Appendix H (Scanning Technique) The RJS Inspector bar code verifier that is supplied with this document incorporates a model CR1 scanner. The new CR1 provides three major improvements when compared to the previous model: 1. Codes with X dimensions as small as 5 mils (.005 inch, .127 mm) can be analyzed (vs. .0075 inch, .190 mm). 2. More accurate correlation to the ANSI Decodability calculation is achieved. 3. Bi-directional scanning movement provides better quiet zone analyses. The CR1 is compatible with all previous models of Laser Inspector L1000 and D4000 w/laser. Scanning Technique For most accurate analysis calculations, the laser beam should strike the bar code at an angle of approximately 30 degrees from vertical as shown in Figure 1. The scan distance is a function of the width of the bar code. Adjust the scan distance so it is a minimum of two inches (51 mm) or longer where the width of the laser beam is twice the width of the bar code and the bar code is centered in the beam as shown in Figure 2. A label containing this information is also attached to the top of the scanner for quick reference.

002-5568

49

RJS, Minneapolis, MN

Page 56

Appendix H

Operator’s Guide

Figure 1 – Scanning angle and distance

Scan distance – See Fig. 2 Scan Angle 30 degrees From Vertical

Figure 2 – Optimum beam width and placement Bar code centered in laser beam

*W *2W * Adjust scan distance at minimum 2” (51 mm) or the width of the laser beam is approximately two times the width of the bar code. Special Considerations When scanning codes on a low contrast substrate like brown corrugated material or a specular substrate such as shiny aluminum or plastic material, a scan angle other than 30 degrees from vertical may produce better decoding characteristics. Contact RJS Technical support if scanning problems occur.

RJS, Minneapolis, MN

50

002-5568

Page 57

Operator’s Guide

Appendix I

Appendix I (Quiet Zone Analysis) Quiet Zone Analysis The Laser Inspector trims data gathered during a scan to approximately 10 times the X dimension on each side of a bar code for all symbologies except UPC and EAN. The areas are assumed to be quiet zones and are included in the symbol analysis. If a low reflectance object is detected in these areas, the message “Warning QZ/SS” is displayed. This means a quiet zone is too narrow or the start (or stop) code may have extra elements encoded. Quiet Zone Analysis for UPC and EAN symbols are described in the following tables. In cases where an addendum is included in the bar code, an addendum gap analysis is also performed.

Table I-1 (Acceptable Parameters for Symbols Without Addendums) Symbology UPC-A UPC-E EAN-13 EAN-8

002-5568

Leading QZ 9X Minimum 9X Minimum 11X Minimum 7X Minimum

51

Trailing QZ 9X Minimum 7X Minimum 7X Minimum 7X Minimum

RJS, Minneapolis, MN

Page 58

Appendix I

Operator’s Guide

Table I-2 (Acceptable Parameters for Symbols With Addendums) Symbology UPC-A UPC-3 EAN-13 EAN-8

Leading QZ 9X Minimum 9X Minimum 11X Minimum 7X Minimum

RJS, Minneapolis, MN

52

Trailing QZ 5X Minimum 5X Minimum 5X Minimum 5X Minimum

GAP Size 9 - 12X 9 - 12X 7 - 10X 7 - 10X

002-5568

Page 59

Operator’s Guide

Appendix J

Appendix J Downloading the Database See also 5.4 Storage and Database Database Setup To setup a PC database use the standard comma delimited text file. Use any text editor or application to create a database file. Use commas and quotes as field delimiters as shown in the sample on the next page. A quote (“) cannot be part of the field datait is only a delimiter. Each message field can contain up to 16 characters. Database Record There are 3 fields in a database record: “01234567890512”, “GREEN BEANS”,“16oz $.99” Each field is in quotes (“ ”) separated by commas (,). Fields: 1. The first field is the key containing the data that is searched and matched to the scanned “data.” (01234567890512 in sample) 2. The second field contains the message entered in the database file; it displays on the first row of the LCD when the scanned barcode matches the database. 3. The third field contains a message in the database file; it displays on the second row of the LCD when the scanned barcode matches the database.

002-5568

53

RJS, Minneapolis, MN

Page 60

Appendix J

Operator’s Guide

(You can have many records (like the record above), stacked in a file. The start character for the file is an ASCII STX (hex 02), i.e. ALT-2. The end character for the file is an ASCII ETX (hex 03), i.e. ALT-3 )

Sample Database STX "01234567890512","UPC A+2","SAMPLE # 1", "9876543212344","EAN 13","SAMPLE # 2", "01234565","UPC E","SAMPLE # 3", "0192837243645","EAN 8+5","SAMPLE # 4", "123ABCDEF456","CODE 3of9","SAMPLE # 5", "987WXYZ","CODE 93","SAMPLE # 6", "01928374","CODE I 2 OF 5","SAMPLE # 7", "567RSTUVW","CODE 128","SAMPLE # 8", "124589","CODABAR SYMBOL","SAMPLE # 9", "00123456789012345675","CC 128 SYMBOL","SAMPLE # 10", ETX

Database Download Step 1) Plug the cable (002-2979) into the serial of an IBM compatible PC/AT/386/486 computer. Step 2)

Plug the connector of the cable into the Laser Inspector unit.

Step 3)

Turn on the Laser Inspector by pressing the ON switch or pressing the scanner trigger.

Step 4)

Using the MODE command of MS-DOS, enter communications the following:

MODE COMx:9600,n,8,1 Where x is the number of the communications

RJS, Minneapolis, MN

54

002-5568 port to be used.

port

Page 61

Operator’s Guide

Step 5)

Appendix J

Using the COPY command, download the sample data base:

COPY DBSAMPLE.TXT COMx: Again, where x is the number of the communications port. Once the start character is received, the existing database in the Inspector unit is erased and the new database is placed in the database buffer. After the end character is received, 4 messages are displayed in succession on the LCD: 1. Database Parsing 2. Database Sorting 3. Database Loading 4. Completed A few seconds after the “Database Loading Completed” message has displayed, the Main Menu will display. Or you may encounter one of the following error messages:

Memory Overflow (If the database exceeds the buffer limit)

Format Error (If the data format is incorrect)

002-5568

55

RJS, Minneapolis, MN

Page 62

Appendix J

Operator’s Guide

Data Base Record Does Not Exist (If the scanned symbol does not match the record in the database)

Communication Parameters Serial communication, RS-232 signal levels Baud rate: 9600 Data Length: 8 bit Parity: None Stop bits: 1 Hardware/Software protocols: RJS PC database download serial interface cable (0022979) Database buffer size: 0 - 20K allocated via the Setup Menu Key Field Descriptions Symbology characteristics to consider when creating key fields in your database: UPC Version “A” The UPC-A database key must be made up of all 12 digits in the barcode (including the Mod check digit). When a 2 or 5 digit addendum is scanned, these additional digits must be appended to the end of the database key. UPC Version “E” The UPC-E database key must be made up of all 8 digits in the barcode (including the Mod check digit). When a 2 or 5 digit addendum is scanned, these additional digits must be appended to the end of the database key.

RJS, Minneapolis, MN

56

002-5568

Page 63

Operator’s Guide

Appendix J

EAN-13 The EAN-13 database key must be made up of all 13 digits in the barcode (including the Mod check digit). When a 2 or 5 digit addendum is scanned, these additional digits must be appended to the end of the database key. EAN-8 The EAN-8 database key must be made up of all 8 digits in the barcode (including the Mod check digit). When a 2 or 5 digit addendum is scanned, these additional digits must be appended to the end of the database key. Code 3 of 9 The Code 3 of 9 database key must be made up of all data characters in the barcode (including the Mod check digits or prefix indicators, such as those used within the HIBC specification). The standard Start/Stop characters used in Code 3 of 9 symbology are not to be included. Interleaved 2 of 5 The Interleaved 2 of 5 (I2of5) database key must be made up of all the digits in the barcode (including the Mod check digit found in the I2of5 Case Code specification, if applicable). Codabar The Codabar database key must be made up of all the digits in the barcode (excluding the Start/Stop codes).

002-5568

57

RJS, Minneapolis, MN