The text of a manual · part 13 of 38
QuickScan QS6500/QS6500BT Product Reference Guide: Symbologies, pages 109 to 118
Pages 109 to 118 of 336, from QuickScan QS6500/QS6500BT Product Reference Guide
The original document is the PDF (4.3 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the PSC QS6500BT and Datalogic QS6500BT Base
Page 109
EAN-13
EAN-13, continued START STATE
BARCODE
Disable EAN-13
Enable EAN-13 Don’t Send Checksum Send Checksum Disable ISBN/ ISSN Enable ISBN/ ISSN END
Product Reference Guide
6-21
Page 110
Symbologies
EAN-13, continued ISBN ID Setting Sets the Code ID used for labels that are translated to ISBN/ISSN numbers. The Code I.D. for this symbology consists of one or two userselectable ASCII characters. It can be appended previous to or following the transmitted bar code data depending on how this feature is enabled. Example: Setting the ISBN ID
To configure this feature: 1. Determine which character(s) you would like to use to represent ISBN/ISSN translated labels. Reference Appendix A, ASCII Conversion Chart, to find the corresponding hex values for your chosen character(s). In this example we’ll set a Code I.D. of “I” to represent ISBN/ISSN. The value from the table corresponding to ‘I’ is 49. This value will be used in a step to follow. 2. Scan the START bar code 3. Scan the SET ISBN CODE I.D. bar code. 4. Turn to Appendix B, Alpha-Numeric Pad and scan the bar codes ‘4’ and ‘9’ (the value 49 determined in an earlier step to represent a Code I.D. of ‘I’). 5. Scan the SET bar code to accept the digits scanned. 6. Turn to the Data Editing chapter and scan the CODE ID POSITION: BEFORE BAR CODE DATA label. Features configured using the Data Editing chapter are universal and will affect all symbologies. NOTE
7. Scan the END bar code to exit Programming Mode. 8. The resulting message string for converted ISBN/ISSN labels would appear as follows: Scanned bar code data:
97801234565
Resulting message string output: I97801234565 6-22
QuickScan® QS6500/QS6500 BT
Page 111
EAN-13
EAN-13, continued START STATE
BARCODE
Set ISBN Code I.D. Character(s) DEFAULT SETTING FOR THIS FEATURE: I (49 hex) Select 0000 to disable Code ID for this symbology only.
SET
END
Product Reference Guide
6-23
Page 112
Symbologies
EAN-13, continued Truncate Leading/Ending The leading or ending digits of bar code data characters can be truncated. Select from 00 (no truncation) to 15.
NOTE
The imager will beep instead of reading anything when the truncate value is more than the bar code data digits or the truncate leading value overlaps the truncate ending value.
START MODE BARCODE Sets from 00 to 15 characters to truncate from either the leading or ending characters of scanned bar code data. To configure this feature, scan the “START” bar code above to place the unit in Programming Mode, then the SET TRUNCATION: LEADING or SET TRUNCATION: ENDING, followed by the digits from the Alphanumeric table in Appendix B, Alpha-Numeric Pad representing the desired quantity of digits to trumcate from the message string. Accept your selection by scanning the “SET” bar code below and finally, exit programming mode by scanning the “END” barcode below. DEFAULT SETTING FOR THIS FEATURE: 00 (None) Set Truncation: Leading Set Truncation: Ending SET
END
6-24
QuickScan® QS6500/QS6500 BT
Page 113
EAN-13
EAN-13, continued Code I.D. Selection The Code I.D. for this symbology consists of one or two user-selectable ASCII characters. It can be appended previous to or following the transmitted EAN-13 bar code data depending on how this feature is enabled. Example: Setting the EAN-13 Code I.D.
To configure this feature: 1. Determine which character(s) you would like to use to represent the EAN-13 symbology. Reference Appendix A, ASCII Conversion Chart to find the corresponding hex values for your chosen character(s). In this example we’ll set a Code I.D. of “F” to represent EAN-13. The hex value from the table corresponding to ‘F’ is 46. This value will be used in a step to follow. 2. Scan the START bar code 3. Scan the SET EAN-13 CODE I.D. bar code. 4. Turn to Appendix B, Alpha-Numeric Pad and scan the bar codes ‘4’ and ‘6’ (the value determined in an earlier step). 5. Scan the SET bar code to accept the digits scanned. 6. Turn to the Data Editing chapter and scan the CODE ID POSITION: BEFORE BAR CODE DATA label. Features configured using the Data Editing chapter are universal and will affect all symbologies. NOTE
7. Scan the END bar code to exit Programming Mode. 8. The resulting message string for scanned EAN-13 labels would appear as follows: Scanned bar code data:
023456788122
Resulting message string output: F023456788122
Product Reference Guide
6-25
Page 114
Symbologies
EAN-13, continued START STATE
BARCODE
Set EAN-13 Code I.D. Character(s) DEFAULT SETTING FOR THIS FEATURE: F (46 hex) Select 0000 to disable Code ID for this symbology only.
SET
END
6-26
QuickScan® QS6500/QS6500 BT
Page 115
EAN-13
EAN-13, continued EAN-13 Data Group Characters Once you’ve pre-set your desired Data Group Characters1 using the Data Group Characters feature found in Chapter 5, Data Editing, you can choose to output up to two of those pre-sets whenever an EAN-13 bar code is scanned.
NOTE
The options in this section set Data Group Characters for the EAN-13 symbology ONLY. If you wish to enable this feature for additional symbologies, turn to the options in the section specific to the other symbology(s).
To set this feature: 1. Determine which Data Group pre-set(s) to output. You can select up to two from the following: Data Group 1 * Data Group 2 * Data Group 3 * Data Group 4 For example, your choice might be Data Group 2 only; Data Groups 1 and 3; Data Groups 3 and 4; or no Data Groups. 2. Scan the START bar code to place the imager in Programming Mode. 3. Scan the SET EAN-13 DATA GROUP CHARACTERS bar code. 4. Turn to Appendix B, Alpha-Numeric Pad and scan the digits representing the Data Group designation(s) chosen in the first step above. A digit of value zero (0) selects “no group.” For example, scanning 3 and 0 would output only the character(s) set for Data Group 3 whenever an EAN-13 bar code was scanned. Scanning digits 1 and 2 would output both Data Groups 2 and 3. To select no Data Groups at all, scan 0, then 0 again. 5. Scan the SET bar code to accept the digits scanned. 6. Scan the END bar code to exit Programming Mode.
1. In that chapter, you can select which character(s) and position(s) to place Data Characters within scanned data output.
Product Reference Guide
6-27
Page 116
Symbologies
EAN-13, continued START STATE
BARCODE
Set EAN-13 Data Group(s) DEFAULT SETTING FOR THIS FEATURE: None (00) SET
END
6-28
QuickScan® QS6500/QS6500 BT
Page 117
EAN-13
EAN-13, continued Add-ons Add-ons (or supplemental characters) are commonly added to the end of EAN-13 bar codes. The imager will read the add-ons if they are enabled and in the field of view. Three add-on types are supported: 2-digit, 5digit and UCC/EAN 128. Supported options are: None, This option directs the imager to ignore add-on portion of a EAN-13 bar code but still read the main portion of the bar code. 2 Digits, The imager will read 2-digit add-ons with the EAN-13 label. 5 Digits, The imager will read 5-digit add-ons with the EAN-13 label. 2 and 5 Digits, The imager will read 2- and 5-digit add-ons with the
EAN-13 label. UCC/EAN 128, The imager will read UCC/EAN 128 add-ons with the EAN-13 label. 2-Digit & UCC/EAN 128, The imager will read 2-digit and UCC/
EAN 128 add-ons with the EAN-13 label. 5-Digit & UCC/EAN 128, The imager will read 5-digit and UCC/
EAN 128 add-ons with the EAN-13 label. All, The imager will read 2-digit, 5-digit and UCC/EAN 128 add-ons with the EAN-13 label.
Product Reference Guide
6-29
Page 118
Symbologies
EAN-13, continued START STATE
BARCODE
None 2-Digits 5-Digits 2 & 5-Digits UCC/EAN 128 2-Digit & UCC/ EAN 128 5-Digit & UCC/ EAN 128 All
END
6-30