Page 44
Enable Keyboard Wedge --------Type Aa
Enable Keyboard Wedge Type B ---------
Enable Keyboard Wedge Type C ---------
Enable Keyboard Wedge Type D ---------
Enable Keyboard Wedge Type E ---------
Enable Keyboard Wedge Type F --------Enable Keyboard Wedge Type G ---------
Enable Keyboard Wedge Type H ---------
Enable Keyboard Wedge Type I --------Enable Keyboard Wedge Type J ---------
END ------------------------------------------ a. See Table 6 for the specific interfaces supported by each of the keyboard types listed above. See the following section Universal Wedge Terminal Selection to enable that interface type.
40
PowerScan™ RF Scanner
Page 45
Table 6. Keyboard Wedge I/F Selection
Systems Manual
I/F Type
PCs Supported
A
PC/XT w/Alternate Key Encoding
B
AT, PS/2 25-286, 30-286, 50, 50Z, 60, 70, 80, 90 & 95 w/Alternate Key Encoding
C
PS/2 25 and 30 w/Alternate Key Encoding
D
PC/XT w/Standard Key Encoding
E
AT, PS/2 25-286, 30-286, 50, 50Z, 60, 70, 80, 90 & 95 w/Standard Key Encoding
F
PS/2 25 and 30 w/Standard Key Encoding
G
IBM 3xxx w/122 keyboard
H
IBM 3xxx w/102 keyboard
I
PS/55 5530T w/104 keyboard
J
NEC 9801
41
Page 46
Universal To activate the Universal Wedge interface, follow these instructions: Wedge 1. Scan the START bar code. Terminal 2. Determine the I.D. of the terminal/keyboard. Refer to the TerSelection minal/Keyboard Settings section below for more information plus a listing of the most common keyboard I.D.s. 3.
Scan the Activate Universal Wedge Interface bar code.
4.
Use the Universal Wedge Number Pad to scan in the digits for the keyboard I.D. number you determined in step 2.
5.
Scan the END bar code.
START----------------------------------------
Activate Universal Wedge Interface ---------
Scan the digit(s) representing the desired keyboard I/F type using the Universal Wedge Number Pad, then scan the END bar code.
END ------------------------------------------
Terminal/ The list below contains the most common terminal/keyboard types. If Keyboard your specific system is not listed below, consult the Universal KeySettings board Wedge Connectivity Guide for a detailed listing of terminal/ keyboard types. A copy of the guide can be obtained from the internet at www.pscnet.com, or call your dealer for customer support information.
42
Keyboard
Terminal I.D.
High Speed PC/AT, PS2
591
PC AT, PS2
11
MAC
25
PowerScan™ RF Scanner
Page 47
Universal The default communication mode (factory settings) is Keyboard Wedge Wedge Number of PC AT (keyboard I.D. 11). Use the codes on this page to select the Pad I. D. corresponding to your computer or terminal (reference the Universal Keyboard Wedge Connectivity Guide for this product or call PSC Customer Support).
0 →
1 →
2 →
3 →
4 →
5 →
6 →
7 →
8 →
9 →
Systems Manual
43
Page 48
RF Beeper The RF version of the scanner exhibits different beeper behavior than Settings standard (non-RF) models. For more information about RF beeper indications, see the section, LED and Beeper Indications.
NOTE
The following descriptions highlight configurable beeper functions that are unique to RF handheld scanners. All other beeper functions supported by the standard version of the scanner are supported by RF models.
Good Read Beep, When good read beep is enabled, this beep sounds at the time the scanner successfully reads a bar code. Selectable settings for the good read beep include: •
RF When to Beep
•
Beeper Volume
•
Good Read Beep Frequency
•
Beep Duration
ACK Beep, The scanner can sound an acknowledgement (ACK) beep to indicate when the Base Station has acknowledged to the scanner that is has received a successful data transmission from the scanner. This beep is also sounded upon a successful channel change sequence or a successful configuration transmission. Transmission Error Beep, Another selectable indicator beep is the transmission error beep. This beep sounds to indicate an error in transmission between the RF devices. Link Beep, The handheld scanner will sound a special link beep upon successfully linking with a Base Station. This indication cannot be disabled and is not programmable, other than that it shares the same Beeper Volume setting as other beeper indications set using that feature. Unlink Beep, When a scanner is successfully unlinked from a Base Station, a unique unlink beep is sounded. This beep is not programmable, and also sounds at the same volume set for Beeper Volume.
44
PowerScan™ RF Scanner
Page 49
RF When to Beep Feature is specific to scanner ONLY Several options are available to specify how the RF handheld scanner will beep to indicate a good read. Settings are based on the enable/disable status desired for three selectable beep indications: •
Good Read Beep
•
Acknowledgement (ACK) Beep
•
Transmission Error Beep
The available options are described and numbered in Table 7 to correspond with the programming bar codes provided for this feature.
These settings supersede any settings made using the generic "When to Beep" feature listed in the PowerScan Programming Manual. NOTE
Table 7. RF When to Beep Options
Systems Manual
#
Good Read Beep
ACK Beep
Transmission Error Beep
0
Disabled
Disabled
Disabled
1
Disabled
Disabled
Enabled
2
Disabled
Enabled
Disabled
3
Disabled
Enabled
Enabled
4
Enabled
Disabled
Disabled
5
Enabled
Disabled
Enabled
6
Enabled
Enabled
Disabled
7
Enabled
Enabled
Enabled
45
Page 50
RF When to Beep Options (continued) SET -------------------------------------------
When to Beep Option #0
---------
When to Beep Option #1
---------
When to Beep Option #2
---------
When to Beep Option #3
---------
When to Beep Option #4
---------
When to Beep Option #5
---------
When to Beep Option #6
---------
When to Beep Option #7
---------
END ------------------------------------------
46
PowerScan™ RF Scanner
Page 51
RF Beeper Volume Feature is specific to scanner ONLY The volume at which the beeper sounds for ACK, transmission error, link, or unlink beeps (but not the good read beep1) are all affected by this setting. Select volume #1 (25% duty cycle), volume #2 (35% duty cycle), or volume #3 (50% duty cycle).
SET -------------------------------------------
RF Beeper Volume #1
---------
RF Beeper Volume #2
---------
RF Beeper Volume #3
---------
END ------------------------------------------
1. Good read beep volume is selectable via the features available in the PowerScan Programming Manual (P/N R44-1840). See References for information about acquiring other manuals.
Systems Manual
47
Page 52
RF Beeper Frequency Feature is specific to scanner ONLY This setting affects the frequency at which the ACK beep is sounded, and is independent of the frequency setting for the good read beep. When the ACK beep is sounded at a different frequency than the good read beep, this can provide a clearer distinction between the tones. Select low frequency (760Hz), medium frequency (1250Hz), or high frequency (2400Hz).
SET -------------------------------------------
RF Beeper Low Frequency
---------
RF Beeper Medium Frequency
---------
RF Beeper High Frequency
---------
END ------------------------------------------
48