The text of a manual · part 7 of 38
QuickScan QS6500/QS6500BT Product Reference Guide: Interface Related Features, pages 47 to 56
Pages 47 to 56 of 336, from QuickScan QS6500/QS6500BT Product Reference Guide
The original document is the PDF (4.3 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the PSC QS6500BT and Datalogic QS6500BT Base
Page 47
Interface Features
RS-232 Interface Features, cont. Hardware Flow Control Disable Hardware Control, The imager transmits to the host regardless of any activity on the CTS line. Enable CTS Flow Control, The CTS signal controls transmission of data to the host. Enable CTS Scan Control, The CTS line must be active for the imager to read and transmit data. While the CTS line is inactive, the imager remains in a host-disabled state; following a successful label transmission, the CTS signal must transition to inactive and then to active to enable scanning for the next label.
Intercharacter Delay This delay is inserted after each data character transmitted. If the transmission speed is too high, the system may not be able to receive all characters. You may need to adjust the delay to make the system work properly.
Software Flow Control Disables/Enables software control using XON/XOFF characters.
Product Reference Guide
4-11
Page 48
Interface Related Features
RS-232 Interface Features, cont. START STATE Disable Hardware Control
BARCODE
Enable CTS Flow Control Enable CTS Scan Control Inter-Char Delay = No Delay Interchar Delay = 10 msec Interchar Delay = 20 msec Interchar Delay = 30 msec Interchar Delay = 40 msec Interchar Delay = 50 msec Interchar Delay = 60 msec Interchar Delay = 70 msec Interchar Delay = 80 msec Interchar Delay = 90 msec
4-12
QuickScan® QS6500/QS6500 BT
Page 49
Interface Features
RS-232 Interface Features, cont. START STATE Disable Software Flow Control Enable Software Flow Control
BARCODE
END
Product Reference Guide
4-13
Page 50
Interface Related Features
RS-232 Interface Features, cont. Host Echo When enabled, this feature passes all data through the imager to the host as it comes in. This feature is used for applications where “daisy chaining” of RS-232 devices onto the same cable is necessary. If, for example, one of the devices in the chain is a terminal where someone is entering data while another person is simultaneously scanning a bar code requiring transmission to the host, the scanner will wait for the RS-232 channel to be quiet for a specified period of time (set via RS-232 Host Echo Quiet Interval). The scanner can be set to observe this delay before sending its data in order to avoid RS-232 transmission conflicts.
Host Echo Quiet Interval This setting specifies the time interval of RS-232 channel inactivity which must transpire before the imager will break the host echo loop to transmit the bar code data that has just been scanned to the host.
Signal Voltage: Normal/TTL Specifies whether the RS-232 interface provides TTL levels on the output pins TxD and RTS.
RS-232 Invert Enables/disables inversion of RS-232 TXD and RXD signals.
4-14
QuickScan® QS6500/QS6500 BT
Page 51
Interface Features
RS-232 Interface Features, cont. START STATE
BARCODE
Disable Host Echo Enable Host Echo Host Echo Quiet Interval = 0msec Host Echo Quiet Interval = 10msec Host Echo Quiet Interval = 20msec Host Echo Quiet Interval = 30msec Host Echo Quiet Interval = 40msec Host Echo Quiet Interval = 50msec Host Echo Quiet Interval = 60msec Host Echo Quiet Interval = 70msec Host Echo Quiet Interval =80msec Host Echo Quiet Interval = 90msec
Product Reference Guide
4-15
Page 52
Interface Related Features
RS-232 Interface Features, cont. START STATE Host Echo Quiet Interval = 100msec Signal Voltage: Normal RS-232
BARCODE
Signal Voltage: TTL No TTL Inversion Invert TTL
END
Beep on ASCII BEL Enables/disables ability of imager to beep (sound a good read tone) on receiving an ASCII BEL (07 hex).
Beep on Not on File Select for the host to beep (or not) when a not-on-file (host command) condition is detected by the host.
ACK NAK Options This enables/disables the ability of the imager to support the RS-232 ACK/NAK protocol. When configured, the imager and/or host sends an “ACK” when it receives data properly, and sends “NAK” when the data is in error. Selections for this option are: •
4-16
Disable
QuickScan® QS6500/QS6500 BT
Page 53
Interface Features
•
Enable for label transmission, the imager expects an ACK/NAK response from the host when a label is sent
•
Enable for host-command acknowledge, the imager will respond with ACK/NAK when the host sends a command
•
Enable for label transmission and host-command acknowledge START STATE
BARCODE
Disable Beep on ASCII BEL Enable Beep on ASCII BEL Disable Beep on Not On File Enable Beep on Not On File Disable ACK NAK Enable ACK NAK for Transmission Enable ACK NAK for hostcommand acknowledge Enable ACK NAK for transmission and host-command END
Product Reference Guide
4-17
Page 54
Interface Related Features
RS-232 Interface Features, cont. ACK Character START MODE
BARCODE Sets the ACK character from the set of ASCII characters or any hex value from 0 to FF. To configure this feature, scan the “START” bar code above to place the unit in Programming Mode, then the “Set ACK Character,” followed by the digits from the Alphanumeric table in Appendix B, Alpha-Numeric Pad representing your desired character. Accept your selection by scanning the “SET” bar code below and finally, exit programming mode by scanning the “END” barcode below. DEFAULT SETTING FOR THIS FEATURE: 06 (0x06)
Set ACK Character SET
END
4-18
QuickScan® QS6500/QS6500 BT
Page 55
Interface Features
RS-232 Interface Features, cont. NAK Character START MODE
BARCODE Sets the NAK character from the set of ASCII characters or any hex value from 0 to FF. To configure this feature, scan the “START” bar code above to place the unit in Programming Mode, then the “Set NAK Character,” followed by the digits from the Alphanumeric table in Appendix B, Alpha-Numeric Pad representing your desired character. Accept your selection by scanning the “SET” bar code below and finally, exit programming mode by scanning the “END” barcode below. DEFAULT SETTING FOR THIS FEATURE: 21 (0x15)
Set NAK Character SET
END
Product Reference Guide
4-19
Page 56
Interface Related Features
RS-232 Interface Features, cont. Retry on ACK NAK Timeout Enables/disables retry after the configurable ACK NAK Timeout Value (set in the following feature) has expired. START STATE Disable Retry on ACK NAK Timeout Enable Retry on ACK NAK Timeout
BARCODE
END
4-20
QuickScan® QS6500/QS6500 BT