Page 9

CHAPTER 1 QTERM-G70 TERMINAL

1.1 Product Description The QTERM-G70™ terminal is an Ethernet-enabled graphic terminal with object-based programming. It features a robust list of industrial grade hardware features and options. The QTERM-G70 features a QVGA, 320x240 pixel, LCD display available in STN color (256 colors) or optional grayscale (16 shades) or active-matrix TFT (256 colors). It uses a cold-cathode fluorescent backlight (CCFL). The CCFL provides high contrast and easy readability and is replaceable. On STN and grayscale units, the contrast is software-controlled and compensated for temperature. The analog-resistive touch screen covers the full viewable area of the display as well as the pre-labeled legend underlay on each side of the display.

The outer legend can be customized with your logo/name or graphics. The inner legend underlay around the display can be customized with your touch keys and graphics. The QTERM-G70 terminal requires a DC power source in a range of 8 to 26 V dc. This power is supplied via the main DB9 serial connector. Other options for supplying power to the QTERM-G70 are PoE (Power-over-Ethernet) and five volts from a well-regulated power supply via the main DB9 serial connector. Please contact QSI for more information about this option. The five volt power supply input option is only available on terminals with the TFT display option. 1.1.1 Specifications The following tables contain the technical specifications for the QTERM-G70. TERMINAL DISPLAY

The QTERM-G70 comes equipped with one serial port using an EIA-232, EIA-422, or EIA-485 interface. A second serial port, an Ethernet port, and a PS/2 keyboard port are available as options. Possible input devices include the touch screen and attachable keyboard (with an optional PS/2 connector). Custom configurations of the QTERM-G70 can also support an external keypad, a dual EIA-232 full serial port card or a quad EIA-232 full serial port card (contact QSI Corporation for details). A speaker, which has programmable pitch and duration, comes standard, as does a battery-backed realtime clock. Other options include: an audio decoder for playing audio wave files, a hardware watchdog timer and a 5 V/100 mA output from the auxiliary serial port to power external devices. The QTERM-G70 terminal stores the firmware and the user application in a compressed format in flash memory and then transfers them to RAM memory when the terminal is powered on. The terminal is equipped with four megabytes of flash memory and sixteen megabytes of RAM memory.

Color (standard)

STN 256 colors

Grayscale (optional)

FSTN 16 shades of gray

Active Matrix (optional)

TFT 256 colors

Enhanced TFT (optional) Enhanced TFT 256 colors Pixels

320 x 240

Dot Pitch

0.36 mm

Contrast

Software-controlled, temperature compensated (N/A on TFT units)

Lighting

Cold-cathode fluorescent, brightness is softwarecontrollable

Backlight Brightness

Color 200 nits typical Grayscale 195 nits typical TFT 470 nits typical Enhanced TFT 600 nits typical

TOUCH SCREEN Analog-resistive operation

QSI Corporation Fax 801-466-8792 Web www.qsicorp.com Phone 801-466-8770

Page 10

2

QSI Qlarity-based Terminal Hardware

PHYSICAL

TOUCH SCREEN Transparent touch area over viewable display

Weight

1.16 kg

Labeled touch underlay area on each side of display

Processor

200 MHz Intel® XScale™ core platform ENVIRONMENTAL

INTERFACE Standard

EIA-232 serial port with hardware or software handshaking

Baud rates

600 – 115,200 bps

None Flow control XonXoff (software) RTS/CTS (hardware) 7 or 8 data bits 1 or 2 stop bits Data formats Even, odd, or no parity (PC Tools support only 8 data bits) Connector

Options

DB9f (2 with optional second serial port) 8-pin modular (RJ45) with Ethernet option PS/2 keyboard connector (optional) Primary serial port configurable as EIA-232, EIA-422, or EIA-485 Secondary serial port available (EIA-232, EIA-422, or EIA-485) Ethernet 10/100Base-T with support for TCP/IP networking PS/2 keyboard port Additional dual or quad full EIA-232 serial port cards available MEMORY

Standard

Sealing

NEMA-4 front panel

Temperature

Operating: -10 to 60 ° C Storage: -20 to 70 °C

Humidity

0 to 95%, non-condensing

Vibration

5 to 5000 Hz, 4 g RMS

Shock

20 g, 3 ms, any axis POWER

8 to 26 VDC (See section 1.4.5 for current consumption) PoE (Power-over-Ethernet) Well-regulated 5V supply (contact QSI Corporation) SOFTWARE Programming language

Qlarity™ (object-based)

Design environment

Qlarity Foundry™ (Windows®)

Command line compiler Qlarify (Win32® or Linux) CUSTOMIZING Outer legend Customize with logo/name or graphics Inner legend Customize with touch keys and graphics CERTIFICATION FCC Part 15, Class A CE Certification

4 Mbytes flash and 16 Mbytes SDRAM SPEAKER

Standard

Software programmable pitch and duration

Optional

Audio (.wav) decoder REAL-TIME CLOCK

Independent processor-based, real-time clock equipped with a battery backup PHYSICAL Configuration Panel-mount Housing

Glass-filled polyester, UL 94V-0 flame rating, accommodates panels from 0 to 7 mm thick with standard screws

Size

215 x 161 x 50 mm

1.2 Supported Interfaces 1.2.1 Serial Ports The QTERM-G70 comes standard with one serial port with DB9f connector. The serial port interface can be EIA-232, EIA-422, or EIA-485. A second serial port is available as an option, as well as two or four additional full EIA-232 serial ports are also optional. NOTE: The primary and auxiliary serial ports are wired as Data Communications Equipment (DCE).

QSI Corporation Fax 801-466-8792 Web www.qsicorp.com Phone 801-466-8770

Page 11

QSI Qlarity-based Terminal Hardware

EIA-232 with proper cables and grounding the terminal can communicate up to five meters at a top speed of 115,200 bps

EIA-422 permits operation at distances up to 2,000 meters

EIA-485 permits multiple terminals to be connected in a multi-drop chain

The figure below shows the serial connector’s orientation.

5

1

9

6

1

Pinout Table

8

1 2 3 4 5 6 7 8

RJ45 Connector (Back of unit)

Tx+ TxRx+, - Rx - - 1.2.3 Optional PS/2 Keyboard Interface The optional PS/2 port can be used to connect a standard PS/2 keyboard to the QTERM-G70 terminal. The connector orientation and pinout table are shown below.

Female DB9 Connector (Back of unit)

1 3 5

The following table shows the pinouts for each type of serial interface. Pin

232

422

485

1, Tx-

RTx-

2

Tx

Tx+

RTx+

3

Rx

Rx+, 4, - - 5

Ground

Ground

Ground

6, Rx-, 7

CTS (in), 8

RTS (out), 9

Power

Power

3

2 4 6

Female Mini-DIN Connector (Back of unit)

1 2 3 4 5 6

Pinout Table +Keyboard Data, Ground +5 Volts Clock, NOTE: PS/2 keyboard interface is not available in the terminals with the PoE option. 1.2.4 Optional 5 Volt Power Supply on Secondary Serial Port The secondary serial port interface (if included) can optionally be configured to provide a 5 volt DC power supply. The supply can provide up to 100 mA current to a serial peripheral device (such as a barcode reader) connected to COM2. The 5 volt supply is provided on pin 9 and returns to ground on pin 5.

Power

Power is supplied to the terminal through pin 9 and ground is supplied through pin 5 of the primary serial port connector. 1.2.2 Optional Ethernet Port The optional Ethernet port has a standard 10/100Base-T interface with an 8-pin (RJ-45) modular jack connector and uses TCP/IP protocol.

1.2.5 Optional Dual and Quad EIA-232 Serial Port Card An additional two or four EIA-232 serial ports can be added to the QTERM-G70. These serial ports have all necessary signals for EIA-232 serial communications and are wired as Data Terminal Equipment (DTE). The additional serial port option will add approximately 10 mA to the total current draw of the terminal plus 15 mA per connected serial cable.

The connector orientation and pinout table are shown in the following table.

QSI Corporation Fax 801-466-8792 Web www.qsicorp.com Phone 801-466-8770

Page 12

4

QSI Qlarity-based Terminal Hardware

The following table shows the pinouts for the additional serial port option.

in the following table. The table also shows the conductor assignment for the transmit and receive lines as reference.

Additional EIA-232 Serial Port Pinouts

Port Pin Assignment Conductor

Mode A

Mode B

1

Tx+/V+

Tx+

2

Tx-/V+

Tx-

3

Rx+/V-

Rx+

1

DCD (in)

2

Rx (in)

3

Tx (out)

4

DTR (out)

4

V+

5

GND

5

V+

6

DSR (in)

7

RTS (out)

8

CTS (in)

9

RI (in)

1.2.6 Optional Power-over-Ethernet Module The optional Power-over-Ethernet module allows the user to provide power and communications to the QTERM-G70. The power can be provided from an IEEE 802.3af compliant hub or switch as well as from a standard power supply. 1.2.6.1 Power Requirements The optimal power supplied to the QTERM-G70 through the PoE port is 48 V dc, although the unit will operate with a power input as low as 36 V dc, or as high as 57 V dc (see IEEE 802.3af specification). The power required to operate the terminal without any additional options is listed below.

6

Rx-/V-

Rx-

7

V-

8

V-

1.3 Terminal Components 1.3.1 Touch Screen The QTERM-G70 touch screen provides user input through any number of touch keys located on or around the display. The standard key legend shown in the figure below provides areas for five soft keys down each side of the display. A custom legend underlay can be ordered to personalize the terminal for your application.

Current Consumption Terminal

48VDC

G70 STN Idle

120 mA

G70 TFT Idle

190 mA

Active Add

+15 mA

1.2.6.2 Pinouts In accordance with the PoE standard (IEEE 802.3af), the PoE port is insensitive to polarity of the power supply and can receive power in either mode A (superimposed on the transmit and receive twisted pair conductors) or mode B (using the additional twisted pair conductors). This yields four possible ways to apply power to the PoE port as shown

Touch keys can also be defined in your user applications at any location on or around the display. Touch keys may be any size. 1.3.2 Keyboard Using the optional PS/2 port, a standard PC keyboard may be used in addition to, or in place of, the touch screen.

QSI Corporation Fax 801-466-8792 Web www.qsicorp.com Phone 801-466-8770

Page 13

QSI Qlarity-based Terminal Hardware

5

Power On Setup, the terminal setup utility, recognizes both touch keys and keyboard keys. 1.3.3 Keypad The QTERM-G70 terminal can optionally include electronics for attaching an external keypad with up to 8 columns by 8 rows and up to 6 keypad LEDs. Contact QSI Corporation for more information. The keypad option will add 10 mA to the total current draw of the terminal plus the current driven out the LED outputs pins. The LED outputs are five-volt open-collector signals with a 1000 Ohm series resistor. This results in an approximate maximum output current drive of 5 mA on those pins. There are two connectors on the keypad module to facilitate connecting different sized keypads. The pinouts for those connectors are as follows: Connector J1 - 0.1 Inch Pitch 16-pin Single-row Connector

Connector J2 - 0.1 Inch Pitch 24-pin Dual-row Connector 11

Row 6

23

Col 8

12

Row 7

24

Col 7

1.3.4 Speaker A speaker is built into the QTERM-G70 terminal and faces to the back of the unit. Audio can be linked to events or actions (e.g., screen press, timer, etc.). Pitch and duration of a sound are controlled by API functions called from the user application. Refer to “Controlling the Speaker” section in the Qlarity-based Terminal Programmer's Reference Manual. Optionally, an audio (.wav) decoder can be added to the QTERM-G70 to allow the speaker to play audio files. The audio decoder supports wave files meeting the following criteria:

• Sample rate of 8 kHz, 11.025 kHz, 16 kHz or 22.050 kHz • Resolution of 8 or 16 bits per sample.

1

GND

9

Row 5

2

LED 1

10

Row 6

3

Row 1

11

Col 1

4

Row 2

12

Col 2

The audio decoder circuit amplifies the signal to 0.5 W rms at the speaker.

5

Row 3

13

Col 3

1.3.5 Real-Time Clock

6

Row 4

14

Col 4

7

GND

15

Col 5

8

LED 2

16

Col 6

Connector J2 - 0.1 Inch Pitch 24-pin Dual-row Connector 1

Row 1

13

Col 1

2

5 V or 3.3 V

14

LED 4

3

Row 2

15

Col 2

4

GND

16

LED 3

5

Row 3

17

Col 3

6

LED 6

18

LED 2

7

Row 4

19

Col 4

8

LED 5

20

LED 1

9

Row 5

21

Col 5

10

Row 8

22

Col 6

The QTERM-G70 terminal is equipped with a batterybacked, real-time clock. The real-time clock can be used to time/date stamp messages or for timed polling and program execution. WARNING There may be danger of leakage if the battery is incorrectly replaced, creating a potential health hazard. Replace the battery only with the same (Duracell CR1220) or equivalent type recommended by the manufacturer. Dispose of used batteries according to the manufacturer’s instructions. 1.3.6 System Memory The QTERM-G70 terminal stores the firmware and user applications in a compressed format in flash memory and then transfers them to RAM memory when the terminal is powered on. Four megabytes of flash memory and sixteen megabytes of RAM memory are standard.

QSI Corporation Fax 801-466-8792 Web www.qsicorp.com Phone 801-466-8770

Page 14

6

QSI Qlarity-based Terminal Hardware

For information on using resources efficiently to conserve memory when creating a user application, refer to “Edit Resources” section in the Qlarity Foundry User’s Manual. For information on downloading new firmware, downloading a user application, and determining the size of a user application, refer to the Qlarity Foundry User’s Manual.

1.4.1 Cutout for Panel Mount Configuration The QTERM-G70 terminal can be mounted in panels from 0 to 7 mm thick. No screw holes need to be drilled to install the terminal in the panel. Make a rectangular hole in the panel using the following dimensions.

1.3.7 Watchdog Timer A watchdog timer can be optionally added to enforce proper operation of the QTERM-G70. The watchdog timer will reset the terminal if there is a problem that causes the firmware to lock up. This does not apply to software deadlocks in the Qlarity code. If that is required, then the Qlarity watchdog timer should be used, using the WatchdogEnable and WatchdogReset APIs.

Landscape: Horizontal Vertical

199 ± 1 mm 145 ± 1 mm

Portrait: Horizontal Vertical

145 ± 1 mm 199 ± 1 mm

Following is a diagram of the landscape cutout:

1.4 Installing the QTERM-G70 Terminal to NEMA-4 Specifications

199 + –1

A QTERM-G70 terminal uses a rugged, glass-filled polyester (UL 94V-0) case designed to mount into a panel or drywall. When properly installed in a NEMA-4 rated panel, the QTERM-G70 meets all NEMA-4 specifications including hose-down, icing, and salt spray.

Cutout

3.2 radius max.

145 + –1

A QTERM-G70 terminal can be installed in either a landscape or portrait orientation. When installing a terminal, you generally take the following steps.

• Decide whether you want to mount and use the terminal in a portrait or landscape orientation. “Portrait” means that the longest dimension is vertical; “landscape” means that the longest dimension is horizontal.

• Cut a hole in the panel or drywall. See section 1.4.1,

File any rough edges smooth, especially on the face of the panel. 1.4.2 Installing the Panel Mount Terminal

“Cutout for Panel Mount Configuration” or section 1.4.3, “Cutout for Drywall Mount Configuration” for specifications.

NOTE: Use of an anti-static strap is recommended when performing installation and maintenance.

• Install the QTERM-G70 terminal in the panel or drywall.

Take the following steps to install the terminal. Refer to the illustrations on the next page.

See section 1.4.2, “Installing the Panel Mount Terminal” or section 1.4.4, “Installing the Drywall Mount Terminal” for instructions.

1.

Verify that the panel surface around the cutout is clean and free of rough edges. A gasket built into the terminal will seal against this surface. Dirt or imperfections on the panel may prevent a proper seal.

2.

Place the terminal into the panel cutout and verify that the terminal is oriented correctly. The touch screen legend may indicate the orientation. If not, you can deter-

• Connect cables to the terminal. Verify that the thumb screws are tight or the locks snapped into place for each cable used. Apply DC power to the QTERM-G70 terminal See section 1.4.5, “Applying Power” for information.

QSI Corporation Fax 801-466-8792 Web www.qsicorp.com Phone 801-466-8770

Page 15

QSI Qlarity-based Terminal Hardware mine which side should be at the top by the position of the serial port on the back panel as follows: Landscape: when looking at the front of the unit, the back panel serial port(s) should be on the bottom of the terminal. Portrait: when looking at the front of the unit, the back panel serial port(s) should be on the left side of the terminal.

7

3.

On the back of the panel, place the terminal mounting bracket against the back of the terminal, and align it with the back panel.

4.

Fasten the six screws (supplied with the terminal).

1.4.3 Cutout for Drywall Mount Configuration The QTERM-G70 terminal with the drywall mount configuration will accommodate drywall thicknesses of 7 mm to 18 mm. The panel may be cut by using the template supplied with the unit or by using the dimensions given below. To use the template, simply identify where the unit is to be placed on the wall and tape the template up into position. Next cut along the indicated line. The cutout dimensions with appropriate tolerances are as follows: Landscape: Horizontal Vertical

199 ± 1 mm 145 ± 1 mm

Portrait: Horizontal Vertical

145 ± 1 mm 199 ± 1 m

NOTE: Care must be taken to not to make the cutout oversize. 1.4.4 Installing the Drywall Mount Terminal NOTE: Use of an anti-static strap is recommended when performing installation and maintenance. Take the following steps to install the terminal. Refer to the illustration below.

QSI Corporation Fax 801-466-8792 Web www.qsicorp.com Phone 801-466-8770

Page 16

8

1.

QSI Qlarity-based Terminal Hardware

Verify that the unit is in the correct orientation. The touchscreen legend may indicate the orientation. If not, the top side may be identified by the position of the serial port(s) on the back panel as follows: Landscape: when looking at the front of the unit, the back panel serial port(s) should be on the bottom of the terminal. Portrait: when looking at the front of the unit, the back panel serial port(s) should be on the left side of the terminal.

2.

Connect all necessary cables to their correct places on the back panel.

3.

Insert the terminal into the cutout in the wall. If the unit will not fit into the opening, check to make sure that the cam locks on the top and bottom are not protruding from the case.

4.

Tighten all four screws on the front panel until the unit seats firmly in the cutout. The screws should be tightened approximately 2-3 full turns after a slight resistance is felt.

NOTE: Do not over tighten the screws Doing so will damage the cam locks and the unit will no longer mount securely into the wall. 5.

Using the supplied legend, remove the adhesive back and install on the front of the unit over the top of the four screws as indicated in the figure.

1.4.4.1 Removing the Drywall Mount Terminal Removal of the G70 terminal requires the replacement of the outer legend. Replacements may be ordered from QSI. 1.

Remove the outer legend on the front of the unit to expose the four mounting screws.

2.

Turn the screws counterclockwise until they begin to back out of the unit.

3.

Gently pull the terminal from the wall cutout.

1.4.5 Applying Power Power is supplied to the QTERM-G70 terminal via the primary serial port connector. Refer to section 1.2.1, “Serial

Ports” for the pin assignments for power and ground. DC power must be in the range of 8 to 26 volts (the current will vary depending on the input voltage; see table below QTERM-G70 power must come from an SELV (Safety Extra Low Voltage) power CAUTION source and should have a current limit on its output of 5 Amperes. It must provide a minimum of 8 volts DC power and be limited to a maximum of 26 volts DC. Limiting may be inherent to the supply or may be provided by supplementary overcurrent devices. If the QTERM-G70 does not respond or exhibits abnormal behavior on power up, disconnect power and contact QSI for technical support. Current Consumption Terminal

12 VDC 24 VDC

PoE

Standard unit (color, no options, idle)

400 mA

240 mA

120 mA

Standard TFT unit (TFT, no options, idle)

675 mA

350 mA

190 mA

Standard unit, active add 90 mA add 40 mA add 15 mA

Standard TFT unit, active add 90 mA add 50 mA add 15 mA

With keyboard option and keyboard attached add 70 mA add 35 mA

N/A

With Ethernet option and connection add 40 mA add 20 mA

N/A

1.4.6 Powering On the Terminal for the First Time When you connect power to the QTERM-G70 terminal, it automatically loads the application saved in flash memory into RAM memory and displays the application. If no application is present, the terminal display may be blank but the backlighting verifies it is powered on. When you power on the terminal for the first time, a demo program (or a special application custom designed for your company) loads. The demo program will help you verify that the terminal is operating properly. Follow the on-screen prompts or any documentation accompanying the program to guide you through tests or demonstrations designed to verify terminal operation.

QSI Corporation Fax 801-466-8792 Web www.qsicorp.com Phone 801-466-8770

Page 17

QSI Qlarity-based Terminal Hardware

Once you have verified that the terminal is functioning properly, refer to Chapter 5, “Power On Setup” for information on configuring your terminal. The Power On Setup utility includes functions to do the following:

• Change orientation of the terminal (portrait or landscape) • Download a new user application to the terminal • Select the application mode • Set up communications settings for the terminal • Adjust display contrast or backlight • Enter network (Ethernet) settings • Enter/change password (if used) • Set the real time clock

QSI Corporation Fax 801-466-8792 Web www.qsicorp.com Phone 801-466-8770

9

Page 18

10

QSI Qlarity-based Terminal Hardware

QSI Corporation Fax 801-466-8792 Web www.qsicorp.com Phone 801-466-8770