Page 53

RF Beep Duration Feature is specific to scanner ONLY The duration of time that an ACK beep is sounded is selectable using this setting. RF beep duration can be set in increments of 10 ms (tolerance of +/- 10%) from 0 to 2.55 seconds.

SET -------------------------------------------

Set RF Beep Duration

---------

Scan three digits representing the desired duration using the Number Pad in Appendix B, padded with leading zeros (example: 008 = 80ms, 025 = 250ms, 100 = 1 second, etc.), then scan the END bar code.

END ------------------------------------------

Systems Manual

49

Page 54

Radio Transmit Power Feature is applicable to scanner and Base Station.

NOTE

Remember, programming changes to the Base Station have no effect until the new configuration is downloaded via the feature Transmit Scanner Configuration to Base Station on page 33.

The power level at which the radio signal is transmitted between the devices is selectable to be either low or high. This setting allows adjustment to a low setting to minimize potential radio interference caused by communication between the devices, or provides a high setting to increase the signal power which would enable clearer communication over longer distances.

SET -------------------------------------------

Radio Transmit Power = Low ---------

Radio Transmit Power = High ---------

END ------------------------------------------

50

PowerScan™ RF Scanner

Page 55

RF Channel Selection Feature is applicable to scanner and Base Station.

NOTE

Channel selection bar codes are of the type C programming sequence category (see Programming Sequence on page 36), and do not require you to scan accompanying SET or END bar codes.

Radio communications between the handheld scanner and its linked Base Station can be carried over one of ten different allowable frequencies (channels). Select alternate channels to improve communications between devices in noisy RF environments.

Available channel frequencies will vary according to the country/model of the scanner. NOTE When a new channel is selected, the scanner sends a change-of-channel message to the Base Station. After the Base Station has acknowledged receipt of the message, both the scanner and the Base Station switch their radio channels to the new channel (reference LED and Beeper Indications for information regarding scanner and Base Station acknowledgement signals at this point). All further communication is done on the new channel.

NOTE

Systems Manual

Any other scanner that happens to be linked to that Base Station will be unable to communicate with the Base Station until it has switched to the new channel. To accomplish this, scan the Base ID label with each scanner you desire to be linked to the Base Station. This action will automatically set each scanner to the correct new channel.

51

Page 56

Select Radio Channel 0 ---------

Select Radio Channel 1 ---------

Select Radio Channel 2 ---------

Select Radio Channel 3 ---------

Select Radio Channel 4 ---------

Select Radio Channel 5 ---------

Select Radio Channel 6 ---------

Select Radio Channel 7 ---------

Select Radio Channel 8 ---------

Select Radio Channel 9 ---------

52

PowerScan™ RF Scanner

Page 57

Transmission Retries Before Message Timeout

Feature is applicable to scanner and Base Station.

NOTE

Remember, programming changes to the Base Station have no effect until the new configuration is downloaded via the feature Transmit Scanner Configuration to Base Station on page 33.

When the scanner attempts to transmit data to the Base Station, communication may not always occur on the first try due to interference, signals from other scanners in the queue, etc.. This setting defines the number of transmission retries the scanner/Base Station will attempt before the message gives up tryng to successfully resend/transmit the message (times out). If the specified retry count is exceeded, the scanner will sound a transmission error beep (when transmission error beep is enabled). In a noisy RF environment, a large number of retries may allow a transmission to get through to the Base Station, but at the cost of increased time-out (should the transmission fail). To maximize battery life, set this feature to the lowest optimal number of retries. Selectable range for this setting is 0-15 retries.

SET -------------------------------------------

Systems Manual

0 Retries

---------

1 Retry

---------

53

Page 58

54

2 Retries

---------

3 Retries (recommended)

---------

4 Retries

---------

5 Retries

---------

6 Retries

---------

7 Retries

---------

8 Retries

---------

9 Retries

---------

PowerScan™ RF Scanner

Page 59

10 Retries

---------

11 Retries

---------

12 Retries

---------

13 Retries

---------

14 Retries

---------

15 Retries

---------

END ------------------------------------------

Systems Manual

55

Page 60

Wait Time for ACK Feature is applicable to scanner and Base Station.

NOTE

Remember, programming changes to the Base Station have no effect until the new configuration is downloaded via the feature Transmit Scanner Configuration to Base Station on page 33.

This setting defines a time period allowed once the scanner has sent data to the Base Station for that Base Station to send an acknowledgement (ACK) back to the scanner, signalling receipt of the data. This feature is used to streamline the scanning speed of your system. The range for this delay is 0.08 - 2.55 seconds in 10ms increments.

Selecting longer values for this feature will decrease the battery life between charges. NOTE

SET -------------------------------------------

Set Wait Time for ACK ---------

Scan three digits representing the desired delay using the Number Pad in Appendix B. Be sure the number is padded with leading zeros (example: 008 = 80ms, 025 = 250ms, 100 = 1 second, etc.), then scan the END bar code.

END ------------------------------------------

56

PowerScan™ RF Scanner

Page 61

Wait Time For Scanner Power Shutdown

Feature is specific to scanner ONLY To conserve battery life, the handheld scanner can be automatically shut down when it has not been in use for a given period. A trigger pull or other stimulus will then be required to reactivate the scanner. The idle duration determines how long the scanner stays on/active after each use. Range for this feature is a setting of 1 to 120 seconds in one-second increments. A setting of one second is recommended.

Selecting higher values for this feature will effect the length of battery life. NOTE

SET -------------------------------------------

Set Wait Time for Scanner Power Shutdown ---------

Scan three digits representing the desired delay using the Number Pad in Appendix B. Be sure the number is padded with leading zeros (example: 001 = 1 second, 025 = 25 seconds, 100 = 100 seconds, etc.), then scan the END bar code.

END ------------------------------------------

Systems Manual

57