The text of a manual · part 8 of 38
QuickScan QS6500/QS6500BT Product Reference Guide: Interface Related Features, pages 57 to 66
Pages 57 to 66 of 336, from QuickScan QS6500/QS6500BT Product Reference Guide
The original document is the PDF (4.3 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the PSC QS6500BT and Datalogic QS6500BT Base
Page 57
Interface Features
RS-232 Interface Features, cont. ACK NAK Timeout Value START MODE
BARCODE This item specifies the time the imager will wait for an ACK character from the host following a label transmission. 0 = Infinite timeout 1 - 75 = Timeout in 200-millisecond increments To configure this feature, scan the “START” bar code above to place the unit in Programming Mode, then the “Set ACK NAK Timeout Value,” followed by the digits from the Alphanumeric table in Appendix B, Alpha-Numeric Pad representing your desired value. Accept your selection by scanning the “SET” bar code below and finally, exit programming mode by scanning the “END” barcode below DEFAULT SETTING FOR THIS FEATURE: 01
Set ACK NAK Timeout Value SET
END
Product Reference Guide
4-21
Page 58
Interface Related Features
RS-232 Interface Features, cont. ACK NAK Retry Count START MODE
BARCODE This feature sets the number of times for the imager to retry a label transmission under a retry condition. 0 = No retry 1 - 254 = Retry for the specified number of times 255 = Retry forever To configure this feature, scan the “START” bar code above to place the unit in Programming Mode, then the “Set ACK NAK Retry Count,” followed by the digits from the Alphanumeric table in Appendix B, Alpha-Numeric Pad representing your desired retry count. Accept your selection by scanning the “SET” bar code below and finally, exit programming mode by scanning the “END” barcode below DEFAULT SETTING FOR THIS FEATURE: 03
Set ACK Nak Retry Count SET
END
4-22
QuickScan® QS6500/QS6500 BT
Page 59
Interface Features
RS-232 Interface Features, cont. ACK NAK Error Handling This item specifies the method the imager will use to handle errors detected while waiting to receive the ACK character from the host. Errors include unrecognized host commands and communication errors such as parity or framing errors. Choices are: 00 = Ignore errors detected (recommended setting) 01 = Process error as valid ACK character (risk of lost label data) 02 = Process error as valid NAK character (risk of duplicate label data) START STATE
BARCODE
Ignore Errors Detected Process error as valid ACK character Process error as valid NAK character END
Product Reference Guide
4-23
Page 60
Interface Related Features
RS-232 Interface Features, cont. Transmission Failure Indication Enables/disables bad-label indication upon transmission failure. START STATE Disable Transmission Error Indication Enable Transmission Error Indication
BARCODE
END
4-24
QuickScan® QS6500/QS6500 BT
Page 61
Interface Features
IBM-USB Interface Features IBM-USB Device usage The IBM-USB protocol allows for the imager to be identified as one of two different types of bar code scanners. Depending on what other scanners you may already have connected to a IBM-USB POS, you may need to change this setting to enable all devices to communicate. Options are: •
Table Top Scanner
•
Handheld Scanner START
STATE Configure as Table Top Scanner Configure as Handheld Scanner
BARCODE
END
Product Reference Guide
4-25
Page 62
Interface Related Features
IBM IBM Transmit Labels in Code 39 Format This feature enables/disables imager's ability to set a symbology identifier for a specified label to Code 39 before transmitting that label data to an IBM host. This applies to: Code 128, Codabar, and Code 93 for IBM USB; Code 128, Codabar, and Code 93 for IBM Port 5B; and Codabar and Code 93 for IBM Port 9B. START STATE Disable Convert to Code 39
BARCODE
Enable Convert to Code 39 END
4-26
QuickScan® QS6500/QS6500 BT
Page 63
Interface Features
Keyboard Wedge/USB Keyboard As a keyboard interface, the imager supports most popular PCs and IBM terminals. The installation of the wedge is a fairly simple process that doesn’t require any changes of software or hardware.
NOTE
All of the options in this section apply to the Keyboard Wedge, however, only Keyboard Layout, Caps Lock State and Control Characters apply to USB Keyboard.
Keyboard Layout
The Keyboard Layout option supports many countries. For details about Keyboard Layout, please refer to your operating system manual. START STATE
BARCODE
USA
Belgium Britain Denmark France Germany Italy Norway
Product Reference Guide
4-27
Page 64
Interface Related Features START STATE
BARCODE
Portugal Spain Sweden
Switzerland
Japan 106 Key
Hungary
Czech
Slovakia
Romania
END
4-28
QuickScan® QS6500/QS6500 BT
Page 65
Interface Features
Keyboard Wedge/USB Keyboard, cont. Caps Lock State
Specifies which format the imager sends character data. START STATE
BARCODE
Disable Caps Lock Caps Lock “ON”
Shift Lock “ON”
END
Product Reference Guide
4-29
Page 66
Interface Related Features
Keyboard Wedge/USB Keyboard, cont. Power-On Simulation This feature does not apply to the USB Keyboard interface. NOTE
All PCs check the keyboard status during the power-on Selftest. It is recommended that you enable this function if you are working without a keyboard installation. It simulates keyboard timing and passes the keyboard status to the PC during power-on. Control Characters
Specifies how the imager transmits ASCII control characters to the host. Choices are: •
Disable Control Characters
•
Enable transmission of control characters to host
•
Send characters between 00H and 1FH according to a special function-key mapping table. (This is used to send keys that are not in the normal ASCII set; a unique set is provided for each available scancode set. Reference Appendix D, Keyboard Function Key Mappings.)
4-30
QuickScan® QS6500/QS6500 BT