Page 51

Symbology selection (bar code type) determines which symbologies the scanner will decode. Once you have identified the symbologies you wish to enable, turn to the following pages, enable those symbologies and set the data format options (e.g. check digit, start/stop characters) required by your host system for each symbology type. You must enable the symbology format options settings that are compatible with your host system. The factory settings for each interface were chosen to meet the standard industry requirements and in most cases you will not need to change the symbology format settings. If you are unsure of your system requirements, test the scanner using the factory settings before making any changes.

R44-2018

45

SYMBOLOGY SELECTION

Symbologies

Page 52

SYMBOLOGY SELECTION

Symbology Options Overview Enable All Symbologies, allows the scanner to auto-discriminate between all the symbologies in this list. Use this selection only if you must constantly read a wide variety of symbologies. Turn to the following pages for enabling additional symbology specific options. Disable All Symbologies, disables all symbologies1. The scanner will only recognize the programming labels contained in this manual while you are in Programming Mode. Enable UPC/EAN, tells the scanner to recognize UPC-A, UPC-E, EAN8, and EAN-13. If you enable this symbology, additional options for symbology expansion and reading add-ons are available. Allows selection of expansion and add-on options. Enable Code 39, selects Code 39 as an active symbology. Allows selection of Check Digit, Start/Stop and Single Digit options. PharmaCode 39, is a symbology subset of Code 39. Enabling PharmaCode 39 selects this special Italian code as the active Code 39 symbology (superceding standard Code 39 features). NOTE Standard Code 39 must be enabled before PharmaCode can be enabled. Enable Interleaved 2 of 5, selects Interleaved 2 of 5 as an active symbology. Allows change of Check Digit or label format (fixed or variable length) options. Enable Standard 2 of 5, selects Standard 2 of 5 as an active symbology. Options for this symbology are similar to Interleaved 2 of 5 features. 1

46

Code 128 is always active for the purpose of reading programming bar code labels, however, the scanner does not transmit data to the host when in Programming Mode. Scanning the DISABLE ALL SYMBOLOGIES label will disable Code 128 transmission to the host.

QuickScan™ 1000 Programming Guide

Page 53

NOTE Standard 2 of 5 must be enabled before IATA can be enabled. Enable Codabar, selects Codabar as an active symbology. Allows selection of Check Digit, Start/Stop character and format, or label format (fixed or variable length) options. EnableCode93, selectsCode93asanactivesymbology. Thescannerispreset to recognize all Code 93 bar codes that have between 2 and 50 characters. Code 93 has no user selectable options. Enable Code 1281, selects Code 128 as an active symbology. The scanner is preset to recognize all Code 128 bar codes that have between 2 and 50 characters. Code 128 has no user selectable options. Enable MSI/Plessey2, selects MSI/Plessey as an active symbology. Allows selection of Check Digit or label format (fixed or variable length) options.

Universal Symbology Selection To set the scanner to read all symbologies, scan the ENABLE ALL SYMBOLOGIES bar code below. NOTE DO NOT scan SET or END bar codes when programming universal symbology features. Programming mode is automatically entered and exited when one of the two special bar codes below are scanned.

Enable All Symbologies

Disable All Symbologies1

1 2

Code 128 is always active for the purpose of reading programming bar code labels, however, the scanner does not transmit data to the host when in Programming Mode. MSI/Plessey may not be supported for your scanner. Contact your distributor, PSC Sales or PSC Technical Support for more information.

R44-2018

47

SYMBOLOGY SELECTION

IATA, is a special symbology subset of Standard 2 of 5. Enabling IATA selects this custom code as the active Standard 2 of 5 symbology (superceding any other Standard 2 of 5 features).

Page 54

SYMBOLOGY SELECTION

Symbology Selection The bar code programming labels on the following pages allow you to enable or disable individual symbologies.

NOTE If you enable a symbology that has additional features that should be set, turn to the pages that support that symbology and its programmable features.

SET --------------------------------------------------------- ENABLE UPC/EAN

DISABLE UPC/EAN --------

-------- ENABLE CODE 39

DISABLE CODE 39 -----------

-------- ENABLE PHARMACODE2 39 DISABLE PHARMACODE 39 --

2

48

Code 39 must first be enabled for the scanner to read PharmaCode 39 labels. Enabling PharmaCode 39 will convert Code 39 data to PharmaCode format whenever possible.

QuickScan™ 1000 Programming Guide

Page 55

DISABLE INTERLEAVED 2 OF 5

-------- ENABLE STANDARD 2 OF 5

DISABLE STANDARD 2 OF 5 -

-------- ENABLE IATA 3

DISABLE IATA ---------------

3

Standard 2 of 5 must first be enabled before IATA can be enabled, however, the scanner will not read Standard 2 of 5 labels when IATA is enabled.

R44-2018

49

SYMBOLOGY SELECTION

-------- ENABLE INTERLEAVED 2 OF 5

Page 56

SYMBOLOGY SELECTION

-------- ENABLE CODABAR

DISABLE CODABAR ------------

-------- ENABLE CODE 93

DISABLE CODE 93 -----------

-------- ENABLE CODE 128 DISABLE C ODE 128 4 ---------------- ENABLE MSI/P LESSEY 5

DISABLE MSI/PLESSEY ------

----------------------------------------------- END

4

5

50

Code 128 is always active for the purpose of reading programming bar code labels. Scanning the DISABLE ALL SYMBOLOGIES or the DISABLE CODE 128 labels disables Code 128 transmission to the host (disables decoding of all C128 nonprogramming labels). MSI/Plessey may not be supported for your scanner. Contact your distributor, PSC Sales or PSC Technical Support for more information.

QuickScan™ 1000 Programming Guide

Page 57

SYMBOLOGY SELECTION

UPC/EAN Options The information below provides a brief description of the programmable UPC/EAN features included on the following pages. Expand UPC-A to EAN-13, adds a leading zero to a UPC-A label which 'expands' the label to the EAN-13 data format. Selecting this feature also changes the symbology ID to match those required for EAN-13. Expand UPC-E to UPC-A, expands UPC-E labels to UPC-A data format. Selecting this feature also changes the symbology ID to match those required for UPC-A. If this feature and Expand UPC-A to EAN-13 are both enabled, label data will be sent to the host in EAN-13 label format. Expand EAN-8 to EAN-13, adds five zeros in front of an EAN-8 label. Data is sent in EAN-13 data format. Selecting this feature also changes the symbology ID to match those required for EAN-13. Expand UPC-E to EAN-13, expands UPC-E labels to EAN-13 data format. Selecting this feature also changes the symbology ID to match those required for EAN-13. UPC-A or UPC-E and EAN-8 or EAN-13 Two and Five Digit AddOns Optional, scanner will read UPC/EAN bar codes with or without add-ons. Required, UPC/EAN bar codes must have add-on or label will not be read. Disable, scanner will not recognize/read add-on portion of UPC/ EAN labels, but will read the main body of the label. Price/Weight Check Digit, provides options for enabling price/ weight check digits. The feature includes selections for domestic four or five digit, and European four or five digit, as well as the option to disable the price/weight check.

R44-2018

51

Page 58

Use these labels to enable or disable: •

Expand UPC-A to EAN-13

•

Expand EAN-8 to EAN-13

•

Expand UPC-E to UPC-A

•

Expand UPC-E to EAN-13

UPC-A TO EAN-13

EXPANSION

UPC-E TO UPC-A

EXPANSION

EAN-8 TO EAN-13

EXPANSION EXPANSION

SET --------------------------------------------------

UPC-E TO EAN-13

SYMBOLOGY SELECTION

UPC/EAN Expansion

-------- EXPAND1 DON'T EXPAND ---------------------- EXPAND1 DON'T EXPAND ---------------------- EXPAND1 DON'T EXPAND ---------------------- EXPAND1 DON'T EXPAND ------------------------------------------------------------- END

1

52

When any expansion feature is enabled, the transmission of the Prefix, Suffix, Check Digit and Number System Digit (NSD) are controlled by your selections for the symbology 'expanded to' rather than the symbology 'expanded from'. For example, if you expand UPC-E to UPC-A, settings for UPC-A determine how the scanner sends a bar code's contents.

QuickScan™ 1000 Programming Guide

Page 59

If you need to scan UPC or EAN labels that include Add-on codes, the selections on this page set the scanner's Add-on feature. There are three Add-on read modes available: optional, required and disabled. Optional, the scanner will recognize UPC bar codes with or without Add-ons. NOTE Due to the structure of Add-on codes, selecting the Optional setting makes it impossible to ensure that the scanner will always read the Add-on portion of the label. PSC makes no guarantee, either written or implied, that scanners with optional Add-on decoding enabled will perform with the speed and accuracy required for any given application. Required, the scanner will not recognize or decode any UPC/EAN labels that do not contain an Add-on segment. Disabled, the scanner will not recognize or decode any Add-on segment of UPC/EAN labels. The scanner will read and decode the standard UPC/EAN portion of the label.

TWO DIGIT & FIVE DIGIT ADD-ONS

SET --------------------------------------------------------------- O PTIONAL REQUIRED ------------------------------------------------ DISABLED

END -------------------------------------------------

C128 and Custom Add-Ons A wide array of add-on options are available to streamline your installation to best advantage. Call your salesman or service provider for assistance in customizing your scanner's add-on capabilities to your own unique specifications.

R44-2018

53

SYMBOLOGY SELECTION

UPC/EAN Add-Ons

Page 60

The price/weight check digit selections allow you to specify whether the scanner should calculate an extra check digit based on a four or five-digit price/weight block and compare it with the price/weight check digit contained in the bar code. If the calculated check digit does not match the value of the check digit contained in the bar code, the label will be rejected as invalid. Select domestic four or five digit, European four or five digit, or disable the price/weight check.

SET ----------------------------------------------------- DISABLE P RICE/WEIGHT CHECK PRICE/WEIGHT CHECK DIGIT

SYMBOLOGY SELECTION

Price/Weight Check Digit

ENABLE 4 DIGIT CHECK -----

-------- ENABLE 5 DIGIT CHECK

ENABLE E URO 4 DIGIT CHECK

---- ENABLE EURO 5 DIGIT CHECK

END -------------------------------------------------

54