Page 62

Wait Time Between Retries of Failed Transmission

Feature is applicable to scanner and Base Station.

NOTE

Remember, programming changes to the Base Station have no effect until the new configuration is downloaded via the feature Transmit Scanner Configuration to Base Station on page 33.

In conjunction with the previous feature, TRANSMISSION RETRIES BEFORE MESSAGE TIME-OUT, this feature defines the duration of time the system must wait before re-trying a transmission of data between the scanner and the Base Station. Consideration for this setting would be to ensure that enough time elapses between tries to avoid encountering the source of the original transmission conflict, while being short enough to avoid causing a substantial increase in the time required to successfully transmit the message. Wait range can be set from 5ms to 255ms in one-millisecond increments, and is multiplied by the amount of retries selected via the feature, TRANSMISSION RETRIES BEFORE MESSAGE TIME-OUT (TRBMTO) to determine the total duration. For example if this feature (WAIT TIME BETWEEN RETRIES OF FAILED TRANSMISSION) is selected to be 80 ms, and TRBMTO feature is selected to be 3, the resulting total duration between retries would be 80 x 3, or 240ms total.

58

PowerScan™ RF Scanner

Page 63

SET -------------------------------------------

Set Wait Time Between Retries of Failed Transmission ---------

Scan three digits representing the desired delay using the Number Pad in Appendix B. Be sure the number is padded with leading zeros (example: 005 = 5ms, 065 = 65ms, 250 = 250ms, etc.), then scan the END bar code.

END ------------------------------------------

Systems Manual

59

Page 64

HACK Transmit Options Feature is applicable to scanner and Base Station.

NOTE

Remember, programming changes to the Base Station have no effect until the new configuration is downloaded via the feature Transmit Scanner Configuration to Base Station on page 33.

A Host Acknowledgement (HACK) message is a signal sent to the scanner via the Base Station indicating the host has received bar code data previously transmitted by that scanner. This feature determines when the Base Station should send the HACK to the scanner. Choices are:

60

•

Send HACK as soon as the Base Station receives the scanner’s transmission. This option is recommended for installations where multiple scanners are linked to one Base Station.

•

Send HACK as soon as the Base Station completes transmission to the host. This option is recommended for installations where only a single scanner is linked to one Base Station.

•

Send HACK after the host transitions the CTS line from inactive to activate (using CTS scan control). RS-232 ONLY.

•

Send HACK after host returns ACK to Base Station. RS-232 with ACK/NAK turned on ONLY.

PowerScan™ RF Scanner

Page 65

SET -------------------------------------------

HACK upon receipt of scanner transmission ---------

HACK upon Base Station transmission to the host ---------

HACK after host transitions CTS line (RS-232 ONLY) ---------

HACK after host returns ACK (RS-232 ONLY) ---------

END ------------------------------------------

Systems Manual

61

Page 66

Wait Time For HACK From Host

Feature is specific to scanner ONLY This setting specifies the time the scanner must wait to receive a HACK message back from the host before giving up and registering a transmission error. Selectable range for this wait time is 20ms to 5.1 seconds in 20ms increments. It is recommended that this value be set at no less than one second.

NOTE

Host turnaround (ACK) time is variable. This item (HACK) should be set based on settings for the features Wait Time for ACK and Transmission Retries Before Message Time-out. For example if ACK is set to one second and retries are set to three, HACK should be set at three seconds.

SET -------------------------------------------

Set Wait Time For HACK

---------

Scan three digits representing the desired delay using the Number Pad in Appendix B. Be sure the number is padded with leading zeros (example: 001 = 20ms, 100 = 2 seconds, 255 = 5.1 seconds, etc.), then scan the END bar code.

END ------------------------------------------

62

PowerScan™ RF Scanner

Page 67

Drop Links on Reset Option Feature is specific to Base Station ONLY

NOTE

Remember, programming changes to the Base Station have no effect until the new configuration is downloaded via the feature Transmit Scanner Configuration to Base Station on page 33.

When enabled, this option causes the Base Station to drop its links to any and all scanners whenever power is reset/cycled. This provides a simple way to ensure that when reconfiguring a system, scanners do not need to be located and individually unlinked.

SET -------------------------------------------

Drop all links on reset (ENABLE) ---------

Do not drop all links on reset (DISABLE) ---------

END ------------------------------------------

Systems Manual

63

Page 68

Drop Oldest Links Option Feature is specific to Base Station ONLY

NOTE

Remember, programming changes to the Base Station have no effect until the new configuration is downloaded via the feature Transmit Scanner Configuration to Base Station on page 33.

This feature can be enabled to better manage the linking of new scanners to a multi-point system. Here’s how it works: When a new scanner is linked to a Base Station that is already linked to its maximum amount of scanners, an earlier-linked scanner that has been inactive for the longest period of time will be automatically unlinked from the system to make room for the new scanner. When this feature is disabled, scanners can be linked up to the maximum number set via the programming feature, Set Maximum Linked Scanners, or the default maximum, which is eight scanners. Attempts to link additional scanners beyond these limits will fail.

SET -------------------------------------------

Drop oldest links (ENABLE)

---------

Do not drop oldest links (DISABLE) ---------

END ------------------------------------------

64

PowerScan™ RF Scanner

Page 69

Common Configuration Feature is applicable to scanner and Base Station.

NOTE

Remember, programming changes to the Base Station have no effect until the new configuration is downloaded via the feature Transmit Scanner Configuration to Base Station on page 33.

When this option is enabled, the Base Station attempts to share its configuration with a scanner as that scanner links to the Base Station. If, during linking, a scanner’s configuration file does not match the Base Station’s current settings, the Base Station attempts to transmit to the scanner and overwrite the configuration file with its own.

CAUTION

Since a new/replacement scanner may have been shipped with a custom configuration or may have been modified with other special programming, it may not be desirable to download a potentially older configuration from an existing Base Station. In this case, consider uploading the scanner’s newer configuration to the Base Station instead.

If the need is to share the scanner’s configuration files to the Base Station, use the Transmit Scanner Configuration to Base Station bar code. Base Station on page 33.

SET -------------------------------------------

ENABLE Common Configuration

Systems Manual

---------

65

Page 70

DISABLE Common Configuration

---------

END ------------------------------------------

66