The text of a manual · part 6 of 9
Laser Inspector Model L1000 Operator's Guide, pages 46 to 54
Pages 46 to 54 of 81
The original document is the PDF (324 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the RJS Inspector L1000
Page 46
Appendix C
Operator’s Guide
Appendix C (Battery Displays) Battery Displays If the “Low Battery” condition displays, there is still power left in the battery to advance to the next screen or even do a scan. Low Battery
If the “Replace Battery” condition displays, batteries should be replaced immediately. The unit will not operate properly in this condition. Replace
RJS, Minneapolis, MN
Battery
40
002-5568
Page 47
Operator’s Guide
Appendix D
Appendix D (Magnifications) UPC/EAN Magnifications & Bar Width Deviations UPC and EAN symbols have fixed lengths and formats; therefore, the only way to change their sizes is to magnify them. Specifications relative to bar/space tolerances are published for 80% to 200% magnifications. While the Laser Inspector does not measure the bars and spaces to derive a magnification, it does determine the relative sizes of the elements and therefore the bar width deviations. When UPC and EAN symbols are analyzed, the approximate symbol magnification must be known in order to most accurately determine if the symbol is within tolerance. For example, if a range of 90 - 115% magnification is selected and a 200% symbol is analyzed, there will be a greater chance of a warning message for the symbol (despite its being within specification) because of the stricter tolerances of a smaller symbol. Conversely, if a range of 151% - 200% magnification is selected and a 100% symbol is analyzed, there will be a greater chance of an acceptance message for the symbol (despite its possibly not being within specification) because of the more liberal tolerances of a larger symbol.
002-5568
41
RJS, Minneapolis, MN
Page 48
Appendix E
Operator’s Guide
Appendix E (Print Functions) Print Functions Scanned data may be printed if the Laser Inspector is connected to a printer with a serial interface cable. Press the Print button at any time to display “Printout Type” on the upper row of the display. The lower row will contain one of two options that are scrolled with the Select button. With the selected option chosen, press either Enter or Print to start printing. (The choice is saved in non-volatile memory so that printing can be halted by pressing Select and Enter at the same time, until the Main Menu displays.)
Printout Options Analysis This option prints the analysis data for the last symbol scanned. This option can also be used to print each individual symbol in the multiple scan mode prior to the last scan being completed. Storage This option prints all analysis data stored in the buffer. The last barcode that was scanned is printed first. When printing the buffer in multiple scan mode, don’t initiate printing before all scans of the current analysis are complete, otherwise, some completed scans could be lost.
RJS, Minneapolis, MN
42
002-5568
Page 49
Appendix E
Operator’s Guide
Figure E-1 (Continuous scan)
Continuous was selected During the time the trigger was depressed, 17 reads were attempted and 16 of those were good
Laser Inspector L1000 Rev. X Cont. Scan Analysis ANSI 3of9 Acceptable *P0192837465* #Decodes 016/017 %Decodes 094% Ratio: 3.0 D/bility .88 A -100% Tolerance. +100% ---------------+A++++++
Figure E-2 (Multi-Scan)
4 scans were selected
The results represents an average of the 4
Laser Inspector L1000 Rev. X 04-Scan Avs Analysis ANSI 3of9 Acceptable *P0192837465* Ratio: 3.0 D/bility .89 A -100% Tolerance. +100% ---------------+A++++++
002-5568
43
RJS, Minneapolis, MN
Page 50
Appendix F
Operator’s Guide
Appendix F (Symbology Analysis) Symbology Analysis Parameters Table F-1 shows error messages that will be displayed for each parameter type checked by the Laser Inspector. Table F-1 (Parameter/Error Message) Parameter
Data Analysis Message
Ratio Inter-Character Gap (ICG) Data Character Mod Check Digits Bar Width Deviation Range Bar Width Deviation Ave. Addendum Parity (UPC/EAN) ANSI Decodability (if enabled) Object in Quiet Zone
Warning Ratio Invalid Format Invalid format Bad Mod Check Warning Wide (or narrow) Rejected Wide (or narrow) Invalid Format
RJS, Minneapolis, MN
44
Warn D/bility (DCD, in initial Pass/Fail screen) Warning QZ/SS
002-5568
Page 51
Operator’s Guide
Appendix F
Table F-2, (Parameters Checked for Each Symbology)
Symbology
Ratio
ICG
AIAG B-1 AIAG B-3/4/5
2.2-3.2
.5X-8X
LOGMARS ANSI 3 of 9 3 of 9 w/43
2.8-3.2 2.2-3.0 2.2-3.0 2.2-3.0
.5X-8X .5X-8X .5X-8X .5X-8X
HIBC 3 of 9
2.2-3.0
.5X-8X
ANSI 2 of 5 Case Code
2.2-3.0 2.3-2.9
N/A N/A
Code 128 128 Case Code
N/A N/A
N/A N?A
UPC/EAN
N/A
N/A
Codabar Variant Code 93
2.2-3.0
.5X-8X
N/A
N/A
002-5568
45
Data Character STD CODE 39 $/+% Not Allowed STD CODE 39 STD CODE 39 STD CODE 39 4 CHARS Min STD CODE 39 Min 2 CHARS 1ST. = "+" N/A 3 Data Chars Min. N/A 16 Data Char. Format Check N/A
STD CODABAR STD CODE 93
Mod Check N/A
Tolerance
N/A N/A N/A MOD 43
((12R-8)/81)X ((12R-8)/81)X ((12R-8)/81)X ((12R-8)/81)X
MOD 43
((12R-8)/81)X
N/A MOD 10
((18R-21)/80)X ((18R-21)/80)X
MOD 103 Mod 10 Mod 103 MOD 10 See Note 3 N/A
.35X .35X
C&K
.35X
((12R-8)/81)X
See Note 5
((5R-8)/20)X
RJS, Minneapolis, MN
Page 52
Appendix F
Operator’s Guide
NOTES: 1. X = X dimension 2. Tolerance is expressed as a fraction of the X dimension R = Ratio in the calculations 3. UPC/EAN tolerances: 80 - 89% = .14X 90 - 115% = .30X 116 - 150% = .34X 151 - 200% = .38X 4. See Appendix I for Quiet Zone Analysis descriptions. 5. UPC-A symbols with a number system character value of 2 and EAN-13 symbols with a prefix of 20 contain a random weight check digit in addition to the normal Mod 10 check digit. This extra digit is automatically analyzed and displayed in the Mod Check Data Analysis screen as shown below: Modck: 1 5 PASS Expect: 1 5 The 1 is the random weight check digit and the 5 is the Mod 10 check digit. The symbology specifications allow the check digit to have a value of zero in cases where it is not used In cases where the random weight check digit is zero, when another value is expected, a Bad Mod Check Warning will not be issued. The LCD display and corresponding printout will note the discrepancy with a “CHK” message in place of “FAIL” as shown below: Modck: 0 5 CHK Expect: 1 5
RJS, Minneapolis, MN
46
002-5568
Page 53
Operator’s Guide
Appendix G
Appendix G (ANSI Decodability) ANSI Decodability Calculations There is a specified method for calculating decodability for each symbol. But the method is generally the same for all. Each element width in a barcode symbol should be consistent across the symbol. Code 39 In the case of Code 39, two element widths are needed to produce a symbol. For optimum scanning, each narrow element, whether a bar or space, should have the same width dimension. And each wide element should have the same width dimension. Simply stated, the Decodability grade indicates the amount of tolerance remaining in the width of the most deviant element in the symbol. The more tolerance remaining, the higher the grade. The grade is displayed showing both a calculated numeric and a letter grade, i.g. “D/bility .90 A.”
UPC/EAN In the case of UPC and EAN symbols, the grade is calculated per a proposed guideline draft dated September 4, 1990 issued by the USS. Decodability Grade Conversions >= >= >= >= <
002-5568
.62 = A .50 = B .37 = C .25 = D .25 = F
47
RJS, Minneapolis, MN
Page 54
Appendix G
RJS, Minneapolis, MN
Operator’s Guide
48
002-5568