The text of a manual · part 1 of 39
Duet and VS800 Scanner Programming Kit, pages 1 to 10
Pages 1 to 10 of 386
The original document is the PDF (1.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the PSC VS-800 and Datalogic VS-800
Page 1
PSC DUET / VS800" Scanner e 8)
®
> a. 4 DUET Scanner =
VS800 Scanner
Programming Kit
Page 2
PSC Scanning, Inc. 959 Terry Street Eugene, Oregon 97402 Telephone: (541) 683-5700 Toll Free: (800) 547-2507 Telefax: (541) 686-1702 PSC and the PSC logo are registered trademarks of PSC INC. Duet and VS800 are trademarks of PSC INC. This manual and its contents are copyrighted, with all rights reserved. Under copyright law, this manual may not be copied in whole or in part without the prior written consent of PSC. The same proprietary and copyright notices must appear on any permitted copies as appear on the original. This exception does not permit copies to be made for others, whether or not sold. Under the law, copying includes translating into another language or format. The information and specifications contained in this manual are subject to change without notice. PSC shall not be held liable for damages resulting from the use or misuse of the information contained herein.
Page 3
Contents Programming Your Scanner ......................................................... 2 Programmable Features .............................................................. 5 Return to Factory Settings ........................................................... 6 Additional Features ...................................................................... 7 Programmable Rear Scan Line .................................................... 9 Programmable Speaker Features .............................................. 11 LED Lamp/Indication Features .................................................. 28 Timeouts .................................................................................... 31 Setting Laser Timeout ....................................................... 32 Setting Motor Timeout ....................................................... 36 Setting Double Read Timeout ........................................... 41 Interface Selection ..................................................................... 47 Changing Interfaces .......................................................... 48 RS-232 Interface Configuration ................................................ 71 RS-232 Restrictions .......................................................... 72 RS-232 Host Echo Feature ............................................... 93 RS-232 ACK/NAK Options .............................................. 109 OCIA Interface Configuration ................................................. 114 Wand Interface Configuration ................................................ 121 Keyboard Wedge Interface Configuration .............................. 134 IBM 46xx Configuration ......................................................... 157
R44-1740 i
Page 4
Label Transmit Format Configuration Items ..................................................... 164 Setting Label I.D. ............................................................. 165 Symbology Selection ............................................................... 172 UPC/EAN Options ................................................................. 186 UPC/EAN Expansion ...................................................... 188 UPC/EAN Check Digit Transmission ............................... 196 UPC/EAN/Instore Minimum Read Settings .................................................................. 209 Code 39 Options ...................................................................... 230 Code 39 Stitching Options .............................................. 241 Code 128 Options .................................................................. 263 Code 128 Minimum Read Settings ................................. 265 Interleaved 2 of 5 Options ........................................................ 274 I 2 of 5 Minimum Read Settings .............................................. 280 I 2 of 5 Length Control ..................................................... 285 I 2 of 5 Fixed Length ....................................................... 301 Codabar Options .................................................................... 336 Codabar Minimum Read Settings ................................... 342 MSI/Plessey Options ............................................................... 355 MSI/Plessey Minimum Read Settings ............................. 363 Index ........................................................................................ 368 ii
Duet™ and VS800™ Scanner Programming Kit
Page 5
Programming with Bar Codes This programming kit contains the procedures and bar code programming labels necessary to set the scanner's programmable features.
R44-1740
1
Page 6
Programming Your Scanner To program your scanner: 1. Power up the scanner to be programmed by one of the following methods: • Connect the scanner's interface cable at the scanner. Plug the AC/DC Adapter into an electrical outlet of the appropriate voltage and connect its other end at either the port located on the scanner's interface cable connector (furthest from the scanner) or its "pigtail" connection (see Figure 1*). • If the scanner is configured to receive power off the terminal (POT), connect the scanner via its interface cable to a working host terminal. Wait for the scanner to complete the Selftest routine and emit four tones. The green lamp will light dimly, indicating that the scanner is in normal Operating Mode.
2
Duet™ and VS800™ Scanner Programming Kit
Page 7
Figure 1. Power Up Scanner AC/DC Power Supply 1. Connnect the I/F cable to the scanner. 2. Connect the DC power cord into the side of the connector.* 3. Connect the I/F cable into the host terminal. 4. Connect the AC/DC power supply into an AC outlet.
Interface Connector 1
Host Terminal * Connector
Duet™ Scanner I/F Cable
2
Barrel Type Connector 3
DC Power Supply Connector
4
AC Power
AC/DC Power Adapter
Power-Off Terminal 1. Connect the I/F cable to the scanner. 2. Connect the I/F cable to the host terminal
To Host Terminal
Interface Connector
Duet™ Scanner Interface Connector
1
Host Terminal Connector *
I/F Cable
2
To Host Terminal
1
Host Terminal Connector * 2
Duet™ Scanner
I/F Cable 3
AC Power
AC/DC Power Adapter
R44-1740
4
DC Power Connector
AC/DC power supply into DC power connector
1. Connnect the I/F cable to the scanner. 2. Connect the I/F cable to the terminal. 3. Connect the DC power plug into the DC power connector. 4. Connect the AC/DC power supply into an AC outlet. * Your host terminal connection may be different.
3
Page 8
2.
3.
4.
4
Put the scanner into Programming Mode by scanning the Programming Switch bar code located on the next page and on the inside back cover. The green LED flashes continuously indicating that the scanner is in Programming Mode. Scan the programming bar code(s) for the feature you want to change. The scanner will emit three beeps to indicate that the bar code has been read and the setting has been stored in the scanner’s memory. Scan the remaining programming bar codes as required. If a bar code scanned is not a valid programming bar code, the scanner will emit a “chirping” (rapid beeping) rejection tone. After all the desired programming bar codes have been successfully scanned, exit Programming Mode by scanning the Programming Switch bar code once again. The scanner will reset and emit four beeps during the power-up sequence. Duet™ and VS800™ Scanner Programming Kit
Page 9
The green lamp will light dimly, indicating that the scanner is ready for normal operation.
Switch
Label
Programmable Features The remainder of this programming kit contains programming bar codes for all programmable features for the Duet™ and VS800 scanners. Refer to the detailed features listing shown in the index at the back of this manual to find the individual features that you wish to change.
R44-1740
5
Page 10
Return to Factory Settings Use this bar code to reset all options back to the original factory default settings for the current interface. For example, if your scanner's current interface is RS-232, all settings will return to the scanner's original factory settings for the RS-232 interface. NOTE Any settings you have selected in a previous programming session will be lost.
6 500000 000009 6
Duet™ and VS800™ Scanner Programming Kit