The text of a spec sheet · part 12 of 15
Product Catalog: Automatic Identification Solutions, pages 111 to 120
Pages 111 to 120 of 145
The original document is the PDF (2.6 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the RVSI CiMatrix 7555A, Sick 7555A and Siemens 7555A
Page 111
The LMS 211 is an outdoor system that has three
System (LMS) that has high measurement resolution, internally programmable monitoring fields assigned to contact-free measurement, a high scanning frequency three switching outputs. The measurement data is
LMS 211
The LMS 200/291 is an indoor Laser Measurement and transfer of measurement data in real time.
Pgs. 114-117
Pgs. 110-113 available in real time and can be used for further processing or control tasks.
The LMS 220/221 is an outdoor system that has three internally programmable monitoring fields assigned to three switching outputs. It is a contact-free device with a high scanning frequency.
laser measurement systems (LMS)
Pgs. 118-121
LMS 220/221
LMS 200/291
LASER MEASUREMENT SYSTEMS www.sickusa.com
109
800.325.7425
Page 112
LMS 200/291 FEATURES • 180° coverage • Indoor applications • Long range- up to 262 ft (80 m) • Contact-free measurement • Target objects require no reflectors or markings • High scanning frequency (up to 75 Hz) • Transfer of measurement data in real time • Active system, no illumination of target objects necessary • Measurements possible over long distance • Compact device construction • Three internally programmable monitoring fields assigned to three switching outputs
Model
Max. Scanning Angle
Resolution / Typical Measurement Accuracy
Range with 10% Reflectivity
LMS 200
180°
± 0.6 in / 0…26 ft (± 15 mm / 1…8 m)
LMS 291
180°
± 1.3 in / 13…65 ft (± 35 mm / 4…20 m)
www.sickusa.com
110
Heating
Fog Correction
32.8 ft (10 m)
no no
98.4 ft (30 m)
no yes
800.325.7425
Page 113
LMS 200/291 REFLECTIVITY RANGES Range in feet (m)
600
LMS 200
100
Material
Reflectivity
Cardboard, matte black Cardboard, grey Wood (raw pine, dirty) PVC, grey Paper, matte white Aluminum, anodized, black Steel, rust-free shiny Steel, very shiny Reflectors
10% 20% 40% 50% 80% 110…150% 120…150% 140…200% > 2000%
Reflectivity %
10
1
0.3 (0.1)
3.3 (1.0)
33 (10)
197 (60)
laser measurement systems (LMS)
Range
100
LMS 291 90 range with good visibility range with pollution (warning signal active)
80 70 60 Reflectivity 50 % 40 30 20 10 0 0
16 (5)
33 (10)
49 (15)
66 (20)
82 (25)
98 (30)
115 (35)
131 (40)
148 (45)
164 (50)
180 (55)
197 (60)
213 (65)
230 (70)
246 (75)
262 (80)
Range www.sickusa.com
111
800.325.7425
Page 114
LMS 200/291 TECHNICAL SPECIFICATIONS LMS 200 General Range Angular Resolution Response Time Measurement Resolution System Error (environmental conditions: good visibility, Ta = 23°C (73°F), reflectivity 10%…10,000%) Statistical Error, Standard Deviation (1 sigma) Electrical Data Interface Transfer Rate Switching Outputs, Standard Variants Supply Voltage (scanner-electronics) Power Uptake Electrical Protection Class Interference Resistance Ambient Temperature (Operating / Storage) Mechanical Enclosure Rating Weight Dimensions Vibration Fatigue Limit
LMS 291
Maximum 262.5 ft (80 m) 0.25°/0.5°/1.0° (selectable) 53 ms/26 ms/13 ms 0.4 in (10 mm) Typ. ± 15 mm (mm-mode), range 1…8 m (3.2…26.2 ft) Typ. ± 4 cm (cm-mode), range 1…20 m (3.2…65.6 ft) Typ. 5 mm (at range ≤ 8 m / ≥ 10% reflectivity / ≤ 5 kLux)
Typ. ± 60 mm (mm-mode), range 1…4 m (3.2…13.1 ft) Typ. ± 35 mm (mm-mode), range 4…20 m (13.1…65.6 ft) Typ. 10 mm (at range 1…20 m / ≥ 10% reflectivity / ≤ 5 kLux)
RS 232/RS 422 (configurable) 9.6/19.2/38.4/500 kBd 3 x PNP; typ. 24 V DC; OUT A, OUT B maximum 250 mA, OUT C maximum 100 mA 24 V DC ± 15% (maximum 500 mV ripple), current requirements maximum 1.8 A (including output load) Approx. 20 W (without upload) Safety insulated, protection class 2 According to IEC 801, part 2-4; EN 50081-1/50082-2 32°…122°F (0…50°C) / -22°…158°F (-30°…70°C) IP 65 Approx. 10.1 lb (4.5 kg) 7.3 x 6.1 x 8.3 in (185 x 156 x 210 mm); with cables: 7.3 x 6.1 x 10.4 in (185 x 156 x 265 mm) According to IEC 68 part 206, table 2c, frequency range 10…150 Hz, amplitude 0.35 mm or 5 g single impact IEC 68 part 2-27, table 2, 15 g/11 ms permanent vibration IEC 68 part 2-29, 10 g/16 ms Shock absorbers are recommended for heavy vibration and impact demands (e.g. AGV applications).
MODELS AND PART NUMBERS LMS 200
LMS 291
Model
LMS 200-30106
LMS 291-S05
Part Number
1 015 850
1 018 028 www.sickusa.com
112
800.325.7425
Page 115
LMS 200/291 DIMENSIONAL DRAWINGS Dimensions in inches (mm) 5.7 (145)
0.5 (13.5) 5.4 (136.8)
M8x9
0.8 (20.5)
3.1 (78.5)
M6x8 2.0 (50)
2.1 (53.2)
1.5 (38)
X 0.9 (23 5) (23.5)
1.3 (32.5)
1.8 (45)
6.1 (156)
3.7 (93)
2.7 (69.5)
Plug-in clearance approx. 10.4 (265)
1.2 (31.7)
1.8 (45)
2.5 (63)
7.3 (185)
8.3 (210)
2.3 (59)
4.6 (118)
0.7 (18.5)
0.5 (12) 1.3 (33)
3.1 (77.5) 6.1 (155)
red yellow green www.sickusa.com
113
800.325.7425 laser measurement systems (LMS)
4.7 (120)
Page 116
LMS 211 FEATURES • 100° coverage • Outdoor applications • Integrated heating and fog correction • Heated front window • Contact-free measurement • Target objects require no reflectors or markings • Integrated lens shutter • IP 67 rating • Active system, no illumination of target objects necessary • Measurements possible over long distances • Three internally programmable monitoring fields assigned to three switching outputs
Model
Max. Scanning Angle
Resolution / Typical Measurement Accuracy
Range with 10% Reflectivity
LMS 211
100°
± 1.3 in / 13…65 ft (± 35 mm / 4…20 m)
98.4 ft (30 m)
www.sickusa.com
114
Heating
Fog Correction yes yes
800.325.7425
Page 117
LMS 211 REFLECTIVITY RANGES Range in feet (m)
100 M
LMS 211 90
C C W P P A S S R range with good visibility range with pollution (warning signal active)
80 70 60 Reflectivity 50 % 40 30 20 10 0 0
16 (5)
33 (10)
49 (15)
66 (20)
98 (30)
82 (25)
115 (35)
131 (40)
148 (45)
164 (50)
180 (55)
197 (60)
213 (65)
230 (70)
246 (75)
262 (80)
Material
Reflectivity
Cardboard, matte black Cardboard, grey Wood (raw pine, dirty) PVC, grey Paper, matte white Aluminum, anodized, black Steel, rust-free shiny Steel, very shiny Reflectors
10% 20% 40% 50% 80% 110…150% 120…150% 140…200% > 2000% www.sickusa.com laser measurement systems (LMS)
Range
115
800.325.7425
Page 118
LMS 211 TECHNICAL SPECIFICATIONS LMS 211 General Range Angular Resolution Response Time Measurement Resolution System Error (environmental conditions: good visibility, Ta = 23°C (73°F), reflectivity 10%…10,000%) Statistical Error, Standard Deviation (1 sigma) Electrical Data Interface Transfer Rate Switching Outputs, Standard Variants Switching Outputs, Relay Variants
Supply Voltage (scanner-electronics) Supply Voltage (heating) Power Uptake Electrical Protection Class Interference Resistance Ambient Temperature (Operating / Storage) Mechanical Enclosure Rating Weight Dimensions Vibration Fatigue Limit
Maximum 262.5 ft (80 m) 0.25°/0.5°/1.0° (selectable) 53 ms/26 ms/13 ms 0.4 in (10 mm) Typ. ± 60 mm (mm-mode), range 1…4 m (3.2…13.1 ft) Typ. ± 35 mm (mm-mode), range 4…20 m (13.1…65.6 ft) Typ. 10 mm (at range 1…20 m / ≥ 10% reflectivity / ≤ 5 kLux) RS 232/RS 422 (configurable) 9.6/19.2/38.4/500 kBd 3 x PNP; typ. 24 V DC; OUT A, OUT B maximum 250 mA, OUT C maximum 100 mA OUT A, OUT B (relay) maximum switching voltage 48 V DC/26 V AC (protected low voltage, safe isolation from mains) maximum switching current 0.7 A; maximum switching power 30 W OUT C/weak (PNP) typical 24 V DC, maximum 100 mA 24 V DC ± 15% (maximum 500 mV ripple), current requirements maximum 1.8 A (including output load) 24 V DC (maximum 6 V ripple); current requirements maximum 6 A (cyclic) Approx. 20 W (without output load), plus heating with approx. 120 W Safety insulated, protection class 2 According to IEC 801, part 2-4; EN 50081-1/50082-2 -22…122°F (-30…50°C) (warming-up time approx. 120 min at Tmin) / -22…158°F (-30…70°C) IP 67 Approx. 19.8 lb (9 kg) 13.9 x 5.4 x 10.1 in (352 x 136 x 257 mm) According to IEC 68 part 206, table 2c, frequency range 10…150 Hz, amplitude 0.35 mm or 5 g single impact IEC 68 part 2-27, table 2, 15 g/11 ms permanent vibration IEC 68 part 2-29, 10 g/16 ms Shock absorbers are recommended for heavy vibration and impact demands (e.g. AGV applications).
MODELS AND PART NUMBERS LMS 211 Model
LMS 211-30206
Part Number
1 018 023 www.sickusa.com
116
800.325.7425
Page 119
LMS 211 DIMENSIONAL DRAWINGS Dimensions in inches (mm)
13.8 (175)
13.8 (351)
3 x PG11 for cable dia 0.2…0.5 (5…12)
M8 - 9 deep (4x)
0.2 (4)
0.6 (14)
0.2 (4)
10.4 (265)
4.9 (125)
center of light exit
2.0 (50)
3.9 (98)
2.9 (73)
2.8 (70) 4.4 (113)
3.24 (82.5)
3.21 (81.5)
3.24 (82.5)
2.0 (52)
4.9 (125) space required for plug approx. 2.6 (65) 7.5 (190) 1.8 (46)
0.8 (20.5)
center of rotating mirror wheel 3.1 (79.5)
2.1 (53)
M5 - 10 deep (8x) for mounting a sunshade sheet or something similar. Not to be used for mounting device.
0.8 (20.5)
0.5 (12) 4.4 (111)
8.0 (202)
Replaceable drying agent cartridge www.sickusa.com
117
800.325.7425 laser measurement systems (LMS)
3.1 (79.5)
Page 120
LMS 220/221 FEATURES • 180° coverage • Outdoor applications • Integrated heating and fog correction (LMS 221) • Contact-free measurement • Target objects require no reflectors or markings • High scanning frequency (up to 75 Hz) • Active system, no illumination of target objects necessary • Three internally programmable monitoring fields assigned to three switching outputs • IP 67 rating • Measurements possible over long distance
Model
Max. Scanning Angle
Resolution / Typical Measurement Accuracy
Range with 10% Reflectivity
LMS 220
180°
± 0.6 in / 0…26 ft (± 15 mm / 1…8 m)
LMS 221
180°
± 1.3 in / 13…65 ft (± 35 mm / 4…20 m)
www.sickusa.com
118
Heating
Fog Correction
32.8 ft (10 m)
yes no
98.4 ft (30 m)
yes yes
800.325.7425