Page 77
Operation
Operating instructions
Chapter 6
CLV 43x/44x Bar Code Scanner
3.
If AutoSetup is unsuccessful again, check whether the CLV is able to read the bar code correctly (reading distance, tilt, more than one bar code in the reading field).
Terminating AutoSetup prematurely: It is not possible to abort AutoSetup here.
¾ To prevent parameter values in the RAM of the CLV from being overwritten, move the bar code away from the reading field and wait for the CLV to output an error message (AutoSetup must not supply valid settings). Checking parameter values stored in the CLV (after parameters are saved):
Note
1.
Switch the power supply of the connection module (of the CLV) off and on again.
2.
Perform an upload from the CLV. This is done by clicking
3.
Check the values in the READING CONFIGURATION and CODE CONFIGURATION tabs. Only one code type may be active on the CODE CONFIGURATION tab.
in the toolbar.
The CLV does not enter any real values in the parameter set for the parameters "Minimum Distance" or "Minimum Bar Width" as it is not able to determine any absolute dimensions. The values displayed in the READING CONFIGURATION tab or the EDIT DISTANCE CONFIGURATIONS dialog box do not, therefore, reflect the actual situation. Checking the stored reading and code configurations: Once AutoSetup has been completed successfully, check the CLV settings as follows: 1.
Click in the toolbar. The Terminal Emulator is launched. The CLV is in Reading mode.
2.
Click PERCENT EVAL under DEVICE MODE. The dialog box for the distance configuration is then displayed.
3.
Click the appropriate distance configuration for reading the bar code. – CLV 43x: distance configuration no. 1 – CLV 44x: distance configuration no. 1
8 008 568/K949/10-06-2002
4.
Confirm the dialog box with "OK". The CLV starts the percentage evaluation and displays the reading quality of each set of 100 scans continuously (see Chapter 6.5.2 "Percentage evaluation", Page 6-23).
5.
Present the application-specific bar code at the teach-in distance (at the minimum and maximum reading distance if the bar code in the application is in a variable reading range).
6.
Check the reading quality in the Terminal Emulator. This should be between 70 and 100 %.
© SICK AG · Division Auto Ident · Germany · All rights reserved
6-19
Page 78
Chapter 6
Operation
Operating instructions CLV 43x/44x Bar Code Scanner
6.5
Operating modes and outputting the reading result
The following CLV operating modes/functions can be selected in CLV Setup: Standard operating mode •
Reading mode
For startup •
Percentage evaluation
•
Adjusting mode
For adapting device to application •
AutoSetup (automatic adaptation to reading conditions): See Chapter 6.4.4 "Configuring the CLV with AutoSetup", Page 6-15
•
Parameterizing (configuration): See Chapter 6.4.1 "Configuring CLV with the user interface of CLV Setup", Page 6-5
•
Profile programming (configuration): See Chapter 10.5.2 "Profile programming", Page 10-37
•
Teach-in match code 1/activate match code comparison with "Sensor 2" switching input: See Chapter 10.9.1 "Triggering the Teach-in match code 1 via the "Sensor 2" switching input", Page 10-48
•
Show CP-limits
For monitoring purposes/correcting faults •
Displaying and editing operating data
•
Reading diagnosis
•
Monitoring host interface
•
Auxiliary input
•
Self-test
6.5.1
Reading mode (standard operating mode)
The CLV performs a self-test after it has been switched on. It is then set to the Reading mode and confirms this by outputting two consecutive acoustic signals via the beeper. In the default setting, the "Sensor 1" switching input is the (external) trigger source of the reading pulse. The reading result is output by the CLV at the end of the reading pulse via the host interface (default setting) and terminal interface. The reading result of the terminal interface can be displayed in the CLV Setup Terminal Emulator. The CLV terminal interface must be set to the READING DIAGNOSIS mode for this purpose. This mode is selected for the default setting. The reading result of the terminal interface has a fixed, invariable format. The Reading mode can be called up by choosing VIEW in the menu bar or via the Terminal Emulator. Line scanner with oscillating mirror: In the Reading mode, the CLV deflects (by default) the scan line about the position CW = 50 at a frequency of 1 Hz and a maximum angle of ±20°. 50 CW correspond to a light emergence under 105°.
6-20
© SICK AG · Division Auto Ident · Germany · All rights reserved
8 008 568/K949/10-06-2002
Page 79
Operation
Operating instructions
Chapter 6
CLV 43x/44x Bar Code Scanner
Displaying the reading result in the Terminal Emulator 1.
Raster scanner: Select the standard decoder (see Chapter 6.3.2 "Starting up the Raster scanner for the first time with the factory default setting", Page 6-4).
2.
Click in the toolbar. The Terminal Emulator dialog box is then displayed.
3.
Click READING MODE under DEVICE MODE.
4.
Present the bar code pattern from Fig. 6-1, Page 6-4 to the CLV and activate the reading pulse. The "Laser On" LED lights up. The scan line appears (see also Chapter 6.3.1 "Starting up the Line scanner/Line scanner with oscillating mirror with the factory default setting", Page 6-3).
5.
Terminate reading pulse. The CLV outputs a tone via the beeper to indicate that the reading result is displayed in the output window of the Terminal Emulator. The "Result" LED lights up for duration of 100 ms (default setting).
Fig. 6-6 shows two examples of reading result output: "Good Read" and "No Read". The reading result comprises the data contents of the bar code(s) and the reading diagnosis data. Fig. 6-7 explains the structure and function of the reading diagnosis data for Good Read, and Fig. 6-8 for No Read. Note
The CLV only outputs several bar codes in the reading result if the parameterized minimum and maximum number of bar codes is > 1, and several bar codes have been presented. The number of bar codes to be read/output for each reading interval can be selected on the CODE CONFIGURATION tab in the NUMBER OF CODES group.
Fig. 6-6:
8 008 568/K949/10-06-2002
CLV Setup: displaying the reading result of the terminal interface in the terminal emulator
© SICK AG · Division Auto Ident · Germany · All rights reserved
6-21
Page 80
Operation
Chapter 6
Operating instructions CLV 43x/44x Bar Code Scanner
Successful read (Good Read): TT =_940 ms MG =_29 % n =_1 AK = 1 0123412345 C39 _98 % ST = 0 CP =_47 CL = 10 CA = 249 CS = 210 CK = 179 DI = R with: 1st line: TT = MG = n = AK = 2nd line: 0123412345 = 3rd line: C39 = _98 % = ST = CP = CL = CA = CS = CK = DI =
Fig. 6-7:
Reading interval time Long-term mean value of CG Number of recognized codelabels No. of distance configuration used Data content of the bar code ID: Code type code 39 Identification quality Read status (ST = 0, Good Read) Code position Code length (character count) Scanning expenditure Code security Code continuity Decoding direction (F = scanning direction, R = opposite scanning direction)
Reading result of the terminal interface: structure for "Good Read"
No Read: TT =__700 ms MG =_28 % n =_0 AK = 1 no code!
with: 1st line: TT MG n AK 2nd line: no code!
Fig. 6-8:
Note
= Reading interval time = Long-term mean value of CG = Number of recognized codelabels = No. of distance configuration used = No bar codes found!
Reading result of the terminal interface: structure for "No Read"
In the Reading mode, the CLV does not output the contents of the polling reflector. The reading result of the host interface can also be displayed. Chapter 6.5.7 "Monitor host interface", Page 6-28 describes the procedure for this and the structure of the reading result in the default setting.
6-22
© SICK AG · Division Auto Ident · Germany · All rights reserved
8 008 568/K949/10-06-2002
Page 81
Operating instructions
Operation
Chapter 6
CLV 43x/44x Bar Code Scanner
Triggering the reading pulse via the Terminal Emulator In the default setting, the "Sensor 1" switching input is the (external) trigger source of the reading pulse. The reading pulse can also be triggered directly via the terminal emulator of CLV Setup for test purposes. To do so, a different trigger source must be selected temporarily in the CLV. 1.
Choose the DEVICE CONFIGURATION tab.
2.
Click the EDIT READING TRIGGER button. The EDIT READING TRIGGER dialog box is then displayed.
3.
Click SERIAL INTERFACE.
4.
Confirm the dialog box with "OK".
5.
Perform a download to the CLV. This is done by clicking The DOWNLOAD PARAMETER dialog box is displayed.
6.
Confirm the dialog box by selecting the TEMPORARY save option. The serial interface has been activated as the trigger source of the reading pulse and is ready to receive appropriate commands.
7.
Click in the toolbar. The Terminal Emulator dialog box is then displayed. The CLV is in Reading mode.
8.
Click the SW-TRIGGER ON button or press [F7]. CLV Setup sends a start command to the CLV. The "Laser On" LED lights up. The scan line then appears.
9.
Present the bar code sample from Fig. 6-1, Page 6-4.
in the toolbar.
10. Click the SW-TRIGGER OFF button or press [F8]. CLV Setup sends a stop command to the CLV. The "Laser On" LED is extinguished. The CLV switches off the laser diode. The CLV outputs an acoustic signal via the beeper to indicate that the reading result is displayed in the output window of the terminal emulator. The "Result" LED lights up for a duration of 100 ms (default setting). 6.5.2
Percentage evaluation
In the Percentage evaluation mode, the quality of the reading function (concerning bar codes which are statically put in place into the reading field of the CLV) is assessed (no conveyor movement). The CLV performs 100 scans in Free Running mode and evaluates the reading quality. It outputs the reading result continuously every 2 sec. via the terminal interface. The reading results can be displayed in the Terminal Emulator of CLV Setup. The standard decoder has to be set temporarily for the percentage evaluation. The Percentage evaluation mode can be called up by choosing VIEW in the menu bar or via the Terminal Emulator. Line scanner with oscillating mirror: In "Percentage evaluation" mode, the CLV behaves as follows:
8 008 568/K949/10-06-2002
– in "Oscillating" mode (default setting: oscillating with fixed Amplitude) switches to Oscillating mode and positions the scan line at the angle CW = 50 (corresponds to an angle of emergence under 105°). This position cannot be changed.
– in "One-shot" mode, it also positions the scan line under the angle CW = 50.
– in "Fixed Position" mode, on the other hand, the selected scan line position remains unchanged.
© SICK AG · Division Auto Ident · Germany · All rights reserved
6-23
Page 82
Chapter 6
Operation
Operating instructions CLV 43x/44x Bar Code Scanner
1.
Select the CODE CONFIGURATION tab.
2.
In the DECODER group, click the STANDARD radio button.
3.
Perform a download to the CLV. This is done by clicking The DOWNLOAD PARAMETER dialog box is displayed.
4.
Confirm the dialog box by choosing the TEMPORARY storage option (or PERMANENT for Raster scanners). The CLV then uses the standard decoder.
5.
Click in the toolbar. The Terminal Emulator window is then displayed. The CLV is in Reading mode.
6.
Click PERCENT EVAL under DEVICE MODE. The dialog box for choosing the distance configuration is then displayed.
7.
in the toolbar.
Click the appropriate distance configuration for the reading distance: – CLV 43x: distance configuration no. 1 (default setting) if no DC-specific restriction of the active evaluation range of the scan line has been carried out – CLV 44x: distance configuration that matches the reading distance of the object (default setting: no. 1, focus position F = 140 mm).
8.
Confirm the dialog box with "OK". The "Device Ready" LED is extinguished. The CLV initiates the percentage evaluation and outputs the reading results continuously. An example is shown in Fig. 6-9.
9.
Present the bar code pattern from Fig. 6-1, Page 6-4 and monitor the reading results in the Terminal Emulator window.
The behavior of the "Result" LED also indicates the reading quality: –
LED is extinguished if reading quality is < 30 %
–
LED flashes twice per second if the reading quality is 30 % to 70 %
–
LED flashes five times per second if the reading quality is 70 % to 90 %
–
LED is lit continuously if the reading quality is > 90 %
Fig. 6-9:
6-24
CLV Setup: display of the Percentage evaluation in the Terminal Emulator
© SICK AG · Division Auto Ident · Germany · All rights reserved
8 008 568/K949/10-06-2002
Page 83
Operation
Operating instructions
Chapter 6
CLV 43x/44x Bar Code Scanner
The output format of the reading result is the same as that of the Reading mode. Fig. 6-7, Page 6-22 explains the structure and function of the reading diagnosis data. Note
Profile bar codes read by the CLV during the percentage evaluation do not cause any changes to be made to the parameter set and do not, therefore, affect the reading process either. The match code cannot be programmed (teach-in) in the Percentage evaluation mode. The code is entered on the DEVICE CONFIGURATION tab. The match code 1 can also be programmed using the teach-in method. The CLV outputs the data contents of the uncovered polling reflector with the identifier "REPO" in the Percentage evaluation mode. 6.5.3
Adjusting mode
The "Adjusting“ mode enables the center of the scan line to be optimally positioned on the bar code. Chapter 4.3.3 "Auxiliary functions for adjustment", Page 4-10 describes the procedure for going about this after the Adjusting mode has been started. The CLV does not output a reading result in this mode. The Adjusting mode can be called up by choosing VIEW in the menu bar, as a device function via TOOLS (interactively), or via the Terminal Emulator. Line scanner with oscillating mirror: In "Adjusting" mode, the CLV behaves as follows: – in "Oscillating" mode (default setting: oscillating with fixed Amplitude) switches to Oscillating mode and positions the scan line at the angle CW = 50 (corresponds to an angle of emergence under 105°). This position cannot be changed.
– in "One-shot" mode, it also positions the scan line under the angle CW = 50.
– in "Fixed Position" mode, on the other hand, the selected scan line position remains unchanged.
1.
Click in the toolbar. The Terminal Emulator window is then displayed. The CLV is in Reading mode.
2.
Click ADJUSTING MODE under DEVICE MODE. The "Device Ready" LED is extinguished. The CLV cancels the Reading mode and masks the scan line from position CP = 50 to position CP = 100.
3.
Click READING MODE to exit the Adjusting mode. The CLV returns to Reading mode. The "Device Ready" LED lights up.
6.5.4
Show CP-limits
In this mode, the CLV blanks certain parts of the scan line so that any limit values defined for the active evaluation range of the scan line can be checked directly during parameterization. The limitation of the active evaluation range shortens the evaluation time for fast applications, for example, as the evaluation routine need only take relevant areas of the scan line into account. The range is restricted by entering appropriate values for MINIMUM CODE POSITION and MAXIMUM CODE POSITION in the EDIT DISTANCE CONFIGURATIONS dialog box on the READING CONFIGURATION tab. "Show CP-limits" allows you to check whether the limitation for each active distance configuration has been adjusted to the reading distance in question for the selected focus control setting ("Christmas tree effect"). The CLV does not output a reading result.
8 008 568/K949/10-06-2002
© SICK AG · Division Auto Ident · Germany · All rights reserved
6-25
Page 84
Chapter 6
Operation
Operating instructions CLV 43x/44x Bar Code Scanner
"Show CP-limits" can be called up via VIEW in the menu bar, as a device function via TOOLS (interactively), or via the Terminal Emulator. Line scanner with oscillating mirror: The CLV behaves as follows in "Show CP-limits" mode: – in "Oscillating" mode (default setting: oscillating with fixed Amplitude) switches to Oscillating mode and positions the scan line at the angle CW = 50 (corresponds to an angle of emergence under 105°). This position cannot be changed.
– in "One-shot" mode, it also positions the scan line under the angle CW = 50.
– in "Fixed Position" mode, on the other hand, the selected scan line position remains unchanged.
The CLV masks the scan line alternately from the set value for CPmin and from the set value for CPmax. An example is shown in Fig. 6-11. The switchover is made continuously at intervals of one second. The part of the scan line that remains active for the reading procedure is the section between CPmin and CPmax. Example: Default setting: Evaluation set for the area from CPmin= 5 to CPmax= 95. The CLV masks the line from CPmin = 5 (short scan line) and from CPmax = 95 (long scan line).
"Show CP-limits"
Active
CPmax Scan line 2 area CPmin
Scan line 1
Fig. 6-10: Appearance of scan line in the "Show CP-limits" mode
Proceed as follows to check the restricted evaluation range:
6-26
1.
Click in the toolbar. The Terminal Emulator window is then displayed. The CLV is in Reading mode.
2.
In the DEVICE MODE group, click SHOW CP-LIMITS. The dialog box for the distance configuration is then displayed.
3.
Click the distance configuration for which the active evaluation range of the scan line has been restricted (DC-specific). The "Device Ready" LED is extinguished. The CLV cancels the Reading mode and blanks the scan line alternately (as described above) as of CPmin and CPmax.
4.
Check Steps 2 and 3 for each active distance configuration to determine whether the bar code is in the center of the range between the end of the shorter scan line (CPmin) and the end of the longer scan line (CPmax) or, if there are several bar codes, to determine whether the center of the field of all the codes is within the range.
5.
If necessary, correct CPmin and CPmax accordingly. Perform a download to the CLV!
© SICK AG · Division Auto Ident · Germany · All rights reserved
8 008 568/K949/10-06-2002
Page 85
Operation
Operating instructions
Chapter 6
CLV 43x/44x Bar Code Scanner
6.
Note
Click READING MODE to exit the SHOW CP-LIMITS mode. The CLV returns to Reading mode. The "Device Ready" LED lights up.
In the Reading mode, the CLV does not actually mask the scan line visually, but instead takes the values specified for the restricted evaluation range into account when the data contents are decoded. 6.5.5
Displaying and editing operating data
This function enables statistical operating data, which the CLV maintains in the form of counters during the reading procedure, to be displayed and reset. The CLV does not output a reading result in this mode. 1.
Click in the toolbar. The CLV cancels Reading mode. The "Device Ready" LED is extinguished. The OPERATING DATA dialog box appears (Fig. 6-11).
2.
After checking/resetting the desired counters, click "OK" to confirm any changes made. The CLV returns to Reading mode. The "Device Ready" LED lights up.
Fig. 6-11: CLV Setup: "Operating Data" dialog box
6.5.6
Reading diagnosis
Function of the terminal interface. In this mode, the CLV outputs the data contents of all the bar codes that were read – including those that, according to the evaluation criteria, were not read properly and were thus incorrect – together with the associated reading diagnosis data via the terminal interface. The number of bar codes output can, therefore, be higher than the number of those that were sent via the host interface in the reading result. In the default setting, this mode is selected for the terminal interface. Fig. 6-6, Page 6-21 shows the corresponding output format of the terminal interface. In the default setting, the CLV does not output any reading diagnosis data via the host interface.
8 008 568/K949/10-06-2002
© SICK AG · Division Auto Ident · Germany · All rights reserved
6-27