Page 301
I 2 of 5: Minimum Allowable Length = 26 Use this bar code to set the I 2 of 5 minimum allowable length to 26 (including the check character).
6 R44-1740
400526
000265
297
Page 302
I 2 of 5: Minimum Allowable Length = 28 Use this bar code to set the I 2 of 5 minimum allowable length to 28 (including the check character).
6
298
400526
000289
Duet™ and VS800™ Scanner Programming Kit
Page 303
I 2 of 5: Minimum Allowable Length = 30 Use this bar code to set the I 2 of 5 minimum allowable length to 30 (including the check character).
6 R44-1740
400526
000302
299
Page 304
I 2 of 5: Minimum Allowable Length = 32 Use this bar code to set the I 2 of 5 minimum allowable length to 32 (including the check character).
6
300
400526
000326
Duet™ and VS800™ Scanner Programming Kit
Page 305
I 2 of 5 Fixed Length A fixed length defines for the scanner exactly how many characters should be present in the I 2 of 5 barcodes you plan to scan. This helps to avoid incomplete or erroneous bar code scans. You have the option of specifying either one or two fixed lengths for this symbology. NOTE If you choose not to set fixed length(s), it is recommended that you set a minimum allowable length for I 2 of 5 bar codes since this symbology is frequently subject to partial/misreads. To define I 2 of 5 Fixed Length(s): 1. Place the scanner in Programming Mode (see Programming Your Scanner at the front of this manual). 2. Scan the I 2 of 5: Fixed Length Control, Enable bar code.
R44-1740
301
Page 306
3.
4.
5.
6.
302
Determine the fixed length(s) you require. Example: You plan to scan I 2 of 5 bar codes that are six characters long or 14 characters long (including their check digit(s). Scan the appropriate first fixed length bar code. For our example, you would scan the I 2 of 5: First Fixed Length = 6 bar code. Scan the appropriate second fixed length bar code. For our example, you would scan the I 2 of 5: Second Fixed Length = 14 bar code. NOTE If no second fixed length is required, scan the No Second Fixed Length bar code. This instructs the scanner to recognize bar codes containing the first fixed length only. After programming all the chosen features, exit Programming Mode. (see Programming Your Scanner at the front of this manual.) Duet™ and VS800™ Scanner Programming Kit
Page 307
I 2 of 5: Fixed Length Control, Enable Scan this bar code to enable you to specify fixed lengths. This feature is described on the previous pages.
6 R44-1740
400555
000014
303
Page 308
I 2 of 5: Fixed Length Control, Disable Scan this bar code to disable fixed length specifications. When no fixed length is specified, the scanner will read any length I 2 of 5 bar code.
6
304
400555
000007
Duet™ and VS800™ Scanner Programming Kit
Page 309
I 2 of 5: First Fixed Length = 4 Scan the bar code below to set the first I 2 of 5 fixed length to 4 characters. The scanner will read and decode I 2 of 5 bar codes of ONLY this exact length (with the exception of a second fixed length you may set using the I 2 of 5: Second Fixed Length programming bar codes from this section).
6 400086 000040 R44-1740
305
Page 310
I 2 of 5: First Fixed Length = 6 Scan the bar code below to set the first I 2 of 5 fixed length to 6 characters. The scanner will read and decode I 2 of 5 bar codes of ONLY this exact length (with the exception of a second fixed length you may set using the I 2 of 5: Second Fixed Length programming bar codes from this section).
6 400086 000064 306
Duet™ and VS800™ Scanner Programming Kit