Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 5 of 9

Laser Inspector Model L1000 Operator's Guide, pages 37 to 45

Pages 37 to 45 of 81

The original document is the PDF (324 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the RJS Inspector L1000

Page 37

Operator’s Guide

Appendix A

Due to the flexibility and nature of Code 128, it is difficult to display “printable” and “nonprintable” control codes side by side without confusion. However, the approach taken here (detailed below) simplifies the displaying of this information.

As indicated before, each of the 3 subsets have “unique” features: Subset A allows for encodation of control codes but not lower case characters. Subset B allows for lower case characters but not control codes. Subset C allows for only numeric data in a compressed format.

Code 128 also offers the flexibility to “shift” to other subsets in order to combine the “unique” features into one condensed barcode. The encoded data occupies 2 rows on the LCD and is encoded in a columnar display with one character above the other. Display of Code 128 (Rules) • The first character (column) displays the subset (*A = Subset A). • The last character is a stop code (**). • The second from the last is a mod 103 check character. • Double characters beginning with alphanumeric characters designate nonprintable control codes applicable to all subsets. • Double numeric characters designate the compressed digit mode in subset C only. • Single characters will always be displayed on the lower row and are applicable to only subsets A and B (normal printable characters.)

002-5568

31

RJS, Minneapolis, MN

Page 38

Appendix A

Operator’s Guide

Example: Start Code Subset A

* A

Control Code Carrage return (Table A-1)

Char B (Table A-1)

A Char A (Table A-1)

B

3

Digit 3 (Table A-1)

C R

Digits 3 and 4 (Table A-3)

Shift to subset C (Table A-1)

L F

Cntl Code Line Feed (Table A-1)

C C

1 2

Digits 1 and 2 (Table A-3)

3 4

Stop Code (Table A-3)

? ?

* *

Calculated mod check

Refer to Code 128 tables (subsets) on the following pages:

RJS, Minneapolis, MN

32

002-5568

Page 39

Operator’s Guide

Appendix A

Note: Only the first and last alphanumerics of each ASCII Inspector. Shaded boxes are the Inspector’s display. Data Display character are displayed by the Laser

Table A-1 (Code 128, Subset A)

SP ! " # $ % & ' ( ) * + , - . / 0 1 2 3 4 5 6 7 8 9 : ; ! " # $ % & '() * + , - . / 0 1 23 4 5 6 7 8 9 : ;

<=> ? @ A B C D E F G H I J K L M N O P Q R S T U V W <=> ?@ A B C D E F G H I J K L M N O P Q R S T U V W

Y Z [ \ ] ^ _ NUL SOH STX ETX EOT ENQ ACK BEL BS HT LF

Y Z [¥] ^ _

N L

S H

S X

E X

E T

E Q

A K

B L

B S

H L T F

VT FF CR SO SI DLE DC1 DC2 DC3 DC4 NAK SYN ETB CAN EM SUB V T

F C F R

S O

S I

D E

D 1

D 2

D 3

D 4

N K

S N

E B

C N

E M

S B

ESC FS GS RS US FNC3 FNC2 SHIFT CODE-C CODE-B FNC-4 FNC-1 E C

F S

G R U S S S

F 3

F 2

S T

C C

C B

F 4

START (CODE A) START (CODE B) START (CODE C) STOP * A

002-5568

* B

* C

33

* *

RJS, Minneapolis, MN

F 1

Page 40

Appendix A

Operator’s Guide

Table A-2 (Code 128, Subset B) SP

! " # $ % & ' () * + , - . / 0 1 2 3 4 5 6 7 8 9 : ; ! " #

$ %

& ' () * + , - . /

0 1 2 3 4 5 6 7 8 9 : ;

<=> ? @ A B C D E F G H I J K L M N O P Q R S T U V W <=> ? @ A B C D E F G H I J K L M N O P Q R S T U V W

Y Z [ \ ] ^ _ ` a b c d e f g h I j k l m n o p q r s t Y Z [ ¥ ] ^_ ` a b c d e f g h i j k l m n o p q r s t u v w x y z { | } ~ DEL FNC-3 FNC-2 SHIFT CODE-C u v w x y z { | } ->

D L

F 3

F 2

S T

FNC-4

C C

F 4

START (CODE B)

START (CODE C)

STOP

* B

* C

* *

CODEA FNC1 C A

F 1

START (CODE A) * A

RJS, Minneapolis, MN

34

002-5568

Page 41

Operator’s Guide

Appendix A

Table A-3 (Code 128, Subset C) 00

01 02 03 04 05 06 07 08

09

10 11 12 13 14 15 16 17 18 19

0

0

0

0

0

0

0

0

0

0

1

1

1

1

1

1

1

1

1

0

1

2

3

4

5

6

7

8

9

0

1

2

3

4

5

6

7

8

29 30 31 32 33

34

35

36 37 38 39

1 9 20

21 22 23 24 25 26 27

28

2

2

2

2

2

2

2

2

2

2

3

3

3

3

3

3

3

3

3

0

1

2

3

4

5

6

7

8

9

0

1

2

3

4

5

6

7

8

3 9 40 41 42 4 0

4 1

43 44 45

4 2

4 3

4 4

46 47

4 5

4 6

48 49 50 51 52 53 54

55 56 57 58 59

4 8

5 5

4 7

4 9

5 0

5 1

5 2

5 3

5 4

5 6

5 7

5 8

5 9

60 61 62 63 64 65 66 67

68 69 70 71 72 73 74 75 76

77 78 79

6 0

6 8

7 7

6 1

6 2

6 3

6 4

6 5

6 6

6 7

6 9

7 0

7 1

7 2

7 3

7 4

7 5

89 90 91 92 93 94 95

7 6

7 8

7 9

80 81

82 83

84 85 86 87 88

96 97 98 99

8

8

8

8

8

8

8

8

8

8

9

9

9

9

9

9

9

9

9

0

1

2

3

4

5

6

7

8

9

0

1

2

3

4

5

6

7

8

9 9 CODE-B

CODE-C

C B

C A

START (CODE A) * A

002-5568

FNC-1 F 1 START (CODE B) * B

35

START (CODE C) * C

STOP * *

RJS, Minneapolis, MN

Page 42

Appendix A

Operator’s Guide

Note: On the LCD Display the Inspector will show a Yen symbol “¥”instead of a backslash “\” however it will print out as a backslash. On the LCD Display the Inspector will show a right arrow “®” instead of a tilde “~” however it will print out as a tilde.

USS Shipping Container Code (Case Code 128) When a Code 128 symbol is decoded and the first four characters are: Start C FNC1 0 0 The symbol is automatically analyzed as a USS Case Code symbol. For details consult the USS specification entitled Application Specification for the USS-128 Serial Shipping Container Code: (with symbol and shipping label guidelines).

RJS, Minneapolis, MN

36

002-5568

Page 43

Operator’s Guide

Appendix B

Appendix B (Code 93) Code 93 Code 93 encodes 43 data characters consisting of 0-9, A-Z, 6 symbols, 4 control characters and a unique start/stop character. The entire 128 ASCII character set is represented in code 93 using combinations of control characters and basic data characters. Each symbol includes 2 check characters. The symbols are checked by the Laser Inspector and displayed on the Mod Check Data Analysis screen. Check characters C and K

Start

*

C

9

3

A

Data characters

*

› Stop

The 2 check characters are referred to in the USS-Code 93 specifications as “C” and “K.” They are displayed in that order on the Data Analysis screen. The entire Code 93 character set is shown in Table B-1. The Laser Inspector displays the characters shown in the columns labeled Code 93 in the figure. Remember, some ASCII characters require 2 Code 93 symbol characters.

The Start/Stop and control characters cannot be displayed on the LCD as shown in Table B-1. They are displayed as:

002-5568

37

RJS, Minneapolis, MN

Page 44

Appendix B

Operator’s Guide

* is substituted for Stop/Start characters < is substituted for encircled $ > is substituted for encircled % ; is substituted for encircled / @ is substituted for encircled + The characters are also transmitted in this form in print and real time communications modes. See Table B-1 (Next Page)

RJS, Minneapolis, MN

38

002-5568

Page 45

Operator’s Guide

Appendix B

Table B-1 (Code 93 Character Set) ASCII

CODE 93

ASCII

CODE 93

ASCII

CODE 93

ASCII

CODE 93

NUL SOH STX ETX EOT ENQ ACK BEL BS HT LF VT FF CR SO SI DLE DC1 DC2 DC3 DC4 NAK SYN ETB CAN EM SUB ESC FS GS RS US

% U $ A $ B $ C $ D $ E $ F $ G $ H $ I $ J $ K $ L $ M $ N $ O $ P $ Q $ R $ S $ T $ U $ V $ W $ X $ Y $ Z %A % B % C % D % E

SP ! " # $ % & ' ( ) · + ,, • / 0 1 2 3 4 5 6 7 8 9 : ; < = > ?

Space / A / B / C $ % / F / G / H / I / J + / L, • / 0 1 2 3 4 5 6 7 8 9 / Z % F % G % H % I % J

@ A B C D E F G H I J K L M N O P Q R S T U V W X Y Z [ \ ] ^, % V A B C D E F G H I J K L M N O P Q R S T U V W X Y Z % K % L % M % N % O

’ a b c d e f g h i j k l m n o p q r s t u v w x y z { ; } ˜ DEL

% W + A + B + C + D + E + F + G + H + I + J + K + L + M + N + O + P + Q + R + S + T + U + V + W + X + Y + Z % P % Q % R % S % T

002-5568

39

RJS, Minneapolis, MN