Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 31 of 39

Duet and VS800 Scanner Programming Kit, pages 301 to 310

Pages 301 to 310 of 386

The original document is the PDF (1.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the PSC VS-800 and Datalogic VS-800

Page 301

I 2 of 5: Minimum Allowable Length = 26 Use this bar code to set the I 2 of 5 minimum allowable length to 26 (including the check character).

6 R44-1740

400526

000265

297

Page 302

I 2 of 5: Minimum Allowable Length = 28 Use this bar code to set the I 2 of 5 minimum allowable length to 28 (including the check character).

6

298

400526

000289

Duet™ and VS800™ Scanner Programming Kit

Page 303

I 2 of 5: Minimum Allowable Length = 30 Use this bar code to set the I 2 of 5 minimum allowable length to 30 (including the check character).

6 R44-1740

400526

000302

299

Page 304

I 2 of 5: Minimum Allowable Length = 32 Use this bar code to set the I 2 of 5 minimum allowable length to 32 (including the check character).

6

300

400526

000326

Duet™ and VS800™ Scanner Programming Kit

Page 305

I 2 of 5 Fixed Length A fixed length defines for the scanner exactly how many characters should be present in the I 2 of 5 barcodes you plan to scan. This helps to avoid incomplete or erroneous bar code scans. You have the option of specifying either one or two fixed lengths for this symbology. NOTE If you choose not to set fixed length(s), it is recommended that you set a minimum allowable length for I 2 of 5 bar codes since this symbology is frequently subject to partial/misreads. To define I 2 of 5 Fixed Length(s): 1. Place the scanner in Programming Mode (see Programming Your Scanner at the front of this manual). 2. Scan the I 2 of 5: Fixed Length Control, Enable bar code.

R44-1740

301

Page 306

3.

4.

5.

6.

302

Determine the fixed length(s) you require. Example: You plan to scan I 2 of 5 bar codes that are six characters long or 14 characters long (including their check digit(s). Scan the appropriate first fixed length bar code. For our example, you would scan the I 2 of 5: First Fixed Length = 6 bar code. Scan the appropriate second fixed length bar code. For our example, you would scan the I 2 of 5: Second Fixed Length = 14 bar code. NOTE If no second fixed length is required, scan the No Second Fixed Length bar code. This instructs the scanner to recognize bar codes containing the first fixed length only. After programming all the chosen features, exit Programming Mode. (see Programming Your Scanner at the front of this manual.) Duet™ and VS800™ Scanner Programming Kit

Page 307

I 2 of 5: Fixed Length Control, Enable Scan this bar code to enable you to specify fixed lengths. This feature is described on the previous pages.

6 R44-1740

400555

000014

303

Page 308

I 2 of 5: Fixed Length Control, Disable Scan this bar code to disable fixed length specifications. When no fixed length is specified, the scanner will read any length I 2 of 5 bar code.

6

304

400555

000007

Duet™ and VS800™ Scanner Programming Kit

Page 309

I 2 of 5: First Fixed Length = 4 Scan the bar code below to set the first I 2 of 5 fixed length to 4 characters. The scanner will read and decode I 2 of 5 bar codes of ONLY this exact length (with the exception of a second fixed length you may set using the I 2 of 5: Second Fixed Length programming bar codes from this section).

6 400086 000040 R44-1740

305

Page 310

I 2 of 5: First Fixed Length = 6 Scan the bar code below to set the first I 2 of 5 fixed length to 6 characters. The scanner will read and decode I 2 of 5 bar codes of ONLY this exact length (with the exception of a second fixed length you may set using the I 2 of 5: Second Fixed Length programming bar codes from this section).

6 400086 000064 306

Duet™ and VS800™ Scanner Programming Kit