Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 14 of 38

QuickScan QS6500/QS6500BT Product Reference Guide: Symbologies, pages 119 to 128

Pages 119 to 128 of 336, from QuickScan QS6500/QS6500BT Product Reference Guide

The original document is the PDF (4.3 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the PSC QS6500BT and Datalogic QS6500BT Base

Page 119

EAN-8

EAN-8 The following options apply to the EAN-8 symbology.

Disable/Enable EAN-8 When disabled, the imager will not read EAN-8 bar codes.

Checksum Transmission Enable this option to transmit the checksum along with EAN-8 bar code data. START STATE

BARCODE

Disable EAN-8

Enable EAN-8 Don’t Send Checksum Send Checksum END

Product Reference Guide

6-31

Page 120

Symbologies

EAN-8, continued Truncate/Expand None, Turns off the truncation/expansion features listed below. Has no affect on the Truncate Leading/Ending feature. To turn it off, set leading/ending values to 00. NOTE Truncate NSD, The Number System Digit (NSD) which is usually a zero (0) in the leading position can be truncated (excluded) from scanned bar code data. Expand EAN-8 to EAN-13, Expands EAN-8 data to the EAN-13 data format. Selecting this feature also changes the symbology ID to match those required for EAN-13. START STATE Truncate NSD/ Expand to EAN-13: NONE

BARCODE

Truncate NSD Expand to EAN-13 END

6-32

QuickScan® QS6500/QS6500 BT

Page 121

EAN-8

EAN-8, continued Truncate Leading/Ending The leading or ending digits of bar code data characters can be truncated. Select from 00 (no truncation) to 15.

NOTE

The imager will beep instead of reading anything when the truncate value is more than the bar code data digits or the truncate leading value overlaps the truncate ending value.

START MODE BARCODE Sets from 00 to 15 characters to truncate from either the leading or ending characters of scanned bar code data. To configure this feature, scan the “START” bar code above to place the unit in Programming Mode, then the SET TRUNCATION: LEADING or SET TRUNCATION: ENDING, followed by the digits from the Alphanumeric table in Appendix B, Alpha-Numeric Pad representing the desired quantity of digits to trumcate from the message string. Accept your selection by scanning the “SET” bar code below and finally, exit programming mode by scanning the “END” barcode below. DEFAULT SETTING FOR THIS FEATURE: 00 (None) Set Truncation: Leading Set Truncation: Ending SET

END

Product Reference Guide

6-33

Page 122

Symbologies

EAN-8, continued Code I.D. Selection The Code I.D. for this symbology consists of one or two user-selectable ASCII characters. It can be appended previous to or following the transmitted EAN-8 bar code data depending on how this feature is enabled. Example: Setting the EAN-8 Code I.D.

To configure this feature: 1. Determine which character(s) you would like to use to represent the EAN-8 symbology. Reference Appendix A, ASCII Conversion Chart to find the corresponding hex values for your chosen character(s). In this example we’ll set a Code I.D. of “FF” to represent EAN-8. The hex value from the table corresponding to ‘F’ is 46. This value will be used in a step to follow. 2. Scan the START bar code 3. Scan the SET EAN-8 CODE I.D. bar code. 4. Turn to Appendix B, Alpha-Numeric Pad and scan the bar codes ‘4’ and ‘6’ (the value determined in an earlier step). Scan the bar codes ‘4’ and ‘6’ a second time to represent the second ‘F’ needed to identify the Code I.D. 5. Scan the SET bar code to accept the digits scanned. 6. Turn to the Data Editing chapter and scan the CODE ID POSITION: BEFORE BAR CODE DATA label. Features configured using the Data Editing chapter are universal and will affect all symbologies. NOTE

7. Scan the END bar code to exit Programming Mode. 8. The resulting message string for scanned EAN-8 labels would appear as follows: Scanned bar code data:

02345673

Resulting message string output: FF02345673 6-34

QuickScan® QS6500/QS6500 BT

Page 123

EAN-8

EAN-8, continued START STATE Set EAN-8 Code I.D. Character(s)

BARCODE

DEFAULT SETTING FOR THIS FEATURE: FF (4646 hex) Select 0000 to disable Code ID for this symbology only.

SET

END

Product Reference Guide

6-35

Page 124

Symbologies

EAN-8, continued EAN-8 Data Group Characters Once you’ve pre-set your desired Data Group Characters1 using the Data Group Characters feature found in Chapter 5, Data Editing, you can choose to output up to two of those pre-sets whenever an EAN-8 bar code is scanned.

NOTE

The options in this section set Data Group Characters for the EAN-8 symbology ONLY. If you wish to enable this feature for additional symbologies, turn to the options in the section specific to the other symbology(s).

To set this feature: 1. Determine which Data Group pre-set(s) to output. You can select up to two from the following: Data Group 1 * Data Group 2 * Data Group 3 * Data Group 4 For example, your choice might be Data Group 2 only; Data Groups 1 and 3; Data Groups 3 and 4; or no Data Groups. 2. Scan the START bar code to place the imager in Programming Mode. 3. Scan the SET EAN-8 DATA GROUP CHARACTERS bar code. 4. Turn to Appendix B, Alpha-Numeric Pad and scan the digits representing the Data Group designation(s) chosen in the first step above. A digit of value zero (0) selects “no group.” For example, scanning 3 and 0 would output only the character(s) set for Data Group 3 whenever an EAN-8 bar code was scanned. Scanning digits 1 and 2 would output both Data Groups 2 and 3. To select no Data Groups at all, scan 0, then 0 again. 5. Scan the SET bar code to accept the digits scanned. 6. Scan the END bar code to exit Programming Mode.

1. In that chapter, you can select which character(s) and position(s) to place Data Characters within scanned data output.

6-36

QuickScan® QS6500/QS6500 BT

Page 125

EAN-8

EAN-8, continued START STATE

BARCODE

Set EAN-8 Data Group(s) DEFAULT SETTING FOR THIS FEATURE: None (00) SET

END

Product Reference Guide

6-37

Page 126

Symbologies

EAN-8, continued Add-ons Add-ons (or supplemental characters) are commonly added to the end of EAN-8 bar codes. The imager will read the add-ons if they are enabled and in the field of view. Three add-on types are supported: 2-digit, 5digit and UCC/EAN 128. Supported options are: None, This option directs the imager to ignore add-on portion of a EAN-8 bar code but still read the main portion of the bar code. 2 Digits, The imager will read 2-digit add-ons with the EAN-8 label. 5 Digits, The imager will read 5-digit add-ons with the EAN-8 label. 2 and 5 Digits, The imager will read 2- and 5-digit add-ons with the

EAN-8 label. UCC/EAN 128, The imager will read UCC/EAN 128 add-ons with the EAN-8 label. 2-Digit & UCC/EAN 128, The imager will read 2-digit and UCC/

EAN 128 add-ons with the EAN-8 label. 5-Digit & UCC/EAN 128, The imager will read 5-digit and UCC/

EAN 128 add-ons with the EAN-8 label. All, The imager will read 2-digit, 5-digit and UCC/EAN 128 add-ons with the EAN-8 label.

6-38

QuickScan® QS6500/QS6500 BT

Page 127

EAN-8

EAN-8, continued START STATE

BARCODE

None 2-Digits 5-Digits 2 & 5-Digits UCC/EAN 128 2-Digit & UCC/ EAN 128 5-Digit & UCC/ EAN 128 All END

Product Reference Guide

6-39

Page 128

Symbologies

GTIN The following options apply to the GTIN label data format.

Disable/Enable GTIN When this feature is enabled, the imager will translate UPC/EAN labels to the 14 digit GTIN format.

Code I.D. Selection The Code I.D. for this symbology consists of one or two user-selectable ASCII characters. It can be appended previous to or following the transmitted GTIN bar code data depending on how this feature is enabled. Example: Setting the GTIN Code I.D.

To configure this feature: 1. Determine which character(s) you would like to use to represent the GTIN symbology. Reference Appendix A, ASCII Conversion Chart to find the corresponding hex values for your chosen character(s). In this example we’ll set a Code I.D. of “G” to represent GTIN. The value from the table corresponding to ‘G’ is 47. This value will be used in a step to follow. 2. Scan the START bar code 3. Scan the SET UPC-A CODE I.D. bar code. 4. Turn to Appendix B, Alpha-Numeric Pad and scan the bar codes ‘4’ and ‘7’ (the value 47 determined in an earlier step to represent a Code I.D. of ‘G’). 5. Scan the SET bar code to accept the digits scanned. 6. Turn to the Data Editing chapter and scan the CODE ID POSITION: BEFORE BAR CODE DATA label. Features configured using the Data Editing chapter are universal and will affect all symbologies. NOTE

7. Scan the END bar code to exit Programming Mode. 6-40

QuickScan® QS6500/QS6500 BT