Page 38

Append: This function allows several symbols to be concatenated and be treated as a single entry. The QS2500 will not transmit the embedded appending code (for Code-39, a space). If the append function is enabled and other symbols are read again with the appended code, then the codes are transmitted without the code ID, preamble, or prefix. When a symbol was decoded without the appended code, the data is transmitted without the code ID and prefix, but the postamble suffix codes are appended. This function is used when the first character of Code 39 data is a space. Start/End Transmission: The start and end characters of Code 39 are asterisks (*). You can transmit all data digits, including the two asterisks.

Start Program $

Option Bar Code

Read Checksum Verification Checksum Transmission Maximum Code Length Minimum Code Length

Option Disable

00

Enable

01*

Disable

00*

Enable

01

Disable

00*

Enable

01

Use Global Max.

00*

1–64

01–64

Use Global Min.

00*

1–64

01–64

0–15

00–15 00*

0–15

00–15 00*

Truncate Leading Truncate Ending Code ID Setting

Alphanumeric Entry

00–ffhex ASCII code

00–ffhex<*>

Page 39

Option Bar Code

Option 0–44

00–44 00*

Insertion Group Selection Format Append Start/End Transmission

Alphanumeric Entry

Standard ASCII

00*

Full ASCII

01

Disable

00*

Enable

01

Disable

00*

Enable

01 Exit $ $

Interleaved 2 of 5 Read: Format: Data Digits (Variable)

Checksum (Optional)

Checksum Verification: The checksum is presented as the sum mod 10 of the numerical values of all data digits. Checksum Transmission: When this option is enabled, the QS2500 will transmit the checksum. Maximum/Minimum Code Length: Same as Code 39. See page 33. (Even values only) Truncate Leading/Ending: Same as UPC-A. See page 25. Code ID Setting: Same as UPC-A. See page 25. Insertion Group Selection: Same as UPC-A. See page 25.

Product Reference Guide

35

Page 40

Start Program $

Option Bar Code

Read

Checksum Verification

Checksum Transmission

Max.Code Length

Option Disable

00

Enable

01*

Disable

00

Enable

01*

Disable

00*

Enable

01

Use Global Max.

00*

2–64

02–64

Use Global Min.

00*

(even values only)

Min. Code Length

2–64

02–64

(even values only)

0–15

00–15 00*

0–15

00–15 00*

Truncate Leading

Truncate Ending

Code ID Setting

Alphanumeric Entry

00–ffhex ASCII code 0–44

00–ffhex<i>*

00–44 00*

Insertion Group Selection

Exit $ $

Page 41

Industrial 2 of 5 Read: Format: Data Digits (Variable)

Checksum (Optional)

Maximum/Minimum Code Length: Same as Code 39. See page 33. Truncate Leading/Ending: Same as UPC-A. See page 25. Code ID Setting: Same as UPC-A. See page 25. Insertion Group Selection: Same as UPC-A. See page 25. Start Program $

Option Bar Code

Read

Max. Code Length

Min. Code Length

Option Disable

00*

Enable

01

Use Global Max.

00*

1–64

01–64

Use Global Min.

00*

1–64

01–64

0–15

00–15 00*

0–15

00–15 00*

Truncate Leading

Truncate Ending

Product Reference Guide

Alphanumeric Entry

37

Page 42

Option Bar Code

Option 00–ffhex ASCII code

Code ID Setting

0–44 Insertion Group Selection

Alphanumeric Entry 00–ffhex<i>*

00–44 00* Exit

Read: Format: Data Digits (Variable)

Checksum (Optional)

Checksum Verification: The checksum is presented as the sum mod 10 of the numerical values of all data digits. Checksum Transmission: When this option is enabled, the QS2500 will transmit the checksum. Maximum/Minimum Code Length: Same as Code 39. See page 33. Truncate Leading/Ending: Same as UPC-A. See page 25. Code ID Setting: Same as UPC-A. See page 25. Insertion Group Selection: Same as UPC-A. See page 25.

Page 43

Start Program $

Option Bar Code

Read

Checksum Verification

Checksum Transmission

Max. Code Length

Min. Code Length

Option Disable

00*

Enable

01

Disable

00*

Enable

01

Disable

00*

Enable

01

Use Global Max.

00*

1–64

01–64

Use Global Min.

00*

1–64

01–64

0–15

00–15 00*

0–15

00–15 00*

Truncate Leading

Truncate Ending

Code ID Setting

Alphanumeric Entry

00–ffhex ASCII code 0–44

00–ffhex<B>*

00–44 00*

Insertion Group Selection

Exit $ $

Product Reference Guide

39

Page 44

&RGDEDU Read: Format: Start

Data Digits (Variable)

Checksum (Optional)

End

Checksum Verification: The checksum is presented as the sum mod 16 of the numerical values of all data digits. Checksum Transmission: When this option is enabled, the QS2500 will transmit the checksum. Maximum/Minimum Code Length: Same as Code 39. See page 33. Truncate Leading/Ending: Same as UPC-A. See page 25. Code ID Setting: Same as UPC-A. See page 25. Insertion Group Selection: Same as UPC-A. See page 25. Start/End Type: Codabar has four pairs of Start/End patterns. Select one pair to match your application. Start/End Transmission: Same as Code 39. See page 34. Start Program $

Option Bar Code

Read

Checksum Verification

Checksum Transmission

Option

Alphanumeric Entry

Disable

00*

Enable

01

Disable

00*

Enable

01

Disable

00*

Enable

01

Page 45

Option

Alphanumeric Entry

Use Global Max.

00*

1–64

01–64

Use Global Min.

00*

1–64

01–64

0–15

00–15 00*

0–15

00–15 00*

Option Bar Code

Max. Code Length

Min. Code Length

Truncate Leading

Truncate Ending

Code ID Setting

00–ffhex ASCII code 0–44

00–44 00*

Insertion Group Selection

Start/End Type

Start/End Transmission

00–ffhex<%>*

ABCD/ABCD

00* abcd/abcd

01

ABCD/TN*E

02 abcd/tn*e

03

Disable

00*

Enable

01 Exit $ $

Product Reference Guide

41

Page 46

Read: Format: Data Digits (Variable)

Checksum (Optional)

Checksum Verification: The checksum is presented as the sum mod 103 of all data digits. Checksum Transmission: When this option is enabled, the QS2500 will transmit the checksum. Maximum/Minimum Code Length: Same as Code 39. See page 33. Truncate Leading/Ending: Same as UPC-A. See page 25. Code ID Setting: Same as UPC-A. See page 25. Insertion Group Selection: Same as UPC-A. See page 25. Format: The Code 128 data string can be translated to UCC/EAN-128 format if it starts with “FNC1”. The first “FNC1” will be translated to “]C1”, and the second “FNC1” to a concatenation code “<GS>(1Dhex)”. ]C1

Data

<GS>

Data

Checksum

Append: When the function is enabled, it won't show the data immediately if scanner read the barcode includes FNC2 code. It will show all data until it read a barcode, which doesn't have FNC2 code. ]C2

Data

<GS>

Data

Checksum

Concatenation Code: This feature is only used for UCC/EAN-128. The Concatenation Code is the separator character, default is <GS> (1Dhex), inserted between characters when label data is concatenated and treated as a single entry.

For example: •

UCC/EAN-128 Structure: <start> <FNC1> <Label data 1> <FNC1> <Label data 2> <CK> <stop>