The text of a manual · part 27 of 41
7035/8255/8260 Terminals User Manual: Terminal Accessories 8, pages 232 to 240
Pages 232 to 240 of 348, from 7035/8255/8260 Terminals User Manual
The original document is the PDF (3.8 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Teklogix 7942, Teklogix 7978, Teklogix 7035, Psion 7942 and Psion 7978
Page 232
Chapter 8: Terminal Accessories Charger Fault Conditions
8.3.7 Charger Fault Conditions An internal charger fault is indicated if: •
The “Fault” LED remains illuminated after the terminal is removed.
•
All LEDs turn on and remain illuminated when the charger is powered up.
•
All LEDs turn on during normal operation.
Power should be cycled to the charger to correct these problems. If any of these symptoms occur persistently, the charger unit should be repaired by a qualified service technician.
8.3.8 Removing The Terminal From The In-Unit Charger To remove the terminal from the charger: • Apply steady downward pressure to the front of the charger with one hand while pulling up on the terminal. If necessary, you may need to use a gentle, side-to-side rocking motion to slide the terminal out of the charger well.
8.3.9 7942 Charger Specifications Charge Sites
Charge Time Compatibility Connection Charge Operation Lifetime: Reliability Power Supply
1 site for in-unit charging and a battery adaptor insert for this in-unit charger that allows a battery to be charged without the terminal. 3.5 to 4 hours Lithium-Ion (Li-Ion), Nickel-Metal Hydride (NiMH). Via contacts at base of battery pack (battery must be installed in terminal). Charging occurs automatically upon insertion without user intervention. Indicators display charge status. Minimum 5000 pack insertions, typical 10,000 insertions. Self-cleaning contacts. Autoranging (100-240 VAC ± 10%, 50/60 Hz)
206 Teklogix 7035, 8255 & 8260 Terminals User Manual
Page 233
Chapter 8: Terminal Accessories The 7967 Gang Charger
8.4 The 7967 Gang Charger The 7967 Gang Charger can charge up to six Lithium-Ion batteries at one time.
8.4.1 Connecting The Power Source The 7967 Gang Charger is powered using a universal AC input. It accepts voltages ranging from 100-230 volts AC, 50/60 Hz. The AC receptacle, an IEC 320 type connector, is located at the back of the charger. • Plug the female end of the AC line cord into the IEC connector at the back of the charger. • Plug the other end of the AC line cord into an appropriate power source. All front panel LEDs turn on for a few seconds during a self-test mode. The “Power On” LED then remains on, indicating a power connection. • Check to make sure that the fan is running.
8.4.2 Inserting And Charging The Battery The 7967 Gang Charger has a “Power On” LED and each charge pocket has three LEDs – Charge, Fault and Ready. Ensure that the green “Power On” LED at the front left side of the charger is “on”. The battery charge pockets are moulded, making it easy to snap the batteries into the pockets. •
With the four electrical contacts facing down and textured plastic battery surface facing the front of the charger, insert the battery into a charger pocket. It should click into place.
Charging will begin immediately.
Battery Charged And Ready When the “Charge” LED turns off and the green “Ready” LED turns on, the fast charge cycle is complete, and the battery is ready for use. Typically, a fast charge takes 3.5 to 4 hours. Note that for Lithium-Ion batteries, 70% of the charge occurs within the first hour.
8.4.3 Fault Conditions The red “Fault” LED turns on to indicate that the battery pack has been rejected or the charge process has failed.
Teklogix 7035, 8255 & 8260 Terminals User Manual
207
Page 234
Chapter 8: Terminal Accessories Fault LED Turns On During A Charge
8.4.3.1
Fault LED Turns On During A Charge
•
The battery temperature has changed such that it is outside of the acceptable range and the fast charge is halted. Remove the battery and permit it to warm or cool to room temperature before reinserting and restarting the charge.
•
The battery is defective – for example, the battery may have a weak cell, an open cell or a short.
•
The battery did not complete the charge cycle within the maximum timeout period. Clean the battery contacts and try inserting the battery for charging. Check the battery parameter performance using the utility provided in the 7035. Try another recharge cycle.
8.4.3.2
Fault LED Turns On At Insertion
•
The charger cannot read valid data from the battery. Clean the battery contacts and try charging the battery again.
•
In some cases, foreign matter may block the battery receptacle interface. Check the charger receptacle for debris and clear if required.
•
The hand-held terminal has set the pack to inhibit the charge. In this case, the battery is no longer useful and the battery should be returned to Teklogix Inc. for proper disposal. Return addresses are listed on page 201.
•
The battery is not compatible with this charger.
•
The battery temperature is outside of the acceptable range and the fast charge is inhibited. Remove the battery and permit it to warm or cool to room temperature before reinserting and restarting the charge.
8.4.4 7967 Charger Specifications Charge Sites Compatibility Connection Charge Operation Limitations
6 Lithium-Ion batteries only. Via contacts at top of battery pack. Charging occurs automatically upon insertion without user intervention. Indicators display charge status. Will not charge NiMH batteries. However, if a NiMH battery is inserted in this charger, neither the battery nor the charger will be damaged.
208 Teklogix 7035, 8255 & 8260 Terminals User Manual
Page 235
Chapter 8: Terminal Accessories 7978 Gang Charger
8.5 7978 Gang Charger The 7978 Gang charger can charge up to three Lithium-Ion batteries at one time.
8.5.1 Connecting The Power Source The 7978 Gang Charger is powered with an external universal AC power supply. It accepts voltages ranging from 100-240 volts AC, 50/60 Hz. The power supply has an IEC 20 type connector for the AC input and a DC output cord with attached plug. • • •
Plug the female end of the AC line cord into the IEC 320 type connector on the external power supply. Plug the power supply DC output cord with attached plug into the charger. Plug the other end of the AC line cord into an appropriate power source.
All front panel LEDs turn on momentarily. The ‘Power On’ LED then remains on indicating a power connection.
8.5.2 Inserting And Charging The Battery The 7978 Gang Charger has a “Power On” LED and each charge pocket has three LEDs – Charge, Fault and Ready. Ensure that the green “Power On” LED at the front left side of the charger is “on”. The battery charge pockets are moulded, making it easy to snap the batteries into the pockets. •
With the four electrical contacts facing down and textured plastic battery surface facing the front of the charger, insert the battery into a charger pocket. It should click into place.
Charging will begin immediately.
Battery Charged And Ready When the amber “Charge” LED turns off and the green “Ready” LED turns on, the fast charge cycle is complete, and the battery is ready for use. Typically, a fast charge takes 3.5 to 4 hours. Note that for Lithium-Ion batteries, 70% of the charge occurs within the first hour.
Teklogix 7035, 8255 & 8260 Terminals User Manual
209
Page 236
Chapter 8: Terminal Accessories Fault Conditions
8.5.3 Fault Conditions 8.5.3.1 • •
• •
8.5.3.2 •
8.5.3.3
Red “Fault” LED Turns On The battery is not compatible with the charger The 7035 has set the pack to inhibit the charge. In this case, the battery is no longer useful and should be returned to Psion Teklogix for proper disposal. The addresses are listed under “Lithium-Ion Battery Disposal Precautions” on page 11. The battery is defective. For example the battery may have a weak cell, an open cell or a short. The charger cannot read valid data from the battery. Clean the battery contacts and try charging the battery again.
Red “Fault” LED Blinks The battery temperature is higher than the acceptable range and the fast charge is inhibited. Remove the battery and permit it to cool to room temperature before reinserting and restarting the charge.
Yellow “Charge” LED Blinks – Low Temperature Standby
The amber “Charge” LED will blink when the battery temperature is below the acceptable range and the fast charge is inhibited. The battery will automatically commence charging when the battery temperature comes with in the acceptable range. Note: If the battery does not complete the charge cycle within the maximum timeout period, clean the battery contacts and try inserting the battery again. In some cases, foreign matter may prevent the battery contacts from properly connecting in the battery receptacle. Check the charger receptacle for debris and clean if required.
8.5.4 7978 Charge Specifications Charge Sites Compatibility Connection
210 Teklogix 7035, 8255 & 8260 Terminals User Manual
3 Lithium-Ion batteries only. Via contacts at top of battery pack.
Page 237
Chapter 8: Terminal Accessories Important Charger Safety Instructions Charge Operation
Limitations
Charging occurs automatically at insertion without user intervention. Indicators display charge status. Will not charge NiMH batteries. However, if a NiMH battery is inserted in this charger, neither the battery nor the charger will be damaged.
8.6 Important Charger Safety Instructions •
SAVE THESE INSTRUCTIONS – This manual contains important safety and operating instructions for battery charger Model 7967 and 7942. •
Before using the battery charger, read all instructions and cautionary markings on (1) battery charger, (2) battery, and (3) product using battery.
•
Use of an attachment not recommended or sold by the battery charger manufacturer may result in fire, electric shock, or personal injury.
•
To reduce risk of damage to the electric plug and cord when unplugging the charger, pull the plug rather than the cord.
•
Make sure the cord is positioned so that it is not stepped on, tripped over, or otherwise subjected to damage or stress.
•
Do not operate the charger with a damaged cord or plug. Replace immediately.
•
Do not operate the charger if it has received a sharp blow, been dropped, or otherwise damaged in any way; it should be inspected by qualified service personnel.
•
Do not disassemble the charger; it should be repaired by qualified service personnel. Incorrect reassembly may result in electric shock or fire.
•
To reduce risk of electric shock, unplug the charger from the outlet before attempting any maintenance or cleaning.
Teklogix 7035, 8255 & 8260 Terminals User Manual
211
Page 238
Chapter 8: Terminal Accessories Antenna Types •
An extension cord should not be used unless absolutely necessary. Use of an improper extension cord could result in fire or electric shock. If an extension cord must be used, make sure: • The plug pins on the extension cord are the same number, size, and shape as those on the charger. • The extension cord is properly wired and in good electrical condition and that the wire size is larger than 16 AWG.
•
Do not expose the charger to rain or snow.
•
Do not place batteries in the charger if they are cold from extended exposure to a freezer or outside temperatures below 10°C (50°F). Allow them to warm up to room temperature for at least two hours.
•
Do not use the charger if, after an overnight charge, any of the batteries feel warmer than the charger housing. The charger should be inspected by qualified service personnel.
•
Do not use the charger if any of the batteries or the charger get more than lukewarm. The equipment should be inspected by qualified personnel.
8.7 Antenna Types External whip antennas include 3 inch 2.4GHz dipole whips and 4 inch UHF whips.
Antenna Type
Connector Type
Internal
Plastic Cap
External
Reverse gender SMA
External
Standard SMA
Antenna Whip N/A 2.4 GHz Dipole PN 20667 UHF Whip PN 20668
Model Description N/A 7035-SS (Spread Spectrum) 7035-NB (Narrowband)
Table 8.2 7035 Antennas
8.8 The 7035 Picker Cradle Picker cradles provide physical support for terminals, allowing “hands-free” operation. Teklogix offers three types of picker cradles: • Model number 7937A – an unpowered picker cradle. •
Model number 7937B – a powered picker cradle with 11-16VDC input.
•
Model number 7937C – a powered picker cradle with 10-55 VDC input.
212 Teklogix 7035, 8255 & 8260 Terminals User Manual
Page 239
Chapter 8: Terminal Accessories Mounting Hardware
8.8.1 Mounting Hardware The 7035 Picker Cradle can be mounted on its own or with one of the following: • Heavy-duty pedestal mount (PN 30082) •
Pedestal mount with locking joint (PN 18447-001)
•
Mounting plate kit (PN 18448-001)
•
Scanner mounting plate (PN 18449-001)
•
Scanner holder (PN 92892)
8.8.2 Installation Note: Where applicable, the unit should be mounted inside the roll cage. Installation requirements vary depending on the type of application used – mobile (e.g., a fork lift truck) or fixed (e.g., a work table). For a typical installation: 1. Choose a suitable mounting location. 2. If necessary, connect the pass-through cable to an accessory. 3. Connect the power source.
8.8.3 Disassembling The Cradle Before Mounting Note: If the cradle is attached from behind to a plate or pedestal mount using the four threaded holes (#8-32) in the rear bracket, it does not need to be disassembled. Ensure that the screws used are the correct length. The rear bracket of the cradle also has four ‘through’ holes that allow the cradle to be attached directly to a surface. Prior to mounting, the plastic cradle must be removed. To disassemble the cradle: • Unscrew the two hex bolts (one per side), and pull away the plastic cradle.
Teklogix 7035, 8255 & 8260 Terminals User Manual
213
Page 240
Chapter 8: Terminal Accessories Disassembling The Cradle Before Mounting The diagram below includes the disassembly of the pedestal mount.
Figure 8.2 Disassembling The Cradle For Mounting
214 Teklogix 7035, 8255 & 8260 Terminals User Manual