The text of a manual · part 6 of 11
QuickScan QS2500 Handheld Bar Code Scanner Product Reference Guide: Symbology Settings, pages 38 to 46
Pages 38 to 46 of 74, from QuickScan QS2500 Handheld Bar Code Scanner Product Reference Guide
The original document is the PDF (498 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the PSC QS-2500 and Datalogic QS-2500
Page 38
Append: This function allows several symbols to be concatenated and be treated as a single entry. The QS2500 will not transmit the embedded appending code (for Code-39, a space). If the append function is enabled and other symbols are read again with the appended code, then the codes are transmitted without the code ID, preamble, or prefix. When a symbol was decoded without the appended code, the data is transmitted without the code ID and prefix, but the postamble suffix codes are appended. This function is used when the first character of Code 39 data is a space. Start/End Transmission: The start and end characters of Code 39 are asterisks (*). You can transmit all data digits, including the two asterisks.
Start Program $
Option Bar Code
Read Checksum Verification Checksum Transmission Maximum Code Length Minimum Code Length
Option Disable
00
Enable
01*
Disable
00*
Enable
01
Disable
00*
Enable
01
Use Global Max.
00*
1–64
01–64
Use Global Min.
00*
1–64
01–64
0–15
00–15 00*
0–15
00–15 00*
Truncate Leading Truncate Ending Code ID Setting
Alphanumeric Entry
00–ffhex ASCII code
00–ffhex<*>
Page 39
Option Bar Code
Option 0–44
00–44 00*
Insertion Group Selection Format Append Start/End Transmission
Alphanumeric Entry
Standard ASCII
00*
Full ASCII
01
Disable
00*
Enable
01
Disable
00*
Enable
01 Exit $ $
Interleaved 2 of 5 Read: Format: Data Digits (Variable)
Checksum (Optional)
Checksum Verification: The checksum is presented as the sum mod 10 of the numerical values of all data digits. Checksum Transmission: When this option is enabled, the QS2500 will transmit the checksum. Maximum/Minimum Code Length: Same as Code 39. See page 33. (Even values only) Truncate Leading/Ending: Same as UPC-A. See page 25. Code ID Setting: Same as UPC-A. See page 25. Insertion Group Selection: Same as UPC-A. See page 25.
Product Reference Guide
35
Page 40
Start Program $
Option Bar Code
Read
Checksum Verification
Checksum Transmission
Max.Code Length
Option Disable
00
Enable
01*
Disable
00
Enable
01*
Disable
00*
Enable
01
Use Global Max.
00*
2–64
02–64
Use Global Min.
00*
(even values only)
Min. Code Length
2–64
02–64
(even values only)
0–15
00–15 00*
0–15
00–15 00*
Truncate Leading
Truncate Ending
Code ID Setting
Alphanumeric Entry
00–ffhex ASCII code 0–44
00–ffhex<i>*
00–44 00*
Insertion Group Selection
Exit $ $
Page 41
Industrial 2 of 5 Read: Format: Data Digits (Variable)
Checksum (Optional)
Maximum/Minimum Code Length: Same as Code 39. See page 33. Truncate Leading/Ending: Same as UPC-A. See page 25. Code ID Setting: Same as UPC-A. See page 25. Insertion Group Selection: Same as UPC-A. See page 25. Start Program $
Option Bar Code
Read
Max. Code Length
Min. Code Length
Option Disable
00*
Enable
01
Use Global Max.
00*
1–64
01–64
Use Global Min.
00*
1–64
01–64
0–15
00–15 00*
0–15
00–15 00*
Truncate Leading
Truncate Ending
Product Reference Guide
Alphanumeric Entry
37
Page 42
Option Bar Code
Option 00–ffhex ASCII code
Code ID Setting
0–44 Insertion Group Selection
Alphanumeric Entry 00–ffhex<i>*
00–44 00* Exit
Read: Format: Data Digits (Variable)
Checksum (Optional)
Checksum Verification: The checksum is presented as the sum mod 10 of the numerical values of all data digits. Checksum Transmission: When this option is enabled, the QS2500 will transmit the checksum. Maximum/Minimum Code Length: Same as Code 39. See page 33. Truncate Leading/Ending: Same as UPC-A. See page 25. Code ID Setting: Same as UPC-A. See page 25. Insertion Group Selection: Same as UPC-A. See page 25.
Page 43
Start Program $
Option Bar Code
Read
Checksum Verification
Checksum Transmission
Max. Code Length
Min. Code Length
Option Disable
00*
Enable
01
Disable
00*
Enable
01
Disable
00*
Enable
01
Use Global Max.
00*
1–64
01–64
Use Global Min.
00*
1–64
01–64
0–15
00–15 00*
0–15
00–15 00*
Truncate Leading
Truncate Ending
Code ID Setting
Alphanumeric Entry
00–ffhex ASCII code 0–44
00–ffhex<B>*
00–44 00*
Insertion Group Selection
Exit $ $
Product Reference Guide
39
Page 44
&RGDEDU Read: Format: Start
Data Digits (Variable)
Checksum (Optional)
End
Checksum Verification: The checksum is presented as the sum mod 16 of the numerical values of all data digits. Checksum Transmission: When this option is enabled, the QS2500 will transmit the checksum. Maximum/Minimum Code Length: Same as Code 39. See page 33. Truncate Leading/Ending: Same as UPC-A. See page 25. Code ID Setting: Same as UPC-A. See page 25. Insertion Group Selection: Same as UPC-A. See page 25. Start/End Type: Codabar has four pairs of Start/End patterns. Select one pair to match your application. Start/End Transmission: Same as Code 39. See page 34. Start Program $
Option Bar Code
Read
Checksum Verification
Checksum Transmission
Option
Alphanumeric Entry
Disable
00*
Enable
01
Disable
00*
Enable
01
Disable
00*
Enable
01
Page 45
Option
Alphanumeric Entry
Use Global Max.
00*
1–64
01–64
Use Global Min.
00*
1–64
01–64
0–15
00–15 00*
0–15
00–15 00*
Option Bar Code
Max. Code Length
Min. Code Length
Truncate Leading
Truncate Ending
Code ID Setting
00–ffhex ASCII code 0–44
00–44 00*
Insertion Group Selection
Start/End Type
Start/End Transmission
00–ffhex<%>*
ABCD/ABCD
00* abcd/abcd
01
ABCD/TN*E
02 abcd/tn*e
03
Disable
00*
Enable
01 Exit $ $
Product Reference Guide
41
Page 46
Read: Format: Data Digits (Variable)
Checksum (Optional)
Checksum Verification: The checksum is presented as the sum mod 103 of all data digits. Checksum Transmission: When this option is enabled, the QS2500 will transmit the checksum. Maximum/Minimum Code Length: Same as Code 39. See page 33. Truncate Leading/Ending: Same as UPC-A. See page 25. Code ID Setting: Same as UPC-A. See page 25. Insertion Group Selection: Same as UPC-A. See page 25. Format: The Code 128 data string can be translated to UCC/EAN-128 format if it starts with “FNC1”. The first “FNC1” will be translated to “]C1”, and the second “FNC1” to a concatenation code “<GS>(1Dhex)”. ]C1
Data
<GS>
Data
Checksum
Append: When the function is enabled, it won't show the data immediately if scanner read the barcode includes FNC2 code. It will show all data until it read a barcode, which doesn't have FNC2 code. ]C2
Data
<GS>
Data
Checksum
Concatenation Code: This feature is only used for UCC/EAN-128. The Concatenation Code is the separator character, default is <GS> (1Dhex), inserted between characters when label data is concatenated and treated as a single entry.
For example: •