The text of a manual · part 7 of 11
QuickScan QS2500 Handheld Bar Code Scanner Product Reference Guide: Symbology Settings, pages 47 to 55
Pages 47 to 55 of 74, from QuickScan QS2500 Handheld Bar Code Scanner Product Reference Guide
The original document is the PDF (498 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the PSC QS-2500 and Datalogic QS-2500
Page 47
•
Append label data with Concatenation Code <GS> (1Dhex):<]C1> <Label data 1> <GS> <Label data 2><Checksum> Start Program $
Option Bar Code
Read
Checksum Verification
Checksum Transmission
Max. Code Length
Min. Code Length
Alphanumeric Entry
Option Disable
00
Enable
01*
Disable
00
Enable
01*
Disable
00*
Enable
01
Use Global Max.
00*
1–64
01–64
Use Global Min.
00*
1–64
01–64
0–15
00–15 00*
0–15
00–15 00*
Truncate Leading
Truncate Ending
Code ID Setting
00–ffhex ASCII code 0–44
Insertion Group Selection
Format
00–ffhex<#>*
00–44 00*
Standard
00*
UCC/EAN-128
01
Page 48
Option Bar Code
Append
UCC/EAN-128ID Setting
Concatenation Code
Alphanumeric Entry
Option Disable
00*
Enable
01
00–ffhex ASCII code
00–ffhex<#>*
00–ffhex ASCII code
00–ffhex1Dhex* Exit
$ $
Read: Format: Data Digits (Variable)
Checksum1 (Optional)
Checksum1 (Optional)
Checksum Verification: The checksum is presented as the sum mod 47 of the numerical values of all data digits. Checksum Transmission: When this option is enabled, the QS2500 will transmit the checksum. Maximum/Minimum Code Length: Same as Code 39. See page 33. Truncate Leading/Ending: Same as UPC-A. See page 25. Code ID Setting: Same as UPC-A. See page 25. Insertion Group Selection: Same as UPC-A. See page 25.
Page 49
Start Program $
Option Bar Code
Read
Checksum Verification
Checksum Transmission
Max. Code Length
Min. Code Length
Option Disable
00*
Enable
01
Disable
00
Enable (two digits)
01*
Disable
00*
Enable
01
Use Global Max.
00*
1–64
01–64
Use Global Min.
00*
1–64
01–64
0–15
00–15 00*
0–15
00–15 00*
Truncate Leading
Truncate Ending
Code ID Setting
00–ffhex ASCII code 0–44
Insertion Group Selection
Alphanumeric Entry
00–ffhex<&>*
00–44 00* Exit
Product Reference Guide
45
Page 50
Read: Format: Data Digits (Variable)
Checksum1 (Optional)
Checksum1 (Optional)
Checksum Verification: The checksum is presented as the sum mod 11 of all data digits. Checksum Transmission: When this option is enabled, the QS2500 will transmit one-digit or two-digit checksums, depending upon the setting for checksum verification. Maximum/Minimum Code Length: Same as Code 39. See page 33. Truncate Leading/Ending: Same as UPC-A. See page 25. Code ID Setting: Same as UPC-A. See page 25. Insertion Group Selection: Same as UPC-A. See page 25. Start Program
Option Bar Code
Read
Checksum Verification
Checksum Transmission
Max. Code Length
Option
Alphanumeric Entry
Disable
00*
Enable
01
Disable
00
One digit
01*
Two digit
02
Disable
00*
Enable
01
Use Global Max.
00*
1–64
01–64
Page 51
Option
Alphanumeric Entry
Use Global Min.
00*
1–64
01–64
0–15
00–15 00*
0–15
00–15 00*
Option Bar Code
Min. Code Length Truncate Leading
Truncate Ending
Code ID Setting
00–ffhex ASCII code 0–44
00–ffhex<O>*
00–44 00*
Insertion Group Selection
Exit
MSI/Plessey Read: Format: Data Digits (Variable)
Checksum1 (Optional)
Checksum2 (Optional)
Checksum Verification: The MSI/Plessey code has one or two optional checksum digits. The checksums are calculated as the sum mod 10 or 11 of the data digits. Checksum Transmission: When this option is enabled, the QS2500 will transmit one-digit or two-digit checksums, depending upon the setting for checksum verification. Maximum/Minimum Code Length: Same as Code 39. See page 33. Truncate Leading/Ending: Same as UPC-A. See page 25. Code ID Setting: Same as UPC-A. See page 25.
Product Reference Guide
47
Page 52
Insertion Group Selection: Same as UPC-A. See page 25. Start Program $
Option Bar Code
Read
Checksum Verification
Checksum Transmission
Max. Code Length
Mini. Code Length
Option Disable
00*
Enable
01
Disable
00*
Mod 10
01
Mod 10/10
02
Mod 11/10
03
Disable
00*
Enable
01
Use Global Max.
00*
1–64
01–64
Use Global Min.
00*
1–64
01–64
0–15
00–15 00*
0–15
00–15 00*
Truncate Leading
Truncate Ending
Alphanumeric Entry
Page 53
Option Bar Code
Option 00–ffhex ASCII code
Code ID Setting
0–44 Insertion Group Selection
Alphanumeric Entry 00–ffhex<@>*
00–44 00* Exit
UK/Plessey Read: Format: Data Digits (Variable)
Checksum1+2 (Optional)
Checksum Verification: The UK/Plessey code has one or two optional checksum digits. The checksums are calculated as the sum mod 10 or 11 of the data digits. Checksum Transmission: When this option is enabled, the QS2500 will transmit the checksum. Maximum/Minimum Code Length: Same as Code 39. See page 33. Truncate Leading/Ending: Same as UPC-A. See page 25. Code ID Setting: Same as UPC-A. See page 25. Insertion Group Selection: Same as UPC-A. See page 25.
Product Reference Guide
49
Page 54
Start Program
Option Bar Code
Read
Checksum Verification
Checksum Transmission
Max. Code Length
Min. Code Length
Option Disable
00*
Enable
01
Disable
00
Enable
01*
Disable
00*
Enable
01
Use Global Max.
00*
1–64
01–64
Use Global Min.
00*
1–64
01–64
0–15
00–15 00*
0–15
00–15 00*
Truncate Leading
Truncate Ending
Code ID Setting
00–ffhex ASCII code 0–44
Insertion Group Selection
Alphanumeric Entry
00–ffhex<@>*
00–44 00* Exit
Page 55
Telepen Read: Format: Data Digits
Checksum1 (Optional)
Checksum Verification: The checksum is presented as the sum mod 10 or
11 of the data digits. Checksum Transmission: When this option is enabled, the QS2500 will transmit the checksum. Maximum/Minimum Code Length: Same as Code 39. See page 33. Truncate Leading/Ending: Same as UPC-A. See page 25. Code ID Setting: Same as UPC-A. See page 25. Insertion Group Selection: Same as UPC-A. See page 25. Format: Numeric data only. Full ASCII data. Start Program $
Option Bar Code
Read
Checksum Verification
Checksum Transmission
Max. Code Length
Product Reference Guide
Option
Alphanumeric Entry
Disable
00*
Enable
01
Disable
00*
Enable
01
Disable
00*
Enable
01
Use Global Max.
00*
1–64
01–64
51