CODE 39 (CONTINUED) Use these labels to change the Code 39 programmable features.
SET
-------------------------------------
SYMBOLOGY SELECTION
CHECK D IGIT
DON 'T C OMPUTE --------------COMPUTE ---------------------DON 'T TRANSMIT --------------
START /STOP
DON 'T D ECODE ----------------
CODE 39 F ULL ASCII
DON 'T TRANSMIT ---------------
SINGLE D IGIT L ABELS
TRANSMIT ---------------------
END R44-1020
TRANSMIT ---------------------
DECODE ----------------------ENABLE -----------------------DISABLE -----------------------------------------------------------
65
Page 72
INTERLEAVED 2 OF 5 The Interleaved 2 of 5 symbology has the following programmable features: Check Digit, calculate the Check Digit to verify that the Check Digit contained in the barcode label is correct. If you enable this feature, your barcodes must contain a Check Digit.
SYMBOLOGY SELECTION
You may also choose to transmit or not transmit the Check Digit independent of whether the Check Digit is calculated by the scanner. If you choose to Transmit Check Digit, but not calculate, the scanner sends the Check Digit encoded in the barcode without verifying its accuracy. If you choose Don't Transmit Check Digit, the scanner will remove the Check Digit's contents before sending the barcode data to the host. Label Format, provides the selection between fixed or variable length labels. If your application has labels with specific fixed lengths, we recommend selecting fixed lengths to improve read rate and avoid short reads. You can select any valid number of digits for reading specific length labels only. Read the following details for specific Interleaved 2 of 5 limits.
INTERLEAVED 2 OF 5 LABEL LENGTHS If you select variable length, the scanner will recognize labels with an even number of digits between 04 and 50 digits. If you select fixed length, there are three labels for programming your scanner to read either one or two fixed lengths. The labels are: Set First Fixed Length, use this label to instruct the scanner that the next two programming labels you scan will define the first fixed label length. This setting can be any even number of digits between 04 and 50 digits. Set Second Fixed Length, use this label to instruct the scanner that the next two programming labels you scan will define the second fixed label length. Again, this setting can be any even number of digits between 04 and 50 digits. No Second Fixed Length, scan this label after setting the first fixed length to instruct the scanner to recognize only the label length chosen as the first fixed length.
66
SP400 Programming Guide
Page 73
INTERLEAVED 2 OF 5 These programming labels determine whether you compute and send the check digit contents. If you want to set the scanner to read only fixed length labels, follow the procedures on pages 68 and 69.
-------------------------------------
SYMBOLOGY SELECTION
SET
CHECK D IGIT
D ON' T COMPUTE ---------------COMPUTE ---------------------D ON' T TRANSMIT ---------------
VARIABLE LENGTH L ABELS
T RANSMIT ---------------------
END
R44-1020
E NABLE -----------------------D ISABLE -----------------------------------------------------------
67
Page 74
INTERLEAVED 2 OF 5 FIXED LENGTH All interfaces that are shipped with the standard factory configuration are set to read variable length labels. If you switch from variable to fixed length labels, the default fixed label lengths are 14 digits and 8 digits. Follow the steps below to change these defaults. All fixed length settings for Interleaved 2 of 5 must be an even number. SET FIXED 1. Identify the fixed length settings you want to make. 2.
Scan the SET label.
3.
Scan the Enable First Fixed barcode.
4.
Set the first fixed label length by scanning the correct digits from the next page. If you need to set a second fixed length, continue with step five. If you do not need to set a second fixed length scan the No 2nd Fixed Length on this page and skip to step seven.
SET
------------------------------------SET 1ST F IXED LENGTH --------
I NTERLEAVED 2 OF 5
SYMBOLOGY SELECTION
SETTING LENGTHS If you are setting a length less than ten, you must scan a zero first and then the length digit ( 04, 06, 08).
SET 2ND FIXED L ENGTH -------N O 2ND FIXED L ENGTH --------
68
SP400 Programming Guide
Page 75
5.
Scan the Set Second Fixed label.
6.
Set the second fixed label length by scanning the correct digits from this page.
7.
Scan the END label to complete the procedure.
0 -----------------------------
SYMBOLOGY SELECTION
1 ----------------------------2 ----------------------------3 ----------------------------4 ----------------------------5 ----------------------------6 ----------------------------8 ----------------------------END
R44-1020
-------------------------------------
69
Page 76
STANDARD 2 OF 5 The Standard 2 of 5 symbology has the following programmable features: Check Digit, calculate the Check Digit to verify that the Check Digit contained in the barcode label is correct. If you enable this feature, your barcodes must contain a Check Digit.
SYMBOLOGY SELECTION
You may also choose to transmit or not transmit the Check Digit independent of whether the Check Digit is calculated by the scanner. If you choose to Transmit Check Digit, but not calculate, the scanner sends the Check Digit encoded in the barcode without verifying its accuracy. If you choose Don't Transmit Check Digit, the scanner will remove the Check Digit's contents before sending the barcode data to the host. Label Format, provides the selection between fixed or variable length labels. If your application has labels with specific fixed lengths, we recommend selecting fixed lengths to improve read rate. You can select any valid number of digits for reading specific length labels only. Read the following details for specific Standard 2 of 5 limits.
STANDARD 2 OF 5 LABEL LENGTHS If you select variable length, the scanner will recognize labels with between 4 and 38 digits. If you select fixed length, there are three labels for programming your scanner to read either one or two fixed lengths. The labels are: Set First Fixed Length, use this label to instruct the scanner that the next two programming labels you scan will define the first fixed label length. This setting can be any number of digits between 04 and 38 digits. Set Second Fixed Length, use this label to instruct the scanner that the next two programming labels you scan will define the second fixed label length. Again, this setting can be any number of digits between 04 and 38 digits. No Second Fixed Length, scan this label after setting the first fixed length to instruct the scanner to recognize only the label length chosen as the first label length.
70
SP400 Programming Guide
Page 77
STANDARD 2 OF 5 These programming labels determine whether you compute and send the check digit contents. If you want to set the scanner to read only fixed length labels, follow the procedures on pages 72 and 73.
-------------------------------------
SYMBOLOGY SELECTION
SET
CHECK D IGIT
DON ' T COMPUTE ---------------COMPUTE ---------------------DON ' T TRANSMIT ---------------
VARIABLE LENGTH L ABELS
T RANSMIT ---------------------
END
R44-1020
E NABLE -----------------------DISABLE -----------------------------------------------------------
71
Page 78
STANDARD 2 OF 5 FIXED LENGTH All interfaces shipped with the standard factory settings are set to read variable length labels Standard 2 of 5. If you switch from variable to fixed length labels, the default fixed label lengths are 14 digits and 8 digits. Follow the steps below to change these defaults. SET FIXED 1. Identify the fixed length settings you want to make. 2.
Scan the SET label.
3.
Scan the Enable First Fixed barcode.
4.
Set the first fixed label length by scanning the correct digits from the next page. If you need to set a second fixed length, continue with step five. If you do not need to set a second fixed length scan the No 2nd Fixed Length label below and skip to step seven.
SET
------------------------------------SET 1ST F IXED LENGTH --------
STANDARD 2 OF 5
SYMBOLOGY SELECTION
SETTING LENGTHS If you are setting a length less than ten, you must scan a zero first and then the length digit (04, 05, ..., 09).
SET 2ND FIXED L ENGTH -------N O 2ND FIXED L ENGTH --------
72
SP400 Programming Guide
Page 79
5.
Scan the Set Second Fixed label.
6.
Set the second fixed label length by scanning the correct digits from this page.
7.
Scan the END label to complete the procedure.
SYMBOLOGY SELECTION
0 ----------------------------1 ----------------------------2 ----------------------------3 ----------------------------4 ----------------------------5 ----------------------------6 ----------------------------7 ----------------------------8 ----------------------------9 ----------------------------END
R44-1020
-------------------------------------
73
Page 80
CODABAR OPTIONS The Codabar symbology has the following programmable features: Check Digit, calculate the Check Digit to verify the labels contents have been read correctly. If you enable this feature, your barcodes must include a Check Digit. You may also choose to transmit or not transmit the Check Digit. Start/Stop Characters, you can choose either Send or Don't Send depending on your host's interface requirement.
SYMBOLOGY SELECTION
Start/Stop Format, if you need to send the Start/Stop characters, there are four standard format options that you can select from; ABCD/TN*E, ABCD/ABCD, abcd/tn*e, or abcd/abcd. This setting must match your system requirements. If you select one of these options, it determines how the ASCII characters A, B, C, D that are used for Start/Stop characters, will be translated before being sent to the host. Start/Stop Match, the requirement that the Start and Stop characters must match (be identical) can be enabled or disabled. Label Format, provides the selection between fixed or variable length labels. If your application has labels with specific fixed length, we recommend selecting fixed lengths to improve read rate. If you select variable length, the scanner will recognize labels with between 2 and 47 digits (not including the optional check digit). Set First Fixed Length, if you select fixed length, use this feature to set a first fixed label length to a setting between 2 and 47 digits. Set Second Fixed Length, if you select fixed length, use this feature to set a second fixed label length to a setting between 2 and 47 digits. No Second Fixed Length, scan this label after setting the first fixed length to instruct the scanner to recognize only the label length chosen as the first label length. Gap Check, allows the scanner to combine two label halves printed in close proximity to each other that may have been printed at different times and perhaps different locations.
74
SP400 Programming Guide