Page 11
Connecting the Scanner The VS800 scanner connects to the host POS terminal via an interface cable. The cable connects to the scanner with a modular connector and to the host terminal with the connector required by the host (RS-232, OCIA, Keyboard Wedge, Wand or IBM POS). Figure 5 shows how to connect the scanner to the store host terminal. The type of DC power connector depends on your existing store host terminal. DC power to the scanner is supplied by one of two methods: 1.
From the host terminal (Power-Off-Terminal) through a single cable that carries both data and DC power.
2.
From an optional AC/DC power adapter that provides DC power, either through the side of the connector to the POS System, or through a branch in the Y-cable connection.
Never work on equipment, connect or disconnect signal cables during periods of lighting activity. Always power-down (switch off) all equipment prior to connecting cables.
Power-Off-Terminal (P.O.T.) 1.
Connect the interface cable to the scanner.
2.
Connect the other end of the interface cable to the host terminal.
AC/DC power supply (if required) 1.
Connect the interface cable to the scanner.
2.
Connect the DC barrel plug into the side of the connector at the POS end of the cable, or into the DC connector of the power branch of the Y-cable.
3.
Connect the interface cable to the host terminal.
4.
Plug the AC/DC power adapter into a functional AC outlet.
VS800™ Scanner User's Guide
9
Page 12
Power-Up Procedure The system power-up procedure may vary depending on the requirements of your Point-of-Sale (POS) system. Check with your system supervisor and/or refer to the terminal operator's manual for proper power-down and power-up procedures for your system. Figure 5. Connecting the Scanner to the Host Terminal a. Interface Connector b. Interface Cable c. Host Terminal Connector1 1
10 d. To Host Terminal e. DC Power Connector f. AC/DC Power Adapter
Your Host Terminal Connector may vary from the illustration.
VS800™ Scanner User's Guide
Page 13
Verifying Scanner Operation Power-up Power-up the system. The scanner will automatically run a PowerUp Selftest.
Passes Selftest The scanner should emit four successive tones indicating that it has passed the Power-Up Selftest routine. The LED indicator lamp flashes brightly once. The LED then transitions to a dim condition, (or Off if so programmed) indicating the scanner is ready for operation. Scan a few items to verify that data is properly communicated between the scanner and your POS terminal.
Fails Selftest If the scanner powers-up, but the LED lamp begins flashing and the speaker repeats a series of error tones, or the scanner does not read bar codes, or behaves erratically, go to the section titled Troubleshooting.
VS800™ Scanner User's Guide
11
Page 14
How To Scan The VS800 is ready to scan a bar code when the LED light is on dim1 (Operational Mode) or the LED is flashing slowly (Sleep Mode). The scanner's specially designed scan pattern minimizes the need for the operator to orient the item for scanning.
Scan Volume and Scan Depth As shown in Figure 6, the scan volume extends approximately eight inches (20 cm) in front of the scan window. The optimal scanning distance is at the center of the scan volume, or approximately four inches (10 cm) from the window. The scanner can read bar codes either in the sweep or presentation mode to accommodate different user styles. (See Figures 7 and 8). Figure 6. Scan Volume and Scan Depth b a c a. Scan Window b. Scan Volume
1.
12 c. Scan Depth (8 inches 20 cm)
Unless the LED is programmed to the Off condition by using special programming labels found in the Duet/VS800 Programming Guide (R44-1740).
VS800™ Scanner User's Guide
Page 15
Sweep Scanning To perform a sweep scan, move (sweep) the product, with the bar code facing the front window, laterally through the scan volume. Figure 7. Sweep Scanning
2HD
2HD
Presentation Scanning For optimum scanning performance, face the bar code towards the center of the front scanner window. Move the product with the bar code towards the scanner, as shown in Figure 8. Figure 8. Presentation Scanning
2HD
VS800™ Scanner User's Guide
13
Page 16
Customizing Your Scanner's Operation Customizing or programming a scanner provides maximum flexibility and allows a single scanner to serve many installation environments. Since the VS800 scanner supports a variety of interfaces, configurations and bar code symbologies, it may be necessary to customize your scanner to meet the specific requirements of your retail environment. Customizing the scanner is done by scanning special bar codes which change the way the scanner operates. If the scanner does not read bar codes and/or transmit data the way you need it to, contact your dealer or distributor for more programming options.
Changing The Volume There are three possible volume settings. Each time you scan the bar code below, the scanner’s volume changes to the next higher level. If the current volume is the highest selection, the volume changes to the lowest setting. If the scanner is powered off or reset, this setting returns to the factory default and will need to be set again to your desired setting. For permanent volume change, see the Duet/VS800 Scanner Programming Guide, (P/N: R44-1740).
Increment Volume
14
VS800™ Scanner User's Guide
Page 17
Other Programmable Features The table below shows some of the major features that may be changed using the Duet/VS800 Scanner Programming Guide.
Symbology Activation/Deactivation UPC/EAN/JAN: – UPC-A and UPC-E Add ons – EAN-8 and EAN-13 – UPC P2 and UPC P5 – Jan-8 and JAN -13 – Code 128 – UPC-A with EDGE™ stitching1 Industrial Codes: – Interleaved 2 of 5 – Code 128 – Code 39 (variable length) – Codabar – Code 39 (fixed length label stitching) – MSI/Plessey Other Features: – two label read – Autodiscriminate UPC EDGE™ with Add-ons and 5 Industrial codes.
Communication Interface Activation/Deactivation Single Interfaces: – Wand Emulation – RS-232 – Keyboard Wedge
– OCIA – IBM 46xx
Dual Interfaces: – RS-232 and IBM 46xx – RS-232 and OCIA – RS-232 and Keyboard-Wedge Triple Interfaces: – RS-232, IBM 46xx, and Keyboard-Wedge
1.
This optional feature is not available on all models. Contact your PSC dealer or distributor for more information.
VS800™ Scanner User's Guide
15
Page 18
Programmable Scanner Features User Indicators Parameters: – Speaker Volume Selection – Speaker Tone Pitch – Speaker Tone Length Sleep Mode: – Motor Timeout – Laser Timeout
Other programmable features include – Supplemental labels – Two label configuration
– Label ID prefixes – Coupon Processing
Contact PSC for more information on these programmable features.
16
VS800™ Scanner User's Guide
Page 19
Routine Maintenance The VS800 scanner's rugged design requires little maintenance. Routine maintenance consists of cleaning the scanner and Scan Window periodically.
Cleaning the Scan Window Regular cleaning of the window surface of the scanner reduces residue buildup and helps ensure the system’s highest performance.
WARNING
DO NOT USE ALCOHOL, PETROLEUM, ACETONE, ABRASIVE CLEANER OR ABRASIVE PADS. THEY WILL HARM OR SCRATCH THE SURFACE. ALCOHOL or ACETONE
ABRASIVES
Use these procedures for cleaning the scan window. NOTE
The scan window is a high quality, optical grade plastic. Use a soft lens cloth and non-abrasive cleaner to avoid scratching. 1.
Spray the cleaner on a soft, lint-free cloth and gently clean the window surface.
ss Gla ner a Cle
2.
Completely wipe the window dry with a soft, lint-free cloth.
VS800™ Scanner User's Guide
17
Page 20
Specifications Physical Specifications Scanner
AC/DC Power Adapter
Height = 5.90" (15.0 cm) Width = 3.50" (8.9 cm) Depth = 3.00" (7.6 cm) Weight = 12.0 oz. (311g)
Height = 2.80" (7.0 cm) Width = 2.10" (5.3 cm) Depth = 2.75" (7.0 cm) Weight = 10.0 oz. (290g)
Environmental Specifications Operating
Storage
Temperature
00 C to + 400 C 320 F to 1040 F
-400C to + 700 C -400 F to 1580 F
Humidity
5-95 % (non condensing)
5-95% (non-condensing)
Ambient Light
200 foot candles Maximum (2153 Lux )
Electrical Specifications Scanner Input Power Specifications Operational voltage DC Power Consumption Input Voltage Ripple
4.7 to 14 volts 3.00 watts max. (single interface) 500mV DC Maximum
External AC to DC Power Adapters Output:
12 VDC @ 600 mA
Power-Off-Terminal If the host terminal supplies the power, the host must provide power compatible with the Input Power Specification. For example, a 12V system must provide at least 250 mA (3 Watts). WARNING
Use only AC/DC Power Adapters approved by PSC for the VS800 scanner. Use of other power adapters may cause damage to the product which is not covered by the factory warranty. NOTE: Specifications subject to change without notice.
18
VS800™ Scanner User's Guide