Page 23

1 Overview & Maintenance

1 Overview & Maintenance

CHAPTER 1

This chapter provides you with an overview of a typical CiMAX 78xx application product specifications.

Overview Typical Physical Setup CiMAX 78xx scanners may be used with other equipment including photoeyes, tachometer, Standard Interface Unit, and a Hex Interface Unit. Figure 1–1 shows the scanners in a typical scan tunnel configuration with accessory components. However, your application may not have the same requirements. Specific cable connections, pinouts and wiring diagrams are provided in Chapter 3, “Controls, Connectors, & Indicators”. FIGURE 1–1. Typical Configuration

Rev H, February 2002

CiMAX 78xx Technical Reference Manual

1-1

Page 24

Chapter

1

Overview & Maintenance

CiMAX 7800 Laser Scanner The CiMAX 7800 is an intelligent fixed-position laser scanner with high reading rates, local and network processing and control, user C programmability, and optional automatic focusing. CiMAX 78xx scanners are often used in Scan Tunnel applications to scan the leading and trailing sides of boxes. The CiMAX 7800 has eight inputs and eight outputs, used for presence and height detection, tachometer inputs, timing, diverter control, and alarms. The Standard Interface Unit provides power to one CiMAX 7800 scanner or two, when operated in the master/slave mode. The Hex Interface Unit can provide power and communications for up to six scanners is also available for use in applications such as Scan Tunnels. The CiMAX 7800 dual processor architecture uses an independent DSP (Digital Signal Processor) to translate bar code data for the 32-bit main processor. The scanner can be configured with up to one Mbyte of non-volatile program and data memory.

CiMAX 7850 Laser Scanner The CiMAX 7850 is electrically and operationally identical to the CiMAX 7800 with the exception of Auto focusing, which is not available. The case of the 7850 is physically longer than the 7800 to accommodate a 90° deflection mirror, which permits the laser beam to output from the side instead of the front of the case. It is often used to scan the bottom of boxes as they pass over a break in the conveyor.

CiMAX 7855 Laser Scanner The CiMAX 7855 emits a horizontal beam that is swept back and forth in a sweep raster-scanning pattern, as shown in Figure 1–2. FIGURE 1–2. Sweep Raster Scan Pattern of the CiMAX 7855

Scan Height

Sweep Height

1-2

CiMAX 78xx Technical Reference Manual

Rev H, February 2002

Page 25

The CiMAX 7855 sweep raster scanner provides a moving, visible red laser beam that sweeps repeatedly across a barcode in a regular sinusoidal wave pattern. The CiMAX 7855 has the same housing as the CiMAX 7850, but the laser beam is deflected in a sweep raster pattern for increased coverage. Refer to Appendix C, “Dimension Diagrams” for mechanical drawings of the CiMAX 7800 and the CiMAX 7850/7855. Except where specifically noted, all information in this manual applies to CiMAX 7800/7850/7855 scanners.

Keysheet The keysheet specifies the details of your scanner setup. It is based on information you provided to SICK Auto Ident, Inc. about your scanner application. The keysheet has been carefully developed from the results of a questionnaire you filled out about your conveyor system. The information in the keysheet customizes the CiMAX 78xx Scanner hardware and software setup for your site. Do not deviate from the keysheet or otherwise change the configuration without consulting SICK Auto Ident, Inc.

Software Updates Software updates from SICK Auto Ident, Inc. can include changes and improvements in the following: •

Operating System

•

Code for Gap Tracking

•

CIX Technology

•

Network

•

File Memory

•

C code

•

Decoded Symbologies

Software updates will be provided to you by SICK Auto Ident, Inc., as your application requires. These updates can be uploaded into your scanner from your PC, with the software available from SICK Auto Ident, Inc. The scanner uses flash memory to allow complete re-programming in the field.

Rev H, February 2002

CiMAX 78xx Technical Reference Manual

1-3

1 Overview & Maintenance

Overview

Page 26

Chapter

1

Overview & Maintenance

Specifications Scanner Configuration Depth of Field (DOF)/Diodes •

Full depth of field - Auto focus

•

Reduced depth of field - Fixed focus

Memory •

256K (approx. 100K for user C programs and data)

•

1M (approx. 800K for user C programs and data)

Network •

Without

•

Ethernet 10 base 2

•

Ethernet 10 base T

•

SDS

•

DeviceNet

Standard Interface Unit (for I/O connections) •

Standard Interface Unit and cable

•

Standard Interface Unit and cable, plus Opto 22 I/O modules

•

Standard Interface Unit and cable, plus Programmable Interface Controller

Physical For mechanical drawings with dimensions, Refer to Appendix C, “Dimension Diagrams”.

CiMAX 7800 •

13.3 x 6.5 x 4.69 inches (338 x 165 x 119 mm)

•

13 pounds (5.9 kilograms)

CiMAX 7850/7855

1-4

•

14.38 x 6.5 x 4.9 inches (365 x 165 x 124 mm)

•

14 pounds (6.4 kilograms)

CiMAX 78xx Technical Reference Manual

Rev H, February 2002

Page 27

Method of Illumination Laser diodes, wavelength 635-685 nanometers (visible red light)

Scan Rates •

Application dependent - Refer to your keysheet

•

300-750 scans per second

Application Performance Specifications •

32" x 32" x 60" bar-coded boxes

•

Capable of reading 10 mil barcodes, 1" high, at distances of 18-50" (must use the laser autofocusing system)

•

300-scans/second min., 750-scans/sec max.

•

Laser focusing system is standard for tunnel applications, fixed focus is optional.

•

24" to 50" typical reading range for tunnel application

•

Capable of 72" max range (0.020" X-dimension barcode in non-tunnel application, using special lasers)

•

6" minimum gap between boxes

Power Input - Power required from external Interface Unit. Regulated +12 VDC, 2A max., +5 VDC, 1A max.

Construction Single integrated package consisting of aluminum enclosure fully gasketed and mounted on 1/2-inch (12.7 mm) aluminum base plate.

Environmental •

NEMA 12 (IP 65) dust-tight and drip-proof

•

Operating Temperature - 32° to 122° F. (0° to 50° C)

•

Humidity - 5% to 95% non-condensing

LED Status Indicators Six LEDs on a single display monitor operations and communications

Communications Four independent communications ports •

1 asynchronous serial Host port (RS-232 or RS-422)

•

1 asynchronous serial Terminal port (RS-232)

Rev H, February 2002

CiMAX 78xx Technical Reference Manual

1 Overview & Maintenance

Specifications

1-5

Page 28

Chapter

1

Overview & Maintenance

•

1 RS-485 LAN port with Starnode protocol

•

1 Network port (optional)

Inputs •

Fifteen total, active low when <1.0 VDC –

•

Eight standard inputs –

– •

Maximum input 30 VDC intermittent, 27 VDC continuous

Normal default input assignments -

Two presence (Inzone, Outzone)

-

One tachometer - 0.2 inches per pulse minimum resolution at up to 1000 pulses per second, max

-

Up to five height-sensing inputs

Inputs not used for presence, tachometer and height-sensing are available for general purpose use under user C program control

Seven optional inputs - For use only for height-sensing with Programmable Interface Controller

Outputs •

Eight total, open collector solid state - 30 VDC at 150 mA, max

•

Normal default output assignments –

Output 1 - No Read

–

Output 2 - Match

–

Output 3 - No Match

Standard Interface Unit Physical Refer to Appendix C, “Dimension Diagrams” for more information. •

13.25 H x 13.00 W x 2.98 D inches (337 x 330 x 76 mm)

•

13.5 lbs (6.1 kg) with attached cable

•

Scanner-interface cable length - 6.5 feet (2 meters)

AC Power 115/230 ±10% VAC @ 0.8/0.4A, 50/60 Hz.

1-6

CiMAX 78xx Technical Reference Manual

Rev H, February 2002

Page 29

Inputs Standard - Eight solid state, active low when <1.0 VDC, 30 VDC max, 27 VDC continuous (These inputs are extensions of the eight solid state scanner inputs)

Outputs Standard - Eight open collector solid state, 30 VDC at 150 mA, max. (These outputs are extensions of the eight solid-state scanner outputs)

Optional Solid-State Input/Output Modules Optically isolated Opto–22 style modules may be installed as inputs or outputs. They are controlled by standard input/output signals. •

•

Input Modules –

Type - AC Input

–

Voltage Range - 90-140 VAC -

6 mA at minimum voltage

-

10 mA at max. voltage

Output Modules –

Type - AC Output

–

Load Current Over Load Voltage Range - 0.02 - 3 A at 24 - 140 VAC

Electro-Mechanical Output Relay One Form C (SPDT) relay operated by scanner output eight.

Hex Interface Unit Physical For dimensions, refer to Appendix C, “Dimension Diagrams”. •

21 H x 18.5 W x 4.25 D inches (533 x 470 x 108 mm)

•

50.5 lbs (22.9 kg) with attached cable

•

Scanner-interface cable length - 6.5 feet (2 meters)

AC Power 115/230 ±10% VAC @ 3.0/1.5A, 50/60 Hz.

Inputs Standard - Eight solid state, active low when <1.0 VDC, 30 VDC max, 27 VDC continuous (These inputs are extensions of the eight solid state scanner inputs)

Rev H, February 2002

CiMAX 78xx Technical Reference Manual

1-7

1 Overview & Maintenance

Specifications

Page 30

Chapter

1

Overview & Maintenance

Outputs •

Standard - Eight open collector solid state, 30 VDC at 150 mA, max. (These outputs are extensions of the eight solid-state scanner outputs).

Optional Solid-State Input/Output Modules Optically isolated Opto 22 style modules may be installed as inputs or outputs. They are controlled by standard input/output signals. •

•

Input Modules –

Type - AC Input

–

Voltage Range - 90-140 VAC -

6 mA at minimum voltage

-

10 mA at max. voltage

Output Modules –

Type - AC Output

–

Load Current Over Load Voltage Range - 0.02 - 3 A at 24 - 140 VAC

Electro-Mechanical Output Relay One Form C (SPDT) relay operated by scanner output eight.

Maintenance The scanner requires no special preventive maintenance when operated in an environment free from extremes of temperature, humidity, shock, and vibration. The following tasks should be performed once a month to keep the scanner clean and to inspect it for mechanical damage. 1.

Remove DC power and disconnect all cables before cleaning.

2.

Clean dirt and dust from the scanner's window and from the LED display, using a soft, lint-free cloth and a non-abrasive liquid cleaner. DO NOT use an abrasive cleaner.

3.

Check all cables for signs of abrasion.

4.

Check that all cable connections are secure after maintenance.

Caution: The scanner’s internal components do NOT require preventive maintenance. Opening the scanner with power applied can expose the operator to electrical and mechanical hazards, which can cause bodily injury. If internal maintenance is required, return the scanner to SICK Auto Ident, Inc. for service.

1-8

CiMAX 78xx Technical Reference Manual

Rev H, February 2002