Page 231
Instore Minimum Read = 2 Use this bar code to set the Instore label minimum read to 2.
6 R44-1740
400133
000023
227
Page 232
Instore Minimum Read = 3 Use this bar code to set the Instore label minimum read to 3.
6
228
400133
000030
Duet™ and VS800™ Scanner Programming Kit
Page 233
Instore Minimum Read = 4 Use this bar code to set the Instore label minimum read to 4.
6 R44-1740
400133
000047
229
Page 234
Code 39 Options Options for the Code 39 symbology are contained on the following several pages. These options include: • Check Character Verification • Check Character Transmission • Minimum Read • Code 39 Stitching • Full ASCII Translation • Start/Stop Characters To use options available in this section: 1. Verify that Code 39 is a symbology supported by the scanner's current interface (see the Symbologies Supported table in the Interface Selection section of this manual). 2. Place the scanner in Programming Mode (see Programming Your Scanner at the front of this manual).
230
Duet™ and VS800™ Scanner Programming Kit
Page 235
3.
4. 5.
If Code 39 has not been enabled as an active symbology for the scanner being programmed, go to the Symbology Selection section of this manual and scan the Code 39, Enable programming bar code. Scan the bar codes in this section to modify the desired Code 39 options. After programming all the chosen features, exit Programming Mode (see Programming Your Scanner at the front of this manual).
R44-1740
231
Page 236
Code 39: Check Character, Verify Use this bar code to enable calculation and verification of the optional Code 39 check character. (The check character will not be sent to the host unless you also enable Code 39: Check Character, Send). This feature checks to see if data collected matches the bar code's internal check character.
6 400085 000010 232
Duet™ and VS800™ Scanner Programming Kit
Page 237
Code 39: Check Character, Don't Verify Using this bar code disables verification of the Code 39 check character. If you disable this feature, you should also scan the bar code that disables sending the Code 39 check character.
6 400085 000003 R44-1740
233
Page 238
Code 39: Check Character, Send Use this bar code to instruct the scanner to send an optional Code 39 check character to the host terminal. This feature will have no affect unless Code 39: Check Character, Verify is also enabled.
6 400138 000011 234
Duet™ and VS800™ Scanner Programming Kit
Page 239
Code 39: Check Character, Don't Send Use this bar code to disable transmission of an optional Code 39 check character to the host terminal.
6 400138 000004 R44-1740
235
Page 240
Code 39 Minimum Read Settings Minimum read settings define the minimum number of consecutive times a bar code must be decoded with the same result before it is accepted as a good read. A higher minimum read setting offers more assurance that a bar code has been correctly read, while a lower setting allows faster scanning performance. Selections for this option are: • Code 39: Minimum Read = 1 Use this setting when you do not experience misreads. • Code 39: Minimum Read = 2 Use this setting when you occasionally experience misreads. • Code 39: Minimum Read = 3 Use this setting when you regularly experience misreads. • Code 39: Minimum Read = 4 Use this setting when misreads are a common problem. If you must use settings of 3 or 4, examine your bar code printing/production methods.
236