Page 31
When to Indicate "Good Read" = CTS Goes Inactive, Then Active (RS-232 ONLY) Use this bar code to indicate "good read" after CTS switches from inactive to active.
6 R44-1740
400153
000027
27
Page 32
LED Lamp/Indication Features LED Features The scanner's LED lamp can be programmed to indicate the scanner is idle: • LED lamp is off when scanner is idle • LED lamp is dim when scanner is idle
28
Duet™ and VS800™ Scanner Programming Kit
Page 33
LED Lamp When Scanner is Idle = OFF Use this bar code to set the LED lamp to OFF when the scanner is idle.
6 R44-1740
400769
000015
29
Page 34
LED Lamp When Scanner is Idle = DIM Use this bar code to set the LED lamp to DIM when the scanner is idle.
6
30
400769
000022
Duet™ and VS800™ Scanner Programming Kit
Page 35
Timeouts Timeouts allow you to shut off the scanner's laser and/or motor if the scanner isn't used for a predetermined period of time. This feature is included to reduce power consumption and lengthen scanner life. NOTE Laser safety requires that the laser switch off before the motor. If you set the motor timeout shorter than the laser timeout, the laser will switch off when the motor times out.
R44-1740
31
Page 36
Setting Laser Timeout The laser timeout programming bar codes set the time for switching the laser off if the scanner isn't used. The selections are:
32
•
Laser timeout = 5 minutes
•
Laser timeout = 10 minutes
•
Laser timeout = 15 minutes
Duet™ and VS800™ Scanner Programming Kit
Page 37
Laser Timeout = 5 Minutes Use this bar code to set the laser timeout to 5 minutes.
6 400079 000200 R44-1740
33
Page 38
Laser Timeout = 10 Minutes Use this bar code to set the laser timeout to 10 minutes.
6 400079 000408 34
Duet™ and VS800™ Scanner Programming Kit
Page 39
Laser Timeout = 15 Minutes Use this bar code to set the laser timeout to 15 minutes.
6 400079 000606 R44-1740
35
Page 40
Setting Motor Timeout The Motor Timeout programming bar codes set the time for switching the motor off if the scanner isn't used. The motor will not timeout before the laser times out. The selections are:
36
•
Motor timeout = 5 minutes
•
Motor timeout = 15 minutes
•
Motor timeout = 30 minutes
•
Motor timeout = 60 minutes
Duet™ and VS800™ Scanner Programming Kit