Page 91
RS-232: Stop Bits = 2 Use this bar code to set the number of stop bits to two.
6 400034 000016 R44-1740
87
Page 92
RS-232: CTS Flow Control, Enable When Clear To Send (CTS) flow control is enabled, the CTS signal controls the transmission of data to the host. NOTE If this feature is enabled, Xon/Off (software flow control) should be disabled (scan the bar code: Xon/Xoff - Disable). The result of enabling both flow controls is unpredictable. Scan the bar code below to enable CTS flow control.
6
88
400527
000011
Duet™ and VS800™ Scanner Programming Kit
Page 93
RS-232: CTS Scan Control, Enable When this option is enabled, the Clear To Send (CTS) line must be active for the scanner to read and transmit data. While the CTS line is inactive, the scanner will remain in a host disabled state. Following a successful transmission, the CTS signal must transition to inactive and then to active to enable scanning for the next bar code. Scan the bar code below to enable CTS scan control.
6 R44-1740
400527
000028
89
Page 94
RS-232: Hardware Control, Disable When hardware control (CTS flow control and/or CTS scan control) is disabled, the scanner will transmit data to the host regardless of any activity on the CTS line. Scan the bar code below to disable hardware control.
6
90
400527
000004
Duet™ and VS800™ Scanner Programming Kit
Page 95
RS-232: Software Control (Xon/Xoff), Enable Use this bar code to enable Xon/ Xoff for data flow control.
NOTE If this feature is enabled, CTS Flow Control should be disabled (scan the bar code: Hardware Control - Disable). The result of enabling both flow controls is unpredictable. This configuration item will be ignored if Host Echo is enabled.
6 400033 000017 R44-1740
91
Page 96
RS-232: Software Control (Xon/Xoff), Disable Use this bar code to disable Xon/ Xoff (no data flow control).
6 400033 000000 92
Duet™ and VS800™ Scanner Programming Kit
Page 97
RS-232 Host Echo Feature The scanner can be configured to echo (to the host) all characters received. The scanner shall echo character data as well as an RS232 break. The priority of transmission is: 1. Break data 2. Label data 3. Echo data NOTE If the transmission is inhibited for any reason, the character will be buffered until transmission is enabled. Additional characters received during this time will overwrite the buffered character. When transmission with parity has been configured, the scanner will calculate and apply the proper parity to the data being transmitted. The parity of the received data is ignored.
R44-1740
93
Page 98
RS-232: Host Echo, Enable
Scan this bar code to enable Host Echo.
6
94
400205
000012
Duet™ and VS800™ Scanner Programming Kit
Page 99
RS-232: Host Echo, Disable
Scan this bar code to disable Host Echo.
6 R44-1740
400205
000005
95
Page 100
RS-232: Intercharacter Delay = 0 This feature sets the delay between the end of one character and the beginning of the next, in 10 millisecond increments. This delay is enforced between all transmitted elements including host echo characters. Scan this bar code to set intercharacter delay to specify no delay.
6
96
400156
000000
Duet™ and VS800™ Scanner Programming Kit