the associated corrective measures.
6-30
© SICK AG · Division Auto Ident · Germany · All rights reserved
8 008 568/K949/10-06-2002
Page 89
Operating instructions
Operation
Chapter 6
CLV 43x/44x Bar Code Scanner
6.5.10
Performing device functions of the CLV in the dialog box
CLV Setup enables a number of CLV functions to be executed interactively. CLV Setup prompts the user to carry out specific actions and provides information on the progress of the function being executed. The following functions are available: •
AutoSetup
•
Match code Teach-in
•
Show CP-limits
•
Adjusting mode
•
Analyze scanner network (only if the CAN interface is used)
¾ In the menu bar, select the desired function from TOOLS, DEVICE FUNCTIONS. – or – Press the [F2] key. The EXECUTE DEVICE FUNCTIONS dialog box is then displayed. Choose the desired function in the EXECUTE menu in the menu bar. CLV Setup starts the function and, where appropriate, prompts the user to carry out the necessary actions. Fig. 6-14 shows an example of the dialog box that appears after AutoSetup has been started.
Fig. 6-14: CLV Setup: dialog box for executing AutoSetup
8 008 568/K949/10-06-2002
© SICK AG · Division Auto Ident · Germany · All rights reserved
6-31
Page 90
Chapter 6
Operation
Operating instructions CLV 43x/44x Bar Code Scanner
6.6
CLV messages
The CLV outputs system messages, warnings and error messages in English in response to the actions carried out by the user. The messages are output in plain text via the terminal interface only. 6.6.1
Displaying messages
To display the messages on the PC in the CLV Setup user interface, proceed as follows: 1.
Click in the toolbar. The Terminal Emulator window is then displayed.
2.
In the TERMINAL MODE group, click the EXTENDED radio button.
The CLV then outputs messages in response to events that occur while the bar code is being read. The messages are only output in the extended mode of the Terminal Emulator! 6.6.2
System messages
System messages confirm that an action has been carried out successfully, e.g. changing the operating mode. No other actions are required here. Chapter 6.2 "Default setting", Page 6-1 explains the contents of the messages. 6.6.3
Warnings
Warnings indicate that it was not possible to perform an action or that the values set for the parameters can cause an error while the bar code is being read. Table 6-10 lists the warning messages in alphabetical order together with the associated corrective measures. Message
Meaning
Remedy
"Warning: Master Timeout"
Duration of the set master timeout is too short
Optimize the master timeout using the DEVICE CONFIGURATION tab in the user interface of CLV Setup. Download to the CLV! (see also technical information "Master/Slave with CLV Bar Code Scanners", no. 8 007 675, English version)
Table 6-10: Warning
6.6.4
Error messages
Error messages indicate the following error sources: •
A device defect
•
Incorrect parameter settings
•
Errors during data transfer to the host
Chapter 8.3 "Error messages", Page 8-2 lists the messages in alphabetical order together with the associated corrective measures.
6-32
© SICK AG · Division Auto Ident · Germany · All rights reserved
8 008 568/K949/10-06-2002
Page 91
Operating instructions
Operation
Chapter 6
CLV 43x/44x Bar Code Scanner
6.7
Switching off the CLV
1.
If the parameter set was modified in CLV Setup or was only stored temporarily in CLV via a download, the parameter set must be stored permanently in the CLV by choosing the PERMANENT storage option.
2.
Save parameter set as a "*.scl" configuration file in CLV Setup.
3.
Switch off the power supply of the AMV/S 40 or pull the plug of the CLV from the connection module.
The last parameter set stored permanently in the CLV remains valid. We recommend that you print out the configuration file in order to archive the parameter set.
8 008 568/K949/10-06-2002
1.
Click in the toolbar. The PRINT FILE dialog box is then displayed.
2.
Enter a comment in the input field in order to assign the printout to the CLV. Confirm dialog box with "OK". The PRINT dialog box for configuring the printer is then displayed.
3.
Edit the dialog box accordingly and confirm. CLV Setup prints out the current configuration file in the form of a table.
© SICK AG · Division Auto Ident · Germany · All rights reserved
6-33
Page 92
Operation
Chapter 6
Operating instructions CLV 43x/44x Bar Code Scanner
Notes