Page 241
Chapter 8: Terminal Accessories Mounting The Cradle
8.8.4 Mounting The Cradle •
Mount the main chassis using four #8-32 machine screws and four #8-32 KEPS nuts.
Note: If mounting directly to wood, use four #8 wood screws. •
Replace the plastic cradle, securing it with two hex bolts (one per side).
•
If a pedestal mount is used, adjust the angle of the cradle to the optimum viewing angle, and securely tighten the hex and wing screws.
8.8.5 Installing The Cables Before installing the cables between the cradle and other devices, consider the following: •
Ensure that drilling holes will not damage the vehicle or its wiring.
•
Protect cable runs from pinching, overheating, and physical damage.
•
Use grommets to protect cables that pass through metal.
•
Use plastic straps to prevent cables and connectors from loosening.
•
Keep cables away from heat sources, grease, battery acid, and other potential hazards.
•
Keep cables away from control pedals and other moving parts that may damage the cables or interfere with the operation of the vehicle.
•
Leave enough extra cable so that the terminal can be easily removed.
Note: Where applicable, ensure that the unit is mounted inside the roll cage.
8.8.6 Connecting A Cable When a picker cradle is ordered with a peripheral cable: • Connect one end of the cable to the accessory. • Connect the other end to the 7035 itself. • Secure the cable to avoid physical injury or damage to the cable.
Teklogix 7035, 8255 & 8260 Terminals User Manual
215
Page 242
Chapter 8: Terminal Accessories Connecting The Power Source
8.8.7 Connecting The Power Source Model 7937A does not require a power connection. Model 7937B and 7937C have short power cords and connectors. The extension power cable (PN 13985) joins the cradles to a power source. If an unfused power source must be used, install the fuse assembly (PN 19440) provided with PN 13985. To connect the fuse assembly, •
Push the male connector of the fuse assembly into the female connector at the positive (red) lead of the power cable.
•
Connect the red lead to the positive side of the battery. Connect the black lead to the negative side of the battery.
Warning:
Do not reverse the polarity or connect to a voltage outside the specified range. Note also that the fuse should be UL approved.
8.8.8 Attaching A Port Replicator A port replicator, PN 21658, is an accessory which extends the 28-pin peripheral port connection for the 7035 terminal to an identical 28-pin fixed connector. The port replicator mounts on the underside of any of the 7035 picker cradles with 2 screws. A dsub9 COM port is also included. It is equipped with transmit, receive, ground, CTS and RTS signals. When a port replicator is attached to a cradle, you can, for example, attach a scanner to the 28-pin connector and a serial printer to the dsub9 connector.
8.8.9 Picker Cradle Maintenance Picker cradles requires little maintenance. • Ensure that the inside of the plastic cradle is clear of any debris. • Avoid using strong solvents.
216 Teklogix 7035, 8255 & 8260 Terminals User Manual
Page 243
Chapter 8: Terminal Accessories Inserting And Removing The 7035 Terminal
8.8.10 Inserting And Removing The 7035 Terminal The picker cradle is comprised of two parts – a fixed outer metal chassis that is secured to the vehicle or work surface, and a moveable plastic cradle in which the 7035 terminal is placed. The plastic cradle tilts forward so that the terminal can be inserted or removed, and it tilts back to lock the terminal.
Figure 8.3 Unpowered Picker Cradle 7937A To insert the 7035 in the plastic cradle: •
Using your thumb and first finger, depress the two raised plastic buttons located on the top of the cradle.
•
Pull the plastic carrier forward until a stop is felt to ensure that the locking tabs are fully withdrawn from the plastic cradle.
•
Push the 7035 terminal into the plastic cradle.
•
Push the plastic cradle back, snapping it into place.
To remove the 7035 from the plastic cradle: •
Reverse the above procedure.
Teklogix 7035, 8255 & 8260 Terminals User Manual
217
Page 244
Chapter 8: Terminal Accessories Picker Cradle LED Indicator
8.8.11 Picker Cradle LED Indicator LED Colour
Conditions
Green/Orange
• Cradle is unlocked. • Cradle is locked. • Terminal is ON, and battery pack PN 20605-003 is installed. • Battery cells are disconnected within the battery pack, and the terminal is powered from cradle (indefinite usage). • Cradle is locked. • Terminal is OFF. • Battery pack PN 20605-003 is installed. • Battery is charging and capacity is less than 80% charged. • Cradle is locked. • Terminal is OFF, and battery pack PN 20605-003 is installed. Battery not charging because of incorrect data (charge fault). • Terminal is not inserted in cradle. • Cradle is locked. • Terminal is OFF. • Battery pack PN 20605-003 is installed. • Battery is charging and capacity is more than 80% charged. The unit is ready for mobile use. Note: If the terminal is turned “on” while charging, the terminal will signal the cradle to immediately stop the charge process. • Cradle is locked. • Terminal is OFF. • Battery pack PN 20605-003 is installed. • Battery temperature is lower than 10˚ C or higher than 45˚ C. Charging will begin when battery within correct temperature range. • Cradle is locked. • Terminal is ON and PN 20605-003 battery is installed. • Terminal running off battery pack, not cradle.
Green
Orange
Red
Flashing Green
Flashing Orange
Flashing Red
Table 8.3 Charger Indicators
8.8.12 Specifications 8.8.12.1 Physical Dimensions (W x H x D) Plastic cradle Metal chassis Weight
115 x 203 x 115 mm (4.5" x 8.0" x 4.5") Jet Black, Bayer Makroblend EL-700 16 AWG cold rolled steel – black enamel over yellow chromate plate 1.4 kg (3.09 lbs.)
218 Teklogix 7035, 8255 & 8260 Terminals User Manual
Page 245
Chapter 8: Terminal Accessories Environmental
8.8.12.2 Environmental Operating temperature Storage temperature Charge mode Discharge mode Relative humidity Shock Vibration
-20˚ C to 45˚ C (-4˚ F to 113˚ F) -40˚ C to 60˚ C (-40˚ F to 140˚ F) 10˚ C to 45˚ C (50˚ F to 113˚ F) -20˚ C to 60˚ C (-4˚ F to 140˚ F) 10 to 90% (non-condensing) 25 G with an 11 ms rise-time on all axes Random, 3-axis, 1.5g RMS, 4-500 Hz, 60 minutes.
8.8.12.3 Electrical Target pack type Charge sites Charge mode Operation under charge Input power Input connector Electrical interface Pin-out
PN 20605-003 1 site for in-unit charging. Fast charge CCCV Not permitted. Charging will stop when terminal is turned ON. Model 7937B – 11 - 16 VDC 36 W max. Model 7937C – 10 - 55 VDC 36 W max. AMP type CPC #206153-1 on flying lead. 4 spring-loaded heavy-duty ‘pogo type’ pins in base of unit. +BAT, -BAT. TEMP, DATA
8.8.12.4 Powered Cradle Battery Pack – PN 20605-003 (Li-Ion) This battery uses 2200 mAh Li-ion cells with a charge specification of 10˚ C to 45˚ C (50˚ F to 113 ˚ F) and a discharge specification of -20˚ C to 60˚ C (-4˚ F to 140˚ F). This pack has an internal MOSFET cell disconnect. When the 7035 is installed in the cradle and is turned off, the battery will charge. When the 7035 is turned on, the terminal will draw power from the cradle; the battery pack will not discharge.
8.8.12.5 Agency Approvals USA Canada Europe
FCC Part 15 (EMI) ICES-003/CSA C108.8-M1983 (EMI) European “CE” mark: 72/73/EEC Low Voltage Directive 89/336/EEC EMC Directive
Teklogix 7035, 8255 & 8260 Terminals User Manual
219
Page 246
Chapter 8: Terminal Accessories GPS Unit
8.9 GPS Unit The 7035 terminal can support an optional GPS unit. This unit, a Garmin GPS 35HVS (TLX PN 30969), is a complete GPS receiver and antenna contained in a small, water resistant package. The Garmin GPS 35HVS can track up to 12 satellites at a time, while providing fast time-to-first-fix and one second navigation updates. The GPS unit was designed to be used in conjunction with the Psion Teklogix Powered Sled (Model 7937B), the Lithium Ion Battery Pack (PN 20605-003) and the Psion Teklogix Port Replicator (TLX PN 21655). The GPS unit plugs directly into the Port Replicator which supplies the GPS unit with power (from the Powered Sled supply) and connects the data lines to the 7035 terminal. The GPS unit should be mounted with a clear, unobstructed view of the GPS satellites. For optimal performance, the GPS unit should be mounted in an area that provides exposure to as large a swath of unobstructed sky as possible – a vehicle roof is an excellent choice. Important:
Keep in mind that some windows have thermal and/or UV filter or tint coatings that may shield satellite signals from the GPS receiver.
Psion Teklogix provides four types of Garmin mounting brackets to secure your GPS unit in position.
8.10 Active Transient Filter Power Supply The Active Transient Filter Power Supply (Model #8742) is designed to filter out large volumes of transients and in addition, it provides a power supply.
Figure 8.4 Active Transient Filter Power Supply 220 Teklogix 7035, 8255 & 8260 Terminals User Manual
Page 247
Chapter 8: Terminal Accessories Active Transient Filter Power Supply
Note: Water will not harm the Pre Regulator/Transient Suppressor if mounted in a way that prevents water from pooling in the upper case. The Pre-Reg should be mounted vertically with the mounting flange face down. The power module inside the unit is sealed. If mounted properly, the water drains out of the unit and does not harm the power supply inside the unit. The diagram below illustrates recommended connection options. Recommended Connections
Truck Battery Dirty power
Truck Battery Very Dirty power
13985 Cable
13985 Cable
Terminal
Filter Only 19893-500 Filter LC 10-100VDC In out
82xx Std, Low Temp, Freezer 7035 Powered Cradle
Power Supply Model #8742 Active Transient Filter 15-55VDC IN Nom Filters 168VDC 20msTrans. 18V-36 W out
82xx Std Temp, Low Temp 7035 Powered Cradles
Terminal
Figure 8.5 Recommended Connections Note: Teklogix provides another Transient Suppressor (PN 19893-500) that filters transients but does not provide a power supply.
Teklogix 7035, 8255 & 8260 Terminals User Manual
221
Page 248
Chapter 8: Terminal Accessories Accessories List
8.11 Accessories List Carrying Devices Accessory
Part No./ Model No.
7035 Handstrap Kit 7035 Wrist Strap 6 Ft. Shoulder Strap 7035 Hard Plastic Holster 7035 Soft Shell Holster 7035 Belt loop, leather (For use with protective case) Web Belt, nylon, 1.5" X 48", plastic buckle 7035 Velcro Belt 7035 Vinyl Carrying Case 7035 Splash Resistant Carrying Case Rubber Carrying Case (For 7035 with integrated scanner) Rubber Carrying Case (For 7035 without integrated scanner)
20610-002 30020 30585 30584-001 31711 20636 18108-004 18785-001 30586-001 30586-101 21425 31669
Mounts And Holding Devices 7035 Picker Cradle (vehicle/bench) non-powered 7035 Picker Cradle (vehicle) 11-16VDC 7035 Picker Cradle (vehicle) 10-55VDC Active Transient Filter Power Supply 7035 Port Replicator Kit 7035 Fixed Mount 7035 Pedestal Mount w/ locking joint Heavy-duty Pedestal Mount with locking joint 7035 Scanner Mounting Plate (accepts 7862 holder) 7035 Scanner Holder, vehicle-mount 7035 Long Scanner Holder, vehicle-mount Pistol Grip Assembly Kit (For integrated scanner versions only)
Table 8.4 Accessory Part Numbers/Model Numbers
222 Teklogix 7035, 8255 & 8260 Terminals User Manual
7937A 7937B 7937C 8742 21658 18448-001 18447-001 30082 18449-001 7862 7982A 20639