The text of a manual · part 4 of 8
Qlarity-Based Terminal Hardware User's Manual: QTERM-G75 Terminal
Pages 19 to 26 of 56, from Qlarity-Based Terminal Hardware User's Manual
The original document is the PDF (895 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the QSI Corp QTERM-G70
Page 19
CHAPTER 2 QTERM-G75 TERMINAL
2.1 Product Description The QTERM-G75™ terminal is a large display Ethernetenabled graphic terminal with object-based programming. It features a robust list of industrial grade hardware features and options. The QTERM-G75 features a VGA, 640x480 pixel, activematrix TFT LCD display (256 colors). It uses a dual lamp cold-cathode fluorescent backlight (CCFL). The CCFL provides high contrast and easy readability and is replaceable. The analog-resistive touch screen covers the full viewable area of the display as well as the pre-labeled legend underlay on each side of the display. The QTERM-G75 comes equipped with one serial port using an EIA-232, EIA-422, or EIA-485 interface. A second serial port, an Ethernet port, and a PS/2 keyboard port are available as options. Possible input devices include the touch screen and attachable keyboard (with an optional PS/2 connector). Custom configurations of the QTERM-G75 can also support an external keypad, a dual EIA-232 full serial port card or a quad EIA-232 full serial port card (contact QSI Corporation for details). A speaker, which has programmable pitch and duration, comes standard, as does a battery-backed realtime clock. Other options include: an audio decoder for playing audio wave files, a hardware watchdog timer and a 5 V/100 mA output from the auxiliary serial port to power external devices. The QTERM-G75 terminal stores the firmware and the user application in a compressed format in flash memory and then transfers them to RAM memory when the terminal is powered on. The terminal is equipped with eight megabytes of flash memory and 32 megabytes of RAM memory. The Power-over-Ethernet units is equipped with four megabytes of flash memory and sixteen megabytes of RAM.
The QTERM-G75 terminal requires a DC power source in a range of 8 to 26 V dc. This power is supplied via the main DB9 serial connector. Other options for supplying power to the QTERM-G75 are PoE (Power-over-Ethernet) or five volts from a well-regulated power supply via the main DB9 serial connector. Please contact QSI for more information about this option. 2.1.1 Specifications The following tables contain the technical specifications for the QTERM-G75 TERMINAL DISPLAY Active Matrix (standard)
TFT 256 colors
Enhanced TFT (optional) Enhanced TFT 256 colors Pixels
640x480
Dot Pitch
0.33 mm
Lighting
Dual lamp cold-cathode fluorescent, brightness is softwarecontrollable
Backlight Brightness
TFT 550 nits typical Enhanced TFT 800 nits typical
TOUCH SCREEN Analog-resistive operation Transparent touch area over viewable display Labeled touch underlay area on each side of display INTERFACE Standard
EIA-232 serial port with hardware or software handshaking
Baud rates
600 – 115,200 bps
None Flow control XonXoff (software) RTS/CTS (hardware)
The outer legend can be customized with your logo/name or graphics. The inner legend underlay around the display can be customized with your touch keys and graphics.
QSI Corporation Fax 801-466-8792 Web www.qsicorp.com Phone 801-466-8770
Page 20
12
QSI Qlarity-based Terminal Hardware
ENVIRONMENTAL
INTERFACE 7 or 8 data bits 1 or 2 stop bits Data formats Even, odd, or no parity (PC Tools support only 8 data bits) Connector
DB9f (2 with optional second serial port) 8-pin modular (RJ45) with Ethernet option PS/2 keyboard connector (optional)
Options
Primary serial port configurable as EIA-232, EIA-422, or EIA-485 Secondary serial port available (EIA-232, EIA-422, or EIA-485) Ethernet 10/100Base-T with support for TCP/IP networking PS/2 keyboard port Additional dual or quad full EIA-232 serial port cards available
Humidity
0 to 95%, non-condensing
Vibration
5 to 5000 Hz, 4 g RMS
Shock
20 g, 3 ms, any axis POWER
8 to 26 VDC (See section 2.4.3 for current consumption) PoE (Power-over-Ethernet) SOFTWARE Programming language
Qlarity™ (object-based)
Design environment
Qlarity Foundry™ (Windows®)
Command line compiler Qlarify (Win32® or Linux) CUSTOMIZING Outer legend Customize with logo/name or graphics Inner legend Customize with touch keys and graphics
MEMORY Standard
8 Mbytes flash and 32 Mbytes SDRAM
PoE
4 Mbytes flash and 16 Mbytes SDRAM SPEAKER
Standard
Software programmable pitch and duration
Optional
Audio (.wav) decoder REAL-TIME CLOCK
Independent processor-based, real-time clock equipped with a battery backup PHYSICAL Configuration Panel-mount Housing
Aluminum, accommodates panels from 0 to 12 mm thick with standard screws
Size
330 x 260 x 55.3 mm
Weight
2.9 kg
Processor
400 MHz Intel® XScale™ core (standard) 200 MHz Intel® XScale™ core (PoE) ENVIRONMENTAL
Sealing
NEMA-4 front panel
Temperature
Operating: -10 to 60 ° C Storage: -20 to 70 °C
CERTIFICATION FCC Part 15, Class A CE Certification
2.2 Supported Interfaces 2.2.1 Serial Ports The QTERM-G75 comes standard with one serial port with DB9f connector. The serial port interface can be EIA-232, EIA-422, or EIA-485. A second serial port is available as an option, as well as two or four additional full EIA-232 serial ports are also optional. NOTE: The primary and auxiliary serial ports are wired as Data Communications Equipment (DCE).
EIA-232 with proper cables and grounding the terminal can communicate up to five meters at a top speed of 115,200 bps
EIA-422 permits operation at distances up to 2,000 meters
EIA-485 permits multiple terminals to be connected in a multi-drop chain
QSI Corporation Fax 801-466-8792 Web www.qsicorp.com Phone 801-466-8770
Page 21
QSI Qlarity-based Terminal Hardware
13
The figure below shows the serial connector’s orientation. 1
5
1
9
6
1 2 3 4 5 6 7 8
RJ45 Connector (Back of unit)
Female DB9 Connector (Back of unit)
Tx+ TxRx+, - Rx - - 2.2.3 Optional PS/2 Keyboard Interface
The following table shows the pinouts for each type of serial interface. Pin
232
422
485
1, Tx-
RTx-
2
Tx
Tx+
RTx+
3
Rx
Rx+, 4, - - 5
Ground
Ground
Ground
6, Rx-, 7
CTS (in), 8
RTS (out), 9
Power
Power
Pinout Table
8
Power
Power is supplied to the terminal through pin 9 and ground is supplied through pin 5 of the primary serial port connector. 2.2.2 Optional Ethernet Port The optional Ethernet port has a standard 10/100Base-T interface with an 8-pin (RJ-45) modular jack connector and uses TCP/IP protocol. The connector orientation and pinout table are shown in the following table.
The optional PS/2 port can be used to connect a standard PS/2 keyboard to the QTERM-G75 terminal. The connector orientation and pinout table are shown in the table that follows.
1 3 5
2 4 6
Female Mini-DIN Connector (Back of unit)
1 2 3 4 5 6
Pinout Table +Keyboard Data, Ground +5 Volts Clock, 2.2.4 Optional 5 Volt Power Supply on Secondary Serial Port The secondary serial port interface (if included) can optionally be configured to provide a 5 volt DC power supply. The supply can provide up to 100 mA current to a serial peripheral device (such as a barcode reader) connected to COM2. The 5 volt supply is provided on pin 9 and returns to ground on pin 5. 2.2.5 Optional Dual and Quad EIA-232 Serial Port Card An additional two or four EIA-232 serial ports can be added to the QTERM-G75. These serial ports have all necessary signals for EIA-232 serial communications and are wired as Data Terminal Equipment (DTE). The additional serial port option will add approximately 10 mA to the total current draw of the terminal plus 15 mA per connected serial cable.
QSI Corporation Fax 801-466-8792 Web www.qsicorp.com Phone 801-466-8770
Page 22
14
QSI Qlarity-based Terminal Hardware
The following table shows the pinouts for the additional serial port option. Additional EIA-232 Serial Port Pinouts 1
DCD (in)
2
Rx (in)
3
Tx (out)
4
DTR (out)
5
GND
6
DSR (in)
7
RTS (out)
8
CTS (in)
9
RI (in)
Touch keys can also be defined in your user applications at any location on or around the display. Touch keys may be any size. 2.3.2 Keyboard Using the optional PS/2 port, a standard PC keyboard may be used in addition to, or in place of, the touch screen. Power On Setup, the terminal setup utility, recognizes both touch keys and keyboard keys. 2.3.3 Keypad The QTERM-G75 terminal can optionally include electronics for attaching an external keypad with up to 8 columns by 8 rows and up to 6 keypad LEDs. Contact QSI Corporation for more information.
2.2.6 Optional Power-over-Ethernet Module The optional Power-over-Ethernet module allows the user to provide power and communications to the QTERM-G75. The power can be provided from an IEEE 802.3af compliant hub or switch as well as from a standard power supply.
The keypad option will add 10 mA to the total current draw of the terminal plus the current driven out the LED outputs pins. The LED outputs are five-volt open-collector signals with a 1000 Ohm series resistor. This results in an approximate maximum output current drive of 5 mA on those pins. There are two connectors on the keypad module to facilitate connecting different sized keypads. The pinouts for those connectors are shown in the following table:
2.3 Terminal Components Connector J1 - 0.1 Inch Pitch 16-pin Single-row Connector
2.3.1 Touch Screen The QTERM-G75 touch screen provides user input through any number of touch keys located on or around the display. The standard key legend shown in the figure below provides areas for five soft keys down each side of the display. A custom legend underlay can be ordered to personalize the terminal for your application. 330.0
1
GND
9
Row 5
2
LED 1
10
Row 6
3
Row 1
11
Col 1
4
Row 2
12
Col 2
5
Row 3
13
Col 3
6
Row 4
14
Col 4
7
GND
15
Col 5
8
LED 2
16
Col 6
255.0 213.0
QTERM-G75 10.4 Panel Mount
183.4 160.2
260.0
QSI CORPORATION
Display Area Touchscreen Area (Graphics may be customized)
Front View
QSI Corporation Fax 801-466-8792 Web www.qsicorp.com Phone 801-466-8770
Page 23
QSI Qlarity-based Terminal Hardware
15 time/date stamp messages or for timed polling and program execution.
Connector J2 - 0.1 Inch Pitch 24-pin Dual-row Connector 1
Row 1
13
Col 1
2
5 V or 3.3 V
14
LED 4
3
Row 2
15
Col 2
4
GND
16
LED 3
5
Row 3
17
Col 3
6
LED 6
18
LED 2
7
Row 4
19
Col 4
8
LED 5
20
LED 1
9
Row 5
21
Col 5
10
Row 8
22
Col 6
11
Row 6
23
Col 8
12
Row 7
24
Col 7
WARNING There may be danger of leakage if the battery is incorrectly replaced, creating a potential health hazard. Replace the battery only with the same (Duracell CR1220) or equivalent type recommended by the manufacturer. Dispose of used batteries according to the manufacturer’s instructions. 2.3.6 System Memory The QTERM-G75 terminal stores the firmware and user applications in a compressed format in flash memory and then transfers them to RAM memory when the terminal is powered on. Eight megabytes of flash memory and 32 megabytes of RAM memory are included on the standard unit. The PoE unit has four megabytes of flash memory and sixteen megabytes of RAM memory.
2.3.4 Speaker A speaker is built into the QTERM-G75 terminals and faces to the back of the unit. Audio can be linked to events or actions (e.g., screen press, timer, etc.). Pitch and duration of a sound are controlled by API functions called from the user application. Refer to “Controlling the Speaker” section in the Qlarity-based Terminal Programmer's Reference Manual.
For information on using resources efficiently to conserve memory when creating a user application, refer to “Edit Resources” section in the Qlarity Foundry User’s Manual. For information on downloading new firmware, downloading a user application, and determining the size of a user application, refer to the Qlarity Foundry User’s Manual. 2.3.7 Watchdog Timer
Optionally, an audio (.wav) decoder can be added to the QTERM-G75 to allow the speaker to play audio files. The audio decoder supports wave files meeting the following criteria:
• Sample rate of 8 kHz, 11.025 kHz, 16 kHz or 22.050 kHz • Resolution of 8 or 16 bits per sample. The audio decoder circuit amplifies the signal to 0.5 W rms at the speaker.
A watchdog timer can be optionally added to enforce proper operation of the QTERM-G75. The watchdog timer will reset the terminal if there is a problem causing the firmware to lock up. This does not apply to software deadlocks in the Qlarity code. If that is required, then the Qlarity watchdog timer should be used, using the WatchdogEnable and WatchdogReset APIs.
2.4 Installing the QTERM-G75 Terminal to NEMA-4 Specifications
2.3.5 Real-Time Clock The QTERM-G75 terminal is equipped with a batterybacked, real-time clock. The real-time clock can be used to
A QTERM-G75 terminal uses a rugged aluminum case designed to mount into a panel. When properly installed in a NEMA-4 rated panel, the QTERM-G75 meets all NEMA-4 specifications including hose-down, icing, and salt spray. A QTERM-G75 terminal can be installed in either a landscape or portrait orientation. When installing a terminal, you generally take the following steps.
QSI Corporation Fax 801-466-8792 Web www.qsicorp.com Phone 801-466-8770
Page 24
16
QSI Qlarity-based Terminal Hardware
• Decide whether you want to mount and use the terminal
Following is a diagram of the landscape cutout:
in a portrait or landscape orientation. “Portrait” means that the longest dimension is vertical; “landscape” means that the longest dimension is horizontal.
308.0 291.0±1.0 154.0
4.6 diameter through 14 places
• Cut a hole in the panel and drill the mounting holes. See section 2.4.1, “Cutting Out the Panel” for specifications.
R3.2 Max. (four inside corners)
• Install the QTERM-G75 terminal in the panel. See section 2.4.2, “Installing the Terminal” for instructions. 221.0±1.0
• Connect cables to the terminal. Verify that the thumb
80.0
238.0 screws are tight or the locks snapped into place for each cable used.
• Apply DC power to the QTERM-G75 terminal See section 2.4.3, “Applying Power” for information. 2.4.1 Cutting Out the Panel The QTERM-G75 terminal can be mounted in panels from 0 to 12 mm thick. Fourteen screw holes need to be drilled to install the terminal in the panel. The mounting holes should be 4.6 mm in diameter and drilled as shown in the figure below.
Panel Cutout Dimensions
File any rough edges smooth, especially on the face of the panel. 2.4.2 Installing the Terminal
Make a rectangular hole in the panel using the following dimensions.
Take the following steps to install the terminal. Refer to the illustrations on the next page.
Landscape: Horizontal Vertical
1. 291 ± 1 mm 221 ± 1 mm
Portrait: Horizontal Vertical
Verify that the panel surface around the cutout and mounting holes is clean and free of rough edges. A gasket built into the terminal will seal against this surface. Dirt or imperfections on the panel may prevent a proper seal.
221 ± 1 mm 291 ± 1 mm
2.
Place the terminal into the panel cutout (inserting the studs into the mounting holes) and verify that the terminal is oriented correctly. The touch screen legend may indicate the orientation. If not, you can determine which side should be at the top by the position of the serial port on the back panel as follows: Landscape: when looking at the front of the unit, the back panel serial port(s) should be near the top of the terminal.
QSI Corporation Fax 801-466-8792 Web www.qsicorp.com Phone 801-466-8770
Page 25
QSI Qlarity-based Terminal Hardware
Portrait: when looking at the front of the unit, the back panel serial port(s) should be on the right side of the terminal.
QTERM-G75 10.4 Panel Mount
183.4 160.2 260.0
Power is supplied to the QTERM-G75 terminal via the primary serial port connector. Refer to section 2.2.1, “Serial Ports” for the pin assignments for power and ground. DC power must be in the range of 8 to 26 volts (the current will vary depending on the input voltage; see table below). QTERM-G75 power must come from an SELV (Safety Extra Low Voltage) power CAUTION source and should have a current limit on its output of 5 Amperes. It must provide a minimum of 8 volts DC power and be limited to a maximum of 26 volts DC. Limiting may be inherent to the supply or may be provided by supplementary overcurrent devices. If the QTERM-G75 does not respond or exhibits abnormal behavior on power up, disconnect power and contact QSI for technical support.
QSI CORPORATION
Front View
COM1
Tighten all nuts to create the seal between the terminal gasket and the panel. Avoid overtightening the nuts. 2.4.3 Applying Power
330.0 255.0 213.0
Display Area Touchscreen Area (Graphics may be customized)
17
Optional COM2
Speaker
M4 x 10 mm long Grounding Stud
Current Consumption Terminal
12 VDC
24 VDC
Standard unit idle
950 mA
475 mA
Back View
Enhanced unit idle
1.0 A
500 mA
55.3
Standard unit, active add 100 mA add 60 mA
Enhanced unit, active add 100 mA add 60 mA
With keyboard option and keyboard attached add 70 mA add 35 mA
With Ethernet option and connection add 40 mA add 20 mA
Optional Ethernet Output
Optional Keyboard Output
Front Panel
8.4 mm long M4 Ground Stud (ref.) M4 Nuts w/Lockwashers Front Panel Stiffener Mounting Panel
Right Side View
3.
4.
On the back of the panel, align the terminal mounting bracket holes with the mounting studs and place the bracket against the back of the panel. Attachments with lockwashers (supplied with the terminal) onto each of the fourteen mounting studs.
2.4.4 Powering On the Terminal for the First Time When you connect power to the QTERM-G75 terminal, it automatically loads the application saved in flash memory into RAM memory and displays the application. If no application is present, the terminal display is blank but the backlighting verifies that it is powered on. When you power on the terminal for the first time, a demo program (or a special application custom designed for your company) loads. The demo program will help you verify that the terminal is operating properly. Follow the on-screen prompts or any documentation accompanying the program
QSI Corporation Fax 801-466-8792 Web www.qsicorp.com Phone 801-466-8770
Page 26
18
QSI Qlarity-based Terminal Hardware to guide you through tests or demonstrations designed to verify terminal operation. Once you have verified that the terminal is functioning properly, refer to Chapter 5, “Power On Setup” for information on configuring your terminal. The Power On Setup utility includes functions to do the following:
• Change orientation of the terminal (portrait or landscape)
• Download a new user application to the terminal • Select the application mode • Set up communications settings for the terminal • Adjust display contrast or backlight • Enter network (Ethernet) settings • Enter/change password (if used) • Set the real time clock
QSI Corporation Fax 801-466-8792 Web www.qsicorp.com Phone 801-466-8770