The text of a manual · part 1 of 10
QuickScan 1000 Programming Guide, pages 1 to 10
Pages 1 to 10 of 97
The original document is the PDF (1.7 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the PSC QS-1000 and Datalogic QS-1000
Page 1
PSC QuIckSCAN UO a)™
HANDHELD LASER SCANNER
PROGRAMMING GUIDE
Page 2
PSC Scanning, Inc. 959 Terry Street Eugene, Oregon 97402-9120 Telephone: (541) 683-5700 Toll Free: (800) 547-2507 Fax: (541) 686-1702 PSC and the PSC logo are registered trademarks of PSC INC. This manual and the procedures described in it are copyrighted, with all rights reserved. Under copyright law, this manual may not be copied in whole or part without prior written consent from PSC Scanning, Inc. The same proprietary and copyright notice must appear on any permitted copies as appears on the original. This exception does not permit copies to be made for others, whether or not sold. Under the law, copying includes translating into another language or format including electronic media. Disclaimer Reasonable measures have been taken to ensure that all information contained in this manual is complete and accurate. However, PSC Scanning, Inc. reserves the right to change any specification at any time without prior notice. IBM® is a registered trademark of International Business Machines Corporation, NCR® is a registered trademark of NCR Corporation, and SNI® is a registered trademark of Siemens Nixdorf Information Systems. Their inclusion in this manual is for the customer's information and convenience only, and constitutes neither an endorsement nor a recommendation for these companies' products or services.
Page 3
Contents Introduction Understanding the Basics .......................................................................... 1 Integrating Peripherals With Host Systems ................................................. 1 Changing Interfaces .................................................................................. 2 Customizing Your Scanner Operation ........................................................ 4 Programming Overview ..................................................................................... 5 What Is Programming Mode? .................................................................... 5 How To Program Using Bar Codes ............................................................ 5 The Programming Session ........................................................................ 6 Scanner Response When In Programming Mode ...................................... 6 If You Make a Mistake... ............................................................................. 7 Return to Factory Settings ......................................................................... 7 Where To Go From Here ........................................................................... 8
Interface Selection IBM IBM 4683/84 • 4693/94 Port 5B Interface Selection ................................... 9 IBM 4683/84 • 4693/94 Port 9A, 9B, 9C, 9E I/F Selection ........................ 10 IBM 4682/92 Port E Interface Selection ................................................... 11 Wand Emulation Wand Emulation Interface Selection ........................................................ 12 RS-232 PSC RS-232 Interface Selection ............................................................. 14 SNI RS-232 Interface Selection .............................................................. 14 RS-232 Communication Parameters ....................................................... 14 Hardware Control ................................................................................... 17 Software Control ..................................................................................... 18 Intercharacter Delay ................................................................................ 20 Keyboard Wedge PC Keyboard Wedge Interface Selection ................................................. 21 Connect to a Laptop/No Keyboard Attached ........................................... 23 Caps Lock ............................................................................................... 24 Country Mode ......................................................................................... 25 Country Mode, continued .................................................................... 26 Intercharacter Delay ................................................................................ 27
R44-2018 i
Page 4
OCIA PSC OCIA Interface Selection ................................................................. 29 NCR OCIA Eight Bit (short format) Interface Selection ............................ 29 NCR OCIA Nine Bit (long format) Interface Selection .............................. 29 SNI OCIA Interface Selection .................................................................. 29 OCIA Options .......................................................................................... 30 Label Transmit Format Configuration Items Prefix & Suffix .......................................................................................... 31 ASCII Character Set ............................................................................... 37
Symbologies Symbology Options Overview .......................................................................... 46 Universal Symbology Selection ................................................................ 47 Symbology Selection ....................................................................................... 48 UPC/EAN Options ........................................................................................... 51 UPC/EAN Expansion ............................................................................... 52 UPC/EAN Add-Ons ................................................................................. 53 C128 and Custom Add-Ons .................................................................... 53 Price/Weight Check Digit ......................................................................... 54 Code 39 Options ............................................................................................. 57 Code 128 Options ........................................................................................... 61 Interleaved 2 of 5 ............................................................................................ 62 Check Digit and Variable Length Label Selections .................................... 63 Standard 2 of 5 ............................................................................................... 66 Check Digit and Variable Length Label Selections .................................... 67 Setting Standard 2 of 5 Fixed and Minimum Label Lengths ..................... 68 Codabar Options ............................................................................................. 71 Codabar Check Digit & Variable Length ................................................... 72 Codabar Start/Stop Character ................................................................ 73 Codabar Fixed Length ............................................................................. 74 MSI/Plessey Options ........................................................................................ 76 MSI/Plessey Check Digit .......................................................................... 76 MSI/Plessey Fixed Length ....................................................................... 77 General Features ............................................................................................ 79 Good Read Beeper Settings .................................................................... 79 Read Verification ...................................................................................... 81 Debug Mode ........................................................................................... 84 Laser Timeout ......................................................................................... 85 Double Read Timeout ............................................................................. 86 ii
QuickScan™ 1000 Programming Guide
Page 5
Appendix A Additional Information Host Programming .......................................................................................... 87 Creating MultiFunction Labels ......................................................................... 87 Need More Information? ................................................................................. 87
Appendix B Sample Bar Codes Sample Bar Codes .......................................................................................... 88
R44-2018 iii
Page 6
NOTES iv
QuickScan™ 1000 Programming Guide
Page 7
This manual contains instructions for changing interfaces and bar codes for customizing the scanner's operation. Since the QuickScan™ 1000 scanner contains software enhancements and characteristics that set it apart from other scanners, it is recommended that this guide be used as the sole source of programming labels and information (except for other QuickScan 1000 product-specific publications). The organization of this manual is intended to support a variety of users while making it quick and easy to find the information you need. Look at the descriptions that follow to find where to go from here.
Understanding the Basics If you do not regularly use bar code labels to configure (program) scanners, it will be very helpful to read the introductory portions of this manual prior to beginning your programming session. In addition to the information that follows, information of specific interest to you is titled:, - - - - - - - - - Integrating Peripherals with Host Systems Changing Interfaces Customizing Your Scanner Operation Programming Overview What is Programming Mode? How to Program Using Bar codes The Programming Session Scanner Response When in Programming Mode If You Make A Mistake Where to Go From Here
Integrating Peripherals With Host Systems It's important to understand that the scanner must contain software and hardware that supports a specific interface in order to use that interface. The following pages describe interface hardware and list software interface groups available on current models. Optimally,you'll want details about how your scanner was configured at the factory before attempting to customize any settings. If you don't have that information, contact your dealer for factory configuration information. After determining the changes and/or additions you desire, locate the programming labels and follow the related instructions in this manual to adjust the scanner. Once you've completed these steps, you can begin scanning. R44-2018
1
GENERAL INFORMATION
Introduction
Page 8
Changing Interfaces To change a scanner's interface… HARDWARE If necessary, replace the scanner's interface cable to match the new host terminal's connection requirements. To disconnect the cable from the scanner, insert a .050” hex driver or bent paper clip into the CABLE RELEASE hole, and press down to unlock the cable connector. Reference Figure 1. NOTE We recommend that you disconnect power before plugging/ unplugging cables to avoid any possibility of equipment damage. Figure 1. Disconnecting the Interface Cable
1.
1
2
SOFTWARE Verify that your scanner supports the desired interface1. The list below indicates interfaces available at the time of this writing. Your scanner comes equipped from the factory with the ability to connect and communicate with at least two major interface types, for example, Keyboard Wedge/RS-232 and Keyboard Wedge/Wand Emulation are two common pairings. Contact your nearest PSC service depot if you don't know your scanner's interface group, or need to have the scanner altered to change to another I/F group. Contact your dealer if your desired interface is not listed. Interface group definitions are subject to change without notice.
QuickScan™ 1000 Programming Guide
Page 9
GENERAL INFORMATION
RS-232 • PSC RS-232 • SNI RS-232 IBM • IBM 4683/84, 4693/94 Port 5B • 4682/92 Port E • IBM 4683/84, 4693/94 Port 9A, 9B, 9C, 9E Wand Emulation KeyboardWedge • I/F Type A, PC/XT w/foreign keyboard • I/F Type B, AT, PS/2 25-286, 30-286, 50, 50Z, 60, 70, 80, 90 & 95 w/ foreign keyboard • I/F Type C, PS/2 25 and 30 w/foreign keyboard • I/F Type D, PC/XT w/US keyboard • I/F Type E, AT, PS/2 25-286, 30-286, 50, 50Z, 60, 70, 80, 90 & 95 w/ US keyboard • I/F Type F, PS/2 25 and 30 w/US keyboard • I/F Type G, IBM 3xxx w/122 keyboard • I/F Type H, IBM 3xxx w/102 keyboard • I/F Type I, PS/55 5530T w/104 keyboard • I/F Type J NEC 9801 keyboard OCIA • PSC OCIA • NCR 8 bit OCIA • NCR 9 bit OCIA • SNI OCIA 2.
Turn to the appropriate page in this manual and enable the desired interface or interface sub-type by scanning its programming bar code. These interface/interface sub-type selection bar codes are located at the beginning of each of these sections of the manual: IBM, Wand Emulation, RS-232, Keyboard Wedge, and OCIA. This will enable the software for the new interface and disable the 'old' interface software. Once enabled, the new interface becomes the default interface that is active whenever power is applied to the scanner.
3.
Scan a bar code to verify that the scanner communicates correctly with the host system. Some sample bar codes are provided on the last pages of this manual. If any changes to the scanner's factory settings are needed, use the instructions titled, Customizing Your Scanner Operation.
R44-2018
3
Page 10
Customizing Your Scanner Operation When enabling a new interface, it may be necessary to modify the original factory settings to match your specific host system's communication and symbology requirements. Check with your system administrator to identify your host system's specific interface requirements to ensure that they match the new interface you've selected. Also, the scanner's operational features, such as speaker volume, can be customized to match your unique requirements. 1.
Use the labels in this manual to modify the standard configuration to matchyourspecificinterfacerequirementsoruserpreference. NOTE Ensure that your planned modifications are compatible with the current interface. For example, baud rate selections are only valid in the RS-232 interface. The scanner will sound an error tone (six rapid beeps) when scanning programming labels for features invalid to the current interface.
2.
Enable any additional symbologies as required and exit Programming Mode.
3.
Scan a regular bar code label and verify that the scanner and host communicate correctly.
4.
You have completed the factory settings change procedure.
If you experience difficulties, have questions or require additional information, contact your local distributor using the listings located on the back cover of this guide.
4
QuickScan™ 1000 Programming Guide