Page 35

RF Programmable Features Use the special programming bar codes contained in this section to set features that are unique to RF models of PowerScan™ bar code scanners. To program other features that are common to all models, use one of the following: - Configurator Express™ On-Screen Programming Kit - PowerScan™ Programming Guide

See References on page 1 for more information about how to obtain kits, software and manuals for this product. NOTE Programming features included in this manual are:

Systems Manual

•

Interface (I/F) Selection

•

RF Beeper Settings

•

Radio Transmit Power

•

RF Channel Selection

•

Transmission Retries Before Message Time-out

•

Wait Time for ACK

•

Wait Time For Scanner Power Shutdown

•

Wait Time Between Retries of Failed Transmission

•

HACK Transmit Options

•

Wait Time For HACK From Host

•

Drop Links on Reset Option

•

Drop Oldest Links Option

•

Common Configuration

•

Set Maximum Linked Scanners

•

Source-Radio Identification (ID)

•

Low Battery LED Indication

31

Page 36

Programming The RF system's programmable feature settings can be modified to Overview accommodate your unique requirements. Listed below are the various methods to configure scanner and Base Station units:

Base Stations and the scanners linked to them must possess compatible configuration files. NOTE Scanner 1.

The Base Station’s configuration files can be automatically downloaded to the scanner at the time of linking. See the sections, Linking the Scanner to a Base Station and Common Configuration for more details.

2.

The easiest, most comprehensive way to program the scanner is to use the Configurator Express™ On-Screen Programming Kit. See References for more information about this product.

3.

The scanner can be configured using special programming bar codes like those contained in this section. For the most part, the programming instructions and bar codes on the following pages address this method of scanner configuration.

If you program the scanner using any of the methods above, the scanner will store the changes until reprogrammed or returned to factory defaults. NOTE

32

PowerScan™ RF Scanner

Page 37

Base Station Base Station configuration is primarily performed by first programming a scanner with the desired options, then downloading the configuration to the Base Station from that scanner.

CAUTION

Verify that the scanner and Base Station host interface types (RS-232, Keyboard Wedge, etc.) are matched before attempting to download any configuration files or perform any custom programming sessions. Go to Interface (I/F) selection on page x and set the scanner to the Base Station’s I/F type.

Use the bar code below to overwrite a Base Station’s configuration file.

CAUTION

After the Base Station receives the entire configuration, it will drop all links to scanners other than the scanner transmitting the new configuration. This will require the user to relink all other scanners (see Linking the Scanner to a Base Station). Prior to the time of relinking, it is advisable to consider enabling the feature, Common Configuration, ensuring that the Base Station will attempt to share the new configuration with scanners as they are linked.

Transmit Scanner Configuration to Base Station ---------

What Is The scanner must be placed into the Programming Mode state in order Programming to accept programming commands. When programming using the bar Mode? code labels in this manual, the scanner is placed in Programming Mode by scanning the "SET" label at the top of most programming feature pages.

While in Programming Mode, the scanner only recognizes special programming bar codes. See the section, LED and Beeper Indications for information about scanner indications while in Programming Mode.

Systems Manual

33

Page 38

The Scanner programming allows you to customize the scanner’s configuProgramming ration to match your specific needs. A typical programming session is Session conducted as follows: 1.

Scan the SET bar code at the top of the page. The scanner will emit one beep, indicating it has read the bar code and the green LED will flash on and off slowly while the scanner remains in Programming Mode. Normal scanning functions are disabled.

2.

Scan the programming bar codes(s) to make the desired changes. With few exceptions, the scanner will emit a triple beep each time you scan a valid programming bar code..

NOTE

NOTE 3.

Not all features are available for all interfaces. The scanner will sound an error tone when scanning programming bar codes for features that cannot be used with the currently active interface. Only features supported by the currently active interface will be implemented. If you are enabling a different interface (I/F), we suggest/recommend that you change the I/F designation first and then proceed with other changes. Once a bar code is scanned that changes the scanner's I/F, all previous I/F configuration items scanned in the programming session are lost.

Scan the END label at the bottom of the page to save any new settings and exit Programming Mode. The scanner will sound a beep and reset upon exiting Programming Mode, and the green LED will return to its usual state (on steady or off). The scanner will not exit Programming Mode unless the END bar code is scanned or the scanner’s battery is removed. Removing power during Programming Mode, before scanning the END label, will cause all new settings to be ignored. On power-up, the scanner will return to previous settings.

34

PowerScan™ RF Scanner

Page 39

4.

Systems Manual

Maintain a record of all changes made to ensure that you know if the original factory settings have been changed. Use the following table to log your custom configuration changes.

RF Programmable Feature

Factory Default Setting

RF When to Beep

Option 7

RF Beeper Volume

Vol 3

RF Beeper Frequency

High

RF Beep Duration

50ms

Radio Transmit Power

High

RF Channel Selection

Channel 1

Transmission Retries Before Message Timeout

3 Retries

Wait Time for ACK

200ms

Wait Time for Scanner Power Shutdown

1 Second

Wait Time Between Retries of Failed Transmission

90ms

HACK Transmit Options

HACK upon Base Station transmission to host

Wait Time for HACK From Host

1 Second

Drop Links on Reset Option

Disable

Drop Oldest Links Option

Enable

Your Setting

Comment

35

Page 40

Common Configuration

Disable

Set Maximum Linked Scanners

8

Source-Radio Identification (ID)

Don’t Include

Low Battery LED Indication

Enable

Programming To modify a scanner feature (item), the programming bar codes conSequence tained in this manual must be scanned in a given sequence depending upon the feature being programmed (as shown in Table 5). There are three possible programming sequences: A. Programming sample A (the most commonly used format) demonstrates how three bar codes are scanned in sequence to do the following: 1.

Place the scanner in Programming Mode (SET bar code).

2.

Scan the Item Tag1 that will enable the new feature.

3.

End the programming session and reset the scanner (END bar code).

B. Sample B provides an example of a programming feature requiring the entry of a range value. Like sample A, the scanner is placed in Programming Mode and an Item Tag 1 is scanned. Then, a value must be entered before ending the programming session. In the example, three digits must be scanned from the number pad in Appendix B. This type of format, requiring a total of as many as six programming bar codes, is necessary to allow flexible programming with larger item value numeric ranges. C. The programming sequence shown in example C requires scanning of a single, extended length bar code. This special programming bar code contains all the data necessary to enter Programming Mode, set the Item Tag1 and Item Value, and exit Programming Mode (all in one step).

1. An “Item Tag” is a term used to describe an assigned number, which is encoded in a programming bar code, that toggles (selects, enables, disables, etc.) a specific programming feature.

36

PowerScan™ RF Scanner

Page 41

Table 5. Programming Sequence

A

SET

ITEM TAG

1

2

3

SET

ENABLE NEW FEATURE

END

1

2

ITEM VALUE

345

END/RESET

6

0

B SET

C

Systems Manual

ENABLE NEW FEATURE USING THE FOLLOWING SETTINGS...

0

8

END

1 ONE BAR CODE CONTAINS SET + ITEM TAG + ITEM VALUE + END

37

Page 42

Scanner vs. Some programming features are specific to either the scanner (handBase Station held unit) or the Base Station, while others are applicable to both. Each Features feature in this manual is marked with an indicator as to which unit(s) it is applicable.

Feature is specific to scanner ONLY

Feature is specific to Base Station ONLY

Feature is applicable to scanner and Base Station.

NOTE

38

When programming using bar codes via the scanner, it is important to remember that features affecting the Base Station WILL NOT be enabled until the new configuration is downloaded to the Base Station using the feature Transmit Scanner Configuration to Base Station on page 33.

PowerScan™ RF Scanner

Page 43

Interface (I/F) It is very important that the scanner and Base Station are each configSelection ured to operate with the same interface (I/F) type as the host terminal.

NOTE

The Base Station uses a “smart” cable, which automatically sets the Base Station to the correct I/F upon power-up and connection to the appropriate host.

SET -------------------------------------------

Enable Wand Emulation ---------

Enable Standard RS-232

---------

Enable Wincor Nixdorf RS-232 ---------

Systems Manual

Enable IBM Port 5B

---------

Enable IBM Port 9B

---------

Enable IBM Port 17

---------

Enable IBM Port E

---------

39