Page 102
Chapter 8
Troubleshooting
Operating instructions CLV 43x/44x Bar Code Scanner
8.5.2
Malfunctions in Reading mode: reading pulse errors
The "Device Ready" LED lights up. If not, see Table 8-3, Page 8-7. Malfunction
Possible cause
Remedy
• Sensor not connected or • Connect sensor to 1. Pulse mode: connected to incorrect sensor input "Sensor 1" switching input. switching input (external sensor). Check sensor wiring (Fig. 5-4, Page 5-3). The CLV cannot be pulsed: Measure output signal on – The "Laser On" LED does sensor not light up. • If sensor supplied by CLV: • Insert jumper between pin 5 – The scan line does not sensor not connected to and pin 15 appear. ground potential • Incorrect reading pulse • Check in the CLV Setup source parameterized on the program: Select the tab CLV DEVICE CONFIGURATION and click the EDIT READING TRIGGER button. Sensor input selected? (active high: reading pulse starts when power applied) • Photoelectric switch not • Align sensor. Check aligned with the reflector functioning. (photoelectric proximity switch/inductive sensor not dampened) • 2. Pulse mode: Reflector polling The CLV cannot be pulsed: • – The "Laser On" LED flickers but does not light • up constantly. – The scan line is very faint.
Incorrect reading distance (polling reflector) Incorrect reflector type used Incorrect pulsing sequence (reflector is not blocked to start the reading interval on the CLV)
• Check: reading distance of reflector in specified Reading range? • Check reflector type, Table 4-2, Page 4-13 • Check sequence: Read: 1. Block reflector, 2. Read bar code, 3. Unblock reflector.
• CLV 44x or line scanner with • Trigger mode is not suitable oscillating mirror in oscillating for these devices/modes mode used (see Chapter 4.4.3 "Installing the polling reflector", Page 4-12). Table 8-4: Troubleshooting: reading pulse errors in Reading mode
8-8
© SICK AG · Division Auto Ident · Germany · All rights reserved
8 008 568/K949/10-06-2002
Page 103
Operating instructions
Troubleshooting
Chapter 8
CLV 43x/44x Bar Code Scanner
Malfunction
Possible cause
Remedy
• Incorrect reading pulse • Check in the CLV Setup 3. Pulse mode: Serial Interface source parameterized on the program: Select the tab The CLV cannot be pulsed: CLV DEVICE CONFIGURATION and click the EDIT READING TRIGGER – The "Laser On" LED does button. not light up. In the MODE group: is serial – The scan line does not interface selected? appear. Group SERIAL INTERFACE: is trigger type correct? • The CLV is not receiving any • Check data connection to host. command strings to start the Check in the CLV Setup reading interval on the data program: Select the HOST interface INTERF. tab. In DATA FORMAT group: are the correct interface type (hardware) and data format selected? Group: INTERFACE PROTOCOL: are the correct start and stop characters selected? • Use the CLV Setup program to check the host command strings: Choose AUXILIARY INTERFACE tab. Select the MONITOR HOST INTERFACE function (see Chapter 6.5.7 "Monitor host interface", Page 6-28). Download temporarily to the CLV. 4.
CLV does not respond to an external signal that ends the reading pulse (sensor input, reflector polling, serial interface)
Incorrect end of reading pulse parameterized on the CLV
Check in the CLV Setup program: Select the DEVICE CONFIGURATION tab and click the EDIT READING TRIGGER button. END OF READING INTERVAL group: is "Generated by Trigger Source" selected?
Table 8-4: Troubleshooting: reading pulse errors in Reading mode
8 008 568/K949/10-06-2002
© SICK AG · Division Auto Ident · Germany · All rights reserved
8-9
Page 104
Chapter 8
Troubleshooting
Operating instructions CLV 43x/44x Bar Code Scanner
8.5.3
Malfunctions in Reading mode: result output errors
¾ Check whether the "Device Ready" LED illuminates. If the LED does not illuminate, follow Table 8-3, Page 8-7. For the following, the number of bar codes to be read is 1 Malfunction 1.
Possible cause
Remedy
• Read not successful, since • Synchronize reading with an The "Result" LED (default setting: "Good there was no bar code in the object in the reading field Read") does not light up at reading field during the (see Chapter 8.5.2 the end of the reading reading pulse "Malfunctions in Reading pulse. mode: reading pulse errors", Page 8-8). – The "Result 2" • Align CLV. switching output • Scan line positioned (default setting: "Good Is bar code at center of scan incorrectly Read") is not line? outputting a pulse. Check in the CLV Setup program: check reading – The CLV outputs the quality. Call up PERCENTAGE status ST=2 in the EVALUATION for this purpose reading result on the (see Chapter 6.5.2 host interface (if ST is "Percentage evaluation", enabled for the Page 6-23) separator; this is not selected in the default • Evaluation range of the scan • Check in the CLV Setup setting). program: Choose the DEVICE line is limited improperly CONFIGURATION tab, click the (CP values) DISTANCE CONFIGURATION button. Are the min. and max. code position values correct? Check with SHOW CP-LIMITS (see Chapter 6.5.4 "Show CP-limits", Page 6-25). • Bar code presented at incorrect reading distance (CLV 43x)
• Check: reading distance of bar code in specified Reading range?
• Incorrect focus position • Check in the CLV Setup selected in distance program: choose the DEVICE CONFIGURATION tab, click the configuration of the CLV 44x DISTANCE CONFIGURATION/ ASSIGNMENT TABLE button. Does the focus position match the distance of the object? • With dynamic focus control • In the CLV Setup program, (CLV 44x): check: choose the READING trigger source parameterized CONFIGURATION tab, in the incorrectly FOCUS TRIGGER SOURCE group. a) Trigger source: "Sensor 2" switching input: check functional assignment and connection of sensor (see Fig. 5-5, Page 5-8). Table 8-5: Troubleshooting: result output errors in Reading mode
8-10
© SICK AG · Division Auto Ident · Germany · All rights reserved
8 008 568/K949/10-06-2002
Page 105
Operating instructions
Troubleshooting
Chapter 8
CLV 43x/44x Bar Code Scanner
Malfunction
Possible cause
1.
• With dynamic focus control • b) Trigger source: "Serial (CLV 44x): interface": trigger source parameterized check the data connection to incorrectly the host. Use the CLV Setup program to check the host command strings: Choose – continued – AUX. INTERFACE tab. Select the MONITOR HOST INTERFACE function (see Chapter 6.5.7 "Monitor host interface", Page 6-28). Temporary download to CLV! c) Trigger source: "Timer": check switchover time. • In the CLV Setup program: • The bar code is tilted choose the CODE excessively with respect to CONFIGURATION tab, DECODER the scan line group. Choose SMART decoder (but not for Raster scanners). Download to CLV! • In the CLV Setup program: • The reading angles at which choose the CODE the bar code appears to the CONFIGURATION tab, DECODER CLV are too large group. choose Standard decoder. Download temporarily to CLV! Start PERCENTAGE EVALUATION, select distance configuration. Observe the reading quality (reading quality >70 %!). If necessary, realign CLV and/ or reconfigure distance configuration. If ok, choose SMART decoder. Download to the CLV! • Bar code is in total reflection • Optimize CLV alignment (scan line should strike the zone bar code at an angle of approx. 15°) Check in the CLV Setup program: check reading quality. Start PERCENTAGE EVALUATION (see Chapter 6.5.2 "Percentage evaluation", Page 6-23).
The "Result" LED (default setting: "Good Read") does not light up at the end of the reading pulse. – continued –
Remedy
Table 8-5: Troubleshooting: result output errors in Reading mode
8 008 568/K949/10-06-2002
© SICK AG · Division Auto Ident · Germany · All rights reserved
8-11
Page 106
Chapter 8
Troubleshooting
Operating instructions CLV 43x/44x Bar Code Scanner
Malfunction
Possible cause
Remedy
1.
• Evaluation criteria for bar code incorrect
• In the CLV Setup program: choose the CODE CONFIGURATION tab, CODES group. Enable all code types (except Pharmacode), set code lengths to FREE. Download temporarily to CLV! Start PERCENTAGE EVALUATION. Code type and length are displayed in the reading result. Enable recorded code type in the CODES group and disable all other types. Enter the code length under FIXED on the code type tab. Download to CLV! • Check: Are sufficient blank zones present? Is the print contrast adequate? Are the specified print tolerances exceeded? In the CLV Setup program: choose the READING CONFIGURATION tab and find the SEGMENTATION group: Is "Start/Stop" selected? Perform test read with a reference code in good condition.
The "Result" LED (default setting: "Good Read") does not light up at the end of the reading pulse. – continued –
• Bar code quality not adequate
2.
The CLV is not transferring • Reading pulse is not any reading results to the functioning correctly host. • Wiring fault in data connection • Voltage level incorrect • Host interface in CLV parameterized incorrectly
3.
The CLV transfers the The CLV has diagnosed status ST=3 to the host in a device error in the self-test. the reading result. (if ST is enabled for the separator; this is not selected by default)
• See Chapter 8.5.2 "Malfunctions in Reading mode: reading pulse errors", Page 8-8 • Check wiring with Fig. 5-2, Page 5-5. • Measure voltages. • Check in the CLV Setup program: choose HOST INTERFACE tab, DATA FORMAT group: Are the correct interface type (hardware) and data format selected? Check settings in INTERFACE PROTOCOL group. Switch the CLV off and on again. Does the "Device Ready" LED light up? If not, contact the SICK Service department.
Table 8-5: Troubleshooting: result output errors in Reading mode
8-12
© SICK AG · Division Auto Ident · Germany · All rights reserved
8 008 568/K949/10-06-2002
Page 107
Operating instructions
Troubleshooting
Chapter 8
CLV 43x/44x Bar Code Scanner
Malfunction
Possible cause
4.
• The data format on the host interface is parameterized incorrectly in the CLV
The data content of the bar code output by the CLV is incorrect or incomplete.
Remedy
• Check in the CLV Setup program: Select the HOST INTERFACE tab, DATA FORMAT group. Are the values correct? • The CLV suppresses the last • Check in the CLV Setup character in the bar code. program: Select the CODE CONFIGURATION tab. Click the EDIT CODES button. Choose the tab for the relevant code. Is Transmit Check Digit activated? Change if necessary. Download to CLV!
Table 8-5: Troubleshooting: result output errors in Reading mode
8.5.4
Malfunctions in Reading mode: errors when outputting the result status
The "Device Ready" LED lights up. If not, see Table 8-3, Page 8-7. Malfunction
Possible cause
Remedy
1.
The "Result 1" (default setting: "Device Ready") and "Result 2" (default setting: "Good Read") switching outputs are not outputting any pulses.
• The event of the assigned function for outputting the result status does not occur during the reading process • Incorrect switching mode parameterized in CLV
• Not applicable
The beeper is not confirming the output of the reading result (default setting: "Good Read")
Beeper deactivated
Check in the CLV Setup program: choose the DEVICE CONFIGURATION tab and find the BEEPER group: LOW or HIGH selected?
2.
• Check in the CLV Setup program: choose the DEVICE CONFIGURATION tab. Click the EDIT RESULT OUTPUTS button. Are the outputs set to "Invert Output"? Change if necessary. Download to CLV!
Table 8-6: Troubleshooting: errors in the result status output in Reading mode
8 008 568/K949/10-06-2002
© SICK AG · Division Auto Ident · Germany · All rights reserved
8-13
Page 108
Chapter 8
Troubleshooting
Operating instructions CLV 43x/44x Bar Code Scanner
8.5.5
Malfunctions in Reading mode: oscillating mirror errors
The "Device Ready" LED lights up. If not, see Table 8-3, Page 8-7. Malfunction
Possible cause
Remedy
1.
The oscillating mirror does not move.
• Incorrect operating mode set on the CLV
• Check in the CLV Setup program: choose the OSCILLATING MIRROR tab and the OSCILLATING MIRROR group. Is OSCILLATING MODE or OSCILLATING WITH VARIABLE AMPLITUDE selected?
2.
The oscillating mirror oscillates with maximum deflection (40 CW), even though a variable amplitude of e.g. 10 CW is set in distance configuration 1
• OSCILLATING MODE set on the CLV by mistake
• From the OSCILLATING MIRROR tab, choose OSCILLATING WITH VARIABLE AMPLITUDE. Download to the CLV! • Check with user interface of CLV Setup: choose DEVICE CONFIGURATION tab and click the DISTANCE CONFIGURATION button. Is the amplitude value set in the correct distance configuration (here: no. 1)? • Check in the CLV Setup program: Choose DEVICE CONFIGURATION tab. Assignment Sensor 2: is dynamic focus control selected? Connect sensor to "Sensor 2" switching input. Check sensor wiring (see Fig. 5-5, Page 5-8). Measure output signal on sensor
• The oscillating amplitude is paramterized in the wrong distance configuration (here: no. 2)
• Distance configuration not switched over
3.
One-shot: The one-shot function cannot be triggered (sensor correctly connected to the "Sensor 2" switching input)
• Trigger source incorrectly parameterized and/or switching input Sensor 2: function is not assigned.
• Check in the CLV Setup program: choose the OSCILLATING MIRROR tab. Trigger mode ok? Choose DEVICE CONFIGURATION tab. Assignment Sensor 2: is trigger one-shot selected?
Table 8-7: Troubleshooting: oscillating mirror errors in Reading mode
8-14
© SICK AG · Division Auto Ident · Germany · All rights reserved
8 008 568/K949/10-06-2002
Page 109
Operating instructions
Troubleshooting
Chapter 8
CLV 43x/44x Bar Code Scanner
8.5.6
Malfunctions: configuration errors (parameterization)
Malfunction 1.
Possible cause
• CLV not in "AutoSetup" AutoSetup: the CLV does not read the mode. presented, applicationspecific bar code (no confirmation from beeper).
•
•
•
• 2.
Remedy
• Check: Does the "Device Ready" LED light up? If so, the CLV is in "Reading" mode again. In CLV Setup program: restart AutoSetup from the VIEW menu. • Switch the CLV off and on If AutoSetup is started with again. profile bar code no. 10: Present profile bar code no. wait time of 5 s after power10 within 5 s. up has been exceeded Then present the applicationspecific bar code. • Check: Is the reading Bar code presented at distance of the bar code incorrect reading distance within the specified reading area? Bar code is in total reflection • Optimize bar code alignment zone (scan line should strike the bar code at an angle of approx. 15°) • (see Malfunction 1, Bar code quality not adequate Table 8-5, Page 8-10)
• Wait time of 5 s after power- • Switch the CLV off and on Profile programming: CLV does not read the up has been exceeded again. presented profile bar code Present profile bar code (no confirmation from within 5 s. beeper). • Wait time of 10 s after the • Once the first profile bar code first profile bar code was has been read successfully, presented has been present the next bar code exceeded within 10 s etc. • In Reading mode: CLV not • Clock the CLV accordingly pulsed and present the first profile bar code. Present the next bar code within 10 s etc.
Table 8-8: Troubleshooting: configuration errors (parameterization)
8 008 568/K949/10-06-2002
© SICK AG · Division Auto Ident · Germany · All rights reserved
8-15
Page 110
Chapter 8
Troubleshooting
Operating instructions CLV 43x/44x Bar Code Scanner
8.6
SICK support
If a system error occurs repeatedly ("CLV SYS-Failure: xxx", xxx = 000 to 215) or if you cannot correct an error using the above measures, the CLV may be defective. The CLV does not have any system components whose functionality can be restored by the user in person after a failure. Please contact our local SICK office or subsidary: •
The telephone and fax numbers are listed on the back page of this manual.
¾ Do not send the device to the SICK service without first contacting us.
8-16
© SICK AG · Division Auto Ident · Germany · All rights reserved