For the PSC VS-800 and Datalogic VS-800

Page 91

RS-232: Stop Bits = 2 Use this bar code to set the number of stop bits to two.

6 400034 000016 R44-1740

87

Page 92

RS-232: CTS Flow Control, Enable When Clear To Send (CTS) flow control is enabled, the CTS signal controls the transmission of data to the host. NOTE If this feature is enabled, Xon/Off (software flow control) should be disabled (scan the bar code: Xon/Xoff - Disable). The result of enabling both flow controls is unpredictable. Scan the bar code below to enable CTS flow control.

6

88

400527

000011

Duet™ and VS800™ Scanner Programming Kit

Page 93

RS-232: CTS Scan Control, Enable When this option is enabled, the Clear To Send (CTS) line must be active for the scanner to read and transmit data. While the CTS line is inactive, the scanner will remain in a host disabled state. Following a successful transmission, the CTS signal must transition to inactive and then to active to enable scanning for the next bar code. Scan the bar code below to enable CTS scan control.

6 R44-1740

400527

000028

89

Page 94

RS-232: Hardware Control, Disable When hardware control (CTS flow control and/or CTS scan control) is disabled, the scanner will transmit data to the host regardless of any activity on the CTS line. Scan the bar code below to disable hardware control.

6

90

400527

000004

Duet™ and VS800™ Scanner Programming Kit

Page 95

RS-232: Software Control (Xon/Xoff), Enable Use this bar code to enable Xon/ Xoff for data flow control.

NOTE If this feature is enabled, CTS Flow Control should be disabled (scan the bar code: Hardware Control - Disable). The result of enabling both flow controls is unpredictable. This configuration item will be ignored if Host Echo is enabled.

6 400033 000017 R44-1740

91

Page 96

RS-232: Software Control (Xon/Xoff), Disable Use this bar code to disable Xon/ Xoff (no data flow control).

6 400033 000000 92

Duet™ and VS800™ Scanner Programming Kit

Page 97

RS-232 Host Echo Feature The scanner can be configured to echo (to the host) all characters received. The scanner shall echo character data as well as an RS232 break. The priority of transmission is: 1. Break data 2. Label data 3. Echo data NOTE If the transmission is inhibited for any reason, the character will be buffered until transmission is enabled. Additional characters received during this time will overwrite the buffered character. When transmission with parity has been configured, the scanner will calculate and apply the proper parity to the data being transmitted. The parity of the received data is ignored.

R44-1740

93

Page 98

RS-232: Host Echo, Enable

Scan this bar code to enable Host Echo.

6

94

400205

000012

Duet™ and VS800™ Scanner Programming Kit

Page 99

RS-232: Host Echo, Disable

Scan this bar code to disable Host Echo.

6 R44-1740

400205

000005

95

Page 100

RS-232: Intercharacter Delay = 0 This feature sets the delay between the end of one character and the beginning of the next, in 10 millisecond increments. This delay is enforced between all transmitted elements including host echo characters. Scan this bar code to set intercharacter delay to specify no delay.

6

96

400156

000000

Duet™ and VS800™ Scanner Programming Kit