For the PSC VS-800 and Datalogic VS-800

Page 341

4. 5.

Scan the bar codes in this section to modify the desired Codabar options. After programming all the chosen features, exit Programming Mode. (See Programming Your Scanner at the front of this manual.)

R44-1740

337

Page 342

Codabar: Check Character, Verify Use this bar code to enable calculation and verification of the optional Codabar check character. (The check character will not be sent to the host unless you also enable Codabar: Check Character, Send). This feature checks to see if data collected matches the bar code's internal check character.

6

338

400113

000012

Duet™ and VS800™ Scanner Programming Kit

Page 343

Codabar: Check Character, Don't Verify Use this bar code to disable verification of the Codabar check character. If you disable this feature, you should also scan the bar code that disables sending the Codabar check character.

6 R44-1740

400113

000005

339

Page 344

Codabar: Check Character, Send Use this bar code to instruct the scanner to send an optional Codabar check character to the host terminal. This feature will have no affect unless Codabar: Check Character, Verify is also enabled.

6

340

400140

000016

Duet™ and VS800™ Scanner Programming Kit

Page 345

Codabar: Check Character, Don't Send Use this bar code to disable transmission of the optional Codabar check character to the host terminal.

6 R44-1740

400140

000009

341

Page 346

Codabar Minimum Read Settings Minimum read settings define the minimum number of consecutive times a bar code must be decoded with the same result before it is accepted as a good read. A higher minimum read setting offers more assurance that a bar code has been correctly read, while a lower setting allows faster scanning performance. Selections for this option are: • Codabar: Minimum Read = 1 Use this setting when you do not experience misreads. • Codabar: Minimum Read = 2 Use this setting when you occasionally experience misreads. • Codabar: Minimum Read = 3 Use this setting when you regularly experience misreads. • Codabar: Minimum Read = 4 Use this setting when misreads are a common problem. If you must use settings of 3 or 4, examine your bar code printing/production methods.

342

Duet™ and VS800™ Scanner Programming Kit

Page 347

Codabar: Minimum Read = 1 Use this bar code to set the Codabar minimum read setting to 1.

6 400108 000010 R44-1740

343

Page 348

Codabar: Minimum Read = 2 Use this bar code to set the Codabar minimum read setting to 2.

6 400108 000027 344

Duet™ and VS800™ Scanner Programming Kit

Page 349

Codabar: Minimum Read = 3 Use this bar code to set the Codabar minimum read setting to 3.

6 R44-1740

400108

000034

345

Page 350

Codabar: Minimum Read = 4 Use this bar code to set the Codabar minimum read setting to 4.

6

346

400108

000041